Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date15 Feb 2024
Closing Date5 Mar 2024
Tender Amount₹ 16,30,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No. 1 here-in-before but 125 KVA DG set

8

-

-

... More
All as per item No. 1 here-in-before but 100 KVA DG set

8

-

-

... More
All as per item No. 1 here-in-before but 62.5/63/75 KVA DG Set

28

-

-

... More
All as per item No. 1 here-in-before but 15/20 KVA DG Set

8

-

-

... More
Supply only set of fuel pre-filters and fine filters as per sample and make of the following capacities of DG sets (fixing under srl item No 1) Note: Each set comprising of the complete pre/fine filters required at site (i) 200 KVA DG set

2

-

-

... More
All as per item No. 7 here-in-before but 160 KVA DG set

2

-

-

... More
All as per item No. 7 here-in-before but 125 KVA DG set

4

-

-

... More
All as per item No. 7 here-in-before but 100 KVA DG set

4

-

-

... More
All as per item No. 7 here-in-before but 62.5/63/75 KVA DG Set

14

-

-

... More
All as per item No. 7 here-in-before but 15/20 KVA DG Set

4

-

-

... More
Supply only set of lub/engine oil filters/cartridges as per sample and make, of the following capacities of DG sets (fixing under srl item No 1) (i) 200 KVA DG set

2

-

-

... More
All as per item No. 13 here-in-before but 160 KVA DG set

2

-

-

... More
All as per item No. 13 here-in-before but 125 KVA DG set

4

-

-

... More
All as per item No. 13 here-in-before but 100 KVA DG set

4

-

-

... More
All as per item No. 13 here-in-before but 62.5/63/75 KVA DG Set

14

-

-

... More
All as per item No. 13 here-in-before but 15/20 KVA DG Set

4

-

-

... More
Supply only flexible fuel pipes with bunjo bolts and nuts as per sample length and size to meet the requirement of site condition complete all as specified.

10

-

-

... More
Supply only fan belts for replacement of u/s fan belts of following capacities of DG set as per sample size all as directed. Note: Fixing charges considered under srl item No 1 here-in-before (i) 200 KVA DG set

1

-

-

... More
All as per item No. 20 here-in-before but 160 KVA DG set

1

-

-

... More
All as per item No. 20 here-in-before but 125 KVA DG set

2

-

-

... More
All as per item No. 20 here-in-before but 100 KVA DG set

2

-

-

... More
All as per item No. 20 here-in-before but 62.5/63/75 KVA DG Set

7

-

-

... More
All as per item No. 20 here-in-before but 15/20 KVA DG Set

2

-

-

... More
Supply only main contactor for AMF panel model LCIF 185 Amps, Ith-275 Amps of 125 KVA DG set complete all as specified and directed

3

-

-

... More
Supply only contactor(neutral control) for AMF panel, model MN 32 of 125 KVA DG set complete all as specified and directed

1

-

-

... More
Supply only main contactor for AMF panel model CA 3-72M40 of 30 KVA DG set complete all as specified and directed

2

-

-

... More
Supply only ''ON DELAY TIMERS" (for stop/start/LOP/LOT/FAULT etc) Time range 3 sec to 30 hours, contact 5 Amps, 240V/12-24 volts, DC, complete all as specified and directed

3

-

-

... More
Supply only Auxillary/control contactors (2 NO, 2 NC) of suitable ratings for AMF panels complete all as specified and directed

5

-

-

... More
Supply only battery charger float cum boost charger ie step down transformer) for ratings 15A, 220-240V/12-14-16 Volts and suitable for AMF panels complete all as specified and directed

2

-

-

... More
Supply only battery charger float cum boost charger( step down transformer) fo ratings 10A , 415 Volts 0-24 Volts suitable for AMF panels complete all as specified and directed

2

-

-

... More
Supply only single phase preventor model VSP3, 415 volts AC 50 hz suitable for AMF panel complete all as specified and directed

2

-

-

... More
Supply only lead acid battery 12 V 180 AH, complete all as specified and directed.

1

-

-

... More
Supply only lead acid battery 12 V 150 AH, complete all as specified and directed,

1

-

-

... More
Supply only lead acid battery 12 V 135 AH, complete all as specified and directed,

1

-

-

... More
Supply only lead acid battery 12 V 70 AH, complete all as specified and directed.

1

-

-

... More
Supply only oil sensor upto 200KVA Dg set complete all as specified and directed.

2

-

-

... More
M&L for repair door of DG set canpoy using new hinges ,welding work ..etc upto 200KVA DG set complete.

2

-

-

... More
M& L for repair of fuel feed pump upto 200KVA DG set ,replacement of components required to make functional complete

2

-

-

... More
Material and labour for radiator anticorrosive coolent conditioner properly mixed up with the radiator water complete all as specified and directed.

100

-

-

... More
Material and labour for lubricant oil for diesel generating set of any capacity and any make complete all as specified and directed by Accepting officer

200

-

-

... More
Supply and fixing solenoid switch 12V as per sample of following capacities of D G sets: (i) 200 KVA DG set -01 Nos

1

-

-

... More
All as per item No. 43 here-in-before but 160 KVA DG set

1

-

-

... More
All as per item No. 43 here-in-before but 125 KVA DG set

1

-

-

... More
All as per item No. 43 here-in-before but 100 KVA DG set

1

-

-

... More
All as per item No. 43 here-in-before but 62.5/63/75 KVA DG Set

2

-

-

... More
All as per item No. 43 here-in-before but 15/20 KVA DG Set

1

-

-

... More
Supply and replacement of AVR for 62/62.5/75 KVA DG set as per sample including control wiring all as directed by Engr -in-Charge.

4

-

-

... More
Supply and replacement of AVR for 100 to 160 KVA DG set as per sample including control wiring all as directed by Engr -in-Charge.

2

-

-

... More
Supply and replacement of AVR for 200 KVA DG set as per sample including control wiring all as directed by Engr -in-Charge.

1

-

-

... More
M &L for replacement of unservicable self starter motor sutable for 62/62.5/75KVA DG set of suitable DC volatge 12/24V including control wiring from control panel and battery all as specfied and directed.

4

-

-

... More
M &L for replacement of unservicable self starter motor sutable for 100 to 160 KVA DG set of suitable DC volatge 12/24V including control wiring from control panel and battery all as specfied and directed.

1

-

-

... More
M &L for replacement of unservicable self starter motor sutable for 200KVA DG set of suitable DC volatge 12/24V including control wiring from control panel and battery all as specfied and directed.

1

-

-

... More
Supply and replacement PVC insulated battery lead of suitsble size with copper conductor cable of length 1.5 mtr with copper/brass clamps and lugs for fixing on battery terminals and self starter complete as specified and as directed.

10

-

-

... More
Replacement of unservicable microprocesser based control logic board matching and other related parts to existing control panel of 75KVA volatge stablizer for smooth working of stablizer all as specfied and dirceted by Engineer-in-charge

1

-

-

... More
Supply and fix AMF Panel for 15KVA DG set microprocessor based outdoor type double door type ,all sensor required to display and control to be installed in panel,front and back openable shall be designed for Automatic ON mains failure operation of the generator sets made with hinged doors, fabricated from 3.15 mm CRCA sheet metal and panel shall complete with interconnections, insulators, two number of earthling lugs and with suitable rating of MCCB 4P at two incoming and one outgoing ends and shall incorporate the followings - (i) Electric contactors for both DG and main supply (ii) Main Supply voltage monitor (iii) AMF logic unit having protection for over frequency, under frequency, over voltage, under voltage, low lube oil, and high water temperature for engine (iv) Main supply voltage monitor (v) Combined meter (MFM) for voltage, current, frequency, KVA, KWH and PF (vi) Battery charger float cum boost consisting of Transformer, Rectifier, DC Voltmeter, DC Ammeter, Charging rate selector switch (vii) Auto / Manual mode switch (viii) MCB using for indicators and meters (ix) Hooter 24 V DC

1

-

-

... More
(x) indicators for main supply and DG supply (xi) Cable conncetion and control wiring from Dg set to AMF panel shall be demmed to be included in quoted rate. Note: (i) Drawing of panel shall be submitted by contractor to get the approval from accepting officer.(ii) Civil work including foundation & earth work , shall be deemed to included in quoted rate.

