Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643144_1Tender No
8726/V/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply and fixing LED street light fitting 60 watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge.
Note: Contractor will arrange T&P and veh required for repairing lights and the cost for the same will incl in the quoted rate
40
-
-
Supply & fix 120 watt new generation, energy saving environment friendly & robust highbay LED with PDC housing suitable for ceiling(surface/suspended) mounting with system efficacy upto 150 watt complete all as specified and directed by Engineer-in-Charge.
Note: Contractor will arrange T&P and veh required for repairing lights and the cost for the same will incl in the quoted rate
29
-
-
Material & labour for finding out LT fault in feeder of affected area with deploying trained electrician and helper seggregate/ isolate the feeder carry out maintenance work such as repair of jumper,insulators ,connected items and then after charge the feeder with load in presence complete all as specified and directed by Engineer-in-Charge.
70
-
-
Supply & fix in replacement of sail LED twin type avaiation obstruction light fitting complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply & fix in replacement of SAIL LED single type avaiation obstruction light fitting complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply & fix in replacement of 3 pole power contactor ML 4, 70A, 415V complete all as specified and directed by Engineer-in-Charge.
5
-
-
Supply & fix in replacement 3 pole power contactor ML-1.5,25 A,415 V for high mast light complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supply & fix in replacement of street light digital timer complete all as specified and directed by Engineer-in-Charge.
15
-
-
Supply & fix in replacement MCB SP 6 to 40 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
45
-
-
Supply & fix in replacement MCB TPN 63 Amps 10 KA complete all as specified and directed by Engineer-in-Charge.
25
-
-
Material & labour for servicing/taking out of the high mast three pase electic motor for rewinding and rewinding with existing gauge of copper wire complete and refixing the same motor & testing for smooth working in presence complete all as specified and directed by Engineer-in-Charge.
2
-
-
Dismantling & refixing of existing 18 mtr high mast light pole with ring complete assembly , aviation light, feeder panel incl MCCB, timers, contractors complete all as specified and directed by Engineer-in-Charge.
Note:-(i) Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 1.5 metre depth with all materials and labour. Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs and all labour. Necessary foundation including excavation work deemed to inculded in Quoted rate.(01 Each)
(ii) 06 Nos MH flood lights will be repaced with 300 Watt LED flood lights and the same will be measured under appropriate item
(iii) Contractor will arrange T&P and veh required for repairing lights and the cost for the same will be incl in the quoted rate .
1
-
-
Supply laying, jointing and testing cable XLPE insulated, armoured heavy duty electric cable with stranded aluminium conductor, 1100 volts grade, laid in trenches passing through pipe/ ducts/ surface of wall ceiling etc of size 16 sqmm, 4.0 core complete all as specified and directed by Engineer-in-Charge.
160
-
-
Excavation in trenches, in any type of soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in depth , laying of cable or pipes (where provided for protection of cable) etc and getting out trimming the sides, forming bottom surfaces to required level complete all as specified and directed by Engineer-in-Charge.
34.56
-
-
Material & labour for sand cushioning with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed by Engineer-in-Charge.
10.36
-
-
Supplying and laying un-reinforced precast concrete cable cover class LV, type - 2, flat, size 300x 180 x 40 mm complete all as specified and directed by Engineer-in-Charge.
711
-
-
Returning and filling including spreading, levelling, watering and well ramming in layers not exceeding 25 Cm thick complete all as specified and directed by Engineer-in-Charge.
22.66
-
-
Removing of surplus soil to a distance not exceeding 50 Mtrs and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
11.9
-
-
Supply & fix in replacement of 1100 volts grade heavy duty cable with PVC insulated alluminium conductor served with an inner sheathing of PVC tape and overall PVC sheathed 5 core 2.5 Sqmm trailing cable for connection of high mast lights complete all as specified and directed by Engineer-in-Charge.
60
-
-
Supply & fix in replacement of emergency bells 215 Volt 50 Hz as per sample at various locations complete all as specified and directed by Engineer-in-Charge.
