Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date2 Sep 2024
Closing Date7 Oct 2024
Tender Amount₹ 2,51,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material & Labour for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors.

50

-

-

... More
Material & Labour for joint free coloured (of any shade) vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, double charged, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15mm thick for laying floor fiishes with CM 1:4 complete.

930

-

-

... More
Material & Labour for joint free coloured (of any shade) vitrified ceramic tiles 10 mm thick (square/ rectangular) polished, double charged, area of each tile not exceeding 0.36 sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick rendering for backing coat on vertical surface of wall or concrete surfaces in CM 1:3 to receive wall tiles.

93

-

-

... More
Material & Labour for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) in floors etc. area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM 1:4.

429

-

-

... More
Material & Labour for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) area of each tile exc. 0.11 sqm but n. exc. 0.18 sqm, on vertical surfaces such as skirtings, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10 mm thick rendering in CM 1:3 on stone masonry surfaces/brick work or concrete surfaces.

42.9

-

-

... More
Material & Labour for non skid ceramic tiles, coloured, 7 to 8 mm thick (square/rectangular) in floors etc. area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layer in CM 1:4 (Tile pattern and decoration shall be as directed by Engineer-in-charge).

60

-

-

... More
Material & Labour for glazed ceramic tiles, coloured, 450x300x7mm thick on vertical surfaces such as skirting, dados and risers to steps etc, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering in CM 1:3 on stone masonry surface/brick work or concrete surface. (Tile pattern and decoration shall be as directed by Engineer in-Charge.)

605

-

-

... More
Material & Labour Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) 10mm thick backing/Screed including pointing in white cement (1:2) using marble dust with admixture of pigment to match complete all as specified and directed.

194

-

-

... More
Rounding to edges of stone slabs such as steps cooking platefrom and other similar situations complete all as specified

317

-

-

... More
Material & Labour for machine cut kota stone slab 20-25 mm thick in flooring over and including 15 mm thick cement screed bed or bedding layer in CM 1:4 mixed with high performance adhesive as per manufacturers instructions, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Note:- High performance adhesive shall be measured and paid for separetely as "Supply only".

122

-

-

... More
Material & Labour for kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick rendering in CM 1:3 on stone masonry surfaces/brick work or concrete surfaces mixed with high performance adhesive as per manufacturers instructions and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete. Note:- High performance adhesive shall be measured and paid for separetely as "Supply only".

37

-

-

... More
Demolition of cement concrete (reinforced) (reinforcement cut as required to facilitate demolition) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and removing from site all as specified and directed.

1.5

-

-

... More
Provsion and application of approved epoxy based bond coat on concrete surfaces or sound bonding of cold and new concrete surfaces according to instructions of engineer in charge Make Fosroc/ pidilite or equivalent

15

-

-

... More
Material & Labour for super fluid micro concrete-roffe crete repairs (or equivalent as specified in the list of brand names) in beam bottoms, columns, slabs etc. including mixing with 5 mm to 10 mm size aggregates, consolidating, curing etc. complete as per manufacturer's specifications and consultants instructions. Note:- This item shall be measured and paid for on the actual consumption of micro concrete.

200

-

-

... More
Making of profile of structral memebers with polymer modified mortar in damaged areas 1:3 ( Cement:sand) mortar with 5 -10percentage addition of latex polymer,w/c ratio of 0.35 in 20 mm thk layers / including leveling etc complete . Make Fosroc/ Pidilite or equivalent

15

-

-

... More
Material & Labour for cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in floors any thickness in platform for PVC tank and similar work etc as directed.

1.3

-

-

... More
Taking down cement plaster, any description on brick, concrete or stone walls or ceiling including racking out joints, hacking for key, scrubbing down with water etc and removal of rubbish off all as specified and directed.

6460

-

-

... More
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.

12

-

-

... More
Material & Labour for brick work with sub class 'B’ bricks using old size bricks, straight or curved on plan exc. 6 m mean radius, built in CM 1:6.

15

-

-

... More
Material & Labour for brick work with sub class 'B’ bricks, old size bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.

21

-

-

... More
Material & Labour for rendering 10 mm thick in CM 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement.

3306

-

-

... More
Material & Labour for rendering 5 mm thick in CM 1:4 mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement, over and including 10 mm thick rendering in CM 1:6 on brick work or concrete surfaces. Note:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”

1794

-

-

... More
Material & Labour for rendering 10 mm thick in CM 1:4 on concrete surfaces in ceiling (facia/ceiling/edging of chajjas and roof projection) including finishing even and smooth without using extra cement.

1360

-

-

... More
Material & Labour for preparation of new plastered or unplastered surfaces of walls and applying two coats of distemper oil emulsion, white or tinted, over and including a coat of 01 to 02 mm thick Birla/JK wall care putty over a coat of primer all as directed.

