Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 64,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_633915_1Bid Award Id
ViewTender No
8265/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking down and Re-Fixing street light fitting of any size with MS clamp & GI bracket & connected complete including junction box all as directed.
20
-
-
S&F in replacement of LED Street Light fitting 90 Watt, system efficiency not less than 100 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, aesthetic aluminium powder coated housing with fresnal diffuser with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting complete all as directed complete. Make:- Wipro Cat part no. LR06-102-XXX-57-XX or equivalent of makes as mentioned in Appx'BB' of P.S
15
-
-
Supply & fix in replacement of weather proof, PVC insulated, PVC sheathed, cable, with multistrandard aluminium conductor of size 2.5 Sqmm, 2 core, fixed from Junction box to street light fittings complete all as specified and directed.
260
-
-
S&F in replacement of 25 mm dia heavy duty, rigid non metallic PVC conduit inclusive fitting etc fixed on pole with mild steel clamps, nuts and bolts complete.
260
-
-
S&F in replacement street light bracket fabricated from 40 mm bore galvanised iron tubing light grade, 1.5 metre long, bent to shape fixed on pole / bldg including mild steel flat iron clamps, nuts, bolts etc complete all as specified and directed.
17
-
-
Supply and fix in replacement junction box of size 200 mm x 150 mm x 100 mm made of FRP with double stud hinged door locking, including MCB 06 amps-01 No with dinrail for mounting MCB including suitable connector for looping and duly sealed with rubber plugs, fixed on pole with necessary clamp, nut, bolt etc all as directed by Engr-In-Charge.
37
-
-
S&F in repairs Tubes, 'Medium grade', galvanised, mild steel of 40mm dia with all fitting; laid in trenches / wall for protection of underground cable complete with fittings and fixtures.
56
-
-
M &L Plain cement concrete 1:3:6 type C2 (using 40 mm aggregrate) in base & foundations of electric poles, stays structs etc including necessary form work and fair finish to exposed surface without using extra cement etc complete all as specified and directed
7
-
-
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1 platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer including taking down old unserviceable existing LT Panel board...
2
-
-
.. with all accessories all as specified and as directed comprising the following:-(i) Bus bar chamber consisting of four Nos copper bus bar duly sleeved of capacity 200 Amps for phases and 160 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.
(ii) Multifunctional digital type meter showing ampere, voltage PF phase to phase & phase to neutral . Make :- Secure/conserve/Legrand.
(iii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(Make:-Siemens/L&T/Telematic)
(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors.
(v) MCCB 160 Amps,415V, 4 Pole, 35/36 KA - 01 No (In coming)
(vi) MCCB 100 Amps, 415V, 4 pole, 25 KA - 01 Nos (Out going)
-
-
-
(v) MCCB 63 Amps,415V, 4 Pole, 25 KA - 01 No (Out going)
(vi) Change over switch 160 Amps- 01 Nos Note :- The LT Panel board shall be made of suitable size to accommodate the above fittings and should be fixed 1.2 metre above ground level . Quotted Rate should also include excavation , earth work and PCC work complete with testing all as specified and directed by Engineer -in-Charge. .
-
-
-
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT Panel board, confirming to IS 5039 with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 60 x 60 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old panel all as specified and directed & Consisting of the following equipment's:-
(a) MCCB 415 Volt 120 Amps, 4 Pole, 16KA-01 (Incoming) (b) MCB 415 Volt 32 Amps, 4 Pole 10 KA-02 Nos (Outgoing)
1
-
-
(c) Solid copper bus bar 200 Amps for 3 Phase supply.
(d) Solid copper bus bar 100 Amps for neutral. (e) Volt meter 0- 500V - 01 with selector switch (f) Ammeter 0- 30 Amps - 01 with CTs & selector switch (g) timer switch of suitable capacity
(h) Power Contactor MNX70
(I) Auto mannual switch - 0 1 Nos (j) Reverse forwarding switch for lifting and lowering of high mast light fitting
-
-
-
Material and labour in replacement for provision of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to and including galvanised mild steel strip 32 x 6 mm by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including.....
6
-
-
.....all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note : (i)Earth result after installation completely should be less than 5 Ohm . (ii)Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length.
-
-
-
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V.
19
-
-
Supply and fix flame proof and weather proof industrial type DBs with and including various combination of incoming and outgoing flame proof MCBs suitable for and including (a) 01 No MCB SPN 40 Amps, C type (incoming) (b) 07 Nos MCB SP 10 Amps C type, including necessary connection, complete, all as specified and directed.
1
-
-
S&F of flame proof weather proof flood light fitting suitable for & including 90 watt LED chips, in cast aluminum alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed.
19
-
-
Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection,luminaire with aluminium die-cast housing,toughened glass and unique lens system for enhanced illumination with impact and corrosion resistant complete with driver and lamp. Make:- Wipro Cat part no. LF30-272-060-57-XX or equivalent of makes as mentioned in Appx'BB' of P.S
24
-
-
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with
aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
220
-
-
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with
aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
280
-
-
Supply & laying LT underground cable XLPE insulated, armoured heavy duty electric cable with
aluminium conductor, 1100 volts grade, cross-sectional area 25 sq. mm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
2299
-
-
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or
for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc
1.5 m in depth and getting out soft / loose soil.
480.53
-
-
Excavation in trenches not exc 1.5 m wide and n.exc in depth beyond 1.5 m for foundation / fixing of pole / laying of cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in Hard/Rock/Rcc/Pcc soil all as specified.
7
-
-
All as per item no 23 above but depth exceeding 1.5M & not exc 3 .0M.
0.1
-
-
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.
194
-
-
Removing excavated material (soil) exc. 50m but n.exc 100 m and depositing where directed at a level n exc. 1.5 m above the starting point.
272.19
-
-
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable all as specified and directed.
15790
-
-
M&L for providing dry river sand as in sand cushioning to under ground PVC cable including punning down of sand in layer all as specified and directed. (Note: Work shall be executed as per clause 19.75 of standard schedule of rates part-1 (2009). For measurement purpose thickness of sand after punning down will be considered.)
192
-
-
M &L Plain cement concrete 1:4:8 type D2 (using 40 mm aggregrate) in base & foundations of electric poles, stays structs etc including necessary form work and fair finish to exposed surface without using extra cement etc complete all as specified and directed.
0.1
-
-
M &L Plain cement concrete 1:2:4 type B1 (using 20 mm aggregrate) in coping of electric poles including necessary form work and fair finish to exposed surfacewithout using extra cement etc complete all as specified and directed
0.3
-
-
Supply and installation, testing, commissioning, factory made, CPRI approved, outdoor type, LT panel board, confirming to IS 8623 with IP-54 protection, made out of 3.15mm thick CRCA sheet, 415 volt, 3 phase, 50 HZ supply mounted on and including MS angle section 40x40x5mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof, gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specified and directed & connecting of the following equipments :-
1
-
-
Incoming:-(a) MCCB 4P, 415 Volt 63 Amp 16 KA - 01 No (Incoming)
(b) MCCB 4P, 40 Amp, 10 KA - 01 No (c) 15 amp switch socket board-04 nos (d) MCB SPN 20amps-04nos (e) Auto Manual selector switch - 01 No (f) R - Y - B Indicator lamp set - 01 No (g) Timer switch clock type - 01 Nos (h) Solid aluminium bus bar 100 Amps for 3 phase 50 amp for neutral (j) Digital multifunction meter (k) Suitable sizes of cable gland. Note:- Quoted rates shall be deemed to include for grounting the panel appx 4 inches above the ground level / fixing of panel in PCC 1:3:6 type C2 and PCC block masonry with PCC block of mix 1:5:8 & plastering 10mm thick in CM 1:6 complete all as specified and directed by Engg-in-Charge.