-

-

-

... More
Supply and fix AMF Panel for 20KVA DG set microprocessor based outdoor type double door type ,all sensor required to display and control to be installed in panel,front and back openable shall be designed for Automatic ON mains failure operation of the generator sets made with hinged doors, fabricated from 3.15 mm CRCA sheet metal and panel shall complete with interconnections, insulators, two number of earthling lugs and with suitable rating of MCCB 4P at two incoming and one outgoing ends and shall incorporate the followings - (i) Electric contactors for both DG and main supply (ii) Main Supply voltage monitor (iii) AMF logic unit having protection for over frequency, under frequency, over voltage, under voltage, low lube oil, and high water temperature for engine (iv) Main supply voltage monitor (v) Combined meter (MFM) for voltage, current, frequency, KVA, KWH and PF (vi) Battery charger float cum boost consisting of Transformer, Rectifier, DC Voltmeter, DC Ammeter, Charging rate selector switch (vii) Auto / Manual mode switch (viii) MCB using for indicators and meters (ix) Hooter 24 V DC

1

-

-

... More
(x) indicators for main supply and DG supply (xi) Cable conncetion and control wiring from Dg set to AMF panel shall be demmed to be included in quoted rate. Note: (i) Drawing of panel shall be submitted by contractor to get the approval from accepting officer.(ii) Civil work including foundation & earth work , shall be deemed to included in quoted rate.

-

-

-

... More
Supply and fix AMF Panel for 62/62.5KVA DG set microprocessor based outdoor type double door type ,all sensor required to display and control to be installed in panel,front and back openable shall be designed for Automatic ON mains failure operation of the generator sets made with hinged doors, fabricated from 3.15 mm CRCA sheet metal and panel shall complete with interconnections, insulators, two number of earthling lugs and with suitable rating of MCCB 4P at two incoming and one outgoing ends and shall incorporate the followings - (i) Electric contactors for both DG and main supply (ii) Main Supply voltage monitor (iii) AMF logic unit having protection for over frequency, under frequency, over voltage, under voltage, low lube oil, and high water temperature for engine (iv) Main supply voltage monitor (v) Combined meter (MFM) for voltage, current, frequency, KVA, KWH and PF (vi) Battery charger float cum boost consisting of Transformer, Rectifier, DC Voltmeter, DC Ammeter, Charging rate selector switch (vii) Auto / Manual mode switch (viii) MCB using for indicators and meters (ix) Hooter 24 V DC

1

-

-

... More
(x) indicators for main supply and DG supply (xi) Cable conncetion and control wiring from Dg set to AMF panel shall be demmed to be included in quoted rate. Note: (i) Drawing of panel shall be submitted by contractor to get the approval from accepting officer.(ii) Civil work including foundation & earth work , shall be deemed to included in quoted rate.

-

-

-

... More
Supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 15KVA DG set including testing all as specfied and directed

1

-

-

... More
Supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 20KVA DG set including testing all as specfied and directed

1

-

-

... More
Supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 62.5KVA DG set including testing all as specfied and directed

2

-

-

... More
Supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 75KVA DG set including testing all as specfied and directed

1

-

-

... More
Supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 100KVA DG set including testing all as specfied and directed

2

-

-

... More
Supply and fix suitable 4 pole contactor with NO NC auxillary contact suitable for 200KVA DG set including testing all as specfied and directed

1

-

-

... More
Supply and fix suitable 4 pole MCCB 63A ,415V ,18KA Adjustable overload settings: 0.8 - 1.0 x In l Adjustable short-circuit settings: 6 - 10 x In Iincluding make tight nut bolt connection, testing all as specfied and directed

1

-

-

... More
Supply and fix suitable 4 pole MCCB 200A,415V ,25KA ,Adjustable overload settings: 0.8 - 1.0 x In l Adjustable short-circuit settings: 6 - 10 x In I including make tight nut bolt connection, testing all as specfied and directed

1

-

-

... More
Opening the top and bottom cover of the cylinderical type FRP Dual media filter and taking out the complete filter media from the vesel. Cleaning the complete internal surface area of the plant with wire brush,removing all the deposited sludge,mud dirt etc and cleaning the vessel with water. Washing complete sand filter media, screening with suitable size mesh stainer removing all the vegetation and making free from unwanted material. The scope of work includes the following :- (a) Supply and filling coarse gravel,fine gravel, fine sand , New/Fresh dual media as per existing (as required to fill) (b) Painting complete external surface of filter media, valves and connecting lines after completion of work. (c) Fixing of top and botton cover testing and commissioning complete.

1

-

-

... More
Opening the top and bottom cover of the cylinderical type FRP activated carbon filter and taking out the complete filter media from the vesel carefully . Cleaning the complete internal surface area of the filter with wire brush,removing all the deposited sludge,mud dirt etc and cleaning the vessel with water. Washing complete sand filter media, screening with suitable size mesh stainer removing all the vegetation and making free from unwanted material. The scope of work includes the following :- (a) Supply and filling coarse gravel,fine gravel, fine sand , New/Fresh activated carbon as per existing (as required to fill) (b) Reconncet the filter inlet/outlet pipe and cleaning of connceted pipes to filter and remove the blockage in control vlaves, bypass valve all as directed by Enginner-in-Charge. (c) Fixing of top cover testing and commissioning complete.

