Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Civil And Construction
Eprocure
Opening Date7 Nov 2024
Closing Date27 Nov 2024
Tender Amount₹ 49,02,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.

5

-

-

... More
Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.

1.1

-

-

... More
Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar, including removal of entire debris as ordered outside MoD land complete all as directed.

7

-

-

... More
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as specified and as directed.

815

-

-

... More
Taking down chowkat or frame with shutters (including fittings & fixtures) area not exc 1.5 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.

127

-

-

... More
Taking down chowkat or frame with shutters (including grills, fittings & fixtures) area exc 1.5 Sqm but not exc 4 Sqm each (without taking off the shutters from the frame) of door/window including cutting holes for taking out hold fasts and making good the same including disturbed portion of jambs, cills, etc complete all as specified and as directed.

19

-

-

... More
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0 Sqm each with shutters (without taking off shutters from frame) and refixing in the same opening as ordered after other repair works are carried out complete all as specified and as directed.

4

-

-

... More
M&L for providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc. complete all as specified and as directed.

52

-

-

... More
M&L for post construction Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.

350

-

-

... More
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:4 complete all as specified & as directed.

4

-

-

... More
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed.

20

-

-

... More
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20 mm graded crushed stone aggregate) as in chajja, roof projection and the like in patches in any description for height upto 12 metres from average ground level including necessary formwork for fair finished surfaces of concrete and scaffolding complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of form work, scaffolding, safety belt, etc. (ii) Reinforcement shall be measured and paid for separately.

3

-

-

... More
Supply only Integral Water Proofing Compound (ISI Marked).

93

-

-

... More
Cutting chases in brick/ stone wall, pinning in, making good to facing where required and plastering in CM 1:4 to ends of edges of landing, steps, cills, lintels etc and cutting chases not exceeding 10 cm girth for concealed water tubing and similar works and making good cutting as per its original specfication complete all as directed.

60

-

-

... More
M&L for cutting holes in brick/stone walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as required including making good as per its original specification without any extra cost, not exc. half brick thick (Depth of embedded portion of holdfasts or lugs measured from the face of the jamb into the wall).

42

-

-

... More
S&F Second class hard wood kiln seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as specified and as directed.

0.3

-

-

... More
S&F factory made 35 mm thick second class hard wood plain framed panelled door shutter (any number of panels) with lock rail and panel of 9 mm thick BWP commercial ply or 12mm thick veneered particle boards with commercial veneering on both face the size of rail and style as per IS - 1003 (Part I) kiln seasoned and chemically pressure treated and fixed to chowkats complete all as specified and as directed.

14

-

-

... More
S&F factory made 35 mm thick second class hard wood glazed and skeleton door shutter open rebated and prepared to receive glass, guage etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (a), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats, complete all as specified and as directed.

14

-

-

... More
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window / Ceosetory windows & other Frames/ Chowkhat of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/sqmm, modules of elasticity 900 N/sqmm and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: MS hold fast/ lugs/ SS dash fasteners shall be measured and paid for separately.

58

-

-

... More
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer -In- Charge. Note: Stainless steel butt hinges and necessary SS screws shall be measured and paid for separately.

20

-

-

... More
S&F 200 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.

66

-

-

... More
S&F 100 mm long aluminium, powder coated, barrel tower bolt of extruded section and fixed.

198

-

-

... More
S&F 100 mm size butt hinges, medium weight cold rolled mild steel and fixed .

54

-

-

... More
S&F 100 mm size stainless steel butt hinges (ISI Marked), medium weight.

33

-

-

... More
S&F 75 mm size stainless steel butt hinges (ISI Marked), medium weight.

100

-

-

... More
S&F 150mm size extruded aluminium alloy handles (ISI Marked), fabricated type, anodised and fixed.

66

-

-

... More
S&F 125mm size aluminium handle, cast type, powder coated, complete all as specified & as directed.

24

-

-

... More
S&F 300 mm long aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.

6

-

-

... More
S&F mild steel 300mm ordinary rat tail rod pattern spring including roller and roller plate, complete all as specified & as directed.

10

-

-

... More
S&F 80mm long aluminium anodized floor door stopper double legged with rubber shoe, fixed to bottom rail of door as directed. Note :- Door stopper shall be conforming to the sample kept in GE’s office.

12

-

-

... More
S&F in repairs stainless steel drapery rod of 25mm dia (in lengths as directed) with & including stainless steel decorative SS bulb type finial at both ends / SS end socket and pair of stainless steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.

80

-

-

... More
S&F XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.

30

-

-

... More
S&F in repairs XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.

10

-

-

... More
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, framed signed boards, walk ways, railings, framework of water tanks and similar work including welding conforming to Fe.290 (Gde E-165), complete all as specified & as directed.

80

-

-

... More
S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 (Gde E-165) complete all as specified and as directed.

5

-

-

... More
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.

140

-

-

... More
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-290 (Gde E-165) complete all as specified and as directed.

85

-

-

... More
S&F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete conforming to Fe 290 (Gde E-165) complete all as specified and as directed.

90

-

-

... More
S&F plain mild steel wire 4.00 mm dia, galvanised class 3, in detached work such as for mosquito nets and fixing to straining bolts, hooks, eyes, etc. as directed (each line of wire to be measured) complete all as directed and as specified.

1

-

-

... More
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) including shutters with extruded built up standard tubular sections/ appropriate ‘Z’ sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings (where applicable) and/or the directions of Engineer-in-Charge complete all as specified & as directed.

810

-

-

... More
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) Grill 6 mm thick and 75 x 75mm diagonal spacing fixed with necessary H/F/C channel etc all as per manufacturer's instructions complete all as specified and as directed.

70

-

-

... More
S&F stainless steel (Grade-304) railings, integrated gates, etc including designer balusters, balls, accessories, etc in size, shape and design as directed, made of hollow tubes, channels, plates, balls, etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railings, integrated gates, etc with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc, of required size for gate with suitable arrangement as per approval of Engineer-in-Charge. Note : For payment purpose, only weight of stainless steel members shall be considered excluding accessories such as nuts, bolts, fasteners etc.

85

-

-

... More
S&F GI Chicken wire mesh cut to size made to shape as ordered including fixed to walls with nails for receiving the plaster complete all as directed. Note : Weight of GI chicken wire mesh shall be 250 to 300 gm/Sqm.

120

-

-

... More
M&L for cutting out cracks to 'V' section in existing roofs or terrace cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified & as directed.

40

-

-

... More
Material and labour for complete removal of existing water proofing treatment of any description or any other type of treatment over roof slab, parapets, chimney stacks, etc including cement plaster and cleaning the surface with wire brushes and washing with water, removing of insolvent materials and removing & depositing the debris, rubbish, etc outside MoD land, brushing neat cement slurry @ 3 Kg of cement per Sqm over the cleaned surface and provide 15mm thick screed bed/bedding layer/plaster in CM 1:3 mixed with integral Water Proofing Compound (WPC) as per manufacturer's instructions and finishing the surface even & smooth without using extra cement while the cement slurry is still green on RCC roof/parapet, provide oil bound bituminous primer @ 0.30 Kg/Sqm after bedding layer/plaster is cured with water for 7 days & completely dried, provide minimum 4mm thick APP based modified polymeric water proofing membrane weighing not less than 4.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 160 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed and finally finishing the top surface with one finishing coat of bituminous aluminium paint complete all as specified and as directed. Notes: (i) WPC shall be measured & paid for separately as ‘Supply only’. (ii) The work shall be carried out only through manufacturer or their authorised applicator and contractor shall submit a written guarantee of the manufacturer/authorised applicator for the effectiveness of WPT for 10 years from the date of completion of contract. (iii) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface. (iv) The net area of water proofing treatment shall be measured without any extra allowance for laps.

360

-

-

... More
M&L for machine cut mirror polished Kota stone 18 to 20mm thick in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed.

40

-

-

... More
M&L for 16 to 18 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.

45

-

-

... More
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as directed.

50

-

-

... More
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, hard standing, etc, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.

70

-

-

... More
M&L for average 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in levelling course of floor finishes complete all as specified and as directed.

830

-

-

... More
M&L for average 40mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in sunken floor and finished the surface even and smoth without using extra cement complete all as directed.

25

-

-

... More
M&L for non skid joint free ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.

60

-

-

... More
M&L for non skid joint free ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm (i.e. 600mm x 600mm or as directed by Engineer-in-Charge) as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.

770

-

-

... More
M&L for non skid joint free ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm (i.e. 600mm x 600mm or as directed by Engineer-in-Charge) on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.

75

-

-

... More
M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got approved from GE before incorporation in the work.

145

-

-

... More
M&L for Rendering 20 mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair faces of brick work of walls mixed with WPC mixed @ minimum 2% by weight of cement or as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.

220

-

-

... More
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.

250

-

-

... More
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling finished even and smooth without using extra cement complete all as specified and as directed.

75

-

-

... More
M&L for application of high build polymer modified cement mortar (1:3) mixed with 6 ltrs SBR latex per bag of cement {Compressive strength after 28 days ≥ 40 N/sqmm (According to ASTM C109)} in small patch work over column/ beams/ ceilings / walls surfaces 20 to 30mm thick in two layers over a coat of bonding agent like Nitobond SBR (1 ltr SBR + 3 Kg cement) applied as per manufacturer’s instructions for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Note :- SBR latex chemical shall be measured and paid for separately as ‘Supply only’.

220

-

-

... More
Supply only SBR latex chemical of Make Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian as approved by GE.

320

-

-

... More
M&L for preparation of newly plastered / unplastered surfaces of ceilings & applying three coats of white wash complete all as specified.

155

-

-

... More
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, Jet pressure washing and preparation of plastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.

700

-

-

... More
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick layer of white cement based wall care putty complete all as specified & as directed.

300

-

-

... More
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces of wall and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.

1050

-

-

... More
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.

320

-

-

... More
M&L for complete removal of existing treatment by mechanical means (any number of layers) by hand held sander/ long handle sander, rubbing down, stopping of distempered & Jet pressure washing and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions complete all as specified and as directed.

650

-

-

... More
M&L for writing letters or figures (Block, Roman, Italic or Indian) of size 8 to 10 cm high with thick synthetic enamel paint of approved tint over a synthetic enamel paint circle of 30 cm dia in approved tint for describing building numbers on concrete/plastered surfaces complete all as specified & as directed. Note : The font, style, matter, tint of paint & place of writing shall be as directed by the Engineer-in-Charge.

2

-

-

... More
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed.

50

-

-

... More
S&F 4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed.

4

-

-

... More
M&L for preparation of new surfaces of wood or wood based materials of any description over 10 cm width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer complete all as specified & as directed.

30

-

-

... More
M&L for preparation of old painted surfaces of wood and wood based material of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint complete all as specified & as directed.

10

-

-

... More
M&L for preparation of new steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint over a coat of zinc chrome primer complete all as specified & as directed.

24

-

-

... More
Taking up or down 15 mm bore GI tubing and connection, including cleaning for re-fixing stacking at site where directed.

80

-

-

... More
Taking up or down old 20 mm bore GI tubing and connection, including cleaning for re-fixing stacking at site where directed.

55

-

-

... More
Supplying and laying of 20mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement fixed to walls and ceilings or laid in floors complete all as specified and as directed.

80

-

-

... More
Supplying and laying of 25mm outer diameter CPVC pipes SDR 11 & Plain CPVC SDR 11 Fittings such as bends, elbows, unions, end pieces, etc and fixed with solvent cement fixed to walls and ceilings or laid in floors complete all as specified and as directed.

35

-

-

... More
M&L for galvanized steel water tubing medium grade of 20mm bore (ISI marked) with & including all fittings, fixed to walls and ceilings or laid in floors, complete all as specified and as directed.

20

-

-

... More
S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.

10

-

-

... More
S&F in repairs ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe or brass ferrule of 20 mm bore and fixed (minimum weight 210 gms) complete all as specified and as directed..

10

-

-

... More
S&F in repairs 15 mm bore bib tap long nose with wall flange, fancy type, cast copper alloy, chromium plated, long shank screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6509 or equivalent in makes mentioned in Appendix 'B' here-in-after.

12

-

-

... More
S&F in repairs 15 mm bore two way bib tap fancy type, brass, chromium plated with flange and aerator, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 6812 or equivalent in makes mentioned in Appendix 'B' here-in-after.

4

-

-

... More
S&F in repairs Health Faucet brass chromium plated with 1.2 mtr SS Chrome plated EPDM tube & ABS hook wall mounted type complete all as specified and as directed. Make: Prayag Cat No. BEA-85 or equivalent in makes mentioned in Appendix 'B' here-in-after.

4

-

-

... More
S&F in repairs 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed. Make: Prayag Cat No. 6510 or equivalent in makes mentioned in Appendix 'B' here-in-after.

14

-

-

... More
S&F in repairs 15 mm bore pillar taps, Swan Neck, fancy type, CP cast copper alloy, with capstan heads, with long screwed shanks and fly-nuts, screwed down high pressure, with or without lettered 'Hot' or 'Cold' screwed for iron pipe complete all as directed. Make : Prayag Cat No 6514 or equivalent in makes mentioned in Appendix 'B' here-in-after.

4

-

-

... More
S&F in repairs chromium plated 100mm over head ABS shower round with 225mm SS Arms & Flange, swivel joints fixing to steel pipes etc complete all as directed. Make : Prayag Cat No BS-65 or equivalent in makes mentioned in Appendix 'B' here-in-after.

4

-

-

... More
S&F in repair CP brass soap dish including fixing with brass screws complete all as specified & as directed. Make : Prayag Cat No BA-45 or equivalent in makes mentioned in Appendix 'B' here-in-after

8

-

-

... More
S&F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges fixed on wall with PVC rawl plug & chromium plated brass screws complete all as specified and as directed. Make : Prayag Cat No BA-40 or equivalent in makes mentioned in Appendix 'B' here-in-after.

4

-

-

... More
S&F in repairs PVC connection 15mm bore and 45cm long with two Nos of brass check nuts and washers complete all as directed.

14

-

-

... More
S&F in repairs PVC flexible waste pipe for 32mm dia waste coupling complete all as specified and as directed

6

-

-

... More
S&F in repairs 75 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/sqcm, fixed to wall/ ceilings or in floors etc. complete all as directed.

8

-

-

... More
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints laid in floors/ fixed to walls, complete all as specified & as directed.

20

-

-

... More
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.

40

-

-

... More
S&F 75 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.

4

-

-

... More
S&F 110 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.

8

-

-

... More
S&F 75 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.

2

-

-

... More
S&F 110 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.

4

-

-

... More
S&F 75mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.

2

-

-

... More
S&F 110mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.

4

-

-

... More
S&F PVC (SWR) Vent cowl 75mm bore size fixed complete all as directed.

4

-

-

... More
S&F PVC (SWR) Vent cowl 110mm bore size fixed complete all as directed.

4

-

-

... More
S&F in repairs PVC (SWR) gully trap 125/110 mm including jonting the same with solvent cement complete all as specified & as directed.

6

-

-

... More
S&F in repairs vitreous china oval shape counter sunk wash hand basin (white) of size 560mm x 470mm x 190mm with & including 32 mm dia PVC waste pipe and 32mm chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed complete all as specified & as directed.

4

-

-

... More
S&F in repairs vitreous china squatting pan (Orissa pattern) water closet (white) of size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, including lime concrete bedding and making good disturbed floor, complete all as specified and as directed.

4

-

-

... More
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, complete all as specified & as directed.

4

-

-

... More
S&F in repairs vitreous china urinal, half stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including CP brass spreader, PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete all as specified and as directed.

2

-

-

... More
S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified and as directed.

8

-

-

... More
S&F in repairs 600mm x 450mm looking mirror of selected quality glass not less than 5.5mm thick, beveled edge looking mirror fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified.

4

-

-

... More
Disconnecting existing PVC water tanks fixed in any description of capacity exceeding 500 ltrs and not exceeding 1000 ltrs, setting aside (or lowering if required) for repairs, cleaning and removing scale and dirts etc from tanks and from mouths of circulating pipes etc and hoisting as ordered, including reconnecting and re-fixing in same position and testing on completion complete all as directed.

6

-

-

... More
Dismantling of existing any type & any capacity water storage tank fixed in any description and S&F new 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.

4

-

-

... More
M&L for providing and laying water proofing treatment on roofs of slabs / sunken floors consisting of & including the following :- (a) After preparation of surfaces, apply first layer of slurry of cement @ 0.488 kg/sqm mixed with Acrylic Polymer TAPCRETE P 151 of CICO Chemicals @ 0.253 kg/sqm. (b) Laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with Acrylic Polymer TAPCRETE P 151 of CICO Chemicals and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment shall be taken upto 30 cm on parapet / side wall and tucked into groove in parapet / side wall all around. (d) Provide oil bound bituminous primer @ 0.30 Kg/Sqm and provide minimum 3mm thick plain APP based modified polymeric water proofing membrane weighing not less than 3.00 Kg/Sqm reinforced with non woven polyester matt fabric weighing not less than 150 gms/Sqm with over laps 100 mm longitudinal direction (side laps) and 150 mm on the transverse direction (end laps) by thermo-fused torch flame application method as per detailed procedure as directed. (e) Provision of 50mm dia, 60cm long GI spout pipe. Notes : (i) The work shall be carried out only through specialised agency approved by GE. (ii) The net area of water proofing treatment shall be measured without any extra allowance for laps. (iii) Equivalent product of Fosroc / Dr. Fixit / Pidilite / Sika shall be allowed as per approval of GE.

45

-

-

... More
Cutting/ Chipping/ Dismantling of spall / loose damaged concrete from soffits of RCC slab / other RCC structural members in a controlled manner carefully by low impact high frequency hammer or by manual chipping without damaging the existing concrete upto good parent concrete to expose the existing reinforcement (direct hammering should be avoided) average thickness of 40-70 mm including cleaning the exposed surfaces by water jet pressure pump at 4 to 5 kg/ Sqcm pressure to remove chlorides and loose particles, air drying the surface etc for further treatment with & including all necessary tools, safety measures like helmet, safety belt, adequate labour insurance, scaffolding, etc. for height upto 15 metre from average ground level under the supervision of qualified supervisor (the damaged ceiling/ concrete shall only be measured) complete all as specified and as directed.

50

-

-

... More
M&L for cleaning existing reinforcement bars with wire brush / rotary wire brush making the surface free from cement skin, loose particles, dirt, etc and applying rust remover/converter (Rebaklense RR of M/s Fosroc / Amandur of GK technocom or equivalent of Dr. Fixit / SIKA / Pidilite) over the corroded reinforcement bars where ever micro concreting is required and cleaning the same after application with & including all necessary tools, scaffolding, etc. for height upto 15 metre from average ground level complete all as specified and as directed.

50

-

-

... More
Supply and application of Nitozinc Primer of M/S Fosroc or equivalent of Dr. Fixit / SIKA / Pidilite over the exposed steel reinforcement after removing the rust scales from the exposed reinforcement bars with & including all necessary tools, scaffolding, etc. for height upto 15 metre from average ground level complete all as specified and as directed.

50

-

-

... More
M&L for applying Nitobond EP (2.5 Kg pack and coverage area 5.5 Sqm/ 4.5 Kg pack and coverage area 10 Sqm) epoxy bonding agent over the old concrete surfaces including the cost of all materials, rent of tools, scaffolding, brush etc. for height upto 15 metre from average ground level complete all as directed by the Engineer-in-Charge. Make: Fosroc or equivalent of Krishna Conchem / Dr. Fixit / SIKA / Pidilite / BASF / Sunanda / Asian as approved by GE.

50

-

-

... More
M&L for providing additional reinforcement TMT bars in place of more than 1/3 corroded reinforcement bars including cutting, bending, placing and fixing in position using 'Lokfix' of M/S Fosroc or equivalent of Dr. Fixit / SIKA / Pidilite with & including all necessary tools, scaffolding, etc. for height upto 15 metre from average ground level complete all as specified and as directed. Note : Weight of TMT bars shall only be measured for payment purpose.

90

-

-

... More
M&L for non shrink cementitious micro concrete (‘SikaRep Microcrete-4’ of Sika / ‘Renderoc RG’ of Fosroc or equivalent of Dr. Fixit) meeting ASTM C1107 standard in average thickness 70mm and having minimum compressive strength 50 N/sqmm after 28 days as per ASTM C109, for repair to column, beam, slab, etc, complete all as per manufacturer’s instructions cost inclusive of scaffolding, shuttering, formwork, curing etc. for height upto 15 metre from average ground level complete all as directed. Notes : (i) Quoted rate shall deemed to be inclusive of form work, scaffolding, safety belt, etc. (ii) Reinforcement shall be measured and paid for separately.

50

-

-

... More
M&L for Teflon nozzles compatible with epoxy injector, drilling holes of 12mm dia, upto 100mm deep holes in structural members at the interval of 500mm c/c for slab, 300mm c/c for column and beam in staggered manner or along the crack as directed by the Engineer-in-Charge in RCC structural element including cleaning of the holes by air blower and inserting 8-10mm dia Teflon nozzles compatible with epoxy injector and having machined external end to receive outlet of grouting gun. Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing and allow to cure the system minimum 8 hours before grouting including removing nozzle projections, excess putty if any over concrete element grinding, levelling and finishing the external surface, after completion of the work, etc, complete all as directed by the Engineer-in-Charge.

30

-

-

... More
M&L for grouting of RCC structure with low viscous two parts of epoxy (mixed in ratio as specified by manufacturer) by using pressure pump and pressure grouting with compressor at about 1 kg to RCC beams/ chajjas/ slab/ columns as per manufacturer’s instructions and direction and cutting the Teflon nozzles after grouting and making surface good complete all as directed by the Engineer-in-Charge. Make of low viscous epoxy shall be of Krishna Conchem / Dr. Fixit / SIKA / Fosroc / Pidilite / BASF / Sunanda / Asian

14

-

-

... More
E&M Items: Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.

296

-

-

... More
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sunk type pressed steel terminal boxes concealed in wall for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.

182

-

-

... More
All as per serial item No. 123 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.

107

-

-

... More
All as per serial item No. 123 here-in-before but for one 16 Amp and 6 Amp (3 pin) combined, modular switch socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.

7

-

-

... More
S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed.

289

-

-

... More
S&F in repairs modular switch, single pole, one way, 16 Amp, 1 module with all accessories complete all as directed.

7

-

-

... More
S&F in repairs modular socket 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as directed.

107

-

-

... More
S&F in repairs modular socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as directed.

7

-

-

... More
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.

188

-

-

... More
S&F in repairs clear white 20 Watt wall mounted 4 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.

64

-

-

... More
S&F in repairs clear white 10 Watt wall mounted 2 ft LED batten type decorative light fitting, minimum CCT 5700K, 230 Volts, 50 Hz, extruded aluminium housing & polycarbonate diffuser, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed.

26

-

-

... More
Taking down carefully existing serviceable LED batten of any type/ Watt and refixing the same at old or new position after completion of other repair work including making connections complete all as specified and as directed.

30

-

-

... More
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fitting, High Efficiency, minimum IP 65 protection, CCT - 5700K, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, powder coated pressure die cast aluminium housing, top opening with separate driver compartment and clear PMMA/polycarbonate/toughened glass heat resistant cover, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion, fixed over & including mounting bracket made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, complete all as specified and as directed.

4

-

-

... More
Taking down existing flood light fitting of any description and S&F new 200 W LED flood light fitting, IP-65 rated with high pressure die cast aluminium housing, lens and toughened glass cover, system lumen efficacy ≥ 110 Lm/W, Power factor ≥ 0.95, CCT 5700K, with & including external Surge Protection Device (SPD) 10 kV, asymmetric fixing to existing bracket including nut bolts of suitable size and electrically connected to the existing system and testing on completion complete all as directed.

2

-

-

... More
Taking down carefully existing ceiling fan of any make or size with down rod and refixing the same after minor repair work i.e. cleaning, greasing, blade leveling etc. complete with down rod and connecting with & including new 3 core 1.5 sqmm copper conductor flexible cable from ceiling rose to fan with all accessories complete all as directed.

54

-

-

... More
S&F in repair modular step type fan regulator 120 W, 2 module, AC, 230V, complete all as specified and as directed.

54

-

-

... More
M&L for Fan hook of standard type as per SSR specification including making necessary arrangements in existing RCC slab ceiling by cutting RCC slab to the required depth upto existing MS bars and tie up with new one and making good disturbed surfaces complete all as specified and as directed.

10

-

-

... More
S&F 300mm sweep, metal body, exhaust fan, AC, single phase, 230/240 V, copper winding motor, with louver shutter and connecting with & including three core copper conductor flexible cord of 1.5 Sqmm cross sectional area of required length from ceiling rose to the connector block of the exhaust fan including taking down existing old exhaust fan and depositing to MES store yard with & including cutting, opening of required size hole (Square/ Round) through RR masonry/ brick walls for fixing exhaust fan and making good disturbed surfaces of wall with CM 1:4 and painting with two coats of existing colour to match the wall complete all as directed by Engineer-in-Charge. Note : Old Exhaust Fan shall be deposited to Store Yard of AGE E/M (N) Jamnagar.

4

-

-

... More
S&F in repairs Distribution Board (DB) sheet metal enclosure, VTPN, TPN, Vertical, 4 Way, flush mounted & surface mounting, suitable for fixing 3 Pole / 4 Pole MCCBs & MCBs, 415 Volts with 200 Amps rated bus bar, DB fitted with bus bar neutral links blank plates, fitted with and including MCCB, 4 Pole, 100 Amps rating, rupturing capacity 25 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal Magnetic Protection - 01 No., complete all as specified and as directed. Make of DB :- Legrand Cat No. 5077 50 or equivalent in makes mentioned in Appendix 'B' here-in-after. Make of MCCB :- Legrand Cat No. 4200 55 or equivalent in makes mentioned in Appendix 'B' here-in-after. Note : (i) Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) Quoted rates shall be inclusive of DB & MCCB as above. (iii) DB & MCCB of same make shall be provided.

1

-

-

... More
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 100 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.

12

-

-

... More
S&F in repairs Distribution Board (DB) sheet metal enclosure, TPN, 4 way with 100 Amps rated bus bar, double door, 415 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.

1

-

-

... More
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.

69

-

-

... More
S&F in repairs MCB SPN 40 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as specified and as directed.

12

-

-

... More
S&F in repairs MCB TP 63 Amp, 415 V, 50 Hz, AC supply, 10kA, 'C' Curve, complete all as specified and as directed.

1

-

-

... More
S&F in repairs MCB TPN 63 Amp, 415 V, 50 Hz, AC supply, 10kA, 'C' Curve, complete all as specified and as directed.

1

-

-

... More
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.

250

-

-

... More
M&L for sub main wiring with 04 runs of 10 sqmm (nominal area) size main cable & 01 run of 10 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring of any size / type complete all as specified & as directed. Notes :- (i) 04 runs of 10 sqmm size main cable, 01 run of 10 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.

20

-

-

... More
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 35 sqmm 3.5 core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.

80

-

-

... More
Supply and laying/fixing 40 mm bore High Density Polyethylene (HDPE) Pipes of Grade ‘PE 100’, Pressure Class ‘PN 8’, ‘SDR-17’, ISI marked, with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.

60

-

-

... More
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.

2

-

-

... More
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.

19

-

-

... More
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.

17

-

-

... More
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.

2

-

-

... More
Taking down carefully existing Electric centralised Storage Water Heater 500 Litre capacity including pump, motor, MS canopy, all accessories, etc, fixed over roof of 2nd floor including dismantling carefully water inlet/ outlet connections & electric connections and keep the same in safe place till completion of other repair works and refixing the same at existing location including proper fixing by clamps/ bolts on floor or foundation and making necessary electrical and water inlet/ outlet connections and testing on completion for smooth working to entire satisfaction of Engineer-in-Charge, complete all as directed.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.