3306

-

-

... More
Material & Labour for complete removal of existing treatment from walls and applying two coats of distemper oil emulsion, white or tinted, over and including of 01 to 02 mm thick Birla/JK wall care putty over a coat of primer all as directed.

726

-

-

... More
Material & Labour for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash.

1360

-

-

... More
Material & Labour for complete removal of existing treatment on old plastered or unplastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.

720

-

-

... More
Material & Labour for applying Two coats of damp proof waterproofing coating @ 2.7–3.2 m2/L/coat over new plastered surface of exterior wall complete all as per manufacturer instuctions. (Make: Nerolac, Berger or equivalent) (Note: Damp proof coat applied to wall surface before exterior emulsion paint)

1794

-

-

... More
Material & Labour for preparation of newly plastered surfaces of walls/ceilings of roof projection and chajjas etc. and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old/new surfaces.

1794

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC block/brick work etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.

30

-

-

... More
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm but not exceeding 4 sqm each and removing from site. Note - Quoted rate shall be deemed to be include for cutting holes/demolition of PCC block/brick work etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.

102

-

-

... More
Supply & Fixing 35 mm thick flush shutters, solid core construction, with block board core, both faces covered with decorative prelaminated work with 6 mm thick teak wood edging all round.

24

-

-

... More
Supply & Fixing aluminium powder coated of any colour (minimum thickness of powder coating 50 micron) frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified

579

-

-

... More
Supply & Fixing of Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.

940

-

-

... More
Supply & Fixing sheet glass 4 mm thick, ordinary quality and glazing with neoprene beading in square exc 0.5 sqm in each pane.

53

-

-

... More
Supply & Fixing sheet glass 4 mm thick, figured glass, pin headed type and glazing with neoprene beading in square n. exc. 0.5 sqm in each pane.

10

-

-

... More
Supply & Fixing stainless steel wire cloth, 0.36 nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or wooden beads supplied with shutters.

27

-

-

... More
Supply & Fixing mild steel of grade Fe-290 (Grade E-165) in bands, straps, supports or stays for rain water, ventilating pipes including bolts, if required, clamps, hold fasts and similar small articles.

45

-

-

... More
Material & Labour for PCC 1:3:6 type C-0 using 12.5 mm graded stone aggregate in cills, steps, bands, copings, bed plates, blocks for inserting hold fasts, filling back of chowkats etc. and the like including weathering, slightly rounded or chamfered angles and throating as directed.

1.5

-

-

... More
Material & Labour for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/Angle iron frame/PVC door frame with screw complete all as specified and directed.

33

-

-

... More
Material & Labour for 75mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame/Angle iron frame/PVC door frame with screw complete all as specified and directed.

30

-

-

... More
Supply & Fixing 200 mm long aluminium, anodized, barrel tower bolts of extruded section and fixed.

41

-

-

... More
Supply & Fixing 150 mm size extruded aluminium alloy handles, fabricated type, anodized.

42

-

-

... More
Supply & Fixing hasp and staple of size 75 mm, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws.

10

-

-

... More
Supply & Fixing 150 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.

10

-

-

... More
Supply & Fixing 250 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.

11

-

-

... More
Supply & Fixing Factory made single extruded WPC (Wood polymer composite) solid door Frame/Chowkhat comprising of 62mmx32mm size applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 KG/Cum and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/SS dash fasteners of required dia and length all as specified and directed.

51

-

-

... More
Supply & Fixing factory made 28-30mm thick single extruded WPC (Wood polymer composite) solid panel flush door shutter of required size modulus of elasticity 850 N/mm^2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screws complete all as specified and directed.

19

-

-

... More
Supply & Fixing in repair 18mm thick HDHMR BOARD exterior grade including any coloured prelaminated sheet of required thickness over HDHMR board, anti fungal, moisture resistance, anti borer as per IS 14587 for frame and shutter for kitchen cabinets/cupboards etc all as per specified and directed by Engr-in-charge. Note: sample as approved by GE. Make: Action Tessa/Greenply/Century.

116

-

-

... More
Supply & Fixing in repair 18mm thick HDHMR BOARD exterior grade including white coloured prelaminated sheet of required thickness over HDHMR board, anti fungal, moisture resistance, anti borer as per IS 14587 for frame and shutter for kitchen cabinets/cupboards etc all as per specified and directed by Engr-in-charge. Note: sample as approved by GE. Make: Action Tessa/Greenply/Century.

13

-

-

... More
Supply & Fixing 100 mm Pull door handles, chrome finish, Stainless steel of SS 304 grade all as per specified and directed by Engr-in-charge. Note: sample as approved by EIC/GE.

54

-

-

... More
Supply & Fixing magnet door stopper of rectangular size for PVC cabinets including all fittings fixed complete all as specified and directed.

54

-

-

... More
Supply & Fixing in repairs 22 to 25 mm dia stainless steel curtain rod, fancy type/decorative type, fixed to walls complete all as directed.

225

-

-

... More
Supply & Fixing in repairs, stainless steel decorative finials (round type with mirror optic finish trade/standard pattern suitable for 22 to 25 mm dia decorative/fancy type curtain rods.

150

-

-

... More
Supply & Fixing in repairs brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges.

5

-

-

... More
Supply & Fixing in repairs, Cat. No. F5015131CH Towel Rack With Hook 24" 600mm Long with Lower Hangers, Stainless Steel complete all as specified and directed. (Make: Cera or equivalent)

5

-

-

... More
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete.

5.2

-

-

... More
Supply & Fixing rolled mild steel of grade Fe-290 (Grade E-165) in rolled section as in frames for doors/windows, framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.

1600

-

-

... More
Supply & Fixing mild steel of grade Fe-290 (Grade E-165) in framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders; ramed balusters; walk ways; railings; framework of water tanks and similar works.

1064

-

-

... More
Supply & Fixing for preparation of new or previously untreated steel surfaces of any description, over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer.

158

-

-

... More
Supply & Fixing for preparation of old painted wooden surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint.

10

-

-

... More
Taking up or down steel tubing 15 mm bore and connections including cleaning for refixing or removing from site.

100

-

-

... More
Supply & Fixing 20 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed

100

-

-

... More
Taking up or down steel tubing 20 mm bore and connections including cleaning for refixing or removing from site.

84

-

-

... More
Supply and laying 20 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.

84

-

-

... More
Taking up or down steel tubing 25 mm bore and connections including cleaning for refixing or removing from site.

72

-

-

... More
Supply and laying 25 mm bore tubes, galvanized steel, medium grade, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.

60

-

-

... More
Supply & Fixing 32 mm outer dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and directed

12

-

-

... More
Dismantling of cast iron or reinforced concrete drain pipes of 100 mm internal dia, jointed in cement mortar and taking out of trenches, if required.

99

-

-

... More
Dismantling of cast iron or reinforced concrete drain pipes of 75 mm internal dia, jointed in cement mortar and taking out of trenches, if required.

84

-

-

... More
Supply & Fixing 110 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints fixed to walls.

84

-

-

... More
Supply & Fixing 110 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints, laid in trenches or in floors.

15

-

-

... More
Supply & Fixing in repairs 110 mm bore UPVC (SWR) bend, suitable for type ‘B’ pipes, any radius.

24

-

-

... More
Supply & Fixing in repairs 110 mm bore UPVC (SWR) bend, suitable for type ‘B’ pipes, any radius with oval access door.

8

-

-

... More
Supply & Fixing 75 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints fixed to walls.

74

-

-

... More
Supply & Fixing 75 mm bore UPVC (SWR) pipes type ‘B’, single socketed, in any length, with rubber ring joints, laid in trenches or in floors.

10

-

-

... More
Supply & Fixing in repairs 75 mm bore UPVC (SWR) bend, suitable for type ‘B’ pipes, any radius.

24

-

-

... More
Supply & Fixing in repairs 75 mm bore UPVC (SWR) bend, suitable for type ‘B’ pipes, any radius with oval access door.

8

-

-

... More
Supply & Fixing in repairs for PVC (SWR) floor trap, suitable for type ‘B’ pipes, 75 mm dia of outlet, plain with grating including jointing with solvent cement.

15

-

-

... More
Supply & Fixing in repairs 110 mm bore UPVC (SWR) branch piece, suitable for type ‘B’ pipes, single (single Y) equal or unequal with oval access door.

5

-

-

... More
Supply & Fixing in repairs 75 mm bore UPVC (SWR) branch piece, suitable for type ‘B’ pipes, single (single Y) equal or unequal with oval access door.

5

-

-

... More
Supply & Fixing stack clamps, for 110 mm bore pipe, out of 50x5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof.

42

-

-

... More
Supply & Fixing stack clamps, for 75 mm bore pipe, out of 50x5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof.

35

-

-

... More
Supply & Fixing in repairs 110 mm bore UPVC (SWR) vent cowl, suitable for type ‘B’ pipes.

8

-

-

... More
Supply & Fixing in repairs 75 mm bore UPVC (SWR) vent cowl, suitable for type ‘B’ pipes.

8

-

-

... More
Supply & Fixing in repairs 15 mm bore bib taps (long body), cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule as per Cat part No. CON-107KN of Make-Jaquar or techno commercially equivalent of any make specified.

12

-

-

... More
Supply & Fixing 15 mm bore bib taps (long body), cast copper alloy, fancy type, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule as per Cat part No. CON-107KN of Make-Jaquar or techno commercially equivalent of any make specified.

8

-

-

... More
Supply & Fixing in repairs, two way angle valve fancy type chromium plated 15mm bore cast copper alloy with capstan heads, screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.

10

-

-

... More
Supply & Fixing in repairs 15 mm bore stop valve/angle valve, cast copper alloy, fancy type, chromium plated, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or for unions.