1

-

-

... More
Cleaning of various tank like inlet chamber , bar screen chamber, grit chamber ,equilization tank,MB reactor-1,MB Reactor-2 ,Lamller flow chamber ,Filter Feed tank,Treated water tank of RCC made, removing blockage of stariner inlet, pump outlet, all pipe of various size installed in STP of 0.15 MLD capcity sewage treatment plant by dewatering the existing soil, slit, sludge by using pneumatic pump adhering proper precautions and safety measures,cleaning the entire surface of bottom and side walls by washing with a pressure nozzle to remove entire dirt etc all as specified and directed by Engineer-in-Charge Note:Contractor will laise with Gujart state pollution control board to submit the report about plant functionality/servicablity.The cleaning of plant shall be carried out as per the directory of Gujarat pollution control board.if the contractor fail to operate this item ,the recovery of Rs 20000 shall be lavied by the department.

1

-

-

... More
Supply & Fill microbes (K Bio pack media)

1

-

-

... More
Supply only Alum Non ferric(crystal) Note:Test certificate shall be produced along with the material.

200

-

-

... More
Supply only Bleaching powder Grade -I ISI Mark,Make:Shri Ram Note:Test certificate shall be produced along with the material.

1000

-

-

... More
Supply only caustic soda (NaoH) complete Note:Test certificate shall be produced along with the material.

300

-

-

... More
Disconnecting complete gear box assembly from low speed fixed type AERATOR and taking out carefully from aeration chamber,strip opening and dismantling complete gear box assembly for replacement of following worn out unserviceable parts complete all as specified and directed:- (a) Roller sealed bearing of suitable size (b) Gear box oil-07 ltrs(Hp hear oil XP-90) (e) Oil seal-01 No. (f) Carbon steel star pinion gear,80 mm dia. 25 Teeth cat part No. 6002149PB-01 No, (g) Pressure plate duly drilled to suit for fixing with gear box -01 No. ()h) Painting complete gear box, platform hand rail and connected items as specified and directed.

1

-

-

... More
Supply and fix suction strainer steel of size 100mm dia including conncetion to exsiting PVC of size 100mm dia and material like flange , rubber packaging to be included in quoted rated

1

-

-

... More
Disconnecting and taking down from inlet chamber and dismentling pump sets, non cloging type of capacity 3 HP installed on sewage collection sump near STP for overhauling, painting (after complettion of work) and repair /replacement of the following worn out parts (a) CI Impeller of Existing size (b) Carbon steel shaft duly threaded from boath ends as existing -01 (c ) Carbon steel keys for pump shaft -02 (d) Ball bearing of suitable size (f) Gasket as Existing -01 (g) Assembling ,coupling with electric motor and testing complete

1

-

-

... More
Disconnectin and taking down and dismentling pump sets,horizontal non cloging type pump of capacity 3 HP installed on Equilization tank to MR reactor-1 of sullage water for servicing /over hauling and repair /replacement of the following worn out parts:- (a) CI Impeller of Existing size (b) Carbon steel shaft as existing-01 (c) Carbon steel keys for pump shaft -02 (d) Ball bearing suitable size (f) Gasket as Existing -01 (g) Assembling ,coupling with electric motor and testing complete.

1

-

-

... More
Disconnectin and taking down and dismentling pump sets,horizontal non cloging type of capacity1.5 HP installed on common base plate for feeding of raw water to filter of sullage water for servicing /over hauling and repair /replacement of the following worn out parts:- (a) CI Impeller of Existing size (b) Carbon steel shaft as existing-01 (c) Carbon steel keys for pump shaft -02 (d) Bush and ball bearingof existing size -01 (e) Gasket as Existing -01 (f) Assembling ,coupling with electric motor and testing complete and complete painting all as specified and directed.

1

-

-

... More
Disconnecting electric supply from the motor, removing coupling and kepping in safe custody and removing motor of capacity 5 HP and taking out pump motor of capacity 5HP, 3 Ph, 415 /volt, 50 Hz from STP shift to workshop and to carryout repair, dismantle the motor cutting/removing the burn out winding, cleaning the slots and rewoinding the motor with super enameled copper winding wire of same gauge/turns, heat varnishing, replacing the bearing (02 Nos) shaft assembly and shaft sleeves, reassemble the motor and fixing it in its original position, reconnecting all the removed lines and testing all complete. (Painting of motor after completion of work).

