Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 54,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670842_1Bid Award Id
ViewTender No
8796/VAL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
0.6
-
-
... More
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in stand posts, pedestal to poles, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed including demolition of existing PCC all as directed.
1
-
-
... More
M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed.
Note: Reinforcement shall be measured and paid for separately.
3
-
-
... More
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
120
-
-
... More
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
50
-
-
... More
M&L in repair for street light bracket made from MS tubing in required size & shape at site, cut to length, bend to shape required and suitable for existing street light pole and fixing the bracket to pole with MS flat and nuts and bolts and finally painting the exposed steel surface with two coats of first quality synthetic enamel paint of approved tint over a coat of zinc chromate primer complete all as directed. Notes :- (i) Size, section and shape of MS pipe shall be as directed. (ii) Quoted rate shall deemed to be inclusive of painting. Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.
30
-
-
... More
S&F in repair LED driver of 72 W LED Street light/ flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JQMSRT01S072/ Havells / existing make as approved by GE.
8
-
-
... More
S&F in repair LED driver of 90 W LED Street light/ flood light fitting. Make: Osram/ Wipro LG56-036-002-1540/ Bajaj/ Jaquar ZDR-WHT-JQMSRT01S090/ Havells / existing make as approved by GE.
10
-
-
... More
S&F in repair LED driver of 120 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JBIFLDSLM120/ Havells / existing make as approved by GE.
2
-
-
... More
S&F in repair LED driver of 150 W LED flood light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar ZDR-WHT-JBIFLDSLM150/ Havells/ existing make as approved by GE.
2
-
-
... More
S&F in repair LED driver of 8/9/10 W LED Bollard light fitting. Make: Osram/ Wipro/ Bajaj/ Jaquar/ Havells/ existing make as approved by GE.
25
-
-
... More
S&F in repairs 3 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable (ISI marked) 1100 Volts grade drawn through existing conduit pipe from junction box to fitting complete all as directed.
160
-
-
... More
S&F in repairs Junction box made from SMC/FRP sheet readymade of size 300x200x100 mm having 100 A capacity including RYB and neutral with aluminium busbar, with & including MCB SP 6 Amp 10 kA 'C' Curve 240 V (01 No.) fixed to pole/wall with MS clamp made out of MS flat iron 25x5 mm with suitable nut, bolts, etc and necessary painting to MS clamp with two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified & as directed.
12
-
-
... More
S&F in repairs MCB TPN 32 Amp, 415 V, 50 Hz, AC supply, 10 kA 'C' Curve with proper size lugs complete all as directed. Make: Legrand Cat No. 4086 80 or equivalent in makes mentioned in Appendix 'B' here-in-after.
2
-
-
... More
S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply, 10 kA 'C' Curve with proper size lugs complete all as directed. Make: Legrand Cat No. 4086 83 or equivalent in makes mentioned in Appendix 'B' here-in-after.
8
-
-
... More
S&F in repairs MCB SP 6 Amp, 50 Hz, AC supply, 10 kA 'C' Curve with proper size lugs complete all as directed.
Make: Legrand Cat No. 4085 87 or equivalent in makes mentioned in Appendix 'B' here-in-after.
10
-
-
... More
Taking down existing post top lantern of any description and S&F new 45W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj 'BGCTN 45W LED WW' or equivalent in makes mentioned in Appendix 'B' here-in-after.
22
-
-
... More
Taking down existing post top lantern of any description and S&F new 25W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj 'BGCTN 25W LED WW' or equivalent in makes mentioned in Appendix 'B' here-in-after.
6
-
-
... More
Taking down existing post top lantern of any description and S&F new warm white 45W decorative LED outdoor Post Top heritage lighting fixture, powder coated pressure die cast aluminium housing and IP 65 protection, the fitting shall have LED with lens and PCB, glare free indirect light fitting, CCT 4000K, and fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as directed.
Make : Bajaj Cat No. BRIL 45W LED NW, Model No. ‘TENCO’, Crompton Cat No. LPTOI-45-CDL, Model No. ‘FERN’ or equivalent in makes mentioned in Appendix 'B' here-in-after.
5
-
-
... More
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed.
28
-
-
... More
Taking down existing flood light fitting of any description and S&F new 50 W LED flood light fitting, IP-65 rated with high pressure die cast aluminium housing, powder coated, CCT 5700K, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system and testing on completion complete all as directed.
Make : Bajaj 'BJFL 50W LED' or equivalent in makes mentioned in Appendix 'B' here-in-after.
