Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 77,520Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684162_1Tender No
8235/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(i) Incoming (Main) :- One numbers MCCB 800 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz with thermal magnetic release adjustable lcs=100% lcu against overload setting connected through suitable size copper bus bas coated with insulating sleeves.
-
-
-
Outgoing:- (i) Six Numbers MCCB 350 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz.
-
-
-
(ii) Three Numbers MCCB 250 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
-
-
-
(iii) One Number MCCB 125 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
-
-
-
(iv) One Numbers of panel mounted on-load AC changeover connected through suitable size of copper bus bar coated with insulating sleeves capacity of 400 Amps, 415 Volt, 4 pole, 50 Hz
-
-
-
Supply, errect, test and commissioning LT Panel out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 2 mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 800 Amps capacity insulated, Digital ammeter 0-1000 amps, with CTs, Digital voltmeter 0-1000 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation comprising the following:- size -- approx (1.5 x 1x 0.5Mtr)
2
-
-
(i) Incoming (Main) :- One numbers MCCB 350 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
-
-
-
Outgoing:- (i) Two Numbers MCCB 250 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
-
-
-
(ii) Two Numbers MCCB 160 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
-
-
-
(iii) Two Numbers MCCB 100 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
-
-
-
Supply, errect, test and commissioning LT panel out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 3.15 mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 600 Amps capacity insulated, fixed with epoxy based Digital ammeter 0-500 amps, with CTs, Digital voltmeter 0-500 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation minimum 60cm from normal ground level comprising the following:- size - approx (1 x 1x 0.5Mtr)
4
-
-
(i) Incoming (Main) :- One numbers MCCB 250 amp, 4 pole, Ics 50 KA, 415 volts, 50 Hz
-
-
-
Outgoing:- (i) Six Numbers MCCB 125 amp, 4 pole, Ics 16 KA, 415 volts, 50 Hz
-
-
-
Supply, errect, test and commissioning Bus bar LT panel out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 3.15 mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 400 Amps capacity insulated, fixed with epoxy based Digital ammeter 0-500 amps, with CTs, Digital voltmeter 0-500 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation minimum 60cm from normal ground level comprising the following:- Size (Approx 0.9 x 0.7x 0.45 Mtr)
4
-
-
One numbers MCCB 250 amp, 4 pole, Ics 50 KA, 415 volts, 50 Hz Make Legrand
-
-
-
Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 100 KVAR (Cost of incoming MCCB will be measured and paid separately.
2
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including cable glands,cable lugs of following size ;-
-
-
-
185 sq mm 3.5 core
150
-
-
120 sq mm 3.5 core
150
-
-
95 sq mm 3.5 core
300
-
-
70 sq mm 3.5 core
300
-
-
50 sq mm 3.5 core
200
-
-
35 sq mm 3.5 core
250
-
-
25 sq mm4core
250
-
-
16 sq mm 4 core
500
-
-
10 sq mm 4 core
500
-
-
Excavation in trenches in any type of hard/dense soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
702
-
-
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
631.8
-
-
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
70.2
-
-
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and directed
1500
-
-
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 77 mm and inner dia 63 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and directed
500
-
-
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 120 mm and inner dia 103 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and directed
600
-
-
M&L for disconnecting and taking down exising serviceable cables of any size and any type carefully, shifting and relaying in new location and connectiong complete with new cable lugs, thimbles, nut bolts and jointing all as specified and as directd Note: Excavation and earthwork will be measured and paid saperately under relavent items.
300
-
-
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
3
-
-
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
3
-
-
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
2
-
-
Supplying and fixing MCCBs 160 amp, 4 pole, with breaking capacity 36 K Complete all as specified and directed
5
-
-
Supplying and fixing MCCBs 250 amp, 4 pole, with breaking capacity 36 KComplete all as specified and directed.
6
-
-
M&L for detection and locating of cable fault in underground damaged LT cable any size of any length and any type using cable fault detector/ locator machine of accuracy to 2 meters , vehicle mounted for various locations under GE(A) Ahmedabad including necessary excavation & earthwork in any type of strata of size required for visually inspection/repairing the damaged cable when and where directed
8
-
-
S&F steel tubes light grade galvanized 100 mm bore ISI marked with all fittings fixed to walls / floors / road crossing, poles as required.
12
-
-
M&L Labour & tools for horizontal boring through road / path / floor for passing UG cables by using trench less technology for laying upto 100mm dia GI pipe complete all as required. Note : GI pipe will be measured and paid seperately.
20
-
-
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
16
-
-
Dismantling existing serviceable MCCB/ HRC Fuses/LBS from existing Panel & refixing in new location all as specified and directed.
20
-
-
Dismantling old u/s LT Panel with bus bar & connections, u/s panel meters and accessories except MCCB/HRC Fuses.
25
-
-
Dismantling old u/s MCCB/HRC Fuse/ LBS etc:-
-
-
-
old u/s MCCB from 32 Amp to 200 Amp
5
-
-
Old u/s MCCB 200A to 400 Amp
5
-
-
Old u/s HRC Fuse.
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%