1

-

-

... More
Disconnecting electric supply from the motor, removing coupling and kepping in safe custody and removing motor of capacity 1.5 HP and taking out pump motor of capacity1.5HP, 1.5 Ph, 415 /volt, 50 Hz from STP shift to workshop and to carryout repair, dismantle the motor cutting/removing the burn out winding, cleaning the slots and rewinding the motor with super enameled copper winding wire of same gauge/turns, heat varnishing, replacing the bearing (02 Nos) shaft assembly and shaft sleeves, reassemble the motor and fixing it in its original position, reconnecting all the removed lines and testing all complete. (Painting of motor after completion of work).

1

-

-

... More
Disconnecting electric supply from the motor, removing coupling and keeping in safe custody and removing motor of capacity 3 HP and taking out pump motor of capacity 3HP, 1.5 Ph, 415 /volt, 50 Hz from STP shift to workshop and to carryout repair, dismantle the motor cutting/removing the burn out winding, cleaning the slots and rewinding the motor with super enameled copper winding wire of same gauge/turns, heat varnishing, replacing the bearing (02 Nos) shaft assembly and shaft sleeves, reassemble the motor and fixing it in its original position, reconnecting all the removed lines and testing all complete. (Painting of motor after completion of work).

1

-

-

... More
Supply and install CI butterfly valve of size 100mm dia including replacement of rubber packing ,nut bolts all as specfied and directed.

4

-

-

... More
Supply and install CI butterfly valve of size 50mm dia including replacement of rubber packing ,nut bolts all as specfied and directed .

2

-

-

... More
Supply and fix MXN9 AC 3 , 3 pole contactor with add on block including control wiring all as specfied and directed

5

-

-

... More
Testing of treated water of STP from NABL recoginised lab as existing indian standards/Gujarat pollution control board to be carried out and submitted report monthly to Enginner-in-charge. Note:Penality of Rs 5000 per month shall be recovered if report not submitted monthly.

11

-

-

... More
Replacement of unservicable indication lamps ,selector switch matching to existing size all as specfid and directed

5

-

-

... More
The following protection to be provided to pumpset/Blower (Raw water pumpsets, submersibale pumpsets, feed water pump sets and blower) installed at 150KLD STP plant. (i) Under voltage and over voltage protection. (ii) Under load and over load protection with suitable rating of CTs. (iii) Surge protection. (iv) short circuit protection. Enclosure /panel be IP 66 ,kisok type ,CRCA sheet of 3.15mm thick,copper bus bar & terminals, multi functional meter,digital voltmeter and ammeter,indicators, including control wiring and connection from enclosure to existing panel and other connected items complete.

1

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600mm X 600mm X 6mm buried directly in ground vertically to a depth not less than 2.25 metre below normal ground level (with top edge of earth plate not less than 1.5 metre below ground level) connected tog galvanised iron strip 32×6mm as earthing lead , (main earthing lead) by means of galvanized bolts, nuts and washers all as shown in electrical plate No 3 of MES Schedule Part-I (2009) with connected to earth test point & to main switch board with & including adequate quantity of charcoal dust and common salt alround earth plate & 15 mm dia GI pipe medium grade for earth lead protection pipe for suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mesh including necessary earth work and PCC (1: 3 : 6) type C-1 for earth pit and 40 mm thick precast RCC cover in 1 : 2 : 4 type B-1 with 3 Nos 8 mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified & directed. NOTE: Earth strip and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item and additional earth GI earth wire/protection pipe etc. if any required at site shall be measured and paid for separately under appropriate item of Schedule `A’ NOTE - The unit rate shall also include for earth work in any type of soil, PCC (1:3:6) type C1 chamber, RCC 1:2:4 type B1 cover 50mm thick reinforced, funnel with watering pipe.

10

-

-

... More
Supply and fix Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 32 mm x 6mm aluminium strip all as specified and directed.

300

-

-

... More
M&L stainless steel ,trolly mounted, suction sweeper 2HP pumpset,hose pipe 50 mtr , Head as per manufacture recommendation, trolly, telescopic rod, curved brushes ,1-phase, deep leaf net,swivel cuff for kink free maneuverablity,UV ,chemical resisitance,starter with undervoltage,over voltage,under load, over load,short circuit protection and surge protection , suitable capacity cable from pump to starter, nylon rope,potable trolly with carries motor pump ,starter and wire,pump has all fittings for conncetion ,heavyduty wheel, extra 2 nos brushes all as specified and directed .

