Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date12 Dec 2024
Closing Soon1 Jan 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material & Labour for sand cushioning for under ground cable with locally available sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and onsolidations, complete all as specified and directed. (Note-Punned thickness ie 18 mm will be measured and paid)

19.44

-

-

... More
Supplying and laying unreinforced precast concrete cable cover, class HV, type 2, flat size 450mm x 180mm x 40mm

1333

-

-

... More
Taking out unserviceable cable any type/size from trenches, pole road, duct etc including necessary joints, unserviceable fittings, cable protection cover and pipes etc complete. Note: Excavation and earthwork shall be measured & paid for seperatly under respective item of this schedule of work.

310

-

-

... More
Supply, laying, commissioning and testing in repairs of XLPE insulated, seceened, PVC bedded, galvanises steel strip or wire armoured heavy duty electric power cable with aluminium conductor, 6.35/11 KV suitable for 11000 volts grade, cross-sectional area 95 sqmm 3 core complete all as specified and directed.

310

-

-

... More
Material & Labour for replacement of cable jointing kit for 11 kV grade (Earthed) HT cable for indoor termination cold shrinkable type complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured aluminium conductor cable of following sizes complete all as specified and directed by EIC.

9

-

-

... More
All as per item 8 Above but out door type. (a) 50 to 95 sqmm

9

-

-

... More
All as per item 8 above but for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, straight through type.

6

-

-

... More
Dismantling of unserviceable insulators of any type/size and removal from site.

12

-

-

... More
Supply and fixing pin type Polymer type, vitreous, white, brown or green insulators including galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts, 150 mm height 150 mm dia including section of straps of 38x5mm size 20mm dia of bolts, nuts & washers for 11000 volts grade complete.

6

-

-

... More
Supply and fixing disc type insulator, Polymer type, vitreous white brown or green insulators for working pressure 11000 volt of 145 mm height 255mm dia ball and socket type Two-in-series assembly for tension with tension clamp for conductors including bolts, nuts & washers complete.

6

-

-

... More
Dismantling of unserviceable air break gang operated switch 11000 volts grade from overhead HT line structure vertical/horizontal mounted including insulators and operating mechanism complete all as specified and directed.

4

-

-

... More
Supply, installation, commisioning and testing 11 KV outdoor type gang opearted air break switch, 9 Polymer type insulator, triple pole vertical type mechanically operated, mounted on polymer insulators and steel frame, with operating mechanism worked from ground level with 25mm dia GI pipe (Medium Grade) operating rod of suitable length for current rating upto 200 Amps with dropout fuse connected with new ACSR conductor. Note :- Quoted rate shall deem to be included cost of steel frame, GI pipe suitable length and drop out fuses.

4

-

-

... More
Dismantling unserviceable expulsion fuse assembly including insulators, 11000 volts grade from pole.

4

-

-

... More
Supply and fixing explusion fuse single pole including insulators and drop out fuse 11000 volt grade of 25 to 50 Amps capacity complete.(Set of Three)

4

-

-

... More
Dismantling unserviceable lightening arrestors including insulators, 11000 volts grade from poles and removal from site. (Set of Three)

6

-

-

... More
Supply, installation, commisioning and testing of lightening arrestor non linear resistor type confirming to IS: 3070 part I complete line discharge class-2 normal discharge current to 10 Kilo Amps and high discharge capacity 65 Kilo Amps assembly suitable for 11000 Volts including all clamps, nuts, bolts,washers and connecting to earth with 32X6 mm GI Strip complete. (Set of Three). Note: Earth strip 32X6 mm shall be measured & paid for seperately under respective item of this schedule of work.

4

-

-

... More
Detecting of fault of HT UG cable (any place any length any type /size) with help of vehicle mounted cable fault locator including detecting exact location of cable fault and remove of cable for rectification. Note:-Cable fault locator shall be aggranged within 2 days from of inimation by Engineer-in-charge otherwise Penalty of RS 2000/day will be levised for each day of delay for for every segment of cable . If fault not located no payment shall be made to contractor.

3

-

-

... More
Supply and fixing on HT pole stay assembly complete with accessories shown in electrical plate No 1 of MES SSR Part I with stay rod of 20 mm dia including loop type insulator suitable for 11 KV size 90x140mm)with clearance of hole 25.5mm and MS stay plate size 300x300x6mm, stay clamps, galvanised iron stay wire of size 7/4 mm of suitable length etc complete all as specified. Note: Excavation, earthwork and PCC shall be measured & paid for seperately under respective items of this schedule of work.

3

-

-

... More
Disconnecting and taking out existing HT 11 KV (VCB) from housing and cleaning, rubbing and overhauling the mechanical parts including greasing, oiling, replacement of unserviceable Trip coil, Breaker charging motor, gear pinion, roller switch, big gear checking of SF6 quality of vacuum interrupter, insulation resistances, static contact resistance etc and re-assembling the same after requir and made the VCB serviceable including making all electrical connection and testing (IR value, Ratio test, polarity test) and connection verification of 11 KV current transformer (set of three) by PRIMARY INJECTION KIT and testing and calibration of relay (set of two over current and one earth fualt) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all specified and directed. Note :- (i) All spares parts of VCB panel shall be measured and paid for separately under relevent item as supply only. (ii) The repair work and testing of VCB shall be carried out by the representative of OEM only.

3

-

-

... More
Supply only breaker charging motor including gear assembly 220 volt AC of 11 KV VCB panel. Make: ABB or make

1

-

-

... More
Supply install, testing and commissioning of Closing coil suitable for 11 KV HT VCB of make L & T 110V DC complete all as sspecified and directed.

2

-

-

... More
Supply install, testing and commissioning of Triping coil suitable for 11 KV HT VCB of make L & T 110V DC complete all as sspecified and directed.

2

-

-

... More
Supply install, testing and commissioning of Power Pack , 230V AC input, 110V DC output, 100VA suitable for 11 KV HT VCB of make L & T 110V DC complete all as sspecified and directed.

1

-

-

... More
Supply install, testing and commissioning of 11 KV, indoor CT 100 A/50A+1A ACC Class 5P ratio suitable for VCB of Make-ABB or equivalent model of make

2

-

-

... More
Supply install, testing and commissioning of 11 KV, indoor PT 110 V suitable for SF6 VCB of Make-ABB or equivalent model of make

2

-

-

... More
Supply & Fixing in repair 11 KV panel indicating lamp fitting RYB LED type suitable for 12/24 volt DC complete with base complete all as specified ad directed.

2

-

-

... More
Supply & Fixing in repair 11 KV VCB panel volt ampere frequency meter digital type suitable for 12/24 volt DC complete with base complete all as specified ad directed.

2

-

-

... More
Supply, fixing and testing 11 KV bus insulator suitable for 11 KV SF6 VCB Panel complete.

2

-

-

... More
Earthing complete with galvanized steel earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below ground level connected to galvanized iron earth strip of size 32x6mm by means of bolt, nut, check nut and washer of galvanized iron or steel protected by galvanized iron pipe of 40 mm bore medium grade, incl. Funnel, 20mm dia bore galvanised iron pipe medium grade for watering, wire mesh, charcoal or coke and common salt in alternative layers all around the earth electrode compacted thickness 15 cm incl. Excavation and earth work, PCC 1:3:6 type C-1, CI pit cover, incl disposal of surplus soil to a distance n.exc. 50 m complete testing on completion, all complete as shown in electrical plate No. 3 of MES SSR Part-I all as specified. Note :- (i) Cost of earth strip and GI protection pipe up to a distance 7.5 metre shall be included in the quoted rate. (ii )On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.

5

-

-

... More
Supply, fixing and testing 11 KV HT ceramic bushing of transformer 11 KV/433 volt indoor/outdoor of various capacities complete all as specified and directed by Engineer-in-Charge including taking out old bushing.

15

-

-

... More
Supply fixing and testing ceramic bushing LT side of transformer 11 KV/433 volt indoor/outdoor of various capacities ie upto and including 350 KVA complete all as specified and directed by Engineer-in-Charge including taking out old bushing.

14

-

-

... More
Supply, fixing and testing bushing rod of brass both ends threaded including nut, check nut and washer LT side of transformer 11 KV/433 Volt indoor/outdoor of various Capacity upto and including 350 KVA complete the same all as specified and directed by Engineer-in-Charge including taking out old bushing rod.

13

-

-

... More
Supply & fixing in repair gasket set of synthetic rubberized cork sheet 10 mm thick for transformer top lid cover suitable for transformer of capacity upto 350 KVA.

12

-

-

... More
Painting of transformer after cleaning the body surfaceof transformer by rubbing with emery paper to remove oil strains, dust etc and applying two coat of heat resistance paint by spray paint incl writing SM/MES no and capacity of transformer of capacity upto 350 KVA complete.

8

-

-

... More
Dehydration / filteration of transformer oil by means of centrifugal filteration plant to achieved the specified dielectric strength upto 40 KV at 2.5 mm gap in existing possesion of transformer of any capacity and transformer oil for toping up at various sub station complete. Note: Oil for topping shall be measured & paid for seperately under respective item of this schedule of work after dehydration/ filtteration of existing oil.

7200

-

-

... More
Supply only transformer oil of approved quality as per IS No : 335-1993 low viscosity type having dielectric strenght of 40-60 KV in 2.5 mm gap for toping up complete all as specified and directed (Make : Castrol, Power oil, gulf as approved by GE

600

-

-

... More
Supply & Fixing in replacement breather assembly complete with 250 grams silica gel suitable for any capacity / model of transformer to air column of conservator tank complete all as specified and directed.

8

-

-

... More
Supply & Fixing in replacement breather assembly complete with 500 grams silica gel suitable for any capacity / model of transformer to air column of conservator tank complete all as specified and directed.

7

-

-

... More
Taking proper shut down in writing, disconnecting the LT and HT electric main from transformer of any capacity, removing the transformer from pole structure/platform shifting to authorised workshop after draining out the transformer oil at site, dismantling and disconnecting damaged HT/LT coil to facilitate necessary repairs, rewinding / reconditioning re-assembling the transformer, bringing back to the site, refilling new or dehydrated old oil, transformer, bringing back to the site, refilling new or dehydrated old oil, connecting with existing electrical system of HT and LT including testing complete all as specified and directed. (Winding wire and other items mentioned in schedule 'A' will be measured and paid separately). Note :- (i) Placing/removing stand by transformer in the place of defective transformer under repair will be the responsibility of the contractor, stand by transformer will be provided by the department. (ii) Oil shall be collected by the Contractor for refilling. (iii) Winding wire and other items shall be measured & paid for seperately under respective item of this schedule of work. (iv) The repair work under each transformer shall be ordered by GE in writting after visual inspection on opening of transformer. (v) Quoted rates shall be deemed to include cost of new gasket.

5

-

-

... More
Rewinding of LT/HT coil, conforming to the orginal winding of the transformer of any make/capacity with super enamelled DPC insulated copper wire/strip of appropriate guage and turns and cutting and moving of burnt winding cleaning of core and drying in over after assembly including allied materials complete all as specified and directed. Note :- (i) Old retrieved materials shall be contractors property and necessary amount as per schedule of credit shall be deducted from contractor's dues. (ii) Rewinding work shall be carried out through OEM authorised representative. (iii) The repair work under each transformer shall be ordered by GE in writting after visual inspection on opening of transformer. (iv) Quoted rates shall be deemed to include cost of new gasket.

300

-

-

... More
Dismantling and taking down old unsv PCC / Steel poles all as specified and directed

8

-

-

... More
Supply and errection steel tubular pole complete with cast iron base plate, final tapper plug, nuts bolts and screws as specified type 410 SP-55 (11 Mtr Long) complete all as specified and directed.

8

-

-

... More
Material & Labour for cement concrete 1:3:6 type C2 using 40mm stone aggregate as in foundation of pole etc complete all as specified and directed.

4.96

-

-

... More
Material & Labour for PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concrete for poles all as specified directed.

