Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 70,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_638024_1Bid Award Id
ViewTender No
9230/PBR/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR / REPLACEMENT AND MAINTENANCE OF STREET AND SOLARLIGHT POLE, UG CABLE LINKS, FEEDER PILLAR AND ALLIED WORKS AT INS SARDAR PATEL AND NAVAL AIR ENCLAVE UNDER GE NAVY PORBANDAR
Tender General Pages, Special Conditions and Particular Specifications of Contract
BOQ Items
2 core 6 Sqmm cross sectional area
100
-
-
2 core 10 Sqmm cross sectional area
100
-
-
2 core 16 Sqmm cross sectional area
100
-
-
2 core 25 Sqmm cross sectional area
50
-
-
4 core 10 Sqmm cross sectional area
600
-
-
4 core 16 Sqmm cross sectional area
600
-
-
3-1/2 core 25 Sqmm cross sectional area
100
-
-
3-1/2 core 35 Sqmm cross sectional area
100
-
-
3-1/2 core 50 Sqmm cross sectional area
60
-
-
3-1/2 core 70 Sqmm cross sectional area
80
-
-
3-1/2 core 95 Sqmm cross sectional area
80
-
-
3-1/2 core 120 Sqmm cross sectional area
100
-
-
3-1/2 core 150 Sqmm cross sectional area
40
-
-
3-1/2 core 185 Sqmm cross sectional area
20
-
-
3-1/2 core 240 Sqmm cross sectional area
20
-
-
Excavation in trenches in hard /dense soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
490.32
-
-
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site
422.28
-
-
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
68.04
-
-
S& F in replacement of laying of Double Walled Corrugated (DWC) HDPE pipe of following size of conforming to IS 16205 Part -24 including necessary bends,coupling ,tees, reducers, spacers,end caps, rubber rings etc having pressure rating not less than 450 N through trenches/wall/floor/on pole in any type of soil for protection of electric cable complete all as directed by Engr-In Charge.
-
-
-
40/32 mm outer/inner dia
1275
-
-
50/38 mm outer/inner dia
212.5
-
-
63/50 mm outer/inner dia
51
-
-
75/63 mm outer/inner dia
68
-
-
90/75 mm outer/inner dia
153
-
-
110/95 mm outer/inner dia
68
-
-
M & L for Cutting the existing PCC floor/road/foot path not exeeding 15cm width,30 cm depth for laying of UG cable/protection of pipe all as directed.
40
-
-
M & L for PCC type B1,1:2:4 using 20 mm graded stone aggregate all as specified and directed.
1.8
-
-
Supply & fix Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 50 mm dia along with necessary calmp nut bolt etc complete all as specified and directed.
36
-
-
Supply & fix Steel tubing GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 100 mm dia along with necessary calmp nut bolt etc complete all as specified and directed.
12
-
-
Taking down of faulty LT under ground cable of size upto 3.5x25sqmm from trenches /pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete.Note- Excavation /earth work and cable jointing &jointing kit shall be measured and paid for separately under relevent item of schedule.
60
-
-
Taking down of faulty LT under ground cable of size above 3.5x25sqmm up to150 sqmm from trenches /pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete. Note- Excavation /earth work and cable jointing &jointing kit shall be measured and paid for separately under relevent item of schedule.
60
-
-
Supply & Joint cable jointing kit heat shrinkable 1.1KV XPLE straight through joint of size 10 sqmm 4core to 16 sqmm 4 core cable size complete.
4
-
-
Supply & Joint cable jointing kitheat shrinkable 1.1KV XPLE straight through joint of size 25 sqmm 3.5 core to 50 sqmm 3.5 core cable size complete.
4
-
-
Supply & Joint cable jointing kit heat shrinkable 1.1KV XPLE straight through joint of size 70 to 150 sqmm 3.5 core cable size complete.
4
-
-
Relaying dismentaled Brick covering perpendicular to axis of cable as a mechanical protection to cable complete all as specified and as directed.
300
-
-
M&L of earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to galvanised earth strip 32x6mm size by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 2 of SSR Part-I all as specified and directed.
14
-
-
Dismantling of U/S existing cross arms by means made from channels, angles, U/S FI clamps, nuts, bolts etc. from OH line and removing complete.
