Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 3,35,000Document Cost
₹ 2,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_634272_1Bid Award Id
ViewTender No
89399/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply & install ,testing and commissioning of transformer as per IS : 1180 part - I, level - II ,step down, copper wound 11KV/433 Volts (at no load) AC 3 phase 50 Hz 160 KVA capacity, core type, oil immersed naturally air cooled, oil natural air natural (ON/AN) , with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with neutral brought out on secondry side (LV) and having taping at +5% to 10% in steps of 2.5% on HV side to be changed by means of hand operated off load tap changergear. The maximum temperature rise should not exceed 50 degree celsius in oil and 55 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree celsius transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade crgo with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076and as per IS-1180 part - I of 2014 marked and shall comprise of the following :-
2
-
-
... More
(a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods, complete with nuts and washer , with cable glands suitable for reception/taking out 3 core 120 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete.
(b) One cable box on LT side(secondary side) consisting of four nos porcelain bushing with copper rods, complete with nuts and washers, with cable glands suitable for reception/taking out single core 1000 sqmm, LT 1100 volts grade, PVC/XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete.
(c ) conservator with filter type drain valve and oil level guage.
(d) De-hydrating breather with first fill of dehydrating agent (Silica Gel).
(e) Explosive vent, Thermometer pocket on tank cover, oil level guage, Oil drain filter valve, Lifting ligs,oil filling hole with cap/plug with connection plate complete, Air release valve plug and four nos plain solid cast steel detachable rollers.
(f) One no 100 mm dia, dial type thermometer, vapour pressure type, having range 0-120 degree celsius with metal guard having maximum perimeter temperature reading indicator with re-setting device.
(g) Two earthing terminals on tank cover to facilitate fixing of 50x6mm galvanised iron earth strip for earthing of body.
(h) Rating plate and terminal marking plate.
(j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral.
-
-
-
... More
(k) First fill of new and unused transformer oil, IS-335 of 1986 marked, filtered and tested upto 50 KV dielectric strength at 2.5 mm air gap between testing electrodes, specific resistance at 27 Degree celsius Ohm-om 500 x 10 the power12, water content 50 PPM, Dielectric dissipation factor (tan Deta at 90 degree celsius) 0.005, Neutralisation value mg of KOH/gm of oil 0.03, Inter facial tension N/M at 27 Degree celsius - 0.04, flash point 140 Degree celsius and sluge 0.1 % by weight.
(l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer.
(l) Providing adequate size and nos of channels, embeded in floor, for movement of transformer.
(m) Tranformer losses shall not exceed the loses mentioned in Table 6 of IS: 1180 of 2014 Part - I with energy Effeciency level - II
(n) Oil temperator indicator , winding temperature indicator, marshlig box single window, double flit buchhols relay with alarm and trip contact including connection to existing RMU/VCB relay with PVC insulated PVC sheathed cable galvanized steel strip or wire armoured electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm 10 core 1100 volts grade.
NOTE :- (i) Rate quoted includes the cost of making and Testing of controll wiring connection at the Transformer and RMU/VCB for the Temperature alarm/Trip, Gas alarm/Trip. (ii) Controll cable shall be measured and paid seperatly.
(o) First fill of transformer oil conforming to relevant ISI and tested upto 60 KV dielectric strength.
(p)Two No lifting hook at side of transformer
(q) 1Nos Breather duly filled with silicajel crystals capacity 500g
-
-
-
... More
Disconnecting, Taking Out and shifting of the any make of transformer rating 100 KVA mounted on plinth/pole from existing location to new location and existing transformer vice versa, including removing and reconnections of HT/LT side, jumper / cable connection, control cable connection of both transformers including testing and commission complete all as directed by Engr-in-Charge. Note:- (i) The rate quoted is deemed to be inclusive of necessary crane / vehicle charges for shifting and installation of the transformer.
2
-
-
... More
Disconnecting, Taking Out and shifting of the any make of transformer rating 160 KVA mounted on plinth/pole from existing location to new location and existing transformer vice versa, including removing and reconnections of HT/LT side, jumper / cable connection, control cable connection of both transformers including testing and commission complete all as directed by Engr-in-Charge. Note:- (i) The rate quoted is deemed to be inclusive of necessary crane / vehicle charges for shifting and installation of the transformer.
1
-
-
... More
Providing platform for transformer of size 3.0x3.0x1.5m high from GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in copping, plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick, as in flour PCC 1:2:4 type B1 100mm thick floor using extra cement returning filling and removal on surplus soil, including 2 Nos ISMB 100mm channel painting with 2 coat aluminium paint over a coat of red oxide primer and 3 coats of white washing on cement work for fixing transformer including ramp of suitable size mounting of transformer complete all as specified and as directed.
8
-
-
... More
Supplying, installation, testing and commissioning of 11 KV 630 Amps having short circuit capacity 21 KA for 3 Sec Outdoor (IP54), RMU (Ring main unit) 3 – way comprising of 02 Nos. motorized operated load breaker witch and 01 nos. 630 Amps fixed type motorized spring charging VCB electrolytic grade copper busbars all inside single, gas filled, welded stainless steel 304/441 or better IP 67 Degree of Protection tank with min thickness , 2 to 2.5 mm thick for load bearing member and 1 to 1.6 mm for non load bearing member, internal arc classification, 21 KA for 1 sec on site repairable with site replicable / coupling / mechanism, etc. The enclosure shall have pad lockable doors as per OEM design, fully covering the front facia and cable boxes ensure fail safe anti theft protection. The unit along with Bus connected, fixed type Auxiliary transformer shall include the following along with all necessary accessories and fittings are required at site Make – ABB/ SIEMENS / C&S / SCHNEIDER
6
-
-
... More
(A) Incoming Load Break Module - 02 Nos each consisting of following accessories:
(i) Each switching – unit is designed as a three position switch. This three function switch combines the function of switch – disconnector an earthing switch
(ii)11 KV, 630 A Load Breaker Switch with interlocking line -earthing scheme both short circuit current ,21 KA for 3 Sec Making capacity – 50 KAp- 01 No
(iii)Auxiliary contacts – 1 NO + 1 NC- 01 No.
(iv)Spring – assisted motorized mechanism with un-inhabited operating shaft for emergency manual operation with integrated earthing switch – 01 No
(v)Cable terminals cable bushing situated not beyond 300 mm or as per ORM tested design from cable cover to allow ease of access for installation /testing/replacement purpose) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access of size upto 11 KV, 300 Sq mm, 3 Core, along with XLPE AL cable termination / End Kits Each set of 03 .
(vi)Right angle boots (push on type) Each set of 03 (vii)Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No.
(viii)Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set
(ix)Fault passage indicator – It is to be provided for each incomer Load break unit, FPI with LED / digital display to be added to detection of cable fault – 01 No
(x)ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 No Cable cover standard - 01.
-
-
-
... More
(B) 01 Nos., outgoing VCB module each consisting of following accessories: -
i)Each function – unit consists of a vacuum – circuit breaker in combination with a three position – switch. The three-position switch fulfils the operation of the disconnector – function and earthing function.
ii)11 KV, 630 Amps Fixed type VCB module with series disconnector cum earthing switch of short circuit breaking current / withstand –, 21 KA for 3 Sec Making Capacity – 50 KAp - 01 No
iii)Auxiliary contacts – 1 NO + 1 NC- 01 No.
iv)Stored – energy motorized high – endurance spring charging mechanism (M1+), with inbuilt spring charging lever and mechanically latched ON/OFF push -buttons to allow handle – less and un-inhabited operation – 01 No.
v)Cable terminals cable bushing situated not beyond 300 mm or as per OEM tested design from cable cover to allow ease of access for installation/testing/replacement purpose) with door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access up to 11 KV, 185 Sq mm, 3 Core, along with XLPE AL cable termination Each set of 03
vi) Right angle boots (push on type) Each set of 03 vii) 3 O/C + 1 E/F self-powered numerical protection relay with low and high set for Over current and Earth Fault. Relay should have facilities to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping. Relay shall be communicable with RS 485 Port on MODBUS Protocol. – 01No/ per VCB ougoing
viii) Relay for OTI / WTI / B – relay protection – 01 No
ix)Associated ring Core cast- resin insulated CT s 50/1 Amps, 2.5 VA, 10 P 10 Protection – Each set of 3
x)Arc proof cable covers having cable entry from bottom, front with interlocking mechanism including earth switch – 01 No.
xi)Capacitive voltage indication fixed type system as per IEC 6123 with LED – 01 Set
xii)ON, OFF, Earth mechanical indication on the front mimic of the panel – 01 No
xiii)Emergency trip push button – 01 No
-
-
-
... More
(C) 01 No Bus – connected, fixed – type Auxiliary transformer with floor- mounted compartment of matching height and depth, positioned along – side RMU to provide required aux. supply for spring charging motor and metering consisting of following accessories:
i)1-Ph (11 KV / rt3): 230 VAC, 500 VA Auxiliary transformer – 01 No
ii)2X12 Volt DC battery – 01 Set
iii)Battery charger – 01 No, with indiacation of status of functioning
iv)HRC fuse links for primary side isolation and AC/DC MCBs for secondary isolation – 01 Set
v)Voltmeter & RYB LED indications to confirm AC/DC supply availability – 01 Set
vi)Anti – condensation space – heater – 01 No
vii)CFL lamp for illumination and 3 pin socket with switch – 01 No (D) Standard mano meter -01 for each tank, Operating handle - 02 , cable clamping provision(standard)-01 /for every cbale enrty ,Operation and maintance manual - o1, installation and commissioning manual - 01, Foundation as per OEM Recomendation ( Earth Work and PCC works) for placing RMU on plinth is deemed to be included in the cost quoted. Height of plinth should not be less than 0.45 mtrs from ground level.
NOTE :- (a)The above module consisting of Load break Switchs and VCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including installation on plateform as recommended by OEM complete.
-
-
-
... More
Supply , install, testing and commissioning of indoor type HT vacuum circuit breakers panel having 1 No Incoming and one out going VCBs of each capacity 11 KV, Minimum 630 Amp, 3 Phase, 3 wire, 50 Hz, having 26.3 KA breaking capacity, all specified as per IEC 62271-100 & IEC 62271-200 totally enclosed single bus bar for each phase, floor mounting, metal clad, flush fronted, horizontal draw out type, horizontal. isolation type, Indoor extensible type, with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assembly of 3 vacuum interrupters, with epoxy support insulations and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks ( for insertion and withdrawal of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker , all standard fitting and accessories of following :- SPECIFICATION FOR VCB:-
(a) Bus bar chamber with 3 phase copper bus bar 1000 Amp rating duly insulated - 01 Set ( set of three). (b) Electrical trip coil 30 V DC /110V DC - 1 No
(c) Electrical shunt coil 30 V DC/110VDC - 01 No (d) CT Chamber incorporating 3 Nos single phase rasin cast current transformer ratio 200/100/5-5 class 1.0 for metering & class 5P10 for protection and burdon 15 VA , 11 KV, 25 KA for 1 sec - 1 No
(e) 3 Phase, 3 Limb draw out type bus connected Epoxy potential transformer, ratio 11KV/√3/110V/√3 AC accuracy 1.0, burdon 50 VA - 01 No.
(f) Digital ammeter 0 to 200 Amp,( 100% of CT ratio)for 3 phase -01 No.
(g) Digital voltmeter rating 0 to 12 KV, for 3 phase - 01 No
(h) DIGITAL Load manager for amps, volts, KW, KVA, KVAR, and PF Make :Conserve EM 6400 or Make: Secure Ellite 443 - 01 No
2
-
-
... More
(j)Three phase over current and earth fault digital numeric relay (over current (INST 50) & IDMT - 51 - 3 pole & earth fault (INST (50N) & INST (50N) & IDMT 51N - single pole) & negative sequence 46 auxiliary supply 20-110V AC/DC CT out put contacts 2 Nos + NC, rating-5, O/C Is= 20-200% in step of 5% E/F Os=5-80% in step of 5%. with common port ,the features and specification confirming to model No. MI COM P 122 of AREVA or equivalent Make of ABB -REJ601 or Seimen 7SR10.
(k) Auxiliary relay with 6 N/O & 6 N/C Make Alstom/ABB/L&T - 1No (l) Master trip circuit Make Alstom/ABB/L&T- 1No (m) TNC switch and LR switch - 1No
(n) Heat control switch - 1 No
(o) RYB, ON/Off , spring charred and discharged & VCB trip indications- 1 set
(p) Space heater with thermo state & toggle switch - 1 No
(q) Operating counter - 1 No
(r) Rear and side cable box suitable for 95/ 120 Sq.mm 3 core XLPE cable (s) Spring charging motor with starter 230V AC - 1 No
(t) Pluggable anti-pumping relay type CRM 4 with base- 1No
(u) Pluggable AC fail relay type CRM 4 with base -1 No
(v) Pluggable DC fail relay type CRM 4 with base -1 No
(w) CB contact multifunction relay type PSU14(52X) -1No
(x) 12W Annunciator + hooter- 1 set
(y) Power pack 230V AC-110V DC
(z) Control MCB/ Fuse set - 1set
(aa) Panel illumination lamp with door limit switch - 1set
(ab) Push button for TCH - 1 No
(ac) 9 KV , 10 KA , surge arrestor - 1 set of three
(ad) Indicating lamp - 1 set
NOTES :- (i) VCB shall be extensible type.
(ii). The contractor shall get the approval of GE for the make of the VCBs they plan to procure.
(iii). Prior to manufacturing the general arrangement drawing design details of the VCB panel shall be got approved by GE.
(iv) Electrical shunt coil 30 V DC/110VDC – 01 No (v) Erections commissioning and civil work (Plinth protection) with PCC /Brick work for installation of VCB is deemed to be included with unit rate. The plinth protection details as per the manufacturer instruction.
-
-
-
... More
Material and labour for making Ring main unit platform suitable 4/5way RMU panel size 4 mtr x 2 Mtr including duct for HT cable in back side and Height 1 Mtr from ground level GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in copping, plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick, as in flour PCC 1:2:4 type B1 250mm thick floor using extra cement returning filling and removal on surplus soil, 3 coats of white washing on cement work for fixing RMU including Steps of complete all as specified and as directed.
6
-
-
... More
Excavation in trenches not exceeding 1.5 m wide and not exc. 1.5m deep and getting out in soft/ loose soil for laying of cable complete all as specified.
1897
-
-
... More
Excavation in trenches exceeding 1.5 m depth but not exceeding 3 mtr and 1.5 m wide and getting out in soft/ loose soil for laying of cable complete all as specified.
2.6
-
-
... More
Returing, filling in trenches including spreading, leveling, watering & well ramming in layers not exceeding 25 cm (soft/loose soil) complete all as specified & directed.
1355
-
-
... More
Removing excavated material n.exc. 50 m and depositing where directed as a level n.exc. 1.5 m above the starting points.
543
-
-
... More
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.
477.9
-
-
... More
Supplying & Laying un-reinforced pre cast concrete cable protection cover of class HVP type 2 with peak, size 450mm x 180mm x 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
15000
-
-
... More
Supplying & Laying un-reinforced pre cast concrete cable protection cover of Type 2, flat, size 300mm x 180mmx 40mm, factory made, complete all as specified and directed by the Engineer-in-Charge.
15000
-
-
... More
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping of poles including necessary form work complete all as specified and directed.
1
-
-
... More
M & L PCC (1:3:6) type C-1 (using 20 mm graded black trap/granite/basalt stone aggregate) for coping of the pole including necessary form work complete all as specified and directed.
5
-
-
... More
M & L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) for foundation of the pole complete all as specified and directed.
1
-
-
... More
Supply and laying Galvanised iron pipe light grade of dia 100mm for protection of cable
50
-
-
... More
Supply and laying Galvanised iron pipe light grade of dia 80mm for protection of cable
40
-
-
... More
Supply and laying Galvanised iron pipe light grade of dia 50mm for protection of cable
40
-
-
... More
Supply and laying Galvanised iron pipe light grade of dia 40mm for protection of cable
80
-
-
... More
M&L for boring under road with trench less technology for road crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by hydrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, for GI pipe light grade of size up to 100 mm dia lof in any lengthany grade including for housing LT/HT UG cables of size upto 95 Sqmm HT cable and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
Note: GI pipe shall be measured and paid separately
30
-
-
... More
Supply and fix Cable route Indicator made out of 150 mm round disc of cast iron duly written with HT/11 KV cable properly fixed with nut bolts to angle iron 40X40X5 mm length 60 cms properly grouted in PCC pillar with PCC 1:2:4 B1 using 20 mm graded stone in ground at a depth 25 cms with PCC 1:2:4 type B1 using 20 mm graded stone aggregate Size 10X10X10 cm under ground, the Angle iron shall be painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and directed. (excavation, returning filling and removal are included in the quoted rate)
50
-
-
... More
Supply, lay, connect test and commissioning of 3 core 120 Sqmm, 11000 Volts grade(Earthed) XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor laid in trench/under ground/wall/surafce/tunnel/duct complete all as directed by Engineer-in-Charge.