4
-
-
... More
Taking down existing flood light fitting of any description and S&F new 150 W LED flood light fitting, IP-66 rated with high pressure die cast aluminium housing, lens and toughened glass cover, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, CCT 5700K, with & including external Surge Protection Device (SPD) 10 kV, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system and testing on completion complete all as directed.
5
-
-
... More
Taking down existing flood light fitting of any description and S&F new 200 W LED flood light fitting, IP-66 rated with high pressure die cast aluminium housing, lens and toughened glass cover, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, CCT 5700K, with & including external Surge Protection Device (SPD) 10 kV, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system and testing on completion complete all as directed.
4
-
-
... More
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5500K, powder coated pressure die spun aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED, Beam Angle (Throw & Spread) - 52"x24" and metal clad PCB, the minimum lumen output of the system should be greater than 9000 lumens with minimum lumens per watt 115±10% asymmetric fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed. Make: Bajaj Cat No. BCG BOR 90W LED CL TM CR or equivalent in makes mentioned in Appendix 'B' here-in-after.
6
-
-
... More
Taking down existing bollard light fitting and S&F new 9/10 W LED Bollard light fitting IP-54 rated with inbuilt LED, made in die cast aluminium housing Frosted polycarbonate diffuser, CCT 3000K complete with all standard accessories fixed as per manufacturer's instructions and making necessary electrical connections including testing on completion complete all as directed. Make: Bajaj Cat No. BGBOM 1000 9W LED WH / Jaquar Cat No. LBLDCON010XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
30
-
-
... More
Taking down existing Gate/ Post top light fitting and S&F 28W new LED Gate/Post Top lighting fixture, IP-65 protection, outdoor type, decorative, energy saving, environmental friendly, long life aesthetically designed with Die cast aluminium housing, Heat resistant toughened bell shaped acrylic diffuser, MS housing with PU paint, Top canopy made of spun aluminium, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, complete all as directed. Make : Jaquar Model 'Avior' Cat No. LGTP04X028XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
20
-
-
... More
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed over & including mounting bracket made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed.
13
-
-
... More
Taking down existing light fitting of any type & fixed in any position and S&F new 2 x 6 Watt LED wall mounted UP and DOWN clear/ warm white decorative LED light fixture with die cast aluminium housing transparent tempered glass diffuser, minimum IP 54 protection, minimum CCT 2700K, fixed in any position on wall with Screw/ nut bolt properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed.
Make : Wipro Cat No. GARNET DW31227, Jaquar Cat No. LWWL02R206XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
8
-
-
... More
Taking down existing light fitting of any type & fixed in any position and S&F new 9/12 Watt LED surface mounted UP SPIKE/ BUSH light fixture, with die cast aluminium housing transparent tempered glass diffuser, minimum IP 65 protection, minimum CCT 3000K, fixed in any position over surface by spikes properly as per site requirement with all accessories and making necessary electrical connections and testing on completion complete all as directed.
Make: Bajaj Cat No. BGSBL 9W LED WW or Jaquar Cat No. LSPK05R112XW or equivalent in makes mentioned in Appendix 'B' here-in-after.
10
-
-
... More
S&F in repairs Aviation obstruction Red LED light 8.5 watt, 230 volts, IP 65, 50 Hz, fixing on top of the OHT/ Watch tower of height upto 25 mtr including necessary electrical connection and foundation complete all as specified & as directed.
Note : Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of aviation light on top of OHT/ Watch tower and quoted rate shall deemed to be included of this aspect.
3
-
-
... More
S&F in repair High Pressure Sodium Vapour (HPSV) Lamp of 1000 Watt, 240 Volt, 50 Hz fixed in light fitting on top of Watch tower i.e. height of 15 mtr with all necessary electrical connection complete all as specified and as directed. Note : Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of HPSV lamp on top of Watch tower and quoted rate shall deemed to be included of this aspect.
1
-
-
... More
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 3 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 16 mm dia, pitch circle dia 200 mm, bolt length 450 mm, projected bolt length 80 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 A, 240 V, 10 kA, 'C' Curve (1 No.), Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-3030 or equivalent in makes mentioned in Appendix 'B' here-in-after.
Note: Earth work and PCC foundation shall be measured & paid for separately.
15
-
-
... More
S&F in repair Power Contactor, 3 Pole, AC1 rating - 45 Amp, including necessary connections for incoming and outgoing complete all as specified & as directed. Make : L&T Type ML3 Cat No. SS90721 or equivalent in makes mentioned in Appendix 'B' here-in-after.
2
-
-
... More
S&F in repairs Astro digital time switch, 1 Out put 16 A, 1 channel mounting in existing panel, suitable for switching ON/OFF light and other electric devices according to the rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/or fixed preset times and also suitable for daily astronomical calculation of the sunrise/sunset time based on the entered location or location coordinate complete all as directed. Make: Legrand Cat No. 4126 54 or equivalent in makes mentioned in Appendix 'B' here-in-after.
2
-
-
... More
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.
Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
120
-
-
... More
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed.
Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.
250
-
-
... More
Supply and laying/fixing 25 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
210
-
-
... More
Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
90
-
-
... More
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed.
Note :- Excavation & earthwork shall be measured & paid for separately.
12
-
-
... More
M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 120cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed.
12
-
-
... More
Disconnecting, dismantling & taking down old unserviceable Panel Box of any size & capacity including all fixtures/accessories and Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new outdoor type LT Timer Switch Panel Box cubical type of suitable size (minimum depth 500mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 3.15 mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet, with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-55 with coloured insulation sleeve, rubber gasket, insulators, outdoor type, totally enclosed, weather, dust and vermin proof as per IS, Front & Rear opening with double door shutters having suitable aldrop bolt locking arrangement, with insulators, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground level and 30cm below ground level, comprising & including the following accessories complete all as specified and as directed :- (a) MCB TPN 63 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 01 No. as incoming. (b) MCB TPN 32 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 02 Nos. as outgoing. description of item contd....
4
-
-
... More
Description of serial item No. 44 contd…
(c) Astro digital time switch, 1 output, 16 A - 250 VA, 50/60 Hz, Astronomical function, 56 Programmes, 1 Channel, 2 Module - 01 No. Make: Legrand Cat Part No. 4126 54 or equivalent in makes mentioned in Appendix 'B' here-in-after.
(d) Contactor CTX3 TP, 65A, 230V - Integrated auxiliary Contacts 2NO+2NC, screw terminals - 01 No. Make: Legrand Cat Part No.4161 66 or equivalent in makes mentioned in Appendix 'B' here-in-after.
(e) Selector Switch for Manual/ Auto Mode - 01 No.
(f) Indicator Set RYB, “LED” type (set of three) -01 Set
(g) Bus bar minimum 200 Amp aluminium with R/Y/B coloured for three Phases and 100 Amp for Neutral Black colour insulation sleeves - 01 Set
Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in ground minimum 30cm in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.
-
-
-
... More
Taking down old existing aluminium strip & GI strip of any size including testing points, porcelain insulators, PCC blocks, etc complete all as specified and as directed.
180
-
-
... More
M&L for aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified & as directed.
150
-
-
... More
M&L for galvanised iron strip 32 x 6mm buried in ground / fixed on wall complete all as specified and as directed.
30
-
-
... More
S&F porcelain insulator of overall minimum size 72mm x 32mm x 34mm (single pole bus bar support insulator) suitable for fixing aluminium/GI strip roof/down conductors, fixed in PCC blocks/walls/pole/pipe with two Nos hexagonal head GI screws 40mm long, one No. hexagonal head GI bolt 30mm long & 5-6mm dia with one No. square shaped GI washer of size 25x25mm & 0.6-0.8mm thickness & one No. GI nut for fixing/running the roof/down conductors, conforming to the sample kept in GE’s office, complete all as specified & as directed.
Note : Cost of screws, bolt, washer & nut is included in quoted rates.
150
-
-
... More
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screws, enclosed in suitable PVC box, complete all as specified & as directed.
8
-
-
... More
M&L for Air termination, single pointed aluminium rod 12mm dia and 300mm long fix to aluminium strip, nut, bolts and washers including taking down existing air termination complete all as specified & as directed.
20
-
-
... More
M&L for precast PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate as in bed blocks, anchorage blocks, foundation blocks, kneelers, apex stones, bed plates, cover slabs, mangers, shelves and similar articles with plain faces including placing in position over roof etc and set in CM (1:4) complete all as specified & as directed.
0.4
-
-
... More
M&L for Galvanized iron tubing, 32mm bore, light grade, ISI marked, with & including all fittings and fixed to walls / ceilings or laid in floors complete all as specified & as directed.
9
-
-
... More
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed including dismantling & taking out old existing unserviceable earthing.
Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
8
-
-
... More
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
2
-
-