Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Oct 2024
Closing Date23 Oct 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for in repair for rewinding of 70/75 HP, 3 Phase capacity induction motor by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size / turns, varnishing with class 'B' insulation, balancing of shaft, including replacement of UNSV connection plate / terminal point as per site requirement. assembling the motor including transportation, testing as per the specified RPM at workshop complete all as specified and as directed.

1

-

-

... More
All as per item No.4 above but of capcity 60 HP, 3 Phase

3

-

-

... More
All as per item No.4 above but of capcity 15HP to 20 HP, 3 Phase

2

-

-

... More
M & L for repair and overhauling of 70/75 HP, 3 Phase capacity centrifugal pump set of any make, dismantling and taking down pump after disconnecting water supply connections, decoupling from motor removing out impeller, cleaning, descaling, greasing to bearings and replacement of unserviceable parts such as bearings, pump shaft sleeves, coupling puny, pump shaft etc. Assembly in the pump with new packing materials, nuts, bolts and washers, gland bolt & packing, coupling bushes, coupling bolts and coupling with motor checking for vibration and alignment connecting delivery and suction pipe, testing the pump sets complete all as specified and directed. Note: Spare parts shall be measured and paid separately.

2

-

-

... More
All as per item No.7 above but of capcity 60 HP, 3 Phase

8

-

-

... More
All as per item No.7 above but of capcity 15HP to 20 HP, 3 Phase

4

-

-

... More
S & F in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt, 75/70 HP complete all as specified and directed.

-

-

-

... More
Motor bearing. Make : SKF/NBC/TATA/FAG/ UBC.

2

-

-

... More
Motor cooling fan

2

-

-

... More
Pump motor Pin bush coupling of size RB 198/10 with nut bolts, washer

2

-

-

... More
L-225/190 spider

2

-

-

... More
Cover bolts & washers

2

-

-

... More
Pump bearing with housing. ‘O' ring. Make: SKF/UBC/TATA/FAG/ NBC

2

-

-

... More
CI impeller as per existing model complete

1

-

-

... More
Gland packing

4

-

-

... More
SS Sleeve (Gland Sleeve)

2

-

-

... More
Pump shaft with studs and nuts for pump body.

1

-

-

... More
Shaft seal of existing size

2

-

-

... More
S & F in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 60 HP complete all as specified and directed.

-

-

-

... More
Motor bearing. Make : SKF/NBC/TATA/FAG/ UBC.

4

-

-

... More
Motor cooling fan

4

-

-

... More
L-225/190 spider

5

-

-

... More
Pump motor Pin bush coupling of size RB 198/10 with nut bolts, washer

4

-

-

... More
Cover bolts & washers

4

-

-

... More
Pump bearing with housing. ‘O' ring. Make: SKF/UBC/TATA/FAG/ NBC

4

-

-

... More
CI impeller as per existing model complete

2

-

-

... More
Gland packing

10

-

-

... More
SS Sleeve (Gland Sleeve)

5

-

-

... More
Pump shaft with studs and nuts for pump body.

1

-

-

... More
Shaft seal of existing size

2

-

-

... More
S & F in repair following parts for existing centrifugal pump set electric driven 3 phase 415 volt 15 to 20 HP complete all as specified and directed.

-

-

-

... More
Motor bearing. Make : SKF/NBC/TATA/FAG/ UBC.

2

-

-

... More
Motor cooling fan

2

-

-

... More
Cover bolts & washers

2

-

-

... More
CI impeller as per existing model complete

2

-

-

... More
Pump shaft with studs and nuts for pump body.

1

-

-

... More
Shaft seal of existing size

2

-

-

... More
M & L for repair & overhauling of 5 to 7.5 HP, 3 Phase mono-block pump set, taking out impeller, cleaning, descaling & greasing to bearings including replacement of unserviceable parts such as bearings, gland flange, etc. Cleaning and varnishing the starter and rotar, winding, heating and drying replacement of burnt terminals of motor assembling in the pump with new packing materials nuts, bolts, washers checking alignment connecting all electrical/water connections, checking the vibrations & alignment, RPM,DOR, testing the pump sets of on full load complete all as specified and directed. Note:- (i) Cost of small U/S parts such as new packing materials, nuts, bolts & washers, gland bolt & packing, coupling bushes, coupling bolts shall deemed to be inclusive in quoted rate. (ii) Major unserviceable spares as listed below shall be measured and paid separately.

5

-

-

... More
All as per item No.13 above but of capcity 2 to 3 HP, 3 Phase

8

-

-

... More
All as per item No.13 above but of capacity 1 to 3 HP, 1 Phase

5

-

-

... More
Supply only greasing for bearing of centrifugal Pumps all as specified and as directed.

50

-

-

... More
M & L for in repairs for rewinding of 5 to 7.5 HP, 3 Phase capacity monoblock pump set by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new copper wire of existing gauge and size / turns, varnishing with class 'B' insulation, balancing of shaft, Intl replacement of UNSV connection plate / terminal point as per site requirement, assembling the motor including transporation, testing as per the specified RPM at workshop complete all as specified and as directed.

