Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 64,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_665884_1Bid Award Id
ViewTender No
8773/VAL/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item No. 2 here-in-above but for manholes of depth exceeding 2.00 m but not exceeding 4.50 m.
53
-
-
... More
Cleaning of septic tank, filter bed/ soakage well and inspection chambers of any size and depth, getting out sludge (solid/ semisolid), bailing out water by mechanical equipment or manual and other accumulated materials complete, washing with the water and disposal of sludge to outside MD land in closed vehicle complete all as directed. Note : Quantity of cleaned dry solid per cum shall be measured and paid. The stack measurements are to be taken as final quantity.
50
-
-
... More
Cleaning of 100 mm bore blocked Sewage lines in any depth by pressure Jet by using mechanical/ hydraulic pressure using Vehicle type hydraulic methods or modern methods and/ or manually such as by rodding, passing rope knots, bamboo fanti and disc of required size (with safety measure for gas etc) from manholes to manholes or manholes to cleaning eye or cleaning eye to clean eye until the smooth flow of sewage line is restored including taking out sludge in semi liquid stage including all water effluences etc re-fixing manhole cover and removing all materials from the site of work to outside MD land in closed vehicle and depositing in excavated earth pit of suitable size including supply and sprinkling bleaching powder and covering sludge with earth after removal of blockage etc complete all as directed.
Note : Quoted rate shall deemed to be inclusive of earthwork & excavation, sprinkling sufficient bleaching powder including transporting the sludge & other materials in closed vehicle.
120
-
-
... More
All as per item No. 6 here-in-above but 150 mm bore sewage line.
3800
-
-
... More
All as per item No. 6 here-in-above but 200 mm bore sewage line.
1620
-
-
... More
All as per item No. 6 here-in-above but 300 mm bore sewage line.
290
-
-
... More
Bailing out water from existing septic tank of 500 users capacity and filter bed including inspection chamber and getting out sludge and other accumulated materials complete by manually or using the machinery for work in foul position or in liquid mud and disposal from site all as directed, including refilling with water all as directed.
Notes : (i) Sludge shall be disposed off outside MoD land in closed container and quoted rate shall deemed to be inclusive of disposal outside MoD land (ii) The place of disposal of sludge shall be selected by the contractor outside of MoD land under his own arrangement. Government shall not pay compensation for the land and also no extra payment is admissible to the tenderers due to interference by civil authorities. Contractor requires disposing the sludge on any place or places other than that selected by him. Nothing extra shall be admissible on this account.
4
-
-
... More
All as per item No. 10 here-in-above but Septic tank of 250 users capacity.
3
-
-
... More
Demolition of brickwork/PCC block or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
37.25
-
-
... More
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MoD land complete all as directed.
22.5
-
-
... More
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for in this Schedule and removal of entire debris as ordered outside MoD land complete all as directed.
16
-
-
... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
11
-
-
... More
Demolition and breaking up drain pipes (Salt glazed stone ware, AC or Reinforced concrete) of 150 mm internal dia set in cement mortar including bedding and haunching complete all as specified and as directed
490
-
-
... More
All same as per serial item No. 16 here-in-above, but 200 mm bore.
329
-
-
... More
All same as per serial item No. 16 here-in-above, but 300 mm bore.
95
-
-
... More
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
225
-
-
... More
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in hard/ dense soil complete all as specified and as directed.
72
-
-
... More
All as per item No. 20 here-in-above but exc 1.5 m and not exc 3.0 m in depth -do-
35
-
-
... More
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
170
-
-
... More
Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed.
162
-
-
... More
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
12.75
-
-
... More
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.
5.25
-
-
... More
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed.
37.75
-
-
... More
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed.
12
-
-
... More
M&L for precast RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in landings, cover slabs (for man holes, drains etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including placing in position and set in CM (1:4) complete all as specified & as directed.
Note :- Reinforcement shall be measured and paid for separately under respective item of this Schedule.
11
-
-
... More
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
1230
-
-
... More
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed.
Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
60
-
-
... More
M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.
160
-
-
... More
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
15
-
-
... More
M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed.
Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
40
-
-
... More
M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE.
80
-
-
... More
M&L for machine pressed coloured chequered cement concrete tiles of size 295x295x25 mm thick with grey cement and pigments, set and jointed in neat cement slurry in floors and pointed with coloured cement to match the shade of tiles and laying over & including 15 mm thick screed bed in CM 1:6 complete all as specified.
Notes: (i) Quoted rate shall deemed to be inclusive of cement screed. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.
90
-
-
... More
M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified and as directed.
305
-
-
... More
S&F in repairs 100 mm bore Cast Iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.