0.4

-

-

... More
Material & Labour for plain cement Concrete (1:2:4) Type B-1 using 20 mm graded aggregate for coping of poles including necessary farm work and finishing the exposed surface even and smooth with out using extra cement complete all as specified and directed at site

0.8

-

-

... More
Excavating in trenches 1.5m or part thereof in depth beyond the first 1.5 m and getting out in soft/loose soil complete.

1.44

-

-

... More
Dismantling cross arms of MS channel or angle sections/anti climbing devices etc complete all as directed.

2

-

-

... More
Material & Labour for Structural steel work conforming to grade Fe-410S as in cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections, including , nuts, bolts, washers, welding , bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat , one finishing coat of aluminium paint and epoxy coating sufficient for 11KV insulation complete all as specified and directed.

2

-

-

... More
Supplying and fixing aluminium strip 32x6mm, fixing with screws, including making holes for cable/thimbles as required complete all as specified

52

-

-

... More
Supply & fixing in replacement of HT jumper of 70 sqmm single core aluminium cable conductor incl PG Clamps, nut bolts, thimbles and washer required at site complete all as specified and directed.

70

-

-

... More
Material & labour for preparation of old painted steel and iron surfaces and painting to steel tubular poles of any height 9/11/13 metre, any type (double swan / single swan) with two coats of synthetic enamel paint upto 1.5 m height above from ground level (in yellow and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles incl painting on cross arms, bracing, clamps etc and writing pole number with black synthetic enamel paint complete all as specified and directed.

45

-

-

... More
Material & labour for preparation of old painted steel and iron surfaces and painting to 4 pole structure PCC/Steel poles of any height 9/11/13 metre, any type (double swan / single swan) with two coats of synthetic enamel paint upto 1.5 m height above from ground level (in yellow and black strips of 30 cm wide each) and applying two coats of aluminium paint above 1.5 m height of poles and cross arms, bracing, clamps, chanels etc and writing pole number with black synthetic enamel paint complete all as specified and directed.

6

-

-

... More
Supply and Laying and spreading of 40mm graded stone aggregate complete all as specified and directed.

85

-

-

... More
Material & Labour for cutting of vegetation surrounding transformer, two poles, four pole structure at various sub station / E&M installation and remove to a distance not exc 50 mtr all as directed.

2000

-

-

... More
Preventive maintenance for indoor and outdoor type RMU 3 way comprising preventive maintenance activities and repairing the RMU during breakdown / emergency and routine testing all as specified below:- Note:- Quoted rates shall be deemed to include for the following:- (i) Preventive maintenance shall be carried out one time in year. (ii) Contractor shall also responsible for repairing the RMU during any breakdown / emergency. (iii) routine testing shall be carried out once in a year.

3

-

-

... More
(i) RMU of make L&T & Crompton are installed at site. Preventive maintenance, repairing the RMU during breakdown / emergency and routine testing shall be carried out through authorised representative OEM all as specified and directed by Engineer-in-Charge.

-

-

-

... More
(ii) Spare parts required for Preventive maintenance, repairing the RMU during breakdown / emergency will be measured & paid separately as supply & fix in repair. Make of spare part shall be as recommended by the OEM.

-

-

-

... More
(iii) Contractor shall submit necessary documentary evidence that Preventive maintenance, repairing the RMU during breakdown / emergency and routine testing has been performed by the OEM

-

-

-

... More
(vi) RMU any type any way including VCB, load break switch and metering unit will be measured as one unit for payment.

-

-

-

... More
(v) After Preventive maintenance, repairing the RMU during breakdown / emergency RMU shall be tested as directed by the Engineer-in-Charge and test result in triplicate copy shall be submitted to Engineer-in-Charge

-

-

-

... More
(Note: Item no 1 to 58 If any above LT cables and connected itms become breakdown, the contractor shall loacate the problem/fault at site within 12 hours on intimation by JE/Engineer-In-Charge and ensure that the fault and rectified within 24 to 48 Hours , failing which an amount of Rs 200 /- per hour will be recovered as penalrecovery fromany payment due to the contractor after expiry of 48 hours.)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.