2

-

-

... More
All as per item No.17 above but of capcity 2 to 3 HP, 3 Phase

4

-

-

... More
All as per item No.17 above but of capacity 1 to 3 HP, 1 Phase

3

-

-

... More
S & F in repair following parts for existing monoblock pump set electric driven 3 phase 415 volt 5 to 7.5 HP complete all as specified and directed.

-

-

-

... More
Motor bearing with housing. Make : SKF/NBC/TATA/FAG/ UBC.

3

-

-

... More
Motor cooling fan

2

-

-

... More
Cover bolts & washers

2

-

-

... More
CI impeller as per existing model complete

2

-

-

... More
Gland packing

6

-

-

... More
SS Sleeve (Gland Sleeve)

4

-

-

... More
Pump shaft with studs and nuts for pump body.

1

-

-

... More
Shaft seal of existing size

4

-

-

... More
S & F in repair following parts for existing monoblock pump set electric driven 3 phase 415 volt 2 to 3 HP complete all as specified and directed.

-

-

-

... More
Motor bearing with housing. Make : SKF/NBC/TATA/FAG/ UBC.

6

-

-

... More
Motor cooling fan

2

-

-

... More
Cover bolts & washers

3

-

-

... More
CI impeller as per existing model complete

4

-

-

... More
Gland packing

8

-

-

... More
SS Sleeve (Gland Sleeve)

6

-

-

... More
Pump shaft with studs and nuts for pump body.

3

-

-

... More
Shaft seal of existing size

2

-

-

... More
S & F in repair following parts of existing monoblock pump set electric driven 1 phase 230 volt 1 to 3 HP complete all as specified and directed.

-

-

-

... More
Motor bearing with housing . Make : SKF/NBC/TATA/FAG/ UBC.

3

-

-

... More
Motor cooling fan

2

-

-

... More
Capacitor of capacity 40 to 100 MFD

4

-

-

... More
Capacitor of capacity 120 to 250 MFD

4

-

-

... More
Cover bolts & washers

2

-

-

... More
CI impellar as per existing model complete

3

-

-

... More
Centrifugal Clutch as per existing model

5

-

-

... More
Pump shaft with studs and nuts for pump body.

2

-

-

... More
M & L for lifting of submersible pump set of 30 HP to 40 HP capacity for repair and overhauling, carefully from bore well along with existing submersible cable, MS/GI/HDPE Column pipe of 80mm to 140mm dia, flanged type, 3 meters each length (depth of submersible pump is from 80 to 120 m) and shifting of column pipe, pump set and disconnecting of submersible cable aside for reuse and lowering into bore well after carrying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing. binding of submersible cable with column pipe by using aluminium wire, jointing of nylon rope et complete and testing complete all as specified and as directed. Note:- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc. (ii) Any damage to pump set column pipe submersible cable etc while lifting and lowering of pump set shall be repaired / replaced by contractor on his own cost and GE's decision shall be final and binding in this regard.

12

-

-

... More
All as per item No.23 above but of capacity 7.5 HP to 15 HP, 3 Phase

3

-

-

... More
M & L for complete opening of submersible bore well pump motor set of 30 HP to 40 HP capacity for repair / replacement of unserviceable worn out bearing / worn out unserviceable shaft / burned out copper winding as per existing gauge, No of turns, varnishing with specified RPM / worn out strainer / bush / sleeve / thrust pad / thrust bearing / thrust bearing lock nut etc, including re-assembling and testing as per specified RPM at workshop etc complete all as specified and as directed. Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs. (ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding work if any required as per site requirement, balancing of starter, repairing starter stamping, water cap, SS nut, bolts, washers etc complete. (iii) The quoted shall be inclusive of shaft rubber seal etc complete (iv) Winding shall be measured and paid separately. (v) Spares replaced shall be measured and paid separately under relevant item.

10

-

-

... More
All as per item No.25 above but of capcity 7.5 to 15 HP, 3 Phase

4

-

-

... More
M & L for rewinding the submersible motor of 30 HP to 40 HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete all as specified and as directed.

6

-

-

... More
All as per item No.27 above but of capacity 7.5 to 15 HP, 3 Phase

2

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 30 to 40 HP complete all as specified and directed

-

-

-

... More
Thrust bearing including bush

6

-

-

... More
Revolving Disc

6

-

-

... More
SS Connection piece

6

-

-

... More
CI upper housing

5

-

-

... More
CI lower housing

5

-

-

... More
CI Motor Base

6

-

-

... More
Thrust plate

5

-

-

... More
CI Suction chamber

5

-

-

... More
CI stage bowl

5

-

-

... More
GM bush for pump

24

-

-

... More
SS Impeller

20

-

-

... More
Cl DOL Piece

4

-

-

... More
Bearing housing

15

-

-

... More
Sand guard/cover

4

-

-

... More
Pump shaft sleeve of SS

15

-

-

... More
PVC Neck Ring of existing model

42

-

-

... More
T Bolts of existing size and model

24

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt, 7.5 HP to 15 HP complete all as specified and directed.

-

-

-

... More
Thrust bearing including bush

2

-

-

... More
Revolving Disc

1

-

-

... More
SS Connection piece

2

-

-

... More
CI upper housing

1

-

-

... More
CI lower housing

1

-

-

... More
CI Motor Base

1

-

-

... More
Thrust plate

2

-

-

... More
CI Suction chamber

1

-

-

... More
CI stage bowl

1

-

-

... More
GM bush for pump

4

-

-

... More
SS Impeller

4

-

-

... More
Cl DOL Piece

1

-

-

... More
Bearing housing

3

-

-

... More
Sand guard/cover

1

-

-

... More
Pump shaft sleeve of SS

3

-

-

... More
PVC Neck Ring of existing model

15

-

-

... More
T Bolts of existing size and model

10

-

-

... More
M & L for Lifting of submersible pump set of 40HP to 50 HP capacity carefully from open well/UG Sump/SWT alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of submersible cable aside for reuse and lowering into well/sump/SWT after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified and as directed. Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc. (ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE's decision shall be final and binding in this regard.

4

-

-

... More
All as per item No.31 above but of capcity 20 to 30 HP

8

-

-

... More
All as per item No.31 above but of capcity 10 to 15 HP

4

-

-

... More
All as per item No.31 above but of capcity 5 to 7.5 HP

10

-

-

... More
All as per item No.31 above but of capcity 2 to 3 HP

5

-

-

... More
M & L for complete opening of horizontal submersible motor 40 HP to 50 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed. Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs. (ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of pump seal, replacement of wornout nut, bolts, washers etc complete. (iii)Winding shall be measured and paid separately.

2

-

-

... More
All as per item No.36 above but of capcity 20 to 30 HP

4

-

-

... More
All as per item No.36 above but of capcity 10 to 15 HP

3

-

-

... More
All as per item No.36 above but of capcity 5 to 7.5 HP

5

-

-

... More
All as per item No.36 above but of capcity 2 to 3 HP

3

-

-

... More
M & L for rewinding the submersible motor of 40HP to 50 HP capacity by means of cutting and removing I existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete all as specified and as directed.

2

-

-

... More
All as per item No.41 above but of capcity 20 to 30 HP

4

-

-

... More
All as per item No.41 above but of capaity 10 to 15 HP

3

-

-

... More
All as per item No.41 above but of capaity 5 to 7.5 HP

5

-

-

... More
All as per item No.41 above but of capaity 2 to 3 HP

3

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt, 40 HP to 50 HP complete all as specified and directed.

-

-

-

... More
Pump bearing. Make : SKF/NBC/TATA/FAG/ UBC.

3

-

-

... More
Pump bush

3

-

-

... More
SS Sleeve

3

-

-

... More
CI impeller as per existing model complete

1

-

-

... More
Pump shaft

1

-

-

... More
Shaft seal of existing size

4

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt, 20 HP to 30 HP complete all as specified and directed.

-

-

-

... More
Pump bearing. Make : SKF/NBC/TATA/FAG/ UBC.

4

-

-

... More
Pump bush

4

-

-

... More
SS Sleeve

4

-

-

... More
CI impeller as per existing model complete

2

-

-

... More
Pump shaft

2

-

-

... More
Shaft seal of existing size

4

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt, 10 HP to 15 HP complete all as specified and directed.

-

-

-

... More
Pump bearing. Make : SKF/NBC/TATA/FAG/ UBC.

5

-

-

... More
Pump bush

4

-

-

... More
SS Sleeve

4

-

-

... More
CI impeller as per existing model complete

2

-

-

... More
Pump shaft

2

-

-

... More
Shaft seal of existing size

5

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt, 5 HP to 7.5 HP complete all as specified and directed.

-

-

-

... More
Pump bearing. Make : SKF/NBC/TATA/FAG/ UBC.

3

-

-

... More
Pump bush

3

-

-

... More
SS Sleeve

2

-

-

... More
CI impeller as per existing model complete

2

-

-

... More
Pump shaft

1

-

-

... More
Shaft seal of existing size

4

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt, 2 HP to 3 HP complete all as specified and directed.

-

-

-

... More
Pump bearing. Make : SKF/NBC/TATA/FAG/ UBC.

2

-

-

... More
Pump bush

2

-

-

... More
SS Sleeve

2

-

-

... More
CI impeller as per existing model complete

1

-

-

... More
Pump shaft

1

-

-

... More
Shaft seal of existing size

3

-

-

... More
M & L for Lifting of non-clog pump set of 10 HP to 15 HP capacity carefully from sewage well alongwith existing submersible cable, MS/GI/HDPE Column pipe of any dia and shifting of column pipe, pumpset and disconnecting of cable aside for reuse and lowering into well after carying out necessary repair work including jointing of submersible cable with water proof jointing kit, testing, binding of submersible cable with column pipe by using aluminium wire complete and testing complete all as specified and as directed. Note :- (i) The quoted rate deemed to be included the cost of replacement of rubber gaskets, nuts, bolts, washers aluminium wire etc. (ii) Any damage to pump set pipe submersible cable etc while taking out and lowering of pump set will be repaired/replaced by contractor on his own cost and GE's decision shall be final and binding in this regard.

4

-

-

... More
All as per item Ser No 51 above but of capcity 3 to 5 HP

4

-

-

... More
M&L for complete opening of non-clog pump motor 10 HP to 15 HP for repair /replacement of unserviceable worn out bearing/worn out unserviceable shaft/burned out copper winding /worn out strainer/bush/sleeve/thrust pad/thrust bearing/thrust bearing lock nut etc including transportation complete all as specified and as directed. Note :- (i) The quoted shall be inclusive of transportation of pump set from pump house site to workshop and back to pump house site after necessary repairs. (ii) The quoted shall be inclusive of balancing of shaft through lathe work incl welding wk if any required as per requirement, replacement of wornout nut, bolts, washers etc complete. (iii) Winding shall be measured and paid separately.

2

-

-

... More
All as per item Ser No 53 above but of capcity 3 to 5 HP

2

-

-

... More
M&L for rewinding the non-clog motor of 10HP to 15 HP capacity by means of cutting and removing existing burnt out winding completely cleaning and repair of slots and rewinding with new PVC insulated copper wire of existing gauge and size / turns, balancing of shaft, testing as per the specified RPM at workshop complete including replacement winding oil and oil seal all as specified and as directed.

2

-

-

... More
All as per item Ser No 55 above but of capcity 3 to 5 HP

2

-

-

... More
S & F in repair following parts for existing nonclog pump set electric driven 3 phase 415 volt 10 HP to 15 HP complete all as specified and directed.

-

-

-

... More
Pump bearing Make : SKF/NBC/TATA/FAG/ UBC.

2

-

-

... More
Pump bush

2

-

-

... More
SS sleeve

2

-

-

... More
CI impellar as per existing model

1

-

-

... More
Pump shaft

1

-

-

... More
Shaft seal of existing size

4

-

-

... More
S & F in repair following parts for existing submersible pump set electric driven 3 phase 415 volt 3 HP to 5 HP complete all as specified and directed.

-

-

-

... More
Pump bearing Make : SKF/NBC/TATA/FAG/ UBC.

2

-

-

... More
Pump bush

2

-

-

... More
SS sleeve

2

-

-

... More
CI impellar as per existing model

1

-

-

... More
Pump shaft

1

-

-

... More
Shaft seal of existing size

3

-

-

... More
Supply, Installation testing and commissioning in repairs of Factory made LT panel board indoor type, dust & Vermin proof fabricated out of 2.00 mm thick CRCA sheet fixed with Angle iron frame of size 40x40x5mm duly powder coated complete using lugs,and glands of cable connection and having epoxy coated 400 Amps copper bus bar 4 strips for 3 phase and neutral 415 Volts, 50Hz mounted on epoxy insulators, prewired with suitable size of PVC insulated multi strand copper conductor cable having independent enclosure for incoming and outgoing electrical connection and cable gland at bottom for incoming and outgoing and locking arrangement on front side and taking down existing LT panel, all as directed by Engineer in Charge including following fittings and fixtures. Note:- (i) Panel shall be fixed on base made out of PCC (1:2:4) type B1, size of the base shall be as per manufacturer instructions. Cost of the base shall deemed to be included in the unit rate of this item. Loc: Site Pump House Incoming:- (a) On load change over switch 250 Amps capacity, ISI marked three phase and neutral. (b) MCCB 250 Amp, Four pole, 415 Volts, 50 HZ, Adjustable type -01 No. Outgoing:- (a) MCCB 100 Amps, Four Pole, 415 Volts, 50 Hz- 03 Nos (b) Star delta Motor starter fully automatic suitable for 40 HP motor, Thermal overload relay incudling Contactor and timer etc.suitable for induction motor with single phase protection relay, Auto phase sequence corrector, Low and high voltage correction and time delay 4- to 7 second, start and stop push buttons etc complete - 03 Nos. (c) Digital Volt meter with selector switch -01 Nos (d) Digital Ampere meter 3 Phase, 96x96 Sqmm with PT with selector switch - 01 Nos (e) Indicator lamp LED type of (R.Y,B) set of three - 01. No.

1

-

-

... More
All as per item No.59 above but with 150 Amp copper bus bar comprising following:- Location Swimming Pool Incoming:- (a) MCCB 125 Amp, 4 pole, 415 V, 50 HZ 35 KA, Adjustable type- 01 No. Outgoing :- (a) MCCB 63 Amps, Four pole, 415 Volts, 50 Hz-01 No (b) MCB DP 32 Amps, -01Nos (c) MCCB 40 Amp, Three pole,,,41.5 Volts, 50 HZ 16 KA -03 Nos. (d) Star delta Motor starter fully automatic suitable for 15 HP motor, the-al overload relay incudling Contactor and timer etc. suitable for induction motor with single phase protection relay, Auto phase sequence corrector, Low and high voltage correction and time delay 4 to 7 second complete - 03 Nos. (e) Digital Volt meter 0-500 Volts with selector switch -01 Nos (f) Digital Ampere meter 125 Amp 3 Phase, 96x96 Sqmm with CT ratio 12515 with selector switch- 01 Nos (g) Indicator lamp LED type of (R,Y,B) set of three = 01 Nos

1

-

-

... More
All as per item No.59 above but 3.15mm thick CRCA sheet outdoor type LT panel comprising following:- Location: RO Plant Incoming:- (a) On load change over switch 100 Amps capacity, ISI marked three phase and neutral. Outgoing :- (a) MCCB 63 Amps, Four Pole, 415 Volts, 50 Hz-02 Nos (b) DP MCB 32 Amps - 02 Nos (c) Digital Volt meter 0-500 Volts with selector switch -01 Nos (d) Digital Ampere meter 100 Amp 3 Phase, 96x96 Sqmm with CT ratio 100/5 with selector switch - 01 Nos (e) Indicator lamp LED type of (R,Y,B) set of three - 01 Nos

1

-

-

... More
All as per item No.59 above but 3.15mm thick CRCA sheet outdoor type LT panel comprising following:- Location: Site pump house Incoming:- (a) MCCB 250 Amp, Four pole, 415 Volts, 50 HZ, Adjustable type -01 No. Outgoing :- (a) MCCB 160 Amps, Four Pole, 415 Volts, 50 Hz-01 Nos (b) MCCB 100 Amps, Four Pole, 415 Volts, 50 Hz-01 Nos (c) MCCB 63 Amps, Four Pole, 415 Volts, 50 Hz-02 Nos (d) MCCB 40 Amps, Four Pole, 415 Volts, 50 Hz-02 Nos (e) Digital Volt meter 0-500 Volts with selector switch -01 Nos (f) Digital Ampere meter 250 Amp 3 Phase, 96x96 Sqmm with CT ratio 250/5 with SialeCter-switch - 01 Nos (g) indicator lamp LED type of (R,Y,-B) set of three - 01 Nos

1

-

-

... More
Supply, Installation testing and commissioning in repairs of Factory made LT panel board indoor type, dust & Vermin proof fabricated out of 2.0 mm thick CRCA sheet fixed duly powder coated complete using lugs,and glands of cable connection and having epoxy coated 100 amps copper bus bar 4 strips for 3 phase and neutral 415 Volts, 50Hz mounted on epoxy insulators, prewired with suitable size of PVC insulated multi strand copper conductor cable having independent enclosure for incoming and outgoing electrical connection and cable gland at bottom for incoming and outgoing and locking arrangement on front side and taking down existing LT panel, all as directed by Engineer in Charge including following fittings and fixtures. Panel shall be mounted on existing MS structure and cost for fixing the panel with necessary fasteners shall be included in quoted rate please. RO plant starter control panel Incoming:- (a) TPN 63 Amp, Four pole, 415 Volts, 50 HZ -01 No. (b) Digital Volt meter 0-500 Volts with selector switch -01 Nos (c) indicator lamp LED type of (R,Y,B) set of three = 01 Nos Outgoing :- (a) DP MCB 16 Amps - 02 Nos (b) TPN MCB 40 Amps, Four pole, 415 volt, 50 Hz - 01 No (c) TPN MCB 20 Amps, Four pole, 415 Volt, 50 Hz -01 No (d) Star delta Motor starter fully automatic suitable for 5.5 HP high pressure pump motor, thermal overload Relay incudling Contactor and timer etc.suitable for induction motor with single phase protection relay, Auto phase sequence corrector, Low and high voltage correction and time delay 4 to 7 second, start and stop push buttons complete - 01 Nos. (e) Star delta Motor starter fully automatic suitable for 2.0 HP low pressure pump motor, thermal overload Relay incudling Contactor and timer etc.suitable for induction motor with single phase protection relay, Auto phase sequence corrector, Low and high voltage correction and time delay 4 to 7 second, start and stop push buttons complete - 01 Nos.

2

-

-

... More
M&L for disconnecting of unserviceable electric panel/starter panel/RDS panel of any size/capacity and removing from site by taking necessary electric shut down from MES staff/JE and depositing the panel to MES store yard including cutting of all the cables, distmantling of PCC and make good after taking out all the debris all etc complete as specified and directed. Note :- The quoted rate shall be all inclusive including necessary T&P required for disconnection/cutting and necessary transportation for depositing to MES store yard.

10

-

-

... More
M&L for disconnecting of unserviceable voltage stabilizer of capacity 150 KVA and removing from site by taking necessary electric shut down from MES staff/JE and depositing the stabilizer to MES store yard including cutting of all the cables, distmantling of PCC and make good after taking out all the debris all etc complete as specified and directed. Note :- The quoted rate shall be all inclusive including necessary T&P required for disconnection/cutting and necessary transportation for depositing to MES store yard.

1

-

-

... More
M&L for servicing of LT panel of capacity I/C 630 A MCCB-01, Onload Change over switch-01 No, Outgoings - 400 A MCCB-01 No, 200A MCCB-02 Nos, 160 A MCCB-01 Nos, 63 A MCCB-01 Nos by taking necessary electrical shut down from MES staff/JE and repair/replacement of u/s thimbles and copper bus bar sleeve as per colour code, replacement of onload change over operating handle of existing models, refreshing of all the cable connections, including re-connecting the cable with proper cable gland of existing cable size and replacement panel bottom cover and making provn of hole for cable gland etc complete all as specified and directed

1

-

-

... More
S & F in repair PVC insulated 3 core 4 Sqmm copper multistranded PVC sheathed flexible cable suitable for Non clog motor ISI marked and conforming to IS : 694 and connecting to submersible pump with water proof jointing kit and to LT panel with lugs after taking out old unserviceable cable complete all as specified and as directed.

100

-

-

... More
S & F in repair PVC insulated 3 core 10 Sqmm copper multistranded PVC sheathed submersible flexible cable ISI marked and conforming to IS : 694 and connecting to submersible pump with water proof jointing kit and to LT panel with lugs after taking out old unserviceable cable complete all as specified and as directed.

200

-

-

... More
All as per Item No. 68 above but 3 core 16 Sqmm

300

-

-

... More
M&L for taking out NRV of 100mm/150mm dia from open well including taking column pipe of any size and length, disconnecting of NRV from column pipe, reconnecting of NRV after servicing/repairing, lowering of NRV duly connecting the column pipe, replacement of worn out nut, bolts, washers etc complete all as specified. Note : The quoted rate shall be inclusive of necessary T&P required for lifting and lowering of NRV from open well/neccessary drain out of water as required as per site requirement.

4

-

-

... More
Supply, fixing, jointing and testing of 100mm Cast iron Non Return valve without by pass arrangement , Swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed for following sizes of pipe:- Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) The quoted rate shall be inclusive of taking out GI/MS/HDPE pipe from open well, disconnecting of unserviceable NRV, replacement of unserviceable nut, bolts, washers etc, lowering of pipe duly assembleed the new NRV etc complete. (iii) The quoted rate shall be inclusive of T&P required for taking out column pipe of any capacity and size of any length from open well.

2

-

-

... More
All as per Item No. 71 above but 150 mm bore

4

-

-

... More
S & F in repair sluice valve class PN 1.6 heavy duty flanged end with SS spindle cast iron whel for operation conforming to IS-14846 of 2000 incl flanged joint on both side by using rubber gasket of size 80mm dia all as specified and directed.

1

-

-

... More
All as per item No. 73 above but 100 mm dia

1

-

-

... More
All as per item No. 73 above but 150 mm dia

2

-

-

... More
All as per item No. 73 above but 200 mm dia

1

-

-

... More
All as per item No. 73 above but 250 mm dia

1

-

-

... More
S & F in repair butterfly valve, PN 1.6 conforming to IS 13095/BS EN 593 BS 5155) (wafer type) gear operated, SG Iron Construction, SG Iron Disc which is accurately guided between the two stems, integrally moulded rubber lining (EPDM/Nitrile/Neoprone) of size 100 mm (4”) dia.

2

-

-

... More
All as per item No. 78 above but 150 mm bore

4

-

-

... More
All as per item No. 78 above but 200 mm bore

2

-

-

... More
S & F in repair MCCB 3 pole , 415 volts , fixed thermal and fixed magnetic setting 63 Amps to 100 Amps with braking capacity 16 KA, Ics=100% Icu, complete including replacement of u/s lugs, spreader connector all as specified and as directed .

4

-

-

... More
All as per item No. 81 above but 125 Amps , with breaking capacity 16 KA.

4

-

-

... More
S& F in repair MCCB 4 pole , 415 volts , fixed thermal and fixed magnetic setting upto 160 Amps with braking capacity 16 KA Ics=100% Icu, complete including replacement of u/s lugs, spreader connector complete all as specified and as directed.

6

-

-

... More
All as per item No. 83 above but 200 Amps , with braking capacity 35 KA.

2

-

-

... More
All as per item No. 83 above but 250 Amps , with braking capacity 35 KA.

2

-

-

... More
All as per item No. 83 above but 400 Amps , with braking capacity 35 KA.

1

-

-

... More
S&F in repair of onload changeover of 250 Amps all etc complete as specified and directed.

1

-

-

... More
S&F in repair of onload changeover of 200 Amps all etc complete as specified and directed.

1

-

-

... More
S&F in repair of onload changeover of 160 Amps with SS enclosure all etc complete as specified and directed.

1

-

-

... More
S&F in repair of start push button of Green colour as per site requirement all etc complete all as specified and as directed.

10

-

-

... More
S&F in repair of stop push button of Red colour as per site requirement all etc complete all as specified and as directed.

10

-

-

... More
S&F in repair of motor ON indiating light of green colour as per site requirement all etc complete all as specified and as directed.

15

-

-

... More
S&F in repair of motor Trip indiating light of yellow colour as per site requirement all etc complete all as specified and as directed.

15

-

-

... More
S&F in repair of neon LED light of Red/Yellow/Blue colour as per site requirement all etc complete all as specified and as directed.

30

-

-

... More
S&F in repair of rotary type selector switch all etc complete as specified and directed

10

-

-

... More
S & F in repair Power contactor FP AC-1 duty with 240 VAC Coil of capacity 400 Amps (MCX 43) with add-on aux contacts 2 NO+2 NC -01 Nos incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

1

-

-

... More
S & F in repair Power contactor FP AC-1 duty with 240 VAC Coil of capacity 325 Amps (MCX 41) with add-on Aux contact 2 NO+2 NC -01 Nos incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

1

-

-

... More
S & F in repair Power contactor FP AC-1 duty with 240 VAC Coil of capacity 16 Amps (MCX 01) incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

4

-

-

... More
S & F in repair Power contactor TP AC-3 duty with 240 VAC Coil of capacity 160 Amps (MNX 140) with add-on blocks 1 NO+1 NC -02 Nos incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

3

-

-

... More
S & F in repair Power contactor TP AC-3 duty with 240 VAC Coil of capacity 100 Amps (MNX 70) incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

5

-

-

... More
S & F in repair Power contactor TP AC-3 duty with 240 VAC Coil of capacity 22 Amps (MNX 22) with add-on blocks 1NO/1 NC -01 Nos incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

3

-

-

... More
S & F in repair Power contactor TP AC-3 duty with 240 VAC Coil of capacity 12 Amps (MNX 12) with add-on blocks 1NO/1 NC -01 Nos incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

5

-

-

... More
S & F in repair auxiliary contact block MNX A2,1 No 1 NC incl with all necessary internal electrical connections and taking out unserviceable all etc complete as specified and directed

6

-

-

... More
S & F in repair add-on auxiliary contact block 1 NO + 1 NC suitable for MNX / MCX type contactors including necssary internal electrical connections all etc complete as specified and directed

6

-

-

... More
S & F in repair thermal overload relay of capacity 135-225 Amps (MN-12)with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed

1

-

-

... More
S & F in repair thermal overload relay of capacity 60-100 (MN-12) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed

3

-

-

... More
S & F in repair thermal overload relay of capacity 45-75 (MN-5) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed

5

-

-

... More
S & F in repair thermal overload relay of capacity 4.5-7.5 (MN-2) Amps with all necessary internal electrical connection and taking out unserviceable all etc complete as specified and directed.

5

-

-

... More
S & F in repairs Single Phasing Preventer Relay type VSP-II, 415V including necessary internal electric connection with size copper wire all as specified and as directed by Engr-in-charge.

8

-

-

... More
S & F in repair electronic timer for star-delta time delay 30 to 120 or 3 to 30 seconds all as per existing sample complete including internal electric connection with suitable size copper wire all as specified and as directed.

8

-

-

... More
S&F in repair ammeter 415 volt, 3 phase digital type including necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and as directed.

5

-

-

... More
S&F in repair voltmeter 415 volt,3 phase upto 500 volts rating, analog type including necessary internal electric connection with suitable size copper wire & modification required for fitment as per site requirement complete all as specified and as directed.

5

-

-

... More
S & F in repair 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole and 6 Amps to 32 Amps current carrying capacity in the MCB DB/LT starter panel complete with connection testing and commissioning.

5

-

-

... More
S & F in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN and 16 Amps to 32 Amps current carrying capacity in the DB/LT starter panel complete with connection testing and commissioning.

4

-

-

... More
S&F in repair DOL starter in sheet metal enclosure max motor output at 415 Volt, 3 phase, 7.5KW, relay range 9-15 Amps complete all as specified and as directed.

2

-

-

... More
S&F in repair star delta starter max motor output at 415 Volt, 3 phase relay range 9--15 Amps in sheet metal enclosure type MN 16 type for 3 phase induction motor complete all as specified and as directed.

1

-

-

... More
S & F in repair of terminal strip 6 way all etc complete including electrical connection all as specified complete all as specified and as directed.

3

-

-

... More
S & F in repair of terminal strip 3 way all etc complete including electrical connection all as specified complete all as specified and as directed.

3

-

-

... More
M&L for preparation of old painted surfaces of centrifugal pump set of 70/75 HP capacity and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed

2

-

-

... More
All as per item No. 119 above but of capacity 60 HP

4

-

-

... More
All as per item No. 119 above but of capacity 40 HP

2

-

-

... More
All as per item No. 119 above but of capacity 20/15 HP

2

-

-

... More
All as per item No. 119 above but of capacity 10/7.5 HP

4

-

-

... More
All as per item No. 119 above but of capacity 5/3/2 HP

6

-

-

... More
Labour only for attending of Electric compliants of existing water supply Pump house panels /Borewells LT Panels/CF Motors/Subemrsible moters/Non-clog motors/Horizontal submesible , including connecting electrical accessories / spares of water supply installation, electrical fitting & short circuits in Pump house panel/CF Motors/Submersible motors/ Panels complete all as directed by Engineer-in-charge.(Any material required for attending complaints shall be measured & paid separately under respectvie item ) Notes (i) The complaints shall be attended and the defects shall be rectified by a team of expert and experienced electrician as applicable assisted with adequate No of helpers as directed by Enginner-in-charge. (ii) The complaints shall be attended and defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 250/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues.Contractor rep shall be available wef 0800 hrs to 2000 Hrs to receive and notify the complaint (iii) In case, after checking and attending the defect, it is not possible to rectify the defects within 08 hrs the facts shall be brought to the notice of Engineer-in -charge by the contractor /his rep . If Engineer -in-charge is satisfied with contractors view, no recovery will be made. (iv) Any types of machinery/, T & P required for attending the complaints shall be provided by the contracor. The quoted rate shall be inclusive of replacement of burnt out lugs, refreshing of burnt out cable, reconnecting, meggering, fault locating etc complete. (v) The elecrician shall always be in possession of all Electrician tools, LT Megger, Earth tester , Multimeter , Crimping tool, insulation tape, Hand gloves etc required at site.

30

-

-

... More
M & L in repairs for construction of valve pit chamber in PCC (1:5:10) masonry built in CM (1:4) with 3.00 thick and locking arrangement including excavation and earth works, PCC (1:4:8) type D2 for foundation PCC bed , coping in cement concrete (1:2:4) type B1, plastering 15 mm thick in CM (1:4), painting with one coat of bituminous black paint on all steel surface for size of chamber 1000 mm x 1000mm x 1200 mm including demolition of unserviceable damaged existing pit complete all as specified and as directed.

8

-

-

... More
M & L for development of borewell with compressed air and after by pumping muddy water all as specified and directed.

20

-

-

... More
S & F in repair of nylon rope of any size as per site requirement including taking out old unserviceable all etc complete as specified and directed

200

-

-

... More
M&L in repairs for earthing complete with copper earth plate electrode 60x60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth strip of 20x3.15mm (upto 7.5m in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including charcoal, rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel, 32mm dia light grade for protection of earth electrode, 20mm dia for watering all as specified and directed and tested on completion

6

-

-

... More
M&L in repairs for earthing complete with galvanised earth plate electrode 60x60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to GI earth strip of 32x6mm (upto 7.5m in length from earth plate) by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 including charcoal, rock salt, necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40mm thick cover with MS bar 8mm dia 150mm c/c reinforcement, watering funnel, 40mm dia light grade for protection of earth electrode, 20mm dia for watering all as specified and directed and tested on completion

10

-

-

... More
S & F in repair of Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including jointing with rivets/brazing etc all as specified and directed

40

-

-

... More
S & F in repair in repairs of GI strip 32 x 6mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including jointing with rivets/brazing etc all as specified and directed

20

-

-

... More
M&L for repair of Mild Steel Structure with framed work such grills, gratings etc with ends of bars shouldered and/or rivetted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work, portions framed and hung gates, including pintle hinges, stops, hand made sliding bolts etc as conforming to Fe290, Gde E-165 including two coats of paints of approved colour and including one coat of red oxide primer complete all as specified and as directed.

200

-

-

... More
Supply, laying and testing of 3.5 core x 95 Sqmm cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor with suitable size thimbling, laid in trench/floors/wall/ceiling all etc complete as specified and directed.

100

-

-

... More
Supply, laying and testing of 3.5 core x 70 Sqmm cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor with suitable size thimbling, laid in trench/floors/wall/ceiling all etc complete as specified and directed.

100

-

-

... More
Supply, laying and testing of 3.5 core x 50 Sqmm cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor with suitable size thimbling, laid in trench/floors/wall/ceiling all etc complete as specified and directed.

80

-

-

... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft / loose soil getting out and levelling of bottom surface to required level all as specified and as directed.

74

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil all as specified and as directed.

39

-

-

... More
Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point all as specified and as directed.

35

-

-

... More
M&L for unwashed sand cushioning to underground cable including punning down of sand in layer complete all as specified and directed. Note : Punned down thickness shall be measured for payment complete all as specified and as directed

25

-

-

... More
Supply and lay unreinforced precast concrete cable cover Class LV, type 2 flat, size 300mm x 180mm x40mm in trenches as protection to UG cable all as specified and directed

1390

-

-

... More
M&L for hardcore of broken stone or boulgers of gauge n exc 63mm deposited, spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface.

3

-

-

... More
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid dry aor laid dry and pointed complete all as specified and as directed

2

-

-

... More
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for

3.5

-

-

... More
M&L for 75 thick plain cement concrete (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub-base finished even and fair complete all as specified and as directed

20

-

-

... More
M&L in repairs for factory made machine pressed precast concrete rubber moulded interlocking paver block and shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade fixed with grey cement and pigment etc complete all as specified and directed

20

-

-

... More
M&L for disconnecting of unserviceable electric panel/starter panel of any size/capacity and removing from site by taking necessary electric shut down from MES staff/JE and reconnecting the panel after PCC foundation work including reconnecting of cables duly refreshing burnt thimbles, cable gland etc complete all as specified and directed. Note :- The PCC foundation/block masonry shall be measured and paid separately under relevant items of BOQ.

4

-

-

... More
Demolition of Bricks/block masonry in cement mortar complete all as specified and as directed

3

-

-

... More
M&L for Precast cement concrete block using PCC 1:3:6 type B1 20mm graded aggregate exc 10 cm in width and setting in mortar 1:6

3

-

-

... More
M&L for rendering 15mm thick in CM 1:4 on block masonry surface even and smooth without using extra cement mortar all as specified and directed

18

-

-

... More
M&L for Precast cement concrete 1:3:6 type C1 20mm graded aggregate including necessary form work finishing even and smooth without using extra cement complete all as specified and directed

2

-

-

... More
M & L for removing existing PCC foundation and providing new PCC foundation for installation of pump sets of 60 HP capacity on new base plate including high tension grouting bolts, complete all as specified and directed:- Note:- Cost of new Base Plate shall be inclusive of quoted rate.

4

-

-

... More
All as per item No. 152 above but of capacity 15 HP monoblock pumpset

2

-

-

... More
M & L for installation of pumpset on new PCC foundation and fixing with new bolts and nuts for base plate, fabricating to suction, delivery and priming line and connecting with existing lines, connecting power supply and testing, commissioning of pump set of 60 HP capacity, complete all as specified and directed.

4

-

-

... More
All as per item No. 154 above but of capacity 15 HP monoblock pumpset

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.