Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Security and Emergency Services
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Nov 2024
Closing Soon28 Nov 2024
Tender Amount₹ 49,48,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for filling approved dry river sand for cushioning and cover for protection of under ground electric cable in trenches 8 cm before laying cable and 15 cm deep over the cable and punning to 18 cm total thickness complete all as specified and as directed. Notes :- (i) Approved dry sand free from vegetations, grass and other deleterious substances shall be used. (ii) For the purpose of payment, only punned thickness shall be measured.

93

-

-

... More
Taking down carefully old existing LT PCC Cable Cover of Class LV of any type & size complete all as specified & as directed.

6200

-

-

... More
Laying only LT PCC cable covers of any type & size for protection of UG LT electric cables in trenches, obtained serviceable from serial item No. 5 here-in-above, complete all as specified & as directed.

350

-

-

... More
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type-1, Flat, size 250mm x 150mm x 40mm for protection of underground electric cable in trenches complete all as specified and as directed.

7350

-

-

... More
M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.

16

-

-

... More
M&L for Galvanized iron tubing, 80mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.

12

-

-

... More
M&L for Galvanized iron tubing, 50mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of HT/LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.

12

-

-

... More
M&L for cutting of existing PCC floor / hardstanding / Interlocking tiles path / WBM road with soling & premix carpet of any description for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 90cm and width 45cm and filling the trench of road i.e. excluding top 20cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 20 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed including re-setting of interlocking tiles/ Paver block (where required) complete all as directed.

40

-

-

... More
M&L for PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.

6

-

-

... More
M&L for reinforced cement concrete 1:2:4 type B1 (using 20 mm graded crushed stone aggregate) as in foundation including rafts, footings, foundation beams, plinth beams, base of columns etc., basement slabs, under-reamed piles and mass concrete including necessary formwork complete all as specified and as directed. Note: Reinforcement shall be measured and paid for separately.

15

-

-

... More
M&L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.

400

-

-

... More
M&L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.

230

-

-

... More
M&L in repair for street light bracket made from MS tubing in required size & shape at site, cut to length, bend to shape required and suitable for existing street light pole and fixing the bracket to pole with MS flat and nuts and bolts and finally painting the exposed steel surface with two coats of first quality synthetic enamel paint of approved tint over a coat of zinc chromate primer complete all as directed. Notes :- (i) Size, section and shape of MS pipe shall be as directed. (ii) Quoted rate shall deemed to be inclusive of painting. Weight of paint shall not be considered for payment purpose and quoted rate shall deemed to be included this aspect.

180

-

-

... More
Supply, erection, commissioning & testing 16 metre High Mast suitable for 6 lantern symmetrically fitted along with their control gear, hot dip galvanized, fabricated from high tensile steel plates and suitable for wind velocity as per IS 875 (Part III) 1987 with door opening, raising and lowering system, head arrangement, two point suspension system with stainless steel wire ropes, double drum winch, integral power tool, torque limiter, lantern carriage, junction box, lightening finial, earth terminals, base flange, foundation bolts, pully assembly, lightning arrester spike, trailing cables, plug & socket, template, other standard accessories, etc including RCC foundation as per manufacturer’s instructions including necessary excavation & earthwork in any type of soil, complete all as specified & as directed.

4

-

-

... More
Supply, installing, commissioning and testing factory made and tested (CPRI approved manufacturer) new outdoor type LT Timer Switch Panel Box cubical type of suitable size (minimum depth 400mm) to accommodate the following accessories, 415 Volt, 3 Phase & neutral, 4 wire, 50 Hz, AC supply system, made out of 3.15 mm thick MS CRCA sheet (outer body, doors, etc), inside partitions & cover made out of 2mm thick MS CRCA sheet, with modular hinges, powder coated inside & outside with 7 tanks process in approved shade, protection class IP-66 with coloured insulation sleeve, rubber gasket, insulators, outdoor type, totally enclosed, weather, dust and vermin proof as per IS, Front & Rear opening with double door shutters having suitable aldrop bolt locking arrangement, with insulators, including internal wiring with PVC insulated stranded copper conductor FRLS cables of appropriate size as directed with proper ferrule & cable glands including connecting incoming and outgoing cables, including danger notice plate, necessary PCC 1:3:6 type C1 in foundation and frame made out of 65 x 65 x 6mm angle iron grouted at minimum 45cm above ground level and 30cm below ground level, comprising & including the following accessories complete all as specified and as directed :- (a) MCCB 63 Amp, 4 Pole, 25 kA, 415 Volt grade, AC, 50 Hz, adjustable Thermal - Magnetic release type - 01 No. as incoming. description of item contd....

