Military Engineer Services Tender

... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date28 Jan 2025
Closing Soon24 Feb 2025
Tender Amount₹ 48,58,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.

0.5

-

-

... More
Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.

8.45

-

-

... More
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and stacking at site where directed and removal of debris as ordered outside MoD land complete all as specified & as directed.

635

-

-

... More
Dismantling wall and ceiling board (fibre, pulp, insulation etc.) or insulation boards/ slabs/ blankets, any thickness including cover fillets complete all as specified and as directed.

40

-

-

... More
Taking down chowkat or frame with shutters (including grills, fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.

2

-

-

... More
Taking down aluminium door shutter of any description exc 1.2 Sqm but not exc 2.5 Sqm each and refixing in the same opening after necessary repair including changing all aluminium cleats/ screws and resecuring the door complete to the satisfaction of Engineer-in-Charge.

2

-

-

... More
M&L for cutting holes into or through brick / PCC block / stone masonry wall built in cement mortar and making good in cement mortar 1:3 or PCC 1:2:4 type B0 as required for superficial area exc 150 sqcm but not exc 400 sqcm and 15 to 20 cm of depth (of cutting), complete all as specified and as directed.

40

-

-

... More
M&L for cement concrete 1:2:4 type B0, using 12.5mm graded crushed stone aggregate as in roof kerbs, mud stops, coved fillets, cills, steps, copings, kneelers, apex stones, bed plates and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.

0.05

-

-

... More
M&L for cement concrete 1:2:4 type B1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs, mud stops, coved fillets, padding over roof and the like including weathering, slightly rounded, chamfered angle and throating as directed including use and waste of form work (straight or curved) all exposed surface of concrete finished fair complete all as specified & as directed.

1.1

-

-

... More
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed.

0.45

-

-

... More
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed.

40

-

-

... More
Supply only Integral Water Proofing Compound (ISI Marked).

101

-

-

... More
S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.

0.2

-

-

... More
S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.

8

-

-

... More
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames and shutters for doors, windows and ventilators with one or more rebates including joining cleat for fixing, anodised aluminium snap on beading, neoprene gasket, powder coated aluminium handles of suitable size, etc. complete all as specified and as directed.

150

-

-

... More
M&L for 12mm thick prelaminated particle board (ISI marked), interior grade, prelaminated both sides with decorative choice lamination, fixed with screws to timber//Steel/aluminium frame work complete all as specified & as directed.

10

-

-

... More
S&F 200 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.

8

-

-

... More
S&F 100 mm size stainless steel butt hinges (ISI Marked), medium weight.

22

-

-

... More
S&F 200mm size extruded aluminium alloy handles (ISI Marked), fabricated type, anodised and fixed.

16

-

-

... More
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.

4

-

-

... More
S&F 80mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door as directed. Note :- Door stopper shall be conforming to the sample kept in GE’s office.

8

-

-

... More
S&F cast iron body door closer, hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed complete all as specified & as directed.

8

-

-

... More
S&F in repairs XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.

8

-

-

... More
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed.

250

-

-

... More
S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 (Gde E-165) complete all as specified and as directed.

4

-

-

... More
S&F rolled mild steel work as in Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, with bolted or welded attachment, including necessary welding etc. conforming to Fe-410-W (Gde E-250) quality `A’ complete all as specified and as directed.

110

-

-

... More
S&F rolled mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, necessary welding, etc. conforming to Fe-410-W (Gde E-250) quality `A’, complete all as specified and as directed.

1750

-

-

... More
M&L for Hot dip galvanised (80 micron as per IS 475) mild steel welded wire fabric, weight not exceeding 4 Kg per sqm of size 3mm dia, 30x30mm spacing (or of size as directed by Engineer-in-Charge) fixed to wood or steel members complete all as specified and as directed.

205

-

-

... More
S&F GI Chicken wire mesh cut to size made to shape as ordered including fixed to walls with nails for receiving the plaster complete all as directed. Note : Weight of GI chicken wire mesh shall be 250 to 300 gm/Sqm.

220

-

-

... More
S&F 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including MS powder coated (white) snap Grid of size 605x605 mm frame work using 24mm x 32mm x 0.7mm main ‘Tee’ runner to be interlocked, 24mm x 32mm x 0.70mm cross ‘Tee’ and 24mm x 32mm x 0.70mm angles fixed to wall for ceiling including necessary supporting hanger with 4 mm dia GI wire (upto 3.5m long adjustable) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 24x7mm size 60mm long for securing frame work to ceiling suspended @ 1200mm centre to centre both way with PVC rawl plug with & including 6mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer’s instructions, with & including painting the ceiling board with two coats of oil emulsion distemper (OBD) of approved shade over a coat of primer on ceiling with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of false ceiling work including testing on completion as ordered complete all as specified & as directed.

40

-

-

... More
S&F 6mm thick plain acrylic sheet, fixed in roof covering/ walls, etc with coach screws and washers, complete all as specified & as directed.

8

-

-

... More
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ ridges/ cladding to walls, fixed with self tapping screws complete all as specified & as directed. Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc

590

-

-

... More
S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof coverings/ cladding to walls, ridges, gutters, valleys etc. fixed with self tapping screws complete all as specified & as directed. Notes : (i) Colour of sheet shall be as approved by the GE. (ii) Quoted rates shall deemed to be inclusive of scaffolding, safety net, safety belt, etc

45

-

-

... More
M&L for cutting out cracks to 'V' section in existing roofs or terrace cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & as directed.

30

-

-

... More
Material and labour for complete removal of existing water proofing treatment of any description or any other type of treatment over roof slab, parapets, chimney stacks, etc including cement plaster and cleaning the surface with wire brushes and washing with water, removing of insolvent materials and removing & depositing the debris, rubbish, etc outside MoD land, brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer's instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is cured with water for 7 days & completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 160 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed. Notes: (i) WPC shall be measured & paid for separately as ‘Supply only’. (ii) The work shall be carried out only through manufacturer or their authorised applicator and contractor shall submit a written guarantee of the manufacturer/authorised applicator for the effectiveness of WPT for 10 years from the date of completion of contract. (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps.

85

-

-

... More
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.

65

-

-

... More
M&L for 100 mm thick PCC 1:2:4, type B2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.

250

-

-

... More
M&L for 75mm thick PCC 1:3:6, type C2 (using 40 mm graded crushed stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc finished fair and even complete all as specified & as directed.

345

-

-

... More
M&L for factory made M-35 grade, 60 mm thick machine pressed, rubber moulded precast cement concrete interlocking paver blocks of shape and size as directed with grey cement and pigment confirming to IS: 15658-2006 (ISI marked), laid over and including 50 mm thick compacted sand cushion complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of 50 mm thick compacted sand cushioning. (ii) Shape of paver blocks shall be as approved by the GE.

345

-

-

... More
M&L for Rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surface of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.

40

-

-

... More
M&L for Rendering 20 mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.

337

-

-

... More
M&L for rendering 15 mm thick in CM 1:6 on fair faces of brick work or concrete surface of walls, finished even & smooth without using extra cement complete all as specified and as directed.

40

-

-

... More
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.

320

-

-

... More
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.

30

-

-

... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed.

120

-

-

... More
M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty complete all as specified & as directed.

30

-

-

... More
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.

220

-

-

... More
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of ceiling and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on ceiling complete all as specified & as directed.

40

-

-

... More
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.

1100

-

-

... More
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.

325

-

-

... More
M&L for writing letters or figures (Block, Roman, Italic or Indian) of size 8 to 10 cm high with thick synthetic enamel paint of approved tint over a synthetic enamel paint circle of 30 cm dia in approved tint for describing building numbers on concrete/plastered surfaces complete all as specified & as directed. Note : The font, style, matter, tint of paint & place of writing shall be as directed by the Engineer-in-Charge.

2

-

-

... More
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed.

15

-

-

... More
S&F 5mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections exceeding 0.5 Sqm in each pane complete all as specified & as directed.

3.5

-

-

... More
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.

22

-

-

... More
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.

120

-

-

... More
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying one coat of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.

850

-

-

... More
M&L for application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR latex per bag of cement {Compressive strength after 28 days ≥ 40 N/sqmm (According to ASTM C109)} in small patch work over column/ beams/ ceilings / walls surfaces 20 to 30mm thick in two layers over a coat of bonding agent like Nitobond SBR (1 ltr SBR + 3 Kg cement) applied as per manufacturer’s instructions for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Note :- SBR latex chemical shall be measured and paid for separately as ‘Supply only’.

250

-

-

... More
Supply only SBR latex chemical of Make Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian as approved by GE.

420

-

-

... More
Cutting/ Chipping/ Dismantling of spall / loose damaged concrete from soffits of RCC slab / other RCC structural members in a controlled manner carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete upto good parent concrete to expose the existing reinforcement (direct hammering should be avoided) average thickness of 40-70 mm including cleaning the exposed surfaces by water jet pressure pump at 4 to 5 kg/ Sqcm pressure to remove chlorides and loose particles, air drying the surface etc for further treatment with & including all necessary tools, safety measures like helmet, safety belt, adequate labour insurance, scaffolding, etc. for height upto 15 metre from average ground level under the supervision of qualified supervisor (the damaged ceiling/ concrete shall only be measured) complete all as specified and as directed.

520

-

-

... More
M&L for cleaning existing reinforcement bars with wire brush / rotary wire brush making the surface free from cement skin, loose particles, dirt, etc and applying rust remover/converter (Rebaklense RR of M/s Fosroc / Amandur of GK technocom or equivalent of Dr. Fixit / SIKA / Pidilite) over the corroded reinforcement bars where ever micro concreting is required and cleaning the same after application with & including all necessary tools, scaffolding, etc. for height upto 15 metre from average ground level complete all as specified and as directed.

520

-

-

... More
Supply and application of Nitozinc Primer of M/S Fosroc or equivalent of Dr. Fixit / SIKA / Pidilite over the exposed steel reinforcement after removing the rust scales from the exposed reinforcement bars with & including all necessary tools, scaffolding, etc. for height upto 15 metre from average ground level complete all as specified and as directed.

520

-

-

... More
M&L for applying Nitobond EP (2.5 Kg pack and coverage area 5.5 Sqm/ 4.5 Kg pack and coverage area 10 Sqm) epoxy bonding agent over the old concrete surfaces including the cost of all materials, rent of tools, scaffolding, brush etc. for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Make: Fosroc or equivalent of Krishna Conchem / Dr. Fixit / SIKA / Pidilite / BASF / Sunanda / Asian as approved by GE.

520

-

-

... More
M&L for providing additional reinforcement TMT bars in place of more than 1/3 corroded reinforcement bars including cutting, bending, placing and fixing in position using 'Lokfix' of M/S Fosroc or equivalent of Dr. Fixit / SIKA / Pidilite with & including all necessary tools, scaffolding, etc. for height upto 15 metre from average ground level complete all as specified and as directed. Note : Weight of TMT bars shall only be measured for payment purpose.

350

-

-

... More
M&L for non shrink cementitious micro concrete (‘SikaRep Microcrete-4’ of Sika / ‘Renderoc RG’ of Fosroc or equivalent of Dr. Fixit) meeting ASTM C1107 standard in average thickness 70mm and having minimum compressive strength 50 N/sqmm after 28 days as per ASTM C109, for repair to column, beam, slab, etc, complete all as per manufacturer’s instructions cost inclusive of scaffolding, shuttering, formwork, curing etc. for height upto 15 metre from average ground level complete all as directed. Notes : (i) Quoted rate shall deemed to be inclusive of form work, scaffolding, safety belt, etc. (ii) Reinforcement shall be measured and paid for separately.

520

-

-

... More
M&L for Teflon nozzles compatible with epoxy injector, drilling holes of 12mm dia, upto 100mm deep holes in structural members at the interval of 500mm c/c for slab, 300mm c/c for column and beam in staggered manner or along the crack as directed by the Engineer-in-Charge in RCC structural element including cleaning of the holes by air blower and inserting 8-10mm dia Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system minimum 8 hours before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface, after completion of the work, etc, inclusive of scaffolding etc for height upto 15 metre from average ground level complete all as directed.

250

-

-

... More
M&L for grouting of RCC structure with low viscous two parts of epoxy (mixed in ratio as specified by manufacturer) by using pressure pump and pressure grouting with compressor at about 1 kg to RCC beams/ chajjas/ slab/ columns as per manufacturer’s instructions and direction and cutting the Teflon nozzles after grouting and making surface good inclusive of scaffolding etc for height upto 15 metre from average ground level complete all as directed. . Make of low viscous epoxy shall be of Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian

60

-

-

... More
E&M Items: S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.

5

-

-

... More
Taking down existing flood light fitting of any description and S&F new 150 W LED flood light fitting, IP-66 rated with high pressure die cast aluminium housing, lens and toughened glass cover, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, CCT 5700K, with & including external Surge Protection Device (SPD) 10 kV, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system and testing on completion complete all as directed.

5

-

-

... More
Supply, installation & testing electric Geyser (electric water heater storage type) of capacity 25 litre, vertical mounting type, glass lined inner tank, PUF insulation, rust proof outer body, 2 KW heating element, suitable for 230V Single Phase 50 Hz AC supply, BEE 5 Star rating, Rated Pressure 0.8 Mpa, with & including manual knob adjustable Thermostat with thermal cut off, heating indicator, Multi-function Safety Valve, including pasting of DO’s & Don’ts instructions printed on self adhesive plastic coated paper on outer body, fixed all as per manufacturer’s instructions, fixed with & including ‘Anchor’ type /fastener type bolts & nuts (Set of 4 bolts of 10mm dia 150mm long with nuts & washers) into the wall grouted properly to hold the geyser and making good the disturbed surface in CM (1:3), complete all as specified & as directed.

12

-

-

... More
S&F 15mm dia stainless steel braided connection tube, heavy duty of size 450 mm long with CP brass adopter/ union washer both sides suitable for hot & cold water supply for geyser complete all as specified and as directed.

24

-

-

... More
S&F 15mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement on walls/ceilings (concealed/surface) or laying in floors complete all as specified and as directed.

15

-

-

... More
S&F 15mm bore bib tap with wall flange, fancy type, cast copper alloy, chromium plated screwed for iron pipe or for brass ferrule complete all as specified and as directed.

12

-

-

... More
S&F 15 mm bore stop valve, fancy type, cast copper alloy, chromium plated, screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.

12

-

-

... More
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one Single Pole MCB 20 Amps, 'C' Curve complete all as directed.

12

-

-

... More
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.

1

-

-

... More
S&F MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.

12

-

-

... More
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.

5

-

-

... More
S&F in repairs MCB SPN 40 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.

1

-

-

... More
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty non-metallic rigid PVC conduit (ISI marked) & conduit fittings/accessories, fixed on wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Note :- 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.

200

-

-

... More
M&L for sub main wiring with two runs of 4 sqmm (nominal area) size main cable & one run of 4 sqmm size earth continuity conductor cable, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade (ISI marked) cables, drawn through & including suitable size of heavy duty PVC casing and capping double lock type (ISI marked) with accessories, fixed on wall/ceiling complete all as specified & as directed. Note :- 02 runs of 4 sqmm size main cable, 01 run of 4 sqmm size earth continuity conductor cable and casing and capping/ conduit with accessories shall be measured as one run length for payment purpose.

77

-

-

... More
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.

70

-

-

... More
Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.

55

-

-

... More
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.

6

-

-

... More
M&L for cutting of existing road for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed.

5

-

-

... More
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.

1

-

-

... More
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.

15

-

-

... More
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.

13

-

-

... More
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.