Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Date6 Dec 2024
Tender Amount₹ 46,60,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise complete all as specified and directed.

6.16

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed.

310

-

-

... More
Dismantling and taking out of existing panel including disconnecting cables etc complete all as specified and directed.

6

-

-

... More
Design, supply, Installing, Testing and commissioning of factory made LT cubical Double door pannel with roof canopy, outdoor type, size not less then 2000mmx1500mmx450mm, made out of CRCA sheet 3.15 mm thick duly powder coated 7 tank treatment with siemens grey shade RAL7032, totally enclosed dust and vermin proof outer cubical. Inner cubical should be made out of 2mm thick CRCA sheet with working voltage of 415 volt, 50 Hz, 3 phase 4 wire fully compartmentallized design with single door system for each compartment for each control gear with provn of both side cable alley for outgoing cables. outer cubical must be extendable in both ends having both sides door openable and shall be provided with suitable louvers for ventilations. The Bus bar ratings shall be minimum 4 nos and each have 1.5 times of incomer MCCB i.e 1000 Amps. Bus bar provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shreankable sleeve for phase indication. The standard phase arrangement when facing the swichgear shall be R-Y-B from Left to Right.

2

-

-

... More
The Bus bar connections and their insulated supports shall be mechanically strong and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuating in temp, short circuit or other causes. The Bus bar will be supported on DMC. Provision shall be made for expansion and contraction of the Bus bar and connection with variation of Temp. internal wiring shall be done with 2.5 sqmm multistranded copper conductor and shall be properly bunched, tied, ferulled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves etc. the bottom of pannel shall contain detachable plate having provision for entry of armoured cable of adequete size with glands. Threaded earthing studs-02 nos shall be provided at the bottom and lifting lugs of suitable size at top to left the panel safely shall be made. the quible in comer MCCB as well as outgoing shall have TPN/TP extension ling of current rating not less than 1.5 times the rated capacity of indivisual feeders. The cubicle shall be inclusive of following

-

-

-

... More
LOCATION- PALACE SUBSTATION, NEAR OSAKA building

-

-

-

... More
INCOMING- (a) MCCB FP, , 630 Amps 50 KA with Micro processor release, Ics=100% Icu, Adjustable over load setting: 0.8-1.0xIn, Adjustable short circuit setting: 6-10x In with spreader Terminals and rotary handle-01 No Make-L&T/Havells/Siemens/ABB

-

-

-

... More
OUTGOING- (a) MCCB TP, 36 KA, 350 AMPS with thermal magnetic release, Ics=100%Icu, Adjustable over load setting: 0.8-1.0xIn,Adjustable short circuit setting: 6-10xIn with spreader Terminals and rotary handle Make- L&T-CAT NO-CM94005OOR1OG or equivalent in ABB/Siemens/HAvells-02 No (b) MCCB TP, 36 KA, 250 AMPS with thermal magnetic release, Ics=100%Icu, Adjustable over load setting: 0.8-1.0xIn,Adjustable short circuit setting: 6-10xIn with spreader Terminals and rotary handle Make- L&T-CAT NO-CM94005OOR1OG or equivalent in ABB/Siemens/HAvells-02 No (c) MCCB TP, 36 KA, 200 AMPS with thermal magnetic release, Ics=100%Icu, Adjustable over load setting: 0.8-1.0xIn,Adjustable short circuit setting: 6-10xIn with spreader Terminals and rotary handle Make- L&T-CAT NO-CM94005OOR1OG or equivalent in ABB/Siemens/HAvells-03No (d) MCCB TP 16 KA 63 Amp with thermal magnetic release -1 Nos (e) LED INDICATORS RIBBED LENS WITH trimmed collar- Red, Yellow and Blue-03 Each (f) Digital Ammeter 630 Amp alternating current range selector switch suitable for line currents including 3Nos CT of ratio 630A/5A-01 Nos (g) Digital Voltmeter alternating current voltage range 0-500V selector switches suitable for voltage between phases with OFF-01 Nos. (h) Aluminium bus bar 1000 AMPS rating for R-Y-B phases and neutral-Sets (j) Base frame for cubical for mounting made out of 40x40x6mm equal angle iron duly painted. (k) Foundation for the panel shall provided with PCC 1:2:4 at a depth of 150 MM below G.L. and 500mm above the G.L. with slot opening for I/C and O/G cables

-

-

-

... More
Design, supply, Installing, Testing and commissioning of factory made LT cubical Double door pannel with roof canopy, outdoor type, size not less then 2000mmx1500(H) x 450mm(W) made out of CRCA sheet 3.15 mm thick duly powder coated 7 tank treatment with siemens grey shade RAL7032, totally enclosed dust and vermin proof outer cubical. Inner cubical should be made out of 2mm thick CRCA sheet with working voltage of 415 volt, 50 Hz, 3 phase 4 wire fully compartmentallized design with single door system for each compartment for each control gear with provn of both side cable alley for outgoing cables. outer cubical must be extendable in both ends having both sides door openable and shall be provided with suitable louvers for ventilations. The Bus bar ratings shall be minimum 4 nos and each have 1.5 times of incomer MCCB i.e 800 Amps. Bus bar provided shall be adequately supported on insulators to withstand dynamic stresses due to short circuit current and shall be suitably colour coded with heat shreankable sleeve for phase indication. The standard phase arrangement when facing the swichgear shall be R-Y-B from Left to Right.

4

-

-

... More
The Bus bar connections and their insulated supports shall be mechanically strong and shall with stand all the stresses which shall be imposed upon them in ordinary working due to fixing, vibration, fluctuating in temp, short circuit or other causes. The Bus bar will be supported on DMC. Provision shall be made for expansion and contraction of the Bus bar and connection with variation of Temp. internal wiring shall be done with 2.5 sqmm multistranded copper conductor and shall be properly bunched, tied, ferulled for proper identification, crimped and shall be connected with suitable lugs and PVC sleeves etc. the bottom of pannel shall contain detachable plate having provision for entry of armoured cable of adequete size with glands. Threaded earthing studs-02 nos shall be provided at the bottom and lifting lugs of suitable size at top to left the panel safely shall be made. the quible in comer MCCB as well as outgoing shall have TPN/TP extension ling of current rating not less than 1.5 times the rated capacity of indivisual feeders. The cubicle shall be inclusive of following

-

-

-

... More
LOCATION- Pechora faculty, 57 ASP MT, Near OMQ 6, Near W05, Near B1 Old

-

-

-

... More
INCOMING- (a) MCCB TPN, 36 KA, 400 Amps with thermal magnetic release, Ics=100% Icu, Adjustable over load setting: 0.8-1.0xIn, Adjustable short circuit setting: 6-10x In with spreader Terminals and rotary handle-01 No

-

-

-

... More
OUTGOING- (a) MCCB TP, 36 KA, 250 AMPS with thermal magnetic release, Ics=100%Icu, Adjustable over load setting: 0.8-1.0xIn,Adjustable short circuit setting: 6-10xIn with spreader Terminals and rotary handle Make- L&T-CAT NO-CM94005OOR1OG or equivalent in ABB/Siemens/Havells-01 No (b) MCCB TP, 36 KA, 200 AMPS with thermal magnetic release, Ics=100%Icu, Adjustable over load setting: 0.8-1.0xIn,Adjustable short circuit setting: 6-10xIn with spreader Terminals and rotary handle Make- L&T-CAT NO-CM94005OOR1OG or equivalent in ABB/Siemens/HAvells-03 No (c) MCCB TP, 36 KA, 160 AMPS with thermal magnetic release, Ics=100%Icu, Adjustable over load setting: 0.8-1.0xIn,Adjustable short circuit setting: 6-10xIn with spreader Terminals and rotary handle Make- L&T-CAT NO-CM94005OOR1OG or equivalent in ABB/Siemens/HAvells-03 No (d) MCCB TP 16 KA 63 Amp with thermal magnetic release -1 Nos (e) LED INDICATORS RIBBED LENS WITH trimmed collar- Red, Yellow and Blue-03 Each (f) Digital Ammeter 630 Amp alternating current range selector switch suitable for line currents including 3Nos CT of ratio 630A/5A-01 Nos (g) Digital Voltmeter alternating current voltage range 0-500V selector switches suitable for voltage between phases with OFF-01 Nos. (h) Aluminium bus bar 1000 AMPS rating for R-Y-B phases and neutral-Sets (j) Base frame with stand height 500mm for cubical for mounting made out of 50x50x6mm equal angle iron duly painted. (k) Foundation for the panel both side of corner shall provided with PCC 1:2:4 at a depth of 300 MM below G.L. and 400 mm above the G.L. ( stand should be grouted in PCC plateform

-

-

-

... More
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI strip 32x6mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed

14

-

-

... More
Supply install testing and commissioning of LT cable junction box outdoor type "weather proof polycarbonate/ABS with locking arrangements fixed on poles of size 290x200x130mm suitable for connecting XLPE 10-25 Sqmm cable including 4 nos 100 Amp connector and MCB 20 A -03 Nos all as specified and directed. Make HenselCat No 2500G/ IDIS India/ Naptune

10

-

-

... More
S&F PVC insulated PVC sheathed, weather proof 3 core size 1.5 sqmm stranded copper wire complete all as specified and directed.

330

-

-

... More
S&F cross arms, bracing,supports clamp and back plates fabricated from structural steel incl nut, bolts, washers, welding, bending, drilling holes for bolts in any shape or size complete all as specified and directed.

0.5

-

-

... More
S&F pole mountable Cubical box, out door type, size 400mmx 450mm x 200mm, made out of CRCA sheet duly powder coated IP 54 protection in front of openable outdoor Panel having IP 54 protection 3.15MM thick cabinet powder coated with 7 tanks process with locking arrangements complete power wiring with 10 sqmm signle core PVC insulated solid Copper cable having following accesories :- (a) Astronomical time switch (for Street Lights) with 2 NO+2NC, 365 days time zone with Real Time clock (b) Power Contactor of 63 Amps 4 pole with short circuit current and over current protection (c) Isolator of 63 Amps 4 pole (d) Out going MCB SP 25-40 Amps - 6 Nos (e) Connector 100 Amp for Incomming and out gong . Make of accesories : Havells/L&T/Standard

2

-

-

... More
M&L for Earthing with galvanized steel earth plate electrode 60x60cmx6mm thick, buried directly in ground (earth pit not less than 2.25 meter below normal ground level) with top edge of earth plate not less than 1.5 meter below normal ground level connected to main earth lead of GI wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part-I 1991, GI earth lead protected by providing GI pipe 20 mm dia light grade and connected to earth test point with & including necessary excavation & earth work in any type of soil, returning filling, disposal of surplus soil upto 50 meter, filling with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, PCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point, commissioning & testing complete. (Note : Main earth lead beyond 7.5 meter measured and paid for separately).

4

-

-

... More
S&F Energy saving, environmental friendly long life, Challenger Pro Plus Unique modular LED flood light 500W made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP 66 protection available in NB/MB/WB angles system efficacy -110/125/135 LPW, 10 KV SPO complete all as specified and directed.

36

-

-

... More
Excavation in trenches not.exc 1.5m wide and not exceeding 1.5m in depth by manual digging for laying of cable in underground in trnches not exceeding 10 Sqm on plan and not exceeding 1.5mtr in depth and getting out in hard/dense soil complete all as specified and as directed.

107

-

-

... More
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed.

55

-

-

... More
Supply, Laying, commissioning and testing of UG LT cable XLPE insulated screened PVC bedded, galvanized steel strip armoured, electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 240 sqmm 3.5 core including connecting the cables at both ends by providing suitable size aluminium lugs at the termination ends complete all as apecified and directed.

310

-

-

... More
Supply and laying or fixing or passing through pipe XLPE insulated 1100 volt grade underground cable with aluminium conductor armored with steel strip or wire cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.

250

-

-

... More
M&L for boring of holes under road,pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.

25

-

-

... More
Supply and fixing of Galvanised steel tubes, light grade 40mm dia for cable protection laid in pole coping , on wall/ under the road complete all as specified.

20

-

-

... More
S & F MCCB 4 Pole, 415 V, Thermal Adjustable type, 250 Amps with breaking capacity 36 KA including providing neccesary connection complete all as specifed and as directed.

1

-

-

... More
Supply,installation,testing and commissioning 3 phase and neutral , 415 volts out door type , CPRI approved, factory made free standing ,dust and vermin proof, cubical type LT Feeder Pillar fabricated from 3.15 mm thick CRCA sheet for outer shell and 2.0 mm for inner shell, with angle iron frame of 50 x 50 x 6 mm , double door , front and back openable type, double door system, hinged opening , rubber lining,locking arrangement,with anticorrosive coating and finally epoxy polyester power coating with pure polyster Siemens grey structural RAL-7032 shade , protection class IP-54 fully compartmentalize design with 4 nos of bus bar made of copper of ETP grade suitable for 400 Amps ( Size of copper strip should not be less than 25x4 mm for each phase and neutral) pre-wired with suitable size of copper strip with colour code for connecting out going MCCB/ MCB`s, including suitable aluminium earth strips conforming to IS with danger notice plate , necessary cable glands, cable connection with proper lugs ,PCC foundation and pedestal for fixing piller feeder box with PCC 1:5:10 , 15 cm thick in foundation , brick (Fly ash) / PCC block work in CM 1:6 , rendering 1:6 on exposed surface and 100 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in padding on top and grouting bolts etc for panel. The plateform shall be of 1000 mm height above ground level all as specified with supply and fixing the following.

1

-

-

... More
(A) Incoming : (i) Change over, open execution type 400 Amps 4 Pole, with operating handle - 01 Nos

-

-

-

... More
(ii) 4 nos of Copper bus bars of size not less then 25 x 4 mm for each phase having 400 Amps current rating capacity made of copper of ETP grade. - 01 set

-

-

-

... More
(B) Outgoing : (i) MCCB 200 Amp ,4 Pole, 36 kA, 415 volts, AC, 50Hz thermal adjustable type for overload 0.64 to 1.0 and adjustable magnetic release (3.5 to10.0 In ) for short circuit with Extended rotary handle vari- depth type and sapreater between phases and neutral -01 Nos

-

-

-

... More
(ii) MCCB 125 Amp ,4 Pole, 25 kA, 415 volts, AC, 50Hz thermal and magnetic adjustable type for overload 0.64 to 1.0 and adjustable magnetic release (3.5 to10.0 In ) for short circuit with Extended rotary handle vari- depth type and sapreater between phases and neutral -03 Nos.

-

-

-

... More
(c) Metering Compartment

-

-

-

... More
(ii) Digital 3 Phase Ammeter, Flush mounting, 96 x 96 mm, Accuracy class 1.0, with inbuilt selector switch for three phase, CT/PT site programable ---01 Nos with Suitable CT as per MCCB and wiring with copper wire.

-

-

-

... More
(iii) Digital 3 Phase Voltmeter, Flush mounting, 96 x 96 mm, Accuracy class 1.0, with inbuilt selector switch for three phase, CT/PT site programable- 01 No

-

-

-

... More
(iv) Three indication lamps- 01 Set (Red, Yellow, Blue).

-

-

-

... More
Dismentling and taking out old unserviceable search lights and supply and fixing of Hi-intensity, long beam, LED search light 300W multi circuit SMD, focus range 800Mtr, CCT 5500K LM6 body dia 440mm, operating voltage :90V-300V,50Hz PF.95,THD 70 Optics used-PMMMA/PC lens narrow beam 7 degree average lux level9000 with circuit of approx, 1 Mtr toughened with silicon gasket, over/under volt and short circuit protection confirmating to LM79, LM 80, IK07, IP66, Lux Cert, Type tested IS 10322, IS 15885 and B.I.S. suitable to be installed on existing rotating disc of revolving Mechanism of Kaline complete all as specified and directed.

22

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.