3000
-
-
... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 3 core XLPE armoured aluminium conductor cable of size 95 sqmm
21
-
-
... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 3 core XLPE armoured aluminium conductor cable of size 120 sqmm
20
-
-
... More
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of 3 core XLPE armoured aluminium conductor cable of size 120 sqmm
3
-
-
... More
Supply, laying and testing cable XLPE Insulated (Earthed),screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 400 sq mm 3½ core
100
-
-
... More
-do- as ser No 30, but of size 3.5 core 185 Sqmm
260
-
-
... More
-do- as ser No 30, but of size 3.5 core 70 Sqmm
340
-
-
... More
-do- as ser No 30 but of size 3.5 core 95 Sqmm
320
-
-
... More
-do- as ser No 30, but of size 3.5 core 35 Sqmm
880
-
-
... More
-do- as ser No 30 but of size 3.5 core 50 Sqmm
80
-
-
... More
-do- as ser No 30 but of size 4 core 16 Sqmm
1400
-
-
... More
Supply, install, commissioning and testing factory made( Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising )LT panel box (KIOSK) out door typesize not less then 2000 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (near mosque)
1
-
-
... More
Incomer (a) MCCB FP 630 A 36 kA with Electronic/Microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
(b) 4 Nos Aluminium Bus bars of Aluminium strips (50X12mm) having 800 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Outgoing :-
(c) MCCB FP 200A 21 kA with Adjustable Thermal release for over load 0.64 to 1.0 and Adjustable magnetic release (3.5 to 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04 Nos
(d) MCCB FP 160 A 21 kA with Adjustable Thermal release for over load 0.64 to 1.0 and Adjustable magnetic release (3.5 to 10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 Nos (e) MCCB FP 63 A 16 kA fixed type with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 Nos
Metering Compartment
(f) Digital type Amp meter 0-400 Amp(size 96mmx96mm) with Selector switch and 3 Nos CT of ratio 400A/5A-1No (g) Digital Type volt meter 0-500 V with selector switch -1Nos
(h) Digital Multifunction meter having for mearing KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos
(h) RYB LED incating lamp -3 Nos
Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item.
(ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly.
Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or deposited in MES Yard store. This will not measured as schedule Credit items
(iv) The canopy shall be exposed not less then 15cm both side
-
-
-
... More
Supply, install, commissioning and testing factory made ( Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) LT panel box (KIOSK) out door typesize not less then size 1500 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- 294, behind 271, behind 240)
3
-
-
... More
Incomer (a) MCCB FP 315 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
(b) 4 Nos Aluminium Bus bars of 500 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Outgoing :-
(c) MCCB FP 160 A 21 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -02 Nos(1 spare) (d) MCCB FP 100 A 21 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04Nos(1 spare)
Metering Compartment
(f) Digital type Amp meter 0-250 Amp(size 96mmx96mm) with Selector switch and 3 Nos CT of ratio 250 A/5A-1No (g) Digital Type volt meter 0-500 V with selector switch -1Nos
(h) Digital Multifunction meter having for mearing KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos
(i) RYB LED incating lamp -3 Nos
Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item.
(ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly.
(iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or deposited in MES Yard store. This will not measured as schedule Credit items
(v) The canopy shall be exposed not less then 15cm both side
-
-
-
... More
Supply, install, commissioning and testing factory made (Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) LT panel box (KIOSK) out door typesize not less then size 1500 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- near CSD)
1
-
-
... More
Incomer (a) MCCB FP 250 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
(b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Outgoing :-
(c) MCCB FP 160 A 35 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -02 Nos(1 spare)
(d) MCCB FP 100 A 16 kA with fixed Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -03 Nos(1 spare)
Metering Compartment
(f) Digital type Amp meter 0-250 Amp(size 96mmx96mm) with Selector switch and 3 Nos CT of ratio 250 A/5A-1No (g) Digital Type volt meter 0-500 V with selector switch -1Nos
(h) Digital Multifunction meter having for mearing KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos
(i) RYB LED incating lamp -3 Nos
Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item.
(ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly.
(iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or deposited in MES Yard store. This will not measured as schedule Credit items
(v) The canopy shall be exposed not less then 15cm both side
-
-
-
... More
Supply, install, commissioning and testing factory made (Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) LT panel box (KIOSK) out door typesize not less then size 1500 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- For SNCOS mess & SNCOS billet area)
2
-
-
... More
Supply, install, commissioning and testing factory made (Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) LT panel box (KIOSK) out door typesize not less then size 1500 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- For SNCOS mess & SNCOS billte area)
3
-
-
... More
(a) MCCB FP 250 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
(b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Outgoing :- (c) MCCB FP 100 A 16kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04 Nos(1 spare)
(d) RYB LED incating lamp -3 Nos
Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item.
(ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly.
(iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or deposited in MES Yard store. This will not measured as schedule Credit items
(v) The canopy shall be exposed not less then 15cm both side
-
-
-
... More
Supply installed testing and comminsioning , outdoor type,Self standing, double door, front and back openable, APFC panel fabricated ( Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) compartmental type with APFC relay 9 stage with heavy duty MPP capacitor bank 100 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+3x 10 KVAr + 3 x 20KVAr with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each capacitor control and MCCB TPN 160 Amp 16 KA as incomer including control CT & control wiring complete dust and vermin proof double door made out of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys having following assessories including control wiring with HR FRLS copper wire complete all as specified
3
-
-
... More
(i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry
(ii) Capacitor installed in removable assemblies for ease of operation and maintenance
(iii) Incoming of APFC panel of MCCB TPN 160 Amps, 16 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating.
(iv) 100 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+3x 10 KVAr + 3 x 20KVAr) with 7% detuned harmonics filter reactor. with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor.
(v) High performance microprocessor based 3 phase APFC relay 9 stage with Auto/Manual Option.
(vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No)
(vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors
(viii) Induced air system provided with axial flow fan/ centrifugal fan.
(ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front
(x) The canopy shall be exposed not less then 15cm both side
-
-
-
... More
Supply installed testing and comminsioning , outdoor type,Self standing, double door, front and back openable, APFC panel fabricated ( Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) compartmental type with APFC relay 9 stage with heavy duty MPP capacitor bank 50 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+2x 10 KVAr + 1 x 20KVAr with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each capacitor control and MCCB TPN 160 Amp 16 KA as incomer including control CT & control wiring complete dust and vermin proof double door made out of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys having following assessories including control wiring with HR FRLS copper wire complete all as specified (Location :- Qtr 210 and 214 of Item No 02)
3
-
-
... More
(i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry
(ii) Capacitor installed in removable assemblies for ease of operation and maintenance
(iii) Incoming of APFC panel of MCCB TPN 160 Amps, 16 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating.
(iv) 50 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+2x 10 KVAr + 1 x 20KVAr with 7% detuned harmonics filter reactor.with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor.
(v) High performance microprocessor based 3 phase APFC relay 9 stage with Auto/Manual Option.
(vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No)
(vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors
(viii) Induced air system provided with axial flow fan/ centrifugal fan.
(ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front
(x) The canopy shall be exposed not less then 15cm both side
-
-
-
... More
Supply installed testing and comminsioning , outdoor type,Self standing, double door, front and back openable, APFC panel fabricated ( Design verified as per IS/IEC-61439-1&2, by CPRI approved manufactures,along with FAT,floor mounted powder coated comprising ) compartmental type with APFC relay 9 stage with heavy duty MPP capacitor bank 40 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+1x 10 KVAr + 1 x 20KVAr with 7% detuned harmonics filter reactor. ) with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating currect of capacitor suitable for each capacitor control and MCCB TPN 160 Amp 16 KA as incomer including control CT & control wiring complete dust and vermin proof double door made out of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys having following assessories including control wiring with HR FRLS copper wire complete all as specified (Location :- Qtr 210 and 214 of Item No 02)
1
-
-
... More
(i) Compact modular bolted design, removable side and back panels with option of top and bottom cable entry
(ii) Capacitor installed in removable assemblies for ease of operation and maintenance
(iii) Incoming of APFC panel of MCCB TPN 160 Amps, 16 KA breaking capacity with high electrolytic grade Aluminium bus bar iof suitable rating.
(iv) 40 KVAR (1 KVAR + 2 x 2 KVAR + 1x 5 KVAr+1x 10 KVAr + 1 x 20KVAr with 7% detuned harmonics filter reactor.with thyrister control module and MCCB TP of 16 KA of 1.5 time of rating current of each capacitor suitable for each control . ( each capacitor bank equipped with discharge resister) & 7% detuned harmonics filter reactor.
(v) High performance microprocessor based 3 phase APFC relay 9 stage with Auto/Manual Option.
(vi) In built 3 phase power analyzer , Amp meter, volt meter and PF meter (each have 1 No)
(vii) Capacitor duty thyrister control modules with high thermal current carrying capacity and early make contacts to reduce inrush current for enhancing life of capacitors
(viii) Induced air system provided with axial flow fan/ centrifugal fan.
(ix) Bottom cable entry system available with front glass for viewing controller and analyzer from front
(x) The canopy shall be exposed not less then 15cm both side
-
-
-
... More
Disconnecting/dismantling and removing unserviceable time switch board of any description and S&F of automatic street light switch using Infrared Sensor based NATURE SWITCH for automatic switching of street lights. Nature switch operation switch operation should be based on Natural light Lux level. Required illuminance level for Switching ON is= 30 lux and for switching OFF=10 lux. The sensor should also have part night operation facility of min 4 hours to max 12 hours. The sensor along with suitable Power contactors, incoming-outgoing MCB's and Auto manual(Sensor By-pass) selection option should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, termite proof and FR grade IP66 protection class 2 Enclosure made of thermoplastic polycarbonate and protected against weather influences. For three phase load of 5KW(Swadeep02 EC dual series-5kW3P) with: 3 Nos contactors, 3 nos incoming MCB's & 3 nos outgoing MCB's of 20-25 Amps each and 1 No time switch & circuit wiring (copper)of min 10 sqmm.Make: Nature switch:Kakatiya Energy system/Bajaj/Healer, Contactors:BCH/L&t/SSchneider, MCB's: HAGER/Schneider/L&T(Exora/AU series)/C&S, Time switch : L&T, Schiender ABB
1
-
-
... More
Dismenting and taking out existing serviceable LED lights any capacity and refixed the same with providing new GI pipe breaket 1200mm long made out of 40 mm dia GI pipe including FI clamp 2 Nos complete
40
-
-
... More
S&F Junction box 290 x 200 x 130 mm Polycarbonate Hinged Enclosure box for cable in / out of street light LT cable, out door type, testing and commissioning with locking arrangements fixed on poles 4 pole 100 Amp Connector / terminal assambly with nut bolt and washer , including MCB SP 6A, 240 V, 10KA - 01 Nos for connecting suitable size of XLPE UG cable all as specified and directed.Make Hensal/ IDIS India/FINBOX
40
-
-
... More
S&F in repair Service wire 2 core 1 sqmm Copper wire in PVC conduit complete all as specified and directed by Engr -in- Charge.
280
-
-
... More
Supply, fixing, commissioning and testing of outdoor, gang operated switch (GOD), single throw single break off load type, of current rating upto 400 Amps, nine pole, each pole consisting of galvanized steel base, HT insulators as per IS, non ferrous knife and spring, loaded contacts, arcing horns of adequate section to break magnetizing current of the transformers, horizontal GI pipe of adequate length for phase separation, adequate length of GI pipes for operation from ground level and operating handle with locking arrangement complete in both OFF & ON positions. All ferrous parts hot dipped galvanized and non ferrous heavily tinned to withstand weather and suitable for vertical mounting with fuse unit carrier of 200 Amps rating and fuse element upto 50 Amps along with rod for expulsion fuses and 3 Nos post insulators for fuses including dismantling and taking down existing unserviceable GOD switch complete all as specified and as directed by Engineer-in-Charge. Make :- Jaipuria Brothers/ HEI/ ECE Calcutta/
7
-
-
... More
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized iron earth strip 32x6 mm as earthing lead by means of bolt ,nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earthwork, G.I.pipe light grade 40mm bore for protection of G.I.strip from earth electrode to incl the earth test point supplying and laying charcoal dust, common salt PCC 1:2:4 type CI chamber and MS angle iron frame 40x40x3mm RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm c/c both ways with MS handle 12 mm dia CI funnel and wire mesh, 20 mm dia GI pipe light graded for watering all as shown in drawing and connected to earth test point incl testing complete all as specified and directed .
Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra.
80
-
-
... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron
strip
30
-
-
... More
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP-55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper , welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete all as specified and directed by Engineer-in-Charge. Note :- Earth work, PCC in foundation and coping, cross arms, danger notice board and anti climbing device shall be measured and paid separately Pole shall be of Make : National Tubing Co. Kanpur /Bharat Conduits Steel Works Kanpur/ Electro Steel Kolkata/ Tata Iron & Steel Co. Kanpur/Advance Steel Tubes Ltd. Delhi.
8
-
-
... More
Supply & fixing cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
Dismantling insulators any type, any size
120
-
-
... More
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
4
-
-
... More
Dismantling of ACSR or AAC conductors
6.2
-
-
... More
Taking out existing LT/HT UG cable of size up to 95 sqmm complete
200
-
-
... More
Supply and fix Danger notice plate of 1.6 mm thick miled steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal RED colur and fixed with MS clamps bolts and nuts of approved size for HT 25x20 cm size
8
-
-
... More
Fixing only chain link fencing including line wires any mesh size and type of soil rails straining bolts etc.including provision of binding wire
300
-
-
... More
Supply and fixng only chain link fencing made out of MS galvanized Minimum 4mm dia GI opening size 2.5"(approx) all specified and directed
800
-
-
... More
S&F mild steel TMT bars 6 mm to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips.
100
-
-
... More
Excavating Post holes any type soil (or similar holes)each n exc 0.5 cum,getting out, returning filling,and ramming earth or broken rubble mixed with earth around,in layers not exceeding 25cm,watering,and removing surplus soil to a distance n exc 50m and making good surface
50
-
-
... More
S & F mild steel work such as in angle iron flat iron fillets hand rails half round or other steel section or core for wooden hand rail straight portion drilled and countersunk for baluster running bars for doors balusters running bars for doors baluster noising to steps including embeding in concreat an screwing etc,wind ties for roof including securing bolts post and struts in fencing including cutting tops to shape as directed drilling holes notching for wire including all necessary works.
848
-
-
... More
S & F screw bolt (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends each scerwed end to be fitted with washers and one hexagonal or square nut n exc 10cm ans n esc 15cm long.
20
-
-
... More
Supply and install split Air conditioning unit (White), inverter type with split units indoor/outdoor with insulated copper tubing, Copper condenser coil, precision cooling technology,dual rotor inverter technology, R32 / any other ecofreindly refrigerant, Brushless DC motor, 6-in-1 Convertible Cooling, auto clean, Magic Display ecofriendly refrigerent, copper wound rotary compressor complete with cordless remote control unit, Stand for outdoor unit and dust filter for batter indoor air quality 5 star rating not less then SEER 5 and of capacity 1.5TR as comrising of the following:- (a) 1.5 Ton capacity using Eco friendly refrigernt cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr-in-charge. Make : Hitachi/blue star/LG/Voltas (b) One No condensing unit of 1.5 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condensor with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr-in-charge. Note :- (i) Aditional length for copper tubing if required at site shall be supply and fix by the contractor without any extra cost. (ii) rate for filling of hole with white cement/POP included in item rate.
16
-
-
... More
Supply and install split Air conditioning unit (White), inverter type with split units indoor/outdoor with insulated copper tubing, Copper condenser coil, precision cooling technology,dual rotor inverter technology, R32 / any other ecofreindly refrigerant, Brushless DC motor, 6-in-1 Convertible Cooling, auto clean, Magic Display ecofriendly refrigerent, copper wound rotary compressor complete with cordless remote control unit, Stand for outdoor unit and dust filter for batter indoor air quality 5 star rating not less then SEER 5 and of capacity 2TR as comprising of the following:- (a) 2 Ton capacity using Eco friendly refrigernt cooling unit wall mounting type complete with remote control draining out arrangement manually adjustable cover for cool air from front with and inter connection with the condensing unit etc all as specified and directed by Engr-in-charge. Make : Hitachi/blue star/LG/Voltas (b) One No condensing unit of 2 ton capacity comprising of all fitting such as single phase electric driven compressor, condensing fan motor, condensor with fixing of stand on wall and all necessary controls and accessories all as specified and directed by Engr-in-charge. Note :- (i) Aditional length for copper tubing if required at site shall be supply and fix by the contractor without any extra cost. (ii) rate for filling of hole with white cement/POP included in item rate.
17
-
-
... More
Supply and install water cooler of storage capacity 80 Ltrs, cooling capacity 20Ltr/Hr, 240V, 50Hz, single phase, 5 star rated, reciprocating oil cooled compressor, Copper condenser coil and copper wound compressor, (rate including voltage stabilizer of suitable capacity) colour as approved by Engr-in Charge and all as specified and as directed. Make: Blue Star, SDLX series or equivalent in Voltas.
10
-
-
... More
Supply, fixing and fabrication and testing desert cooler in GI body sheet with and including cooler fan motor size/sweep 450mm (fan blade only) 230 Volts, Single phase 50 Hz, 1400 RPM, having nominal air flow capacity of 5000 CuM per hour (or nearest size) heavy duty single sheet, totally enclosed. The overall dimesnions of the desert cooler shall not be less than 690mmx690mm x 1020mm with and including following accessories each. (a) Air grill of suitable size made out of 0.5mm PGI sheet including GSS arrangement with a knob for easy and smooth movement.
(b) Front & Side panel made out of 1mm thick PGI sheet of suitable size and shape.
(c) Water tank height shold not less than 11 inch made out of 2mm thk PGI sheet.
(d) Submersible pump electric driven single phase 230 volts, 50 Hz of suitable discharge and head but motor capacity not less than 18 watt. Make : Khaitan/Crompton or equivalent make.
(e) Service cord of 3 Core copper wire 1.5 Sqmm with plug top 5 Amp length not less than 2 metres.
(f) Electronic fan dimmer 1000 watts AC 230 Volt for controlling the fan speed.
(g) Complete electric wiring of desert coolers as required to operate fan and pump along with 5 Amp switches .
(h) Make of cooler fan motor: Khaitan/ Havells/Crompton Greaves/Marathon/Almonard
(j) Make of PGI sheet. Tata/Jindal/National
(k) Make of PGI sheet. Tata/Jindal/National
100
-
-
... More
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator(Remote controlled) and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) Compplete
348
-
-
... More
NOTE: Amount of credit of Rs. 97600.00 for retrieved materials is mentioned in schedule of credit on Srl Page No. 29 of tender documents in pdf form which will be deducted offline while acceptance of tender.
-
-
-