Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 52,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_687076_1Tender No
8019/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in soft/ loose soil, for laying of under ground electric cable, pipes etc complete all as specified and directed.
230.85
-
-
... More
Material and labour for river bed sand filling in trenches/ ducts 15 cm above cable and 8 cm under the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed.
69.26
-
-
... More
Supply and laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over under cable for protection complete all as specified and directed.
5700
-
-
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layer not exceeding 25cm thick each complete all as specified and directed.
153.04
-
-
... More
Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed.
77.81
-
-
... More
Material and labour for laying 100 mm bore GI pipe, light grade with all fittings, in crossing road/path and in pole up to junction box including necessary clamping etc. complete all as specified and directed.
Note :- Boring under road/path will be measured and paid under respective item.
60
-
-
... More
Material and labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
45
-
-
... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 120 -150 sqmm,Indoor/Outdoor type complete all as specified and directed.
2
-
-
... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3.5 core XLPE, armoured, Al conductor cable of size 185-240 sqmm,Indoor/Outdoor type complete all as specified and directed.
2
-
-
... More
M & L in replacement of earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32x6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of HDPE protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete all as specified and directed. Note: G I strip exceeding 7.5m long shall be measured & paid seperately.
4
-
-
... More
Supply, installing, testing and commissioning, in repair factory made and tested LT Panel, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door and locking arrangement and including earth work. The panel consisting of the following:- (a) Aluminum bus bar four strips 300 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.
(b) MCCB, 04 Pole, 200 Amps with ultimate breaking capacity 36 KA - 01 No (Incoming) (c) MCCB, 04 pole, 100 Amps with breaking capacity 25 KA - 01 Nos (d) MCCB, 04 pole, 63 Amps with breaking capacity 25 KA - 02 Nos (e) MCCB, 04 pole, 40 Amps with breaking capacity 25 KA - 02 Nos (f) Euroload changeover switch 415 volts (4pole) 200 Amps - 01 Nos (g) Digital Volt meter 0-500 volt with coil and selector switch - 1 No.
(h) Digital ammeter 0-500Amps with CT coil and selector switch - 01 No
(j) Indication lamps R,Y,B LED type – 1 set of three (k) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
(l) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, cemented block/brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 30cm above and 15 Cm below the ground level. -Compartmentalized Panel Dimensions (870mmx1970mmx450mm)(W*H*D)
1
-
-
... More
Supply fabricate, testing and commissioning of factory made LT outdoor busbar panel single door of size 1200mm x 800mm x 400mm including locking arrangement cubical type dust and virmin proof, weather proof, aesthetical designed, IP54 degree of ingress protection, fabricated with 3.15mm thick CRCA sheet with front and rear opening including 4 strips of alluminium bus bar of 300 Amps current carrying capacity insulated with colour sleeves, porcelain/epoxy insulators 1100V, rail channel, cable entry, danger notice plate of 1100 Volt, angle iron frame of size 50x50x6mm and 60cm grouted in ground and 90cm above GL including necessary excavation, foundation, PCC etc. complete duly powder coated of approved colour complete all as specified and directed .
1
-
-
... More
Supply and fix in replacement of Intelligent Addressable fire alarm control panel with one Loop complying with EN 54 standard & LPCB approved and battery back up with the specifications as appended below:-
a) Power- AC 230V, 50Hz, 0.5 A
b) 235 Devices including detectors, minimum 2 loop,
c) Relay- Fire Alarm/ F.P.E/ Fault/ Sounder
d) configurable for PC Port- RS-232 interface & communication card
e) LCD Display and with battery backup of 24 Hours in non alaram condition and 15 Minutes in alaram condition (Battery type 2 X 12V 14AH, sealed type
Make of Battery- Exide/Amron/Solance.
Make: Honeywell/Gulf Security Technologies/AGNI/EST
1
-
-
... More
Supply and fix in replacement of electronically addressable intelligent combination of heat and photo electric smoke Multi detector with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-
a) Power- 24V, ≤ 0.8 mA (Standby Current) ≤5.0mA (Alarm Current)
b) Class A2R,
c) Indicator- Red Flashes in normal and illuminates in alarm,
d) Ingress Protection IP-22 & Material-ABS
Make: Honeywell/Gulf Security Technologies/AGNI/EST
55
-
-
... More
Supply and fix in replacement of electronically addressable intelligent Sounder Cum strobe with mounting base, continuous normal operation for atleast 50 minutes with sound level 65db- 120db measured at 1.5m with sound output variation +5db complying with the specifications as appended below:-
a) Power-12/ 24 V DC or 110 /220V AC, 1Ph, AC, 50Hz
b) Range-1000 m
c) visual indication.
Make: Honeywell/Gulf Security Technologies/AGNI/EST
16
-
-
... More
Supply and fix in replacement of intelligent loop isolator with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-
a) Power- 24V, ≤ 3 mA (Standby Current) ≤15mA (Action Current)
b) Class A ,
c) Initiating Mode- Yellow flashes when polling, illuminates in action,
d) Ingress Protection IP-30 & Material-ABS
Make: GST/Bosch/Siemens
5
-
-
... More
Supply and fix in replacement of electronically addressable intelligent resettable type manual call point with mounting base complying with EN 54 standard and LPCB approved with the specifications as appended below:-
a) Power- 24V, ≤ 0.6 mA (Standby Current) ≤1.8mA (Alarm Current)
b) Class A ,
c) Initiating Mode- Pressing the action plate manually Resuming Mode-Manually Resumed by a special Key,
d) Ingress Protection IP-43 & Material-ABS
Make: Honeywell/Gulf Security Technologies/AGNI/EST
15
-
-
... More
Supply and fix in replacement of programming card for programming of detectors and other devices in FACP Comm.Interface: USB interface
Comm.Distance <15m <5m
Baud Rate 2400bps
Ambient Temperature 0℃~+40℃
Relative Humidity ≤95%, non condensing. Make: Honeywell/Gulf Security Technologies/AGNI/EST
1
-
-
... More
Supply and fix in replacement of beam detector with with below specifications: Protection Rating IP20
Power Voltage 24 VDC
Standby Current 12 mA
Alarm Current 22 mA
Dimensions 206mmX95mmX95mm
Relative Humidity 95%. Make: Honeywell/Gulf Security Technologies/AGNI/EST
6
-
-
... More
Material and labour for software Logic deveplopment for Fire alarm control panel which includes the developmentof logic for false alarm which comes from Addressable fire alarm control panel and addressing of all the detectors, sounders, MCPs room wise for troubleshooting in alarm condition. Make: Honeywell/Gulf Security Technologies/AGNI/EST
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%