3
-
-
Material & labour for zebra painting white & sparkle sky blue strips 30 cm height in alternate colour strip upto 1.5 meter from top edge of coping of electric poles with synthetic enameled paint two coats and numbering to poles with 80mm size letter with black synthetic enameled paint complete all as specified and directed by Engineer-in-Charge.
30
-
-
Supply & laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 3 core nominal cross section solid conductor in service connections complete all as specified and directed by Engineer-in-Charge.
200
-
-
Supply & laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 4 core nominal cross section solid conductor in service connections complete all as specified and directed by Engineer-in-Charge.
200
-
-
Material & labour for wiring circuit along with earth wire from Sintex box to Street light fitting with 3 run of 1.5 sqmm sizes FRLSH insulated copper conductor single core cable in suraces/recessed as required including Steel conduit of size 20 mm dia with suitable clamps made out of 25X3 mm thick steel flat complete with nuts bolts and washers complete all as specified and directed by Engineer-in-Charge.
110
-
-
Supply & fix in replacement FRP juction box of size outside dimensions 400 x 300 x 190 mm with 4 nos copper busbar of capacity 100 Amps , length 250 mm , 01 Nos MCB SPN C series of capacity 06 Amps as approved by the EIC including connector and fixing on pole with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc. complete all as specified and directed by Engineer-in-Charge
Note:- The cost of sintex box installation includes making hole of suitable size for entry and exist of cable any size, making new lugs of cables of entry and exit incl cable glands.
26
-
-
Supply & fix in replacement of LED post top of 25 watt integral pole mounted decorative LED with IP-65 protection complete fixed on existing post complete all as specified and directed by Engineer-in-Charge.
18
-
-
Supply & fix in replacement of MCCB's,415 Volts, 3 pole with fix / adjustable type having 25 to 100 Amps with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
14
-
-
Supply & fix in replacement of flame proof switch nob made of ceramic / plastic, fixing with proper screw, greasing and replacement of connector complete all as specified and directed by Engineer-in-Charge.
49
-
-
Supply & fix in replacement of automatic / manual with inbuilt time delay transfer switch 100 Amps four pole (with enclosure) with connections of auto / manual transfer switch including testing complete all as specified and directed by Engineer-in-Charge.
1
-
-
Supply & fix bracket for street light fitting made out of GI tubing 40 mm med grade pipe1.50 mtr (2' x 1 -1/2'), 135 degree bend with cutting ,welding and two MS bracket with nut bolts and washer bracing to pole/on fencing for street light fittings complete all as specified and directed by Engineer-in-Charge.
28
-
-
Material & labour for complete cleaning of the internal & external parts of LT panel; checking & testing of all the components of the panel for cable insulation, lugs, connections and the like; replacement of & including provision of minor parts like lugs, insulation tape, nuts bolts, connectors and the like as directed by Engineer-in-Charge; replacement and / or welding of existing damaged hinges of the panel; preparation of old painted surfaces (internal & external) of the panel, complete removal of existing paint using emry paper grade 220, by sanding and scrubbing, application of corrosion resistant primer by sprayers, applying hammer finish metal paint using sprayers in two coats and till shining surfaces are obtained; application of two coats of epoxy black paint on panel frames; complete all as specified and directed by Engineer-in-Charge.(Approximate average size of panel=1.50x0.75x0.45m) (Note - Rates included for provision of sufficient technicians for getting electric shut down and to attend the shutdown on site till completion. Replacement of major items like MCCBs etc. shall be measured & Paid for separately). .
17
-
-
Cutting and trimming the tree branches touching/obstructing the over head lines/poles/fittings etc at least upto with in the area of 1 mtr both side of LT over head line, bottom of poles, stay assy of span 35 to 45 mtr and removing the same from the site complete all as specified and directed by Engineer-in-Charge.
56
-
-
Material & labour for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing for cable size 25 to 50 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
8
-
-
Material & labour for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing for cable size upto 6-16 Sqmm, 4 core complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supply & fix heat shrinkable PVC insulation sleeves of suitable size for cables upto 50 sqmm 1100 Volts in colour red,yellow, blue and black of 1m length complete all as specified and directed by Engineer-in-Charge.
120
-
-