4

-

-

... More
Description of serial item No. 18 contd… (b) MCB TPN 25 Amp, 10 kA, ‘C’ Curve, 415 Volt grade, AC, 50 Hz - 02 Nos as outgoing. (c) Astro digital time switch, 1 output, 16 A - 250 VA, 50/60 Hz, Astronomical function, 56 Programmes, 1 Channel, 2 Module - 01 No. Make: Legrand Cat Part No. 4126 54 or equivalent in makes mentioned in Appendix 'B' here-in-after. (d) Contactor CTX3 TP, 50A, 230V - Integrated Auxiliary Contacts 2NO+2NC, screw terminals - 01 No. Make: Legrand Cat Part No. 4161 46 or equivalent in makes mentioned in Appendix 'B' here-in-after. (e) Selector Switch for Manual/ Auto Mode - 01 No. (f) Phase Indicator coloured lamp Set RYB, “LED” type (set of three) -01 Set (g) Multifunction Meter - 01 No. Make: L&T/ C&S/ Legrand/ SECURE or equivalent in makes mentioned in Appendix 'B' here-in-after. (h) Bus bar minimum 100 Amp aluminium with R/Y/B coloured for three Phases and 50 Amp for Neutral Black colour insulation sleeves - 01 Set description of item contd....

-

-

-

... More
Description of serial item No. 18 contd… Notes : (i) Vertical height of legs of LT panel base frame shall be not less than 45 cm from top of nearest road level / PCC floor finish. Legs shall be grouted in ground minimum 30cm in PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate). (ii) The contractor shall produce and get the detailed (GD) drawings of LT Panel approved from GE through Engineer-in-Charge before fabrication and placing the order to the approved manufacturer. (iii) MS frame work shall be painted with two coats of synthetic enamel paint of approved tint over a coat of red oxide primer. (iv) Cost of internal wiring, MS frame work, painting, platform, MCCB spreaders, cable glands, locking arrangement with aldrop bolt and any minor addition/alteration where required at site (the decision of GE shall be final and binding regarding extent to which the change can be considered as minor addition/alteration) shall be deemed to be included in the quoted rates.

-

-

-

... More
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 Amp, 240 V, 10 kA, 'C' Curve (1 No.) & Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-6030 (BOPH-6030) or equivalent in makes mentioned in Appendix 'B' here-in-after. Note: Earth work and PCC foundation shall be measured & paid for separately.

40

-

-

... More
Dismantling and taking down existing damaged/broken PCC Pole and S&F new 3 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of dimensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate dimensions 200x200x12 mm, foundation bolt size 4 Nos x 16 mm dia, pitch circle dia 200 mm, bolt length 450 mm, projected bolt length 80 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with & including MCB SP 6 A, 240 V, 10 kA, 'C' Curve (1 No.), Connector (RYB&N) - 63 A Cap (01 No.) complete all as specified and as directed. Make of Pole: Bajaj Cat No. BOP-3030 or equivalent in makes mentioned in Appendix 'B' here-in-after. Note: Earth work and PCC foundation shall be measured & paid for separately.

18

-

-

... More
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed.

40

-

-

... More
Taking down existing street light fitting of any description and S&F new 90 Watt LED street light fitting, High Efficiency, minimum IP 65 protection, CCT - 5500K, powder coated pressure die spun aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED, Beam Angle (Throw & Spread) - 52"x24" and metal clad PCB, the minimum lumen output of the system should be greater than 9000 lumens with minimum lumens per watt 115±10% asymmetric fixing to existing bracket including nut bolts, connected with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and electrically connected to the existing system and testing on completion complete all as directed. Make: Bajaj Cat No. BCG BOR 90W LED CL TM CR or equivalent in makes mentioned in Appendix 'B' here-in-after.

2

-

-

... More
Taking down existing post top lantern of any description and S&F new 45W, IP 65 decorative outdoor post top lighting fixture with powder coated pressure die cast aluminium housing and translucent diffuser. The fitting shall have LED with Lens and PCB. The minimum lumen output of the system should be greater than 4000 lumens. The fittings shall have minimum surge protection 5 kV and fitting shall be sealed with a non-ageing silicone gasket, fixed as per manufacturer’s instructions and making necessary electrical connections with & including 2.5 sqmm, 3 core PVC insulated sheathed copper conductor cable from Junction Box to light fitting and testing on completion complete all as directed. Make : Bajaj 'BGCTN 45W LED WW' or equivalent in makes mentioned in Appendix 'B' here-in-after.

