Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Sep 2021
Closing Date6 Oct 2021
Tender Amount₹ 38,44,431 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Out sourcing of services for operation of lift at HQ SWAC and MES type IV Accn (Three lifts, 8 passenger-02, 13 passenger-01 of make Thyssen krupp and OMEGA)one semi skilled lift operator in two shift for 08 hrs for operation and maintaining lift panel room, lift car and connected machinery of the lifts, on all days of the week (including Sunday and Holiday), complete all as specified and as directed by Engr-in-Charge.

11

-

-

... More
Notes :- (a) The work shall be carried out in shifts (As mentioned against each item of Sch) contractor shall employ one per shift, the man power detailed in such a way that each Operator get weekly off as per prevelling labour act/ law (b) The entire Lift cabin including machinery, equipments in building premises shall be kept neat and clean and necessary oil, Greesing, Minor Servicing as per manufacturer recommendation (Omega/ Thyssen krupp or as existing) shall be carried out to avoid any mishappning all as directed by EIC. (c) Contractor has to provide the two sets of uniform with MES logo and shoes to all industrial persons who are employed. (d) Operators should be provide hand tools, tester, Meggar or test lamp,safety shoes , hand gloves, sanitizer, Mask, will be provided by the contractor without any extra cost. (e) Rates quoted shall be including minor repair as per daily weekly or monthly check. (f) Electrcity as required shall be made available to the contractor free of cost by department. (g) Emergency light will be provided by the contractor during night hours without any extra cost. (h) All safety precautions as per IE rules should be strictly followed by contracted employees & department shall not be held responsible for any untowards incident.

-

-

-

... More
(j) Attendence Register of Staff Employed will be maintained by JE E/M. If any labour found absent, necessary penalty/recovery will be made at the rate of double of the daily min wages fixed by govt. or the rate quoted by the contractor, whichever is high (k) The contractor should always keep in mind that it is only the services of these contract labours is outsourced & not manpower.So providing reliever will be sole responsibility of contractor. (l) Contractor has to produce Photo ID of the staff employed with security pass number issued by Main Guard Air force Station. (m) GST / EPF paid certificate, attendance of employee etc. shall be enclosed with RAR. (n) The payment to every staff employed on work shall be preferably made in the Aadhaar linked bank account through account payee cheque only and details shall be submitted with RAR.

-

-

-

... More
M&L Comprehensive maintenance /repair and servicing of 13 passenger lift (03 Nos) installation fully comprehensive (i.e All in all) regular maintenance for round the clock, of the lift, including regular servicing, inspections, preventive maintenance by trained technicians and repair of the installation with bear the cost of repair / replacement of any of the worn out part without any additional charges at Type II & Type-III Tower and C-3 Block for 11 month Notes- (i) Six routine maintanance services for oiling & greasing. (ii) Three visit of special lift safety inspection are included in the quoted rates. The following items shall be replaced as & when required under AMC 'A' type contract i.e ("all in all").For OMEGA and Thysen lift as existing at site (iii) Any unserviceable electrical/machenicl parts shall be replaced under AMC without any extra payment. (iv) The rate quoted including services of lifts before AMC

11

-

-

... More
All as per item No 5 above but, for 8 passenger lifts (03 Nos lifts )

11

-

-

... More
Note - for item No 5& 6 : (i) Any required electrical/ machenical parts of above mentioned lifs or any other parts also are to be repair/replaced as & when it become unserviceable as per term & condition of omega/ Thyssen under the AMC 'A' type contract, any cost of material & labour charge will not be paid extra . (ii) Any other material become un serviceable which is not in the scope of AMC 'A' type contract is also to be repaired/replaced timely to run the lift smoothely without any extra payments . (iii) The terms & conditions of this AMC as applicable as given in Annexure I & II by OMEGA and Thysen (iv) The comprehensive maintenance inclusive of inspection/testing/preventive maintenance