Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 64,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_627997_1Bid Award Id
ViewTender No
8380/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
S&F Mild Steel of gde Fe 410-W as in plain plates cut to required sizes including forming holes without any attachement etc complete all as specified and directed.
230
-
-
M & L Rolled steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connectiong plates complete including cutting, grinding, welding etc Fe-290 (Gde E-165) as required complete all as specified.and directed.
8671
-
-
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc welding etc Fe-290 (Gde E-165)as required complete all as specified.and directed.
1247
-
-
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc complete all as specified and directed.
721
-
-
S&F Pre- painted galvatume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified as specified
2
-
-
M&L preparation of newly steel surfaces exc 10cm width or girth and applying 2 coats of synthethic enamel paint over a coat of primer etc complete all as specified and directed.
295
-
-
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft/loose soil etc complete all as directed.
772.2
-
-
Removing excavated material not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point in soils etc complete
232
-
-
M&L for hardcore with broken stones or boulders of gauge not exc 63mm spread and levelled in layers not exc 15cm thick watered and well rammed to a true surface etc complete all as directed.
78
-
-
M&L 100 mm thick PCC 1:4:8 using 40 mm graded stone aggregate as in sub base complete all as specified and directed
772.2
-
-
M&L for 100mm thick type B-2 1:2:4 using 40mm graded stone aggregate as in floor Cement concrete in foundations, filling and mass concrete complete all as specified and directed
772.2
-
-
S&F for plastic dividing strips, 1.5mm thick 38mm wide laid in floors as dircted.
330.5
-
-
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 1.5 sqmm (Phase - R Y B, Neutral - Black) and earth continuity conductor 1.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed modular steel terminal boxes of thickness not less than 1.2 mm covered with suitable and required size of modular box, plate with cover for mounting modular switches, sockets, fan regulators complete including making good the wall surfaces with matching colour on wall for the following
-
-
-
One light point controlled by one switch.
30
-
-
One fan point controlled by one switch.
16
-
-
One socket outlet 6 amp controlled by one switch on the same board with other switches.
10
-
-
One socket outlet 6 amp controlled by one switch on indepdendent board.
10
-
-
M&L for point wiring with 1100 volts grade PVC insulated FR-LSH multistranded copper conductor cable 2.5 sqmm (Phase - R,Y,B, Neutral - Black) and earth continuity conductor 2.5 sqmm (Green) drawn into and including concealed rigid non metallic PVC conduit medium grade not less than 20 mm dia ISI marked ivory colour with all conduit fittings / fixing accessories and sunken galvanized pressed steel terminal box of thickness not less than 1.2 mm covered with suitable and required size of modular box, plate with cover complete for one 16 amp socket outlet controlled by one switch on independent board including making good the wall surfaces with matching colour on wall complete all as specified and directed by Engineer-in-Charge. Make : Havells / Polycab / Finolex / Plaza
5
-
-
S&F switch piano flush button single pole one way 6 amp complete.
66
-
-
S&F switch piano flush button single pole one way 16 amp complete.
5
-
-
S&F socket outlet 2 in 1, 3 pin 6 & 16 amp flush type complete.
5
-
-
S&F socket outlet 2 in 1, 2 & 3 pin, 6 amp, flush type complete.
20
-
-
S&F ceiling rose 3 plates polycarbonate body complete.
46
-
-
S&F MCB distribution board SPN, 240 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
1
-
-
M&L for submain wiring alongwith earth continuity conductor with PVC insulated FRLSH multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into and including concealed rigid non metallic PVC conduit, medium grade, ISI marked ivory colour along with accessories of following nominal sizes:-
-
-
-
(a) 2x6 sqmm + 1x6 sqmm earth continuity conductor in 20 mm dia conduit..
70
-
-
S&F MCB distribution board SPN, 240 volts, 8 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
1
-
-
M&L for earthing complete with galvanized steel earth plate electrode 60cmX60cmX6mm thick buried directly in ground (earth plate not less than 2.25 mtr deep below the normal ground level) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth lead wire of 4.0mm dia by means of nuts bolts, washers, check nuts of iron or steel including PCC pits and RCC cover in PCC 1:2:4 (type B-1) and necessary earth work in any type of soil medium grade GI watering pipe 20 mm dia with funnel and wire mesh and 15mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate all as specified and shown in EP-5 of SSR Part-I. all specified
1
-
-
S&F MCB distribution board ETPN, 415 volts, 4 ways powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required.
1
-
-
S&F LED batten (1.2 m) made of Aluminium housing with a PC glossy diffuser duly prewired connection having a nominal system lumen output of 2000 lumens at a minimum system efficacy of 100+ lumens per watt and total power consumption not less than 20 watt including driver. It has a rated system life time of 40000 burning hours at L70 and should have a color temperature of 6500K, CRI80, THD 10% and PF 0.95 complete.
22
-
-
S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
16
-
-
S&FLED 20W streetlight made up of pressure die cast housing with prismatic polycarbonate diffuser and individual LED's with secondary optics and IP65 protection complete with fixing arrangement and connections as directed
8
-
-
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core.
35
-
-
Excavating in trenches in Hard / dense / soft soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, etc. and getting out complete all as specified and directed.
8.1
-
-
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
0.81
-
-
Returing filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
7.29
-
-
Supply and laying DWC(Double wall corrugated) HDPE pipe,ISI marked,IS 16205(part 24):2017 part 2 of outer dia 50 mm and inner dia 38 mmwith smooth internal and profiled external surface for non pressure underground cable including all connected acceseries like coupler,o-ring etc complete all as specified and directed
30
-
-
S&F MCBs as per load requirement 'C' series of breaking capacity 10 KA, ISI marked including required wiring connections with copper lugs of suitable size provided in MCB DBs of following ratings:-
-
-
-
(a) Single pole 6 to 32 amp.
12
-
-
(b) Double pole 32 amp.
1
-
-
© Four pole 63 amp.
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements