Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Soon30 Nov 2024
Tender Amount₹ 10,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Comprehensive / Preventive maintenance including servicing of AHU shall be carried out as per manufacturer standard check list and detailed as under all as directed by Engineer-in-Charge. (a) Testing / Checking & servicing of blower fan motor and rectification of minor defect if any. (b) Testing / Checking of blower fan blade for proper functioningalong withchanging its bearing, oiling and greasing (c) Cleaning of cooling coil of AHU unit with pressurised water and then testing/ checking of Cooling coil for leakage and rectification of leakage by brazing including. (d) Testing / Checking of all electrical connection and control wiring tighting of electrical connection and rectification of minor defect if any complete. (e) Testing / Checking and Cleaning the moisture drain pipe. (f) Cleaning of entire AHU unit for removing all dirt dust, grease etc Note :- (i) The Contractor shall comprehensive / preventive maintenance including servicing each AC Plant twice during contract period . (ii) Each comprehensive / preventive maintenance including servicing shall be counted as one job for the purpose of payment. (iii) The time interval between both descaling will be intimated by Engineer-in-charge as per requirement.

-

-

-

... More
AHU unit 30 TR, 12000 CFM capacity, Make - Blue star

2

-

-

... More
AHU unit 08 TR, 3200 CFM capacity, Make - Blue star

2

-

-

... More
Supply & fix in repair 100 mm size butterfly valve with cast iron body, seat of black nitride rubber, nylon coated S.G. Iron disc, PTFE coated SS (AISI 410) shaft, companion flanges, nuts, bolts, gaskets etc, confirming to BS:5155 MSS SP.67 & API. 6098 and shall be designed to fit without gaskets between mating and seal in both direction. The valves shall be of integral moulded design, complete all as specified & as directed.

1

-

-

... More
Supply & fix in repair 80 mm size butterfly valve with cast iron body, seat of black nitride rubber, nylon coated S.G. Iron disc, PTFE coated SS (AISI 410) shaft, companion flanges, nuts, bolts, gaskets etc, confirming to BS:5155 MSS SP.67 & API. 6098 and shall be designed to fit without gaskets between mating and seal in both direction. The valves shall be of integral moulded design, complete all as specified & as directed.

2

-

-

... More
Supply & fix in repair GI damper of size 450x 450mm with open and close handle in the existing package AC duct complete all as specified & as directed.

1

-

-

... More
Supply and fix in repair 'V' belt of size A 849 LP/A32 of blower motor pakage11 TR of AC plant any type complete all as specified & as directed. Make : Fenner / continental/Dunlop / JK

12

-

-

... More
Supply and fix in repair 'V' belt of size B-78 of AHU motor of AC plant complete all as specified & as directed. Make : Fenner / Dunlop / JK.

4

-

-

... More
Supply and fix in repair 'V' belt of size A-50 of AHU motor of AC plant any type all as directed by the Engineer-in-Charge. Make : Fenner / Dunlop / JK.

4

-

-

... More
Supply and fixing in repair Oil/HP/LP pressure sensor Probe suitable for scroll Chiller unit of 40 TR central AC plant complete all as specified & as directed. Make:- Bluestar or equivalent make approved by GE.

1

-

-

... More
S&F in repair 2 pole front mounted add on Auxiliary contact block for power contactor, 1 NO & 1 NC contact including connecting complete all as specified & as directed. Make:- SIEMENS / L&T / ABB/ BCH / C&S / Legrand

1

-

-

... More
S&F in repair 4 pole front mounted add on Auxiliary contact block for power contactor, 2 NO & 2 NC 415 V including connectingcomplete all as specified & as directed. Make:- SIEMENS / L&T / ABB/ BCH / C&S / Legrand

1

-

-

... More
S&F in repair 3 pole power contactor 12A, 415 V, coil voltage 230 V, 1 NO & 1 NC including connecting complete all as specified & as directed.. Make:- CTX 22 legrand / SIEMENS / L&T / ABB/ BCH / C&S

1

-

-

... More
S&F in repair 3 pole power contactor 9A, 415 V, coil voltage 230 V, 1 NO & 1 NC including connecting complete all as specified & as directed. Make:- CTX 22 legrand / SIEMENS / L&T / ABB/ BCH / C&S

1

-

-

... More
S&F in repair 3 pole power contactor 60A, 415 V, coil voltage 230 V, 1 NO & 1 NC including connecting complete all as specified & as directed. Make:- CTX 22 legrand / SIEMENS / L&T / ABB/ BCH / C&S

1

-

-

... More
S&F in repair 1 pole front mounted add on Auxiliary contact block for power contactor, 1 NO or 1 NC contact including connecting complete all as specified & as directed. Make:- SIEMENS / L&T / ABB/ BCH / C&S / Legrand

1

-

-

... More
S&F in repair compressor over load protection type current rating 16-22 Amps rated voltage 415V, 50HZ including connecting complete all as specified & as directed. Make:- SIEMENS / L&T / ABB/ BCH / C&S / Legrand

2

-

-

... More
M&L for taking out blower fan motor of capacity 2.2 HP from package type AC plant of capacity 11 TR, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate,shaft replacement and balancing, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & as directed

1

-

-

... More
M&L for taking out blower fan motor of capacity 2HP from AHU type capacity 8 TR, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings,shaft and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & as directed

1

-

-

... More
M&L for taking out Chilled water pumps 7 HP replacing the impleller, bearing, gasket and refixing it in same position with proper alignment with motor complete all as specified & as directed

1

-

-

... More
M&L for taking out Chilled water pumps 7 HP opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings,shaft and base plate, reassembling, refixing in same position & connecting with coupling shaft including testing and commissioning complete all as specified & as directed

4

-

-

... More
M&L for taking out blower fan motor of capacity 10 HP from AHU type capacity 30 TR, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings,shaft and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & as directed

1

-

-

... More
Supply and fix in repair of 100 mm dial type Pressure Gauge with appropriate range & SS valves and SS tubing complete all as specified and as directed. Make:- GURU / EMRALD / D S ENGG / GLUCK

10

-

-

... More
Supply and fix in repair of set of individual confirm 150 mm dial type Temp Gauge with appropriate range & SS valves and SS tubing complete all as specified and as directed. Make:- GURU / EMRALD / D S ENGG / GLUCK

7

-

-

... More
Supply and fixing in repair Expansion valve for water cooled chiller AC plant (of Make : Bluestar ) capacity 40 TR (Make:- As per manufacturer recommadation after written approval by GE)

1

-

-

... More
Supply and fixing in repair Expansion valve for package type AC plant (of Make : Bluestar Model No : DPA1321) capacity 11 TR complete all as specified and as directed. (Make:- As per manufacturer recommadation after written approval by GE)

1

-

-

... More
Supply and fix in repair of Supply / Return air Diffusers / Grilles of extruded Aluminium sections duly powder coated with black volume control Damper complete all as specified and as directed. (Make: DYNACRAFT / COSMOS / AIR MASTER )

1

-

-

... More
Supply and fixn repair of 50mm thick glass wool fiber insulation with Aluminium foil and 28 H perforated Aluminium sheet all as specified and as directed. complete all as specified and as directed.

10

-

-

... More
Supply and fix in repair of 20mm thick nitrile duct insulation complete all as specified and as directed.

10

-

-

... More
Supply and fix in repair of 40mm thick TF Quality thermocole insulation complete as specified and as directed.

10

-

-

... More
supply and fix in repair of site fabricated MS channel/angle support structure/pipe rack for the piping ,cassate units, FCUs and ducting work, complete all as specified and as directed.