2.5
-
-
S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
2.5
-
-
Dismantling of existing U/S HT/LT pole of any size & type from its position carefully and removing from the site and necessary excavation and earth work in any soil/strata, demolation of concrete, disconnection of conductor fom pole etc. complete all as directed.
6
-
-
supply and install steel, tubular swaged poles complete with cast iron base plate, nuts and taper plug , bolts, nuts and screws as specified type 410-SP- 31 (9.0 m long).
6
-
-
M& L Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
3.56
-
-
M & L for Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole complete all as specified and directed.
4.05
-
-
Taking down old u/s LT panel of any size/ make/ including all unserviceable parts removing from site all as directed & specfied at site
7
-
-
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 40 cm above floor mounted ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
1
-
-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 250 A TPN 25 KA (LEGRAND- 4202 19) -01 No (b) Onload Manual Change Over Switch Open execution type 250 A ,4 Pole (L &T Model No- CO32500OOOO) -01 No (c) MCCB 160 A TP 25 KA (LEGRAND- 4200 47) -01 No (d) MCCB 100 A TP 25 KA (LEGRAND- 4200 45) -01 (e) MCCB 63 A TP 25 KA (LEGRAND- 4200 43) -02 No (f) DOL Starter with push button 5 HP ,415 V (Havells- IHPDOLK1 )-2 Nos (g) All out going LT feeders name with radium stickers -06 Nos Note:- MCCB Make:- Legrand/L&T (d-sine series) /Schenider
-
-
-
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
1
-
-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 57) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 100A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 45) -01 Nos (b) MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos (b) All out going LT feeders name with radium stickers -05 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
-
-
-
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
1
-
-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 100X5 - 3 Nos (f) MCCB 160A TPN 25 kA with thermal magnetic release ( Legrand Cat No 420057) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 100A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 45) -02 Nos (b) MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos (c) All out going LT feeders name with radium stickers -06 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
-
-
-
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
1
-
-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 100A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 55) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos , (b) MCCB 40 A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 42) -01 Nos (c) All out going LT feeders name with radium stickers -05 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
-
-
-
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 200 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 60 cm above and 60 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
1
-
-
(A) Incoming:- (a) Copper bus bar TPN 200 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 100 A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 55) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCCB 63A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 43) -04 Nos , (b) MCCB 40 A TP 25 kA with thermal magnetic release ( Legrand Cat No 4200 42) -02 Nos (d) All out going LT feeders name with radium stickers -06 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
-
-
-
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 100 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 30 cm above and 30 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
1
-
-
(A) Incoming:- (a) Copper bus bar TPN 100 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 200X5 - 3 Nos (f) MCCB 100 A TPN 25 kA with thermal magnetic release ( Legrand Cat No 4200 55) -01 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a) MCB 63A TP ( Legrand Cat No 4086 61) -04 Nos (b) All out going LT feeders name with radium stickers -04 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
-
-
-
Supply , install, Design testing and commissioning of CPRI approved factory made and tested outdoor type floor mounted LT panel board, cubical type suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with air insulated PVC sleeved Copper bus bar of rating 500 Amps for phases and neutral installed on porcelain insulators. The panel shall be dust and vermin proof IP-54 class protection and made out of 3.15 mm CRCA MS sheet with projected globe roof for rain water protection Dust & Vermin proof, including Neoprene rubber gasket, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and 50 X 50 X 6 mm thick MS angle iron frame 45 cm above and 45 cm below normal ground level work front & back opening double door type of adequate size for housing LT switchgear and measuring instruments duly powder coated after seven tank process on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size but not less than 4.0 sq mm, cable lugs,MCCB Spreaders links, cable glands and PCC foundation in cement concrete 1:3:6 (20 mm graded stone aggregate, testing after installation including complete all as specified & directed and comprising of followings:-
1
-
-
(A) Incoming:- (a) Copper bus bar TPN 500 Amps - 01 Set (b) Voltmeter 3 phase class .5 (L &T Model No-WL131020OOOO ) -01 Nos (c) Ammeter 3 phase class1 (L &T Model No-WL132020OOOO ) -01 Nos (d) Phase indicating lamp R, Y, B LED (L &T Model No-EPL R/Y/B/240VAC ) - 01 Set (e) CT 500X5 - 3 Nos (f) MCCB 630 A TPN 36 kA with thermal magnetic release ( Legrand Cat No 4220 09) -02 Nos (g) Danger notice plate/ sticker of suitable size on front panel board -01 No (B) Outgoing:- (a)Onload Manual Change Over Switch Open execution type 630 A ,4 Pole (L &T Model No- CO463000OOOO) -01 No (c) All out going LT feeders name with radium stickers -02 Nos Note:- MCCB Make:- Legrand/L&T(d-sine series) /Schenider
-
-
-
S& F in replacement of MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
1
-
-
S& F in replacement of MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
1
-
-
S& F in replacement of MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
1
-
-
S& F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
1
-
-
S& F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
1
-
-
S& F in replacement of MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
1
-
-
Taking down partly unserviceable / unserviceable street / security light fittings from pole / tower/wall/hanger for necessary repaire to AGE E/M office and make serviceable in Store of office and note down the items required in the register as per complaints given by dept. through job card / complaint register on day to day basis & all as specified and directed by Engr-in Charge.