20
-
-
... More
S&F in repairs 100 mm bore Cast Iron, sand cast, soil, waste and vent pipes (ISI marked) in any length with or without ears, fixed with cement joints, fixed to walls, complete all as specified and as directed.
110
-
-
... More
S&F in repairs 75 mm bore Cast Iron, sand cast, soil, waste & vent pipe (ISI marked), in any length with or without ears, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.
5
-
-
... More
S&F in repairs 75 mm bore Cast Iron, sand cast, soil, waste and vent pipes (ISI marked) in any length with or without ears, fixed with cement joints, fixed to walls, complete all as specified and as directed.
130
-
-
... More
S&F in repair 100mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval acess door complete all as specified and as directed.
20
-
-
... More
S&F in repair 75mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval acess door complete all as specified and as directed.
25
-
-
... More
S&F in repair 100mm bore cast iron branch piece, 'Y', 'T', single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door complete all as specified and as directed.
15
-
-
... More
S&F in repair 75mm bore cast iron branch piece, 'Y', 'T', single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door complete all as specified and as directed.
12
-
-
... More
S&F in repair 100mm bore Cast Iron vent cowl complete all as specified & as directed.
8
-
-
... More
S&F in repair 75mm bore Cast Iron vent cowl complete all as specified & as directed.
8
-
-
... More
S&F in repair 75 mm diameter of outlet Cast iron floor trap with openable SS grating including jointing to waste pipe, fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed.
6
-
-
... More
S&F in repairs 75mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed.
7
-
-
... More
S&F in repairs 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.
32
-
-
... More
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed.
7
-
-
... More
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.
35
-
-
... More
S&F in repair 75mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
8
-
-
... More
S&F in repair 110mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
7
-
-
... More
S&F in repair 75mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
5
-
-
... More
S&F in repair 110mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
5
-
-
... More
S&F in repair 75mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
7
-
-
... More
S&F in repair 110mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
5
-
-
... More
S&F in repair PVC (SWR) Vent cowl 75mm bore size fixed complete all as directed.
7
-
-
... More
S&F in repair PVC (SWR) Vent cowl 110mm bore size fixed complete all as directed.
7
-
-
... More
S&F in repair PVC (SWR) gully trap 125/110 mm including jonting with solvent cement complete all as specified & as directed.
7
-
-
... More
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore drain pipe complete all as specified and as directed.
Note : Drain pipe shall be measured and paid for separately.
478
-
-
... More
All as per serial item No. 61 here-in-above, but for 200mm bore pipe -do-
312
-
-
... More
All as per serial item No. 61 here-in-above, but for 300 mm bore pipe -do-
92
-
-
... More
S&F salt glazed stone ware drain pipes of 150mm bore, Class ‘SP 2’, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified & as directed.
85
-
-
... More
S&F salt glazed stone ware drain pipes of 200mm bore, Class ‘SP 2’, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified & as directed.
29
-
-
... More
M&L for Reinforced concrete pipe 150 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed.
405
-
-
... More
M&L for Reinforced concrete pipe 200 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed.
300
-
-
... More
M&L for Reinforced concrete pipe 300 mm bore, Class NP2 with collars, laid to slope in trenches & jointed in cement mortar (1:1) and tested on completion, complete all as specified and as directed.
95
-
-
... More
M&L for cutting into existing manholes/Septic tank for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate), reforming benching as required and finishing surface even & smooth for 150mm bore pipe complete all as specified and as directed.
8
-
-
... More
All as per serial item No. 69 here-in-above, but for 200 mm bore pipe -do-
7
-
-
... More
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, including lime concrete bedding and making good disturbed floor, complete all as specified and as directed.
8
-
-
... More
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, complete all as specified & as directed.
12
-
-
... More
Fixing only in repairs vitreous china wash down water closet pan (EWC) (Pedestal pattern), including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., (excluding fixing bolt, flushing cistern, flush pipe), complete all as specified & as directed.
15
-
-
... More
Supply and laying of instant ready mix premixed bituminous material for repairing depression on pot holes, material consisting of modified all-weather bitumen paste in liquid asphalt with chemicals, anti-stripping agents, graded aggregates & additives / granular material 5-20mm crushed stone aggregate with 5.5% of bitumen, in 25 Kg bag, laid as per manufacturer’s instructions including preparation of surfaces, complete all as specified & as directed. Make: ‘ShaliPatch’ of STP Ltd or equivalent as approved by GE.
Note : The unit of measurement and payment purpose is ‘Per Bag’ of 25 Kg ready mix material.
15
-
-
... More
Cutting and cleaning of vegetation, tree, grass and fencing above ground level for sewage line inspection & line cleaning including removal of entire debris/ vegetation outside MoD land complete all as directed.
150
-
-