20

-

-

... More
Supply and installation in repair of insulation with using 12 mm thick open cell Nitrile Rubber for pipe duct / plenum, complete all as specified and as directed. Make: Armaflex/ Aeroflex/ Durkee

10

-

-

... More
Supply and fix in repair of 25 Auto air purge valve/ for chilled water pipingt complete all as specified and as directed.

2

-

-

... More
Providing and fixing replacing in position of approved make AFT valve complete with Aluminum control wiring at chiller outlet complete all as specified and as directed.

4

-

-

... More
Comprehensive maintenance / basic servicing of chilled water 4 way cassette unit /FCU up to 4.0 ton capacity of any make, maintenance carried out by cleaning of filter and condenser coil of indoor units with pressure spray of water cleaning of strainer and testing the serviceability of wiring (cost of change of wire and cables included) of units complete all as specified and as directed.

14

-

-

... More
Comprehensive maintenance / servicing and deep cleaning of chilled water 4 way cassette unit /FCU up to 4.0 ton capacity of any make, maintenance carried out by taking down complete unit and cleaning of condenser coil of indoor units with descaling solution,testing by applying water pressure and removing and choking, cleaning of strainer and testing the serviceability of wiring (cost of change of wire and cables included) of units complete. Note for item No 35 & 36 :- (i) The Contractor shall comprehensive / preventive maintenance including servicing each chilled water 4 way twice during contract period . (ii) Each comprehensive / preventive maintenance including servicing shall be counted as one job for the purpose of payment. (iii) The time interval between both descaling will be intimated by Engineer-in-charge as per requirement. (iv) The rates quoted by the tenderer shall be deemed to include for any minor repair, which are obviously and fairly, intended which may not have been included in these documents, but which are essential for the execution and entire completion of works. The decision of the Engr-in-charge as to what constitutes Minor details of the construction’ shall be final and binding. (v) Spares such as , fan blade, blower motor,thermostat, if found defective will be measured & paid separately as supply & fix in repairs.

10

-

-

... More
S&F in repairs of coil sensor for four way chilled water type cassatte units/FCU unit AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etc, complete all as specified and as directed.

2

-

-

... More
S&F in repairs of temperature sensor for four way chilled water type cassatte units/FCU unit AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etc. all as specified and directed by Engineer-in-charge.

3

-

-

... More
S&F in repairs of drain pump for four way chilled water type cassatte units/FCU unit AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etc complete all as specified and as directed..

4

-

-

... More
S&F in repairs of float valve for four way chilled water type cassate units/FCU unit AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etc, complete all as specified and as directed.

4

-

-

... More
S&F in repairs of PCB suitable for four way chilled water type cassate units/FCU unit AC 1.5/2 ton capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etccomplete all as specified and as directed..

2

-

-

... More
S&F in repairs of 2 way actuater valve suitable for four way chilled water type cassette units/FCU unit AC any capacity of Make LG / Carrier / Voltas / Blue Star along with necessary electrical connections including spare parts etc complete all as specified and as directed.

4

-

-

... More
Supply and fix in repair fan blade suitable for outdoor unit of Air cooled package AC of 11 ton capcity Bue star complete all as specified and as directed.

6

-

-

... More
Supply and fix in repair condensing unit fan motor suitable for outdoor unit of Air cooled package AC of 11 ton capcity complete all as specified and as directed.

1

-

-

... More
S&F replacement of fan motor of chilled water four way cassette unit AC 1.5/2/3/4 ton capacity of Make Carrier along with necessary electrical connections including spare parts etc. complete all as specified and as directed.

4

-

-

... More
S&F in repairs of fan blade of chilled water four way cassette unit AC 1.5/2/3/4 ton capacity of Make / Carrier r along with necessary electrical connections including spare parts etc. complete all as specified and as directed.

2

-

-

... More
Supply & fix in repairs pre filter 10 micron of size 610x610x50mm AHU chiller unit complete all as specified and as directed. Make: THERMADYNE or equivalent make approved by GE.

6

-

-

... More
Supply & fix in repairs in pre filter 10 micron of size 395x483x25mm AHUchiller unit complete all as specified and as directed. Make: THERMADYNE or equivalent make approved by GE.

6

-

-

... More
Supply & fix in repairs micro controller PCB card for 11 TR Air cooled chiller unit complete all as specified and as directed. Make: copeland model SZ185S4RC or equivalent make approved by GE.

1

-

-

... More
Supply & fix in repairs contactor 3 pole ,240 V,32 amps for Package AC panel complete all as specified and as directed. Make:-CHNT NC 3201 or equivalent make approved by GE.

1

-

-

... More
Supply & fix in repairs contactor 3 pole ,240 V,18 amps for Package AC panel complete all as specified and as directed. Make:-CHNT NC 1801 or equivalent make approved by GE.

1

-

-

... More
Supply & fix in repairs suction line accumulator for blue star package AC of 11 ton capcity . Make:- Danfoss/Emerson or equivalent make approved by GE.

1

-

-

... More
Supply and fix in repair HP cutout switch for compressor ofr 11 TR blue star pakage unit complete all as specified and as directed. Make dafnoss or equivalent make approved by GE.

1

-

-

... More
Supply and fix in repair LP cutout switch for compressor of 11 TR blue star pkage conditioning unit complete all as specified and directed by Engg -in-charge Make dafnoss or equivalent make approved by GE.

1

-

-

... More
Supply and fix in repair Filter drier for 11 TR pakage AC make blue star Air conditioning unit complete all as specified and as directed. Make Dafnoss or equivalent make approved by GE.

1

-

-

... More
Supply and fix in repair temperature controller remote for 11TR blue star Pakage AC unit complete all as specified and as directed.

1

-

-

... More
Supply and fix in repair chiller micro computer control panel with displaywith PCB card for 40 TR blue star air cooled chiller unit complete all as specified and as directed. Make: Blue star model no XAC2YS 048AR2 or equivalent make approved by GE.

2

-

-

... More
Supply and fix in repair 3 pole MCB 40A-63A 415 V , 'C' grade complete all as specified and as directed.

4

-

-

... More
Supply and fix in repair 3 pole MCCB 630 Amp 50 ka rated with thermal magnetic setting complete all as specified and as directed.

1

-

-

... More
Supply and fix in repair 3 pole MCCB100 Amp 16 Ka rated with thermal magnetic setting complete all as specified and as directed.

2

-

-

... More
Supply and fix in repair selector rotary switch having 3 postion 63 amp rated complete all as specified and as directed. Make: L&T or equivalent make approved by GE.

1

-

-

... More
Supply and fix in repair MFM meter having following parameters, voltage L-L,Voltage L-N current phase wise frequency ,run hours, Aux supply 90-270AC/DC complete all as specified and as directed. Make: VERITEK VIPS 69 or equivalent make approved by GE.

1

-

-

... More
Supply and toping up refrigerant gas R-407 C to the central / package AC plant of any capacity system complete all as specified and as directed.

120

-

-

... More
M&L for painting of 40 TR chiller plant out door unit complete all as specified and as directed.

4

-

-

... More
Supply and fix in repair rubber spider for jaw coupling L-110 star complete all as specified and as directed.

8

-

-

... More
Supply and fix in repair steel jaw couling L-110 for motor complete all as specified and as directed.

1

-

-

... More
Supply and fix in repair GIC voltage controller Make: VERITEK VIPS 70 or equivalent make approved by GE.

1

-

-

... More
Material & labour checking leakge in Air cooled package air conditioner of capacity 11 TR after flushing the complete system, vacuum testing, Nitrogen filling and the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete.

3

-

-

... More
Material & labour for checking leakage central air cooled chiller capacity 40 TR after flushing the complete system, vacuum testing, Nitrogen filling and the repairing the leaking tube / lines by brazing, charging the unit as per manufacturer instruction complete all as specified and as directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.