-
-
-
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Marked) not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
310
-
-
Material & Labour for sub main wiring with 2 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Marked) not less than 25 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
262
-
-
Material & labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and
inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
0.4
-
-
Supply and fix junction box of size 200 mm x 150 mm x 100 mm made of FRP with double stud hinged door locking, including MCB 06 amps-01 No with dinrail for mounting MCB including suitable connector for looping and duly sealed with rubber plugs, fixed on pole with necessary clamp, nut, bolt etc all as directed by Engr-In-Charge.
6
-
-
Supply and erecting prestressed concrete pole, 9.0 metres long, 102mm x152mm at top and 102mm x 289mm at bottom, class 10 all as specified and directed
3
-
-
Supply & fix weather proof, PVC insulated, PVC sheathed, cable, with multistrandard aluminium conductor of size 2.5 Sqmm, 2 core, fixed from Junction box to street light fittings complete all as specified and directed.
180
-
-
S&F 25 mm dia heavy duty, rigid non metallic PVC conduit inclusive fitting etc fixed on pole with mild steel clamps, nuts and bolts complete.
160
-
-
S&F brackets to be mounted on pole made of steel angle 40x40x5 having length1.5mtr with holes for mounting of flood light at any height as directed by Engineer in Charge
6
-
-
Material and labour for provision of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to and including galvanised mild steel strip 25 x 4 mm by means of bolts, nuts, check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including.....
2
-
-
.....all excavation, earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note : (i)Earth result after installation completely should be less than 5 Ohm . (ii)Quoted rates shall be deemed to include for earth strip with protection pipe of 7.5 M length.
-
-
-
Material and labour for provision of tripod chemical earthing as per drawing attached (Sketch No 01). The chemical earthing will have specification as follows :- (a) Copper electrode of wall thickness minimum 2 mm not less than 3 mtr length with not less than 75mm outer dia . (b) Fixing of copper Earth Electrode by drilling / boring 175 mm dia hole, 5.00 mtr deep in any type of strata, placing electrode in hole, return filling excavated soil by mixing min 10 kg GEL per bore and 75 kg Soil Resistivity Improvement (SRIP) compound as per manufacturer instruction
1
-
-
c) FRP earthing result display board 254 x 380mm made out of plastic material showing information related to type of earthing, earthing result, due date of testing along with fixing size 610mm height made of plastic hollow pipe of dia 20 mm. (d)Heavy duty poly plastic Earth pit cover of HDPE material, green color, Bottom diameter ( OD 320 mm / ID 290 mm) of wall thickness 5 mm, height 260 mm with top cover, fixed in position as per manufacturer instruction complete by use of pCC around the cover for setting it properly on ground surface.
-
-
-
(f) Contractor must visit the site before quoting the tender to understand the difficulty and cost for carrying out the job in the station. It is important that contactor ascertain the quantum of work. (g) Contractor must produce the certificate from the manufacturer that chemical earthing has been carried out by manufacturer. (h) Extension strip from electrode strip up to 0.15 m height from GL and interconnecting strip of electrode shall be deemed included in quoted rate including brazing. (g) Earthing resistance result shall be less than 1ohm.if the result comes more than 1 ohm ,the contractor shall carry out the earthing at seperate location /sie given by engg- in- charge after taking out of earth electrode without any extra cost to the department.
-
-
-
Supply and fixing of RCBOs double pole 30mA, rating 40A FOR EARTH LEAKAGE, OVERLOAD & SHORT- CIRCUIT PROTECTION with enclosure all as specified and directed by Engg-in-charge
1
-
-
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB 40amp 240V all as specified and directed.
1
-
-
Supply and fix of flame proof and weather proof metal clad triple pole and earth enclosure industrial plug and socket with suitable size of flame proof MCB triple pole 63 Amps C, in aluminum alloy LM 6 Construction, certified by CMRS, Dhanbad for Group I, IIA, IIB, including necessary connection complete all as specified and directed.
3
-
-
Supply and fix Voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second and of capacity 25 KVA complete all as specified and directed.
1
-
-