30

-

-

... More
Supply & Fixing in repairs 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.

12

-

-

... More
Supply & Fixing 25 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe.

2

-

-

... More
Dismantling water tanks of any description, exc. 250 & n. exc. 500 litres capacity and removing from site.

2

-

-

... More
Dismantling water tanks of any description, exc. 500 & n. exc. 1000 litres capacity and removing from site.

4

-

-

... More
Supply & Fixing 1000 litres capacity rotational moulded polyethylene water storage tanks triple layer (cylindrical vertical with closed top), hoisted and fixed in position including 25mm dia tank Nipple/Adaptor complete all as specified in SSR Part-I.

6

-

-

... More
Supply & Fixing 25 mm bore ball brass valves, high pressure, with polythene float and fly- nut complete, screwed for iron pipe or brass ferrule and fixed.

6

-

-

... More
Supply & Fixing in soap dish/shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) complete all as specified and as directed.

12

-

-

... More
Supply & Fixing 32mm dia Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm - 260gms / 40mm-270 gms) complete all as specified and as directed.

10

-

-

... More
Supply & Fixing in repairs Vitreous china premium/ 1st quality wash down water closet wall hung EWC white/ ivory/off white (closed pattern incl all necessary accessories like rag bolts/ gel gasket etc. (excluding flushing cistern & flush pipe) of size 655 x 350 x 735 mm (Cat. No. S1031101) including plastic water closet seat, (Cat. No. B1520102) soft close seat cover, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging devicecomplete in all respect all as specified. (Make: Cera or equivalent)

6

-

-

... More
Supply & Fixing in repairs for PVC low level flushing Cistern white with Twin flush fittings Cat. No. S1062128 10 ltrs capacity with all internal accessories & fixed to wall & making good to wall surfaces including taking down existing flushing cistern complete. Make: Cera & equivalent.

6

-

-

... More
Supply & Fixing in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolt) including PVC valveless, syphonic action type, flushing cistern, low level, 10 litres capacity, white, with inlet, ball valve, float and handle including brackets and PVC flushing pipe, 32 mm dia complete all as specified.

4

-

-

... More
Supply only PVC flushing cistren low level, 10 ltr capacity with syphonic action type ball valve. Incl iall fittings complete Note :- Fixing of Flushing cistern included with fixing of WC as above.

4

-

-

... More
Supply & Fixing 110 mm bore UPVC (SWR) WC connector with lip ring.

10

-

-

... More
Supply & Fixing 110 mm bore UPVC (SWR) WC connector bent type.

10

-

-

... More
Supply & Fixing in repairs 110 mm bore UPVC (SWR) junction, suitable for type ‘B’ pipes, single (single T) equal or unequal.

5

-

-

... More
Supply & Fixing 110 mm bore UPVC (SWR) junction, suitable for type ‘B’ pipes, single (single T) equal or unequal.

2

-

-

... More
Supply & Fixing in repairs 75 mm bore UPVC (SWR) junction, suitable for type ‘B’ pipes, single (single T) equal or unequal.

4

-

-

... More
Supply & Fixing in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.

10

-

-

... More
Supply & Fixing in repairs vitreous china wash basin, white/ivory, oval type, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length complete all as specified.

10

-

-

... More
Supply & Fixing vitreous china wash basin, white/ivory, oval type, size 550x400mm including brackets, cutting for and pinning in ends of brackets or erecting stand, brass chromium plated perforated waste coupling/fittings 32 mm dia with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed and PVC waste pipe of 32 mm bore and of suitable length complete all as specified.

2

-

-

... More
S&F in repair 15 mm bore Pillar taps, cast copper alloy, with capston heads, chromium plated fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.

10

-

-

... More
Supply & Fixing15 mm bore Pillar taps, cast copper alloy, with capston heads, chromium plated fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts screwed for iron pipe and fixed complete all as specified and directed.

2

-

-

... More
Supply & Fixing 15mm dia chromium plated, fancy type, sink cock with swivel neck.

3

-

-

... More
Supply & Fixing PVC connection 15 mm size with PTMT nuts of length 450 mm.

30

-

-

... More
Supply & Fixing in repairs, 5.5 mm thick, 600 X 450mm bevelled edge mirror of selected quality glass, mounted on PVC frame and fixed to wooden plugs with CP brass screws and cup washers.

10

-

-

... More
Supply & Fixing in repairs 450 x 350 mm cabinet mirror of selected quality 5 mm thick glass with PVC storage cabinet fixed with chromium plated brass screws and cup washers to wall.

6

-

-

... More
Supply & Fixing in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever bracket, necessary chromium plated watse coupling, waste pipe and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified.

3

-

-

... More
Supply & Fixing stainless steel plate rack, 0.50 mm thick of standard pattern, of size 36"x30"x10" suitable for stacking 15 to 18 plates with hooks/fittings complete all as specified and directed.