40
-
-
Fixing only repaired serviceable street / security light fitting in the yard of AGE E/M NRC of any size & any make on pole / tower /wall of the Hanger of 20 meter height/ Water Tank at 25 Meter height/on bldg of any height etc. complete. Note:- No ladder/T &P will be provided for fixing street light on pole/ wall/ hanger.
40
-
-
Supply & fix in repare digital time switches - Multifunctional digital time switches of Make- Legrand/L&T/SIEMENS
1
-
-
Supply & fix Power contactor ML-3, 3 pole rating not less than 40 A 230 coil Make : L&T / Siemens
2
-
-
Supply & fix in replacement of Led outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 75 Watt . Make:-As suitable in LED fittings of existing make
12
-
-
Supply & fix in replacement of Led outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 75 -100 Watt . Make:-As suitable in LED fittings of existing make
12
-
-
Supply & fix in replacement of Led outdoor driver 5 kv suitable for LED street light /LED flood light fititngs of capacity upto 100-150 Watt . Make:-As suitable in LED fittings of existing make
5
-
-
Supply & fix in replacement of Surge protection device of RATING 5KV suitable for LED street light /LED flood light fititngs of capacity upto 75 Watt . Make:-As suitable in LED fittings of existing make
20
-
-
Supply & fix in replacement of Surge protection device of RATING 5KV suitable for LED street light /LED flood light fititngs of capacity upto above 75 Watt & upto 150W Make:-As suitable in LED fittings of existing make
20
-
-
Supply & fix PVC insulated 3 core 1.5 sqmm multistranded Copper conductor on pole for security light from junction box to street light fititng including making necessaey hole on surface of pole for insertion of 3 core pvc cable inside the pole upto street light fitting as specified & directed. etc complete all as specified and directed. Make:- Polycab/Havells/Gloster
100
-
-
Supply & fix PVC junction box of size inside dimenssion 250x200x100 mm complete with industrial connector, including clamp made out of MS flat iron 30x5 mm, nut, bolts, washer ,glands etc, MCB 6-10Amps complete all as specified & directed.
38
-
-
M & L for Preparation of surface of LT pole i.e. scrapping by brushes, emery paper, caustic soda etc of LT pole 9m/11m long with all connected channel, cross arms caps etc painting one coat of aluminium paint over a coat of anti rusted paint as a primer on steel surfaces and One coat of primer and two coat of exterior acrylic emulsion paint (wheather coat) on Concrete surfaces including numbering by using white paint over a surface of black paint base of size 15cm x 15cm complete all as specified and as directed by Engineer-in-Charge.
Note :- Manpower will be provided by contractor per pole per tradesman for scraping of pole for one shut down & for outer rust painting for pole for second shut down the period will only one hour per shut down in various period and timing and day which will be framed by the department.
120
-
-
Taking down the High Mast light of any height including bracket by the means of crane and reinstallation to site after servicing, greasing of pulley ,chain, repalcement of rusted nut bolts to have smooth functioning of wire rope mechanism with help of high-capacity Hydraulic crane.
7
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements