Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date6 Sep 2024
Closing Date5 Oct 2024
Tender AmountRefer Documents
Costs
EMD
₹ 48,400Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672670_1Bid Award Id
ViewTender No
GE(A)/GNR/TOKEN/63 of 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and directed.
100
-
-
M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
120
-
-
M&L PCC (1:4:8) type C-2 using 40mm graded stone aggregate as in foundation filling and mass concrete as in foundation filling and mass concrete all as completed as directed.
0.5
-
-
M&L for cement concrete 1:2:4 type B1 (using 40mm graded stone aggregate) as in surface channels and drains including complete all as specified and directed.
0.5
-
-
M&L PCC (1:2:4) type B-0 (using 12.5mm graded aggergate) in roof kerbs,or mud stops, rounded or chamferded edges complete all as specified and directed.
0.2
-
-
M&L for PCC 1:3:6 type C-1 using 20mm graded stone for embedding of hold fast, filling etc. complete all as specified and directed.
0.4
-
-
M&L, providing cement concrete1:2:4 type B1 using 20mm grades aggregate as in , coping ,benching, bressumers, steps, incl necessary form work complete all as specified and as directed.
1
-
-
M&L, precast cement concrete Block Masonary with solid blocks 1:3:6 type C1 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 complete all as specified and directed .
4
-
-
M&L, precast cement concrete Block Masonary with solid blocks type C1, 1:3:6 (20mm graded stone aggregate) exc 10 cm in width and setting in mortar 1:6 except block complete all as specified and directed .
0.5
-
-
M&L for providing precast cement concrete (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in manhole covers including placing the cover in position and set in cement mortar 1:6 complete all as specified and directed. Note : Reinforcement shall be measured and paid seperately.
0.25
-
-
Providing pre-cast Cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in landings, cover slabs (for manholes etc) and similar articles, set in CM (1:4) complete all as specified and directed.
1
-
-
M&L for RCC 1:1.5:3 type A-1 as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including demolition of existing RCC work in any position complete all as specified and directed.
0.8
-
-
Supply only Integral waterproofing compound complete all as specified and directed.
14.5
-
-
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
8
-
-
M&L for 18-20mm thick Makrana white Marble work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking plateforms, wash basin platform and like in cememnt mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to watch with marble shade including rounding exposed edges complete all as specified and directed.
12
-
-
M&L for Granite (of any type of coloured) work (table rubbed and polished) 20mm thick in steps jambs, pillars, window cills, cooking plateform /partition and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15mm thick screed bed in CM 1:6 incl moulding, chamfering of edges complete.
8
-
-
M&L for use and waste of form work to soffit of suspanded slab such as roof slab ,floor slab landing and similar work n exc 200mm thick (horizontally or sloping complete all as specified and as directed.
8
-
-
S&F 35mm thick 2nd class hardwood glazed and skeleton shutters open rebated and prepared to receive glass or gauge etc(without sash bar), edges of framing plain, chamfered or rounded fitted with cut and mitred beads for securing glass , etc size of members of shutters as specified in SSR part I ,section 8 clause 8.24(a) fitted to chowkats complete all as specified and directed.
24
-
-
Supply & Fix 35 mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and as directed.
24
-
-
Taking down chowkats or frames but with shutters (without taking off shutters from the frame) n.exc 1.50 sqm each and steel window/ ventilator n. exc. 1.5 sqm each (without taking off shutters from the frames) complete all as specified and directed.
32
-
-
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exc 1.5 Sqm but n.exc 4 Sqm each complete all as specified and directed.
12
-
-
Taking down old shutters of any description exc. 1 sqm but not exc. 2 sqm each complete all as specified and directed.
4
-
-
Taking down and refixing of shutters in same opening after easing and adjusting of any description exc 1 Sqm but n.exc 2.0 Sqm each complete all as specified and directed.
4
-
-
Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame., complete as specified by the manufacturer and as per directions of Engineer-in-charge.
40
-
-
Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing toframes, complete as specified by the manufacturer and as per directions of Engineer- in-charge.
13
-
-
S&F 150mm aluminium anodised barrel tower bolts of extruded section all as specified.
16
-
-
S&F, aluminium, anodised barrel tower bolts 200mm long of extruded section and fixed complete all as specified and directed.
40
-
-
S&F 300 mm long Aluminium alloy ,anodised sliding door bolt with hasp staple (bolt type ) and fixing clips of sheet ,cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed .
8
-
-
S&F butt hinges, medium weight, cold rolled, mild steel of size 100 mm complete all as specified and directed.
24
-
-
S&F MS 300 mm ordinery rat rail rod pattern spring including roller and roller plate complete all as specified and as directed .
12
-
-
S&F, aluminium handles 150mm size, cast type, anodised complete all as specified and directed.
64
-
-
S&F, aluminium peg set of Six complete all as specified and as directed.
12
-
-
S&F, Aluminium eyes piece glass for main gate and shutter complete all as specified and directed.
4
-
-
S&F, in repair, 20mm dia Harrison rails, mild steel chromium plated with fixing brackets, stops, rolleres etc. complete all as specified and as directed.
70
-
-
S&F, in repair stainless steel tubular towel rail 20mm dia, D type, 600mm long complete all as specified and directed.
8
-
-
S&F 150mm long floor door stopper of aluminum alloy body and tongue , anodized with hard drawn steel spring complete all as specified and directed
12
-
-
S&F galvanised mild steel wire cloth 0.56 mm nomonal dia of bar and 1.18 mm avrage width of aperture ,fixed with tined tacks or galvanised wire staples complete all as specified and as directed.
36
-
-
S&F M.S Framed work such as grills gratings etc with ends of bars sholdered and/or riveted into spikes ,framed guard bars /railings all as directed .
205
-
-
M&L for TMT 6 to 8 mm dia bar, cut to length, bent to shape required, including cranking, bending, hooking ends, binding with and inlcuding mild steel wire (annealed) not less than steel wire 0.9mm dia or securing with clips and confirming to FE-410-S and 310-0) complete all as specified and directed.
245
-
-
S&F, rolled mild steel section as in main and cross beams hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding door fixed with angle cleats or other connecting plates conforming to Fe-290, Gde E-165 all as specified and directed.
120
-
-
S&F 1.25 mm thick Pressed steel frame size 125 x 60 for doors with one or more rebates including necessary fixing lugs, hinges ( 125mm long-12 Nos & 75mm long - 2 Nos for each door ), lock strike plate, hold fast etc., including Frames shall be filled with PCC 1:3:6., type C-0 (12.5 mm graded stone aggregate) complete all as specified and directed.
60
-
-
Powder coated aluminium (minimum thickness of powder coating 50 micron) work for partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
210
-
-
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50mm thick of an colour (as approved by GE) having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws in single length including dismantling of existing roof sheet complete all as specified and directed.
12
-
-
Taking/removing existing tar felt treatment of any description from RCC roof slab, terrace etc. by means of MS scrapper patty or any other suitable tools and removing to a distance 500 mtr from the starting point and depositing complete all as specified and directed.
145
-
-
S&F, 20mm thick factory made solid PVC flush Kitchen CB shutter/Shutter, uPVC, make from cp-extruded three layer rigid foam sheet (single extruded process) with 0.8 to 1mm thick outer face layer having density not less than 1400 kg/cum and density of central core material not less 600 kg/cum, manufactured by and ISO 9001:2015 certified compaly and fixing in frame at site ith and including 02 nos Cabinet hings frameless full overlay adjustable, 01 Nos S S fency handle, 01 Nos SS tower bolts, ball catches with 8mm dia steel ball and brass body and striding plate including letting for each shutter etc. for Cup Board/Kitchen cabinets as per specifiecation & drawing complete all as specified and directed.
72
-
-
M&L for water proofing treatment to roof surfaces including a coat of applied bituminous shalitex primer @ 0.30 litre/sqm eenly on roof surface and a coat of hot bitumen and 85/25 @ 1.2 Kg/sqm shall be applied on primed surface and laying 3mm thick APP modified polymeric membrane (weight not less than 3 Kg/sqm) unrolled and bonded completly to the substrate with side overlap of 75mm and end overlap of 100mm and then sealed/fused by flame or bitumen and a coat of hot blown bitumen grade 85/25 " 1.2 Kg/sqm shall be applied on top of AOO modified polymeric membrane as per manufacturer instruction and finally it will be finished with a coat of aluminium paint " 0.20 kg/sqm complete all as specified and directed .
145
-
-
M&L for sunken floor treatment as described as under (i) to (vii):-
(i) Demolition of cement concrete of any description and in any position not otherwise specifically Provided or in any type of filling in sunken portion & cleaned the sunken portion incl vertical wall surface complete as directed. (ii) M&L to fill the sunken floor with PCC (1:5:10) type E-2 using Brick aggregarte over the treated surface complete as directed .
(iii) M&L 40mm thick (Min) PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate with integral water proofing compound as per manufacture instruction instructions on bottom of sunken portion with proper slope towards spout . Vertical sides shall be plastered in CM (1:3) 15mm thick mixed with water proofing compound as per manufacturer instructions .Plaster shall be extended over PCC coving when the same is green i.e. PCC & Plastger be carried out at the same time complete all as specified and directed.
(iv) After laying sewage /Plumbing pipes with fixtures in position 2 coats of OMIPLAS EP -101 epoxy compound shall be applied complete all as specified and directed.
(v) Spouts of 25mm dia GI pipe light grade projecting 450 mm clear of face outer a wall with mosquito proof cap on inner face of pipe shall be provided to drain out seepage water including cutting holes and making good if needed as specified and directed .
(vi) Test again of water tightness by pounding for 72 hours & rectify defects if any till total elimination of defects complete all as specified and directed .the sunken portion shall be tested for leakage /seepage /dampness by pounding with water for 72 hours .in case any defect is noteced the portion shall be grounted with cement slurry mixed with suitable chemical & tested again .The process of grouting and testing shall be repeated till leakage /seepage /dampness is eliminated as specified and directed .
6
-
-
M&L cutting out cracks to V-section in existing roofs slab or terrae, cleaning out, wetting, grouting with cement and sand slurry 1:3 with mixing of WPC "2% by weight of cement complete all as specified and directed.
100
-
-
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing etc and including 20mm thick screed bed in CM 1:6 complete as specified and directed.
12
-
-
M&L for machine cut kota stone slab, 18-20 mm thick in riser and thired single piece on steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:4 including grinding and mirror finshed polishing complete all as specified and directed.
8
-
-
M&L for rubber moulded exterior grade joint less coloured tiles, 10mm thick, area exc 0.06 sqm but n.exc 0.38 sqm with grey cement and pigments set & jointed and pointed in neat cement slurry over and including 15mm thick cement screed bed in cm 1:6 with grey cement and pigments in floors including taking down old tile complete all as specified and directed.
4
-
-
M&L for 75mm thick PCC 1:2:4 type B2, using 40mm graded stone aggregate as in sub base to flooring finished even and smooth without using extra cement complete all as specified and as directed.
4
-
-
M&L for cement concrete 75mm thick type C-2 (1:3:6) using 40 mm graded agg as in sub base to flooring and including demolition of existing concrete work complete all as specified and as directed.
50
-
-
M&L for 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in sub base and flooring finished fair and even to receive floor finishes complete all as specified and directed.
249
-
-
M&L, glazed joint free coloured ceramic tiles in vertical surface as in skirting & dado, 7 to 8 mm thick area exc 0.06 Sqm but n.exc 0.18 Sqm over and including 10 mm thick rendering in CM1:4 set & jointed in neat cement slurry & pointed in coloured cement to match complete all as specified and directed.
160
-
-
M&L, non skid white ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 Sqm, in floors over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed
12
-
-
M & L, non skid ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 Sqm, in floors over and including 15 mm thick screed bed in CM 1:6 as in floor etc set & jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed
176
-
-
M&L for 15mm thick rendering on fair faces of concrete surfaces of roof as water proofing treatment in CM 1:4, including finishing the surface even and smooth complete all as specified and directed.
151
-
-
M&L for 5 mm thick cement plaster in CM 1:4 on ceiling, soffits, chajja protection etc complete all as specified and directed.
80
-
-
M&L for 10mm thick cement plaster on fair faces of birck work or concrete surfaces on wall in CM 1:6 finished the plaster surface fair and even complete all as specified and directed.
280
-
-
M&L for rendering 15 mm thick in two layers consisting of first layer 10mm thick in CM 1:4 and top layer 05mm thick in CM (1:4) plastering with water proofing compound (@ 3% by weight of cement) on fair faces of brick work or concrete surface and finishing the surface even and smooth without using extra cement all as specified and directed. (Note : Water proofing compound shall be measured and paid separately).
350
-
-
Taking down old cement plaster any description on brick or stone wall/ceiling etc including racking out joints, hacking for key, scrubbing down with water etc complete as specified and directed.
710
-
-
Preparation of new plastered surfaces and applying two coat of oil bound distemper over and including a layer of wall care putty to achive a smooth finish surface (average thickness 1 mm) complete all as specified and directed.
280
-
-
M&L for preparation of old plastered surface by complete removal of existing treatment and applying two coat of oild bound distemper over and including a layer of wall care putty (average thickness 1mm) complete all as specified and directed.
320
-
-
Preparing of plastered or unplastered old decorated surfaces of walls by complete removal of existing treatment, moulds, moss and efflorescent salt and treating oil and greasy spots and applying three coat of white wash on walls including cornices etc complete all as specified and directed
60
-
-
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
350
-
-
Preparation of plastered or unplastered old decorated surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soots, treating oily/greasy spots, moss and efflorescence and applying two coat of cement base paint over on walls including cornices etc complete all as specified and directed.
25
-
-
Preparation of New plastered surfaces of ceiling and applying Three coat of white wash on ceiling including cornices etc complete all as specified and directed.
80
-
-
Preparation of plastered or unplastered old decorated surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soots, treating oily/greasy spots, moss and efflorescence and applying two coat of white wash on ceiling including cornices etc complete all as specified and directed.
40
-
-
S&F, 4.8 mm thick plain sheet glass, ordinary quality and glazing not exceeding 0.8 Sqm in each pane fixed with glass putty complet all as specified and directed.
24
-
-
S&F, figured glass pin head type (Figured glass), Sheet glass 4mm thick ordinary quality and glazing with oil putty or rubber and aluminium beading in squares n.exc. 0.5 sqm in each pane complete all as specified and directed.
2
-
-
M&L, preparing of new wooden surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
96
-
-
M&L for preparation of old wooden surface of any description, over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
8
-
-
M&L, preparing of new steel surface exceeding 10 cm in width or girth and applying two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
8
-
-
M&L, preparation old previously treated steel Surfaces of any description, over 10cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint on the steel surfaces, complete all as specified and directed.
1
-
-
Taking up or down steel tubing 15 mm bore and connection including cleaning for refixing complete all as specified and directed.
48
-
-
Taking up or down steel tubing 20 mm bore and connection including cleaning for refixing complete all as specified and directed.
40
-
-
Taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed.
20
-
-
Supply and laying of 16 mm outer dia CPVC pipe SDR 11 fitting on walls /ceiling or laying in floors including connection to old GI pipe if required complete all as specified
48
-
-
Supply and laying of 20 mm outer dia CPVC pipe SDR 11 fitting on walls /ceiling or laying in floors including connection to old GI pipe if required complete all as specified
40
-
-
Supply and laying of 25 mm outer dia CPVC pipe SDR 11 fitting on walls /ceiling or laying in floors including connection to old GI pipe if required complete all as specified
20
-
-
Supply, hoisting and fixing in position, in repair, 500 litres capacity rotational moulded polyethylene water storage tank double layered (cylindrical, vertical with closed top) including dismantling of old PVC/AC water storage tank of 500 liter capacity complete all as specified and directed.
4
-
-
S&F in repairs bib taps cast copper alloy chromium plated fancy type with crutch or butterfly handle screw down ,screwed for iron pipe or or brass ferrule for 15 mm bore of pipe complete all as specified and as directed.
12
-
-
S&F, CP brass, wash basin centre hole mixer (long nose) 15 mm bore dia, for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
4
-
-
S&F, CP brass, wall mixer (long nose) 15 mm bore dia, for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
4
-
-
S&F, in repairs, 15mm stop valves, fancy type brass chromium plated for iron pipe or for unions and fixed to 15mm bore pipe, complete all as specified and directed.
24
-
-
S&F in repair 20mm Gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed.
4
-
-
S&F in repair 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified and as directed.
4
-
-
S&F, 32mm bore bottle trap of PTMT having minimum water seal of 25mm (minimum weight 32mm-260 gms) complete all as specified and directed.
4
-
-
S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
16
-
-
S&F, 50mm PVC (SWR) pipes single socket in any length and including bends and sockets complete all as specified and directed.
4
-
-
S&F, in repairs, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors and fixed to walls with PVC holdingg with suitable mild steel angle clamps complete all as specified and directed.
15
-
-
S&F, in repairs, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints laid in trenches or in floors and fixed to walls with PVC holdingg with suitable mild steel angle clamps complete all as specified and directed.
15
-
-
S&F, in repairs, 110mm bore PVC(SWR) bends any radius, complete all as specified and directed.
12
-
-
S&F 75mm bore PVC (SWR) Tee equal or unequal any radius complete all as specified and directed.
4
-
-
S&F 110mm bore PVC (SWR) Tee equal or unequal any radius complete all as specified and directed.
4
-
-
S &F PVC (SWR) 75 mm dia vent cowl complete all as specified and directed.
4
-
-
S&F in repairs, 125/110mm bore PVC (SWR) 'P’ trap complete all as specified and directed.
4
-
-
S&F in repairs, 75mm bore dia PVC floor trap (SWR) plain with grating including jointing with solvent cement to waste pipe complete all as specified and directed.
12
-
-
M&L for concrete bed to 200mm drain pipes including forming cradles in PCC 1:4:8 type D2 using 40mm graded stone aggregate complete all as specified and directed.
9
-
-
M&L for 200mm bore reinforced concrete pipe class NP2 laid and jointed with one coller per length of pipe complete all as specified and directed.
9
-
-
S&F in repair vitreous china squatting pan, orrisa pattern, size 580mm x 440mm white, with integral foot rests (excluding flushing cistern & flush pipe) including making good to disturbed floor with PCC complete all as specified and directed.
4
-
-
S&F, brass chromium plated shower rose with or without swivel joint, 125mm size complete all as specified and directed.
4
-
-
S&F sinks made of stainless steel 0.8mm mm thick kitchen with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm including coupling, west pipe etc. complete all as specified and directed.
4
-
-
S&F in repairs PVC low level 10 lit capacity valveless syphonic action type flushing cistern including 32mm dia PVC flush pipe fixed in repairs complete all as specified and directed.
4
-
-
S&F kitchen plate rack of stainless steel of size 720mm x 600mm x 230mm made out of 1mm thick steel sheet complete all as specified and directed.
4
-
-
S&F, PVC cabinet mirror size 350mm x 450mm fixed with steel screw with rowl plug complete all as specified and directed.
4
-
-
S&F, oval type wash hand basing superiod quality 550 x 400mm size fitted and including suitable waste coupling with west pipe complete all as specified and directed.
4
-
-
S&F 600x450 mm bevelled edge of slected quality glass mounted on 6 mm thick AC building board or commercial plywood and fixed to wooden plug with chromium plated brass screws and cup washers complete all as specified and directed.
4
-
-
S & F Soap dish chromium plated approximate size 160x 160x90mm complete all as specified and directed.
4
-
-
S7F, 5.5mm thick glass shelf of size 600mm long fency type fixed and including chromium plated grils, screws and wooden/plastic cleats complete all as specified and directed.
4
-
-
S&F, 5.5mm thick glass shelf assembly fency type size 250mmx250mm fixed with and including chromium plates brass screws and wooden/plastic cleats complete all as specified and directed.
4
-
-
Demolition of precast concrete articles and pre-cast cement concrete block walling, ashlar fencings, dressed stone work including all quoins, arches, pillars etc. built in cement mortar complete all as specified and directed.
4.5
-
-
Demolition of cement concrete (unreinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed
38.46
-
-
Demolition of plain cement Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
1
-
-
Demolition of reinforced cement concrete in any position not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
0.25
-
-
Dismantling wrought iron or mild steel work of any description not otherwise proviceded for complete all as specified and as directed.
1.2
-
-
Demolition and breaking up drain pipes (Salt glazed ware, AC or reinforced concrete) det in cement mortar internal dia of pipe in 150mm to 200mm complete all as specified and directed.
9
-
-
Taking down carefully copper/aluminium point wiring (Light, fan, socket or power etc.) complete including fitting such as switches, socket, bell pushes, ceiling roses, pendants/batten holder, call bell, regulators etc all as specified and directed by Engr-in-charge.
128
-
-
M&L for point wiring for PVC conduit concealed in brick or stone wall using FRLS PVC sheathed multistrand copper conductor wire 1.5 sqmm single core for one light/fan point controlled by one switch including modular white cover plate with frame of suitable modules over modular metal flush box concealed type for earth continuity insulated PVC unsheathed (green colour) 1.5 sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engr-in-charge for the following :-
-
-
-
(a) One light/fan/bell point controlled by one switch
87
-
-
(b) One 3 pin, 5 Amp socket outlet on independent board.
12
-
-
(c) One 3 pin, 5 Amp socket outlet on the same board controlled by another switch.
16
-
-
(d) One light point controlled by two switches of two way.
1
-
-
M&L for point wiring for one light/fan/bell point controlled by one switch one way in & including PVC conduit concealed in brick or stone wall using FRLS PVC unsheathed multistrand copper conductor wire 2.5 sqmm single core for one light/fan point controlled by one switch including modular white cover plate with frame of suitable modules over modular metal flush box concealed type for earth continuity insulated PVC unsheathed (green colour) 2.5 sqmm copper earth wire connected to common earth dolly using complete all as specified and directed by Engr-in-charge for for 6/16 Amp independent socket.
12
-
-
S&F modular bell push 6 Amps, 1 module complete all as specified and directed.
4
-
-
S&F modular switch one way 16 Amps flush type 230 volts complete all as specified.
12
-
-
S&F, in repair, modular switch, 2 way, 6 Amps complete all as specified and directed.
2
-
-
S&F, in repairs, bell, A.C. 230 Volts, single pole, Ding doll, complete all as specified and directed.
4
-
-
S&F modular socket outlet 3 pin 6 & 16 Amps flush type 230 volts complete all as specified.
12
-
-
S&F ceiling rose 3 terminal size 50x65mm surface type 230 volts complete all as specified.
62
-
-
S&F, modular switch piano, flush button single pole, one way 6 Amps complete all as specified and directed.
111
-
-
S&F modular socket 3 pin 6 Amps flush type 230 volts complete all as specified.
28
-
-
S&F, modular fan step type regulator, suitable for 1200mm/1400mm sweep ceiling fan, 2 module complete all as specified and directed.
12
-
-
Labour only for Cutting openings, through brick walls for fixing of exhaust fan, including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard-core etc. and rubbish not exc. 50m. Forming jambs, etc. to openings for 300mm exhaust fan including cutting in wall fo cement mortar 1:6, toothing, and properly bonding into old work, also facing, jointing and pointing to match existing work, complete
8
-
-
S&F, Holder insulated body with back plate for batten fitting suitable for LED lamp complete all as specified and directed.
26
-
-
S&F LED Adore Lamp 9W, B22 base 6500K CDL type complete all as directed by Engr-In-charge. Make: Havells/Crompton/Bajaj
26
-
-
Supply and fix of exhaust fan, 230 mm sweep, 1400 rpm, MS body heavy duty, AC single phase, 230 volts with, blades, and frame and louvers including connection with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e anchor nut, bolt, washer, grouting and making good to disturbed surface complete all as specified and as directed.
4
-
-
Supply and fix of exhaust fan, 300 mm sweep, 1400 rpm, MS body heavy duty, AC single phase, 230 volts with, blades, and frame and louvers including connection with 0.5 sqmm multistranded copper conductor flexible wire from ceiling rose, necessary fixing arrangement i.e anchor nut, bolt, washer, grouting and making good to disturbed surface complete all as specified and as directed.
4
-
-
Disconnecting carefully and taking down the existing ceiling fan of any size, and depositing to MES E/M store for safe custody complete all as directed by Engr-in-Charge
20
-
-
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated, 230Volts, single phase, 50 Hz AC, energy saving high density PUF insulation complete with all accessories such as safety valve, thermostate, NRV, inlet and outlet (cold & hot) PVC pipes upto 450mm long, with 15A plug top etc. complete all as specified and directed.
4
-
-
S&F LED compact fitting for LED tube double side connection of 1x20W, 220V, AC decorative box type 4ft with integral LED driver including 20W, T8 tube rod complete all as directed by Engr-In-charge.
31
-
-
S&F LED compact fitting for LED tube double side connection of 1x10W, 220V, AC decorative box type 2ft with integral LED driver including 20W, T8 tube rod complete all as directed by Engr-In-charge.
4
-
-
S&F Distribution Board VTPN, 4 way, 415 volts, factory made powder coated, double door with neutral and earth link, including 3 pole MCCB 63 Amps rating, 16KA breaking capacity for incoming supply and provision of MCB SP/TP for out going supply complete all as specified and directed.
1
-
-
Taking down carefully old unsv submain wiring of any type/any size with PVC conduit or casing caping complete all as specified and directed.
30
-
-
M&L for sub-main wiring with 2 single core 4 Sqmm PVC insulated, unsheathed, 1100Volts grade, copper multi stranded conductor drawn in PVC concealed conduit ISI marked including its fitting and fixtures such as tee, bends, elbows, junction boxes, etc. including drawing a run of PVC insulated, unsheathed, 650/1100Volts grade, copper conductor multi stranded 4 Sqmm size as continuous earth wire drawn through and connected to main switch/ DB and testing on completion. Note: (i). 2 run of main conductor and one run of earth conductor shall be measured as one length. (ii) Rates quoted shall be inclusive of cutting wall for concealing conduit and making good the same in cement mortar 1:3.
30
-
-
Taking down carefully old unserviceable main switches/ Distribution board any type including fuses MCB etc after removing all connection, wires and making good the disturb surface complete all as directed by Engineer-in-charge.
5
-
-
Taking out KWH electric meter single phase by disconnecting electrical connections from DB and kept in safe custody for reuse complete all as specified and directed.
4
-
-
S&F Sheet metal enclosure double door for DB's SPN 8 way 240 V having 200 A rated bus bar complete all as specified and directed by Engr-Incharge.
4
-
-
S&F MCB SPN 32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge.
4
-
-
S&F MCB SP 6-32A, 240 V -10 KA all as specified and as directed by Engineer-in-charge.
24
-
-
S&F ceiling fans 1200mm sweep energy efficient five star rated 230 volts with blades, down rods, electronic regulator control type and accessories with brushless direct current motor (BLDC) and connecting up with 3 runs of suitable size single core PVC cable from ceiling rose to fan complete all as specified and as directed.
12
-
-
S&F 30W New generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficient LED as lighting source and PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 for bldg security light with GI pipe bracket of suitable size for fitting complete all as specified and directed by Engineer-in-charge. Make Havells/Bajaj/Philips/Crompton
3
-
-
M&L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth Lead 4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I connected to earth test point using earth strip of 25x4mm as earth lead all as specified and testing on completion including provision of earth lead protected by 20 mm dia light grade GI pipe & watering pipe shall be 15 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions:-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 15 mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 20 mm bore light grade 7.5m.