3

-

-

... More
Material & Labour for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection,chajja,fins,facia, roof bands etc and making good with RCC (1:1½:3) type A0 (nominal mix) (using 12.5 mm graded stone aggregate) in RCC roof projection,chajja, fins,facia, roof bands etc and finished surface even and smooth without using extra cement including necessary form work and welding/binding of reinforcement (including 0.9mm dia expanded metal wire mesh, for wrapping RCC members wherever required) if required complete as directed by the Engr-in-Charge. (Reiforcement will be measured and paid saperately under respective item)

2.5

-

-

... More
Material & Labour for precast reinforced cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, shelves and similar articles with plain faces, set in CM 1:4, including necessary form work moulds etc all as specified. (Reinforcement shall be measured and paid for separately).

2.16

-

-

... More
Material & Labour for RCC 1:2:4 type B-1 (Nominal mix) using 20 mm graded stone aggregate in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like and chajjah including necessary form work all as directed

0.5

-

-

... More
Material & Labour for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.

650

-

-

... More
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for (roof padding/roof kerb/sunken floor etc.) including tarfelt, plaster etc. and removing from site all as specified and directed.

47

-

-

... More
Material & Labour for cement concrete 1:2:4 type B-0 mix (12.5 mm graded stone aggregate) in padding over roof of any thickness.

35.5

-

-

... More
Material & Labour for brushing neat cement slurry with 3.00 kg of cement per sqm.

710

-

-

... More
Material & Labour for 15 mm thick rendering in CM 1:3 over concrete surfaces (Roof) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement complete all as specified. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.

710

-

-

... More
Material & Labour for water Proofing treatment to roof slabs by applying one coat of bituminious/polymerized primer confirming to IS-3384 @ 0.40 Ltrs/Sqm, 3 mm thick APP modified polymeric membrane of weight of 3 kg/sqm with non-woven polyester reinforcement shall be laid over a coat of bitumen S-35 grade (30/40) applied @1.20Kg /Sqm (minimum) with minimum 75 mm side overlaps and minimum 100 mm end overlaps, joints & overlaps shall be sealed and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete all as specified and directed by Engr-In-Charge (Note: the primer and the membrane to be used shall be of the same manufacturer and to be applied by authorized applicator of OEM).

746

-

-

... More
Material & Labour for Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 10 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and as directed.

746

-

-

... More
Supply only liquid water proofing compound.

52

-

-

... More
Material & Labour for 15 mm thick rendering on floor and vertical side of sunken floor of stone masonry surfaces/brick work/concrete surfaces in CM (1:3) mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement and finished even and smooth without using extra cement complete all as specified and directed. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.

3.24

-

-

... More
Material & Labour for applying roof/sunken treatment on sunken floor with APP modified membrane (minium 3mm thick) weight not less than 3 kg/sqm and reinforced with non-woven polyester reinforcement/mat (centre core) with thermal insulation with polythene finish on upper side of membrane, laid by torch application method with overlaps 150 mm on length side and 100mm on the width side as per manufacturer's instructions over and including a coat of approved cold applied bituminous oil based primer (IS-3384) @ 250 gm/sqm complete all as specified and as directed by Engineer-in-Charge.

3.24

-

-

... More
Material & Labour for cement concrete (1:5:10) type E-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed.

0.5

-

-

... More
Material & Labour for 25 mm thick PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate in sub floors mixed with liquid water proofing compound @ 0.200 litre per bag of 50 kg of cement. NOTE:- Liquid water proofing compound shall be measured and paid for separately as “Supply only”.

3.24

-

-

... More
Supply & Fixing floor door stopper, with 150 mm long cover plate, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor.

51

-

-

... More
Material & Labour double action floor spring, hydraulically regulated, made up of minimum 1.25 mm thick aluminium alloy sheet, foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and directed.

20

-

-

... More
Material & Labour in repairs for PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement

9

-

-

... More
Material & Labour for 75 mm thick PCC 1:3:6 mix type C2 as in plinth protection and paving finishing cone surface even and smooth without using extra cement

103.5

-

-

... More
Material & Labour Treatment of surface under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.

1541

-

-

... More
Material & Labour Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.

103.5

-

-

... More
Supply & Fixing SS W Hinges SS 202 Grade steel Rust Resistance , for fixing cup boords shutters sizes of hinges 3" to 4" and 1.5 mm thickness, suitable for 18 mm thick cabinets shutters complete all as specified and directed

122

-

-

... More
Material & Labour for sand filling under floors or in foundations, laid in layers n exc 15 cm thick, spread levelled including watering and consolidation complete all as specified and directed

7.5

-

-

... More
Material & Labour Hard core gauge not exc. 63mm of broken bricks diposited spread and levelled in layers not exc. 15 cm watered and rammed to a true surface complete all as specified.

22.5

-

-

... More
Material & Labour 75mm thick plain cement concrete (1:4:8) type D-2, using 40mm graded stone aggregate as in sub base complete, all as specified & directed.

150

-

-

... More
Material & Labour Machine pressed, precast plain cement concrete Interlocking paver block, factoty made( with grey cement and pigment) conforming to IS-15658-2006, 80 mm thickness laid over sand cushioning layer & joints filled with sand in hardstanding etc, fabricated with M-40 grade concrete, complete all as specified and directed.

150

-

-

... More
Dismantling ceiling and wall boards or insulation board any thickness including cover fillets.

1125

-

-

... More
Material & Labour for 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh with 2mm dia GI wire to hanging and size of grid 605x605 mm Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and applying two coats of distemper oil emulsion over 01 of 2 mm thick putty over a coat of primer complete all as specifie and as directed.

1125

-

-

... More
Supply & Fixing 10mm thick PVC insulation panels with EPS stuck to 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium/G.I./M.S. as per specification

180

-

-

... More
Supply & Fixing Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre

180

-

-

... More
Supply & Fixing solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications

947

-

-

... More
Supply & Fixing 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing.

2195

-

-

... More
Supply & Fixing rolling blinds for windows including roller complete as per manufacturers instruction. (Note: Rolling blind pattern and colour shall be as directed by Engineer-in-charge)

130

-

-

... More
Supply & Fixing in repairs Vitreous China Urinal, Half stall type, 420 x 395 x 635 mm white (excluding flushing cistern, flush pipe) white (minimum), with grating and union for discharge pipe including chromium plated waste coupling, CP spreader and necessary waste pipe complete all as directed by Engineer-in-Charge.

10

-

-

... More
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as directed.

114

-

-

... More
Supply & Fixing ACP sheet of 3mm thk for parking or similar shed including necessary aluminium pipe framing complete as per manufacturers instruction. (Note: ACP sheet pattern and colour shall be as directed by Engineer-in-charge)

114

-

-

... More
Taking down carefully existing unserviceable copper/aluminium point wiring (light, fan, socket or power point etc) complete with fittings/fixures such as switches sockets, ceiling rose, fan regulators, etc ( except tube light fittings), removing materials for taking credit and making good disturbed surface of wall, floors, etc complete all as directed by Eng-in-Charge.

926

-

-

... More
M & L Point wiring complete with 1.5 sqmm single core PVC insulated (FRLS) and unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including PVC Conduit and all accessories Concealed in walls / roofs / floors / ceiling etc. and including provision of 1.5 sqmm copper cable as earth continuity conductor and connected to common earth dolly, in modular sunken boxes in wall with modular plate cover for housing the switches, socket outlets, fan regulators etc complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed for the following :-

-

-

-

... More
(a) One light point controlled by one switch.

303

-

-

... More
(b) One ceiling fan point controlled by one switch and fan regulator.

96

-

-

... More
(c) One exhaust fan point controlled by one switch

14

-

-

... More
(d) One 3 pin socket outlet 5 Amps independent board.

338

-

-

... More
(e) One 3 pin socket outlet 5 Amps on the same board with other switch.

50

-

-

... More
(f) One bell point controlled by one bell push

10

-

-

... More
(g) One light point controlled by two 2 - way switches.

6

-

-

... More
All as per item No. 2(d) here-inbefore but with 2.5 sqmm PVC insulated multistranded flexible unsheathed copper conductor inclusive of 2.5 sqmm PVC insulated multistranded flexible copper conductor for one independent 6 pin 16 Amp socket.

109

-

-

... More
Supply and fixing for Modular type switch 1 way 6A, 1module, 230 V,AC 50Hz ISI Marked with valid CML No. complete as all as specified and directed

801

-

-

... More
Supply and fixing for Modular type switch 2 way 6A, 1module, 230 V,AC 50Hz ISI Marked with valid CML No. complete as all as specified and directed

12

-

-

... More
Supply and fixing for Modular type switch 1 way 20A, 1module, 230 V,AC 50Hz ISI Marked with valid CML No. complete all as specified and directed

109

-

-

... More
Supply and fixing for Modular type socket outlet multipurpose having provision for Socket, 6A - 2/3 pin combined 2 module, 230 V, AC 50Hz ISI Marked with valid CML No. complete all as specified and directed

388

-

-

... More
Supply and fixing for Modular type socket outlet multipurpose having provision for 3 pin 16A and 3 pin 6A, 2 module, 230 V, AC 50Hz ISI Marked with valid CML No. complete all as specified and directed

109

-

-

... More
Supply and fixing for Modular type Fan step regulator electronic type, 230V,120W - 2 module ISI marked with suitable CML No and connecting upto complete all as specified and directed

96

-

-

... More
Supply and fixing for Modular type Bell push 6A, 1 module ISI marked with suitable CML No and connecting upto complete all as specified and directed

10

-

-

... More
Supply and fixing ceiling rose surface polycarbonate body three terminal.

94

-

-

... More
S & F of ceiling fan complete with blades, down rod from existing roof / truss to fall ceiling and accessories, 230V, 1200mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor including ceiling fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV ceiling fan complete all as specified and directed. Note : 1) Old ceiling fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.

96

-

-

... More
Supply & fix of exhaust fan steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed. Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.

8

-

-

... More
Supply & fix of exhaust fan steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers, voltage 230V, 50Hz, RPM 1200, copper winding complete including exhaust fan connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and taking down existing UNSV exhaust fan complete all as specified and directed. Note : 1) Old unserviceable Exhaust fans shall be deposited to AGE E/M store yard for re issue to other buildings after repair/servicing or suryed off as per procedure in vogue etc.

6

-

-

... More
S & F LED ceiling light fitting of size 600mm X 600mm, 36 Watt, 220 Volt AC recessed type with high efficiency PMMA diffuser with soft glare free light complete with drivers, holders and LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size complete including taking down old unserviceable existing light fitting complete all as specified and directed.

210

-

-

... More
Supply and fix of LED light fitting 1X20Watt, 220 Volt AC decorative box type with drivers, holders and including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete including taking down old unserviceable existing light fitting complete all as specified and directed.

69

-

-

... More
Supply and fix of LED batten tube light fitting of capacity 10 Watt, 2' long a indoor decorative LED engineering plastic batten with opal diffuser, IP20 protection complete all as specified and directed. Make :- Havells / Phillips / Wipro

11

-

-

... More
Supply and fix of Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings inclouding one LED lamp 7 Watt complete all as specified and directed

7

-

-

... More
Supply and fixing Ding Dong call bell AC, 230 Volt, single Pole complete all as specified and directed

10

-

-

... More
M & L for Sub main wiring with FRLS two run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 1.5 Sqmm size drawn through in PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends concealed in walls / roofs / floors / ceiling etc including one run of 1.5 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed NOTE : Two runs of single core 1.5 sqmm and one run of 1.5 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.

150

-

-

... More
M & L for Sub main wiring with FRLS two run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through in PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends concealed in walls / roofs / floors / ceiling etc including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed NOTE : Two runs of single core 4.0 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.

350

-

-

... More
M & L for Sub main wiring with FRLS two run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 6.0 Sqmm size drawn through in PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends concealed in walls / roofs / floors / ceiling etc including one run of 6.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed NOTE : Two runs of single core 6.0 sqmm and one run of 6.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.

350

-

-

... More
M & L for Sub main wiring with FRLS two run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 10.0 Sqmm size drawn through in PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends concealed in walls / roofs / floors / ceiling etc including one run of 10.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed NOTE : Two runs of single core 10.0 sqmm and one run of 10.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.

300

-

-

... More
M & L for Sub main wiring with FRLS four run of single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 16.0 Sqmm size drawn through in PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends concealed in walls / roofs / floors / ceiling etc including two run of 16.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed NOTE : Four runs of single core 16.0 sqmm and two run of 16.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.

400

-

-

... More
S & F for sheet metal enclosures distribution board double door,TPN vertical 8 way suitable for fixing of Four pole MCCB as in commer & MCBs SP as out going and duly fitted with Bus bar, Neutral link, blanking plates etc complete.The DB shall be included with one No MCCB, 4 pole, 415/430 Volt, 160 Amps, fixed megnatic and thermal release, having rupturing capacity 36 KA on 415 V icu. Make of DB L&T and Make of MCCB L&T Encloser & MCCB shall preferably of same make fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed. ( MCB s required for out going shall be measured and paid separately)

7

-

-

... More
S & F sheet metal enclosures (double door) for DBs where MCBs to be used single pole and neutral 8 way 240 V with 200 amps rated bus bar fixed on wall complete with all acessories including taking down old unserviceable MCB DB with MCBs complete all as specified and directed

38

-

-

... More
S & F incl connecting MCB single pole, having rupturing 10KA, 6 amps to 32 amps as ordered 240 Volts

228

-

-

... More
S & F MCB Single pole and neutral (SPN), having rupturing 10KA, 240 V 63 amps as ordered.

76

-

-

... More
S & F Modular Power unit 25 Amp unit including suitable size of sunken metal box and white cover plate including Modular Miniature Case Circuit Breaker and plug top with indicator of capacity 25 Amp complete all as specified and directed by Engr-in-Charge

35

-

-

... More
S & F wall mounted fan energy efficient 300mm plastic body sweep with pull cord 240 AC, 50 Hz, single phase with all accesseries complete all as specified and directed Make- Orient / Havells / CG / Halonix

17

-

-

... More
S & F Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in walls / roofs / floors / ceiling etc of size 20mm dia including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed.

150

-

-

... More
S & F Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc concealed in walls / roofs / floors / ceiling etc of size 32mm dia including cutting of chases where as required and making good all disturbed work to match the existing all as specified and as directed.