6

-

-

... More
Taking down existing Gate/ Post top light fitting and S&F new 28W LED Gate/Post Top lighting fixture, IP-65 protection, outdoor type, decorative, energy saving, environmental friendly, long life aesthetically designed with Die cast aluminium housing, Heat resistant toughened bell shaped acrylic diffuser, MS housing with PU paint, Top canopy made of spun aluminium, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, complete all as directed. Make : Jaquar Model 'Avior' Cat No. ‘FLPTAVOCD028 WWT0 LED POST TOP’ or equivalent in makes mentioned in Appendix 'B' here-in-after.

8

-

-

... More
Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 150 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed. Notes :- (i) Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of Flood light on structure/ building upto 18 metre height and quoted rate shall deemed to be included of this aspect. (ii) Cable/wire from Flood Light to feeder/junction box shall be measured & paid for separately under relevant item of this Schedule.

6

-

-

... More
Taking down existing flood light fitting of any description and Supply, installation, commissioning & testing 200 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed. Notes :- (i) Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of Flood light on structure/ building upto 18 metre height and quoted rate shall deemed to be included of this aspect. (ii) Cable/wire from Flood Light to feeder/junction box shall be measured & paid for separately under relevant item of this Schedule.

5

-

-

... More
Supply, installation, commissioning & testing 400 Watt LED Flood Light fitting, Luminaire Efficacy ≥ 110 lm/W, Correlated Colour Temperature (CCT) 5665K ± 355K, Colour Rendering Index (CRI) shall not be less than 70, fitting shall be designed for a system life of 50,000 hours @ 70% lumen maintenance, suitable for ambient temperature from (-)10°C to 50°C, Ingress protection of IP-66 (minimum), mechanical impact resistance rating of IK ≥ 07, operating voltage range 140 V to 270 V, AC, 50 Hz, Power factor ≥ 0.95, Total Harmonic Distortion (THD) ≤ 10%, Built-in Surge Protection not less than 4 KV, External Surge Protection not less than 10 KV, double phase protection, no load, open circuit and short circuit protection, powder coated pressure die cast aluminium housing, PMMA/polycarbonate/toughened glass heat resistant cover, prewired and connecting, complete all as specified and as directed. Notes :- (i) Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of Flood light on 16 metre high mast and quoted rate shall deemed to be included of this aspect. (ii) Cable/wire from Flood Light to feeder/junction box shall be measured & paid for separately under relevant item of this Schedule.

24

-

-

... More
S&F Aviation obstruction Red LED light 8.5 watt, 230 volts, IP 65, 50 Hz, fixing on top of the High Mast of height upto 18 mtr including necessary electrical connection and foundation complete all as specified & as directed. Note : Contractor shall make his own arrangements of T&P, ladder and all other items required for fixing of aviation light on top of High Mast and quoted rate shall deemed to be included of this aspect.

4

-

-

... More
S&F in repair Junction Box made from FRP sheet 2.00 mm thick readymade of size 400mm x 300mm x 200mm, aluminium busbar 100 Amp, 4 wire system, 415 Volt fixed to pole/ Wall with MS clamp of FI 25 x 5mm and suitable size of nut, bolts and washers complete all as specified & as directed.

7

-

-

... More
S&F 4.00 Sqmm 3 core PVC insulated, PVC Sheathed, multistranded copper conductor flexible cable of 1100 Volt grade (ISI marked) drawn through pole/ pipe from Flood Light to feeder/junction box etc with suitable lugs etc complete all as specified & as directed.

440

-

-

... More
S&F in repairs 2.50 Sqmm 3 core PVC insulated, PVC Sheathed, multistranded copper conductor flexible cable of 1100 Volt grade (ISI marked) drawn through existing conduit pipe/ inside GI Pole from junction box to fitting with suitable lugs etc complete all as specified & as directed.

300

-

-

... More
S&F 1.50 Sqmm 3 core PVC insulated, PVC Sheathed, multistranded copper conductor flexible cable of 1100 Volt grade (ISI marked) drawn through pole/ pipe from junction box to fitting with suitable lugs etc complete all as specified & as directed.

100

-

-

... More
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.

235

-

-

... More
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 16 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.

40

-

-

... More
Supply, laying, jointing and testing LT XLPE (cross linked polyethylene) insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric cable (heavy duty) with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 4 Core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including dismantling & taking out old unserviceable cable complete all as specified & as directed. Note : Sand cushioning, cable protection covers, protection pipe, jointing kits and excavation & earth work shall be measured & paid for separately.

1030

-

-

... More
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.

5

-

-

... More
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized mild steel strip 25x4 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted/welded to earth plate at one end and other end of strip connected to Panel / transformer / GOD / equipment body / test point with two Nos nuts bolts or welding with steel structure, GI earth strip encased in and including 40mm bore GI light grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed.

12

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.