2

-

-

... More
Supply only algaecide cleaner for swimming pool, safe for skin and eyes of swimmers,excellent to kill all types of algae, procedure to use to be provided complete.

100

-

-

... More
Supply & fixing in repair dosing Pump high pressure single head gear motorized adjustable dosing pump with accessories suitable for olympic size swimming pool including suitable capacity of moto, electric connection,including starting arrangment, single phase comprising with over voltage ,under voltage protection , replacement of lead tubing, connecting nuts, injection check valve, clay weight, ferules etc. all as specified and directed.

1

-

-

... More
Supply and Fixing in repair agitator for olympic size swimming pool with suitable length of connceting rod for exsiting tank, capable to make homogenious mixture ,mounting arrangment include lid & other accessories required to fix, suitable capacity of motor, shaft & blade, electric connection,DOL starter ,single phase comprising with over voltage ,under voltage protection complete all as specified and directed.

1

-

-

... More
Supply and Fix Pressure Gauge for Pressure Range 0-7 Kg/sqcm Make Aquaslux Water Stainless Steel Glycerine Liquid filled of size 2.5" Dia back connection 1/4'' male complete

5

-

-

... More
M&L swimming pool floor diffuser size and shape as per existing ,heavy duty,white colour complete

100

-

-

... More
M&L swimming pool net, foldable ,66 inch telescopic landing net with aluminium alloy handle, robust and durable complete

6

-

-

... More
Supply and fixing cast iron foot valve flanged end of size 200 mm dia with all fitting and accessories .

2

-

-

... More
Supply and fix CI flanged strainer Y-type of size 200mm with all fitting and accessories to fix complete

2

-

-

... More
Supply and fix CI flanged NRV of size 200mm with all fitting and accessories to fix, with bypass arrangment complete

2

-

-

... More
Note:-(1) The contractor shall keep all items readily available at site, which is required for urgent repair works.

-

-

-

... More
(2) Common miscellaneous material such as screws any type, nails,nuts & bolts, washers, insulation tapes, clamps, hooks, which are required for the work the cost of which is deemed to be included in quoted rate.

-

-

-

... More
(3) Contractor’s supervisor should be available at the site to supervise the works and co-ordinate with the officials.

-

-

-

... More
(4) The manpower shall be issued identity card after getting due verification. Uniform should be worn by the manpower having monogram of the firm.

-

-

-

... More
(5) The skilled worker should be facilited with mobile phone to contact on urgent tasks & their numbers should be displayed at swimming pool and forwarded to administration.

-

-

-

... More
(6) The contractor shall ensure safety of his workers and other at site of work and shall be responsible for any consequence arising out of execution of the repair and maintenance works.

-

-

-

... More
(7) The contractor shall ensure that his repair/ maintenance staff is qualified and licensed for their part of work. He shall be responsible for their conduct. The contractor shall be held responsible for any loss or damage to employees’ state insurance corporates property.

-

-

-

... More
(8) All repair and maintenance related complaints shall be attended within two hours failing, which a recovery of Rs 500/- per event per hour shall be made from the subsequence payment of the contractor.

-

-

-

... More
(9) The contractor provide test certificate of material to be incorporated in the work.

-

-

-

... More
(10) Any persons of contractor causes damage of equipment or property of Military station, the contactor will be solely held responsible for the cost of consequences thereof.

-

-

-

... More
(11) In the event of the contract work getting delayed due to reasons attributable to the contractor, the department shall be levying the penalty at the rate of 5% per week to the maximum of 10% of the contract value.

-

-

-

... More
(12) Contractor shall carry out all test. The equipments shall conform to Indian standards.

-

-

-

... More
(13) Work diary & hindrance register shall be maintained by the contractor. The both shall be deposited to department daily.

-

-

-

... More
(14) Joint measurement shall be done weekly. The contractor should be available for joint measurement along with supervisior on every Wednesday from 15.00 hr to 17.00hr. If contractor fails to be present at site , the progress of that week shall be fwd to division 'Nil'

-

-

-

... More
(15) Contractor shall provide all stationery such as docket book,complaint register,work diary,hindrance register etc.

-

-

-

... More
NOTE APPLICABLE FOR ALL ITEMS :- If rate quoted for similar/identical items in same part of Sch ‘A’ is at variance, the lowest rate quoted shall only be considered for payment to the contractor.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.