150

-

-

... More
S & F wall mounted GI cable tray not less than 2mm thick of Size 40 X 300mm tray for support of LT / LAN cable perforated bottom design allow for hold down attchment, cable attachements and heat dissipation complete all as specified and directed Note : Coated rate shall be deemed all fixing and jointing accessories like screw, washers, nuts and bolts etc

60

-

-

... More
S & F of engagement light wall mounting B22 type holders including red and green LED lamps complete all as specified and directed Note : Coated rate shall be deemed all fixing and jointing accessories like screw, washers, nuts and bolts etc

6

-

-

... More
Supply, install, test and commissioning of factory made cubical indoor type LT feeder piller box confirming to IP-54 complete weather proof and verminproof and the shell shall be of 2.0mm thick MS Sheet with particians and switch enclosure doors of 1.6mm and canopy made out of 2.0mm thick MS sheet all as per IS shall be available inside for easy access and working condition. It should be mounted on 40 x40 x 6mm angle frame duly painted with two coats of enameled paint on a coat of red oxide primer with a clearance of at least 0.45mtrs above FL, an appron of 2.0 mm thick MS sheet. Markings should be made to identify incoming and outgoing circuits. Outdoor feeder pillar box comprising of following :- a) MCCB, 4 pole, 630 Amps, 36KA (As Incomer) b) MCCB 4 Pole, 160Amps, 36KA- 7 Nos c) MCB SPN, 16Amps, 10KA- 1 Nos d) ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps - 1 Nos e) Digital Ammeter of range 0 - 1000 Amps with suitable capacity C.T. and selector switch - 01 Set f) Digital Voltmeter of range 0-500 Volts with selector switch - 01 Set g) Aluminimum Bus bar 3 phase 4 wire of capacity 900Amps - 01 Set h) LED phase indicating lamp - 1 Set.

1

-

-

... More
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating invertor type and EER 3.2 of capacity 1.5 TR complete all as specified and directed Note : The split AC shall carry minimum 5 star rating as per Bureau of energy Efficiency (BEE) labelling programme

10

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 04 KVA.

10

-

-

... More
Supply, Install testing and commissioning of 200KVA Diesel Engine driven generating set with acoustic enclosure made out of CRCA Sheet powder coated specially designed lifting arrangement/hooks, meet the latest CPCB norms of 75 DBA from 1 mtr distance and as per the testing guideline if CPCB, DG Set shall be confirming to IS 10001/10002 and alternator as per IS 13364, coolant type, self-starting system with 12 volt DC Supply, 3 Phase, 4 wire AC 415 volt - 5% at 1500 RPM, 50 Hz, self exited self regulated, Automatic voltage regulation Class 'H' insulated type alternator installed on PCC foundation. The following accessories shall be confirmed (a) Coupling arrangements and (b) Mounting arrangements with ISMC fabricated frame on anti-vibration pad. (c) Fuel tank with base frame suitable for not less 8 pers Running capacitor on full load, inlet & outlet arrangement with air vent level indicator, drain plug arrangement and provision for cleaning.

1

-

-

... More
(d) Battery maintenance free dry cell battery 12 Volt 120 A of approved make. (e) Water Pump (f) Radiator with (g) Silencer muffler as per approved norms of CPCB (h) LT Panel electronic modular type for DG Set floor mounted cubical 2mm thick powder coated finish indoor type with the following arrangements - (j) Indicating lamp LED type for "Load on" & Set Running on - 01 Set (k) Ammeter with selected switch digital type suitable to Lead phase (l) Volmeter with selector switch digital type suitable to read Phase Voltage and voltage (multifunction) all as specified (m) Hours Run meter digital type to read cumulative and present running Hrs. (n) RPM indicator digital type- 01 No

-

-

-

... More
(o) Frequency meter digital type- 01 No. (p) Earthing terminals- 2 Nos (q) Digital Manual and AMF control panel : Digital Manual is equuiped with 16 bit hogh spedd RISC processor based controller. It display the following parameters Safty System with special sensors to safe guard the engine aginst faults, like low lub oil pressure, high coolant temperature, battery over/under/weak volt, fail to crank/start, sensor failure, over spedd, low fuel level etc with alarm. (r) AC Alternator protection Over/Under Voltage, Over/Under Frequency. (s) ' Present system with push button'. (t) DC Voltmeter- 01 no (u) Mechanical Governior.

-

-

-

... More
(v) Reverse power relay & reverse reactive power relays. (w) Netural switching facility. (x) SMOS suitable for charging 12 volts with trickle and boost facility- 01 No (y) Independent earthing terminals for engine & alternator- 02 each. (z) Battery charging alternator 12 volt (aa) M & L for making PCC Foundation (1:3:6) type B1 using 20 mm graded rendering in CM(1:6) surface even and smooth Flooring PCC(1:3:6) type B1 using 20 mm graded stone aggregate 100 mm thick hard core over rammed earth for 100 KVA DG Set complete all as specified and as directed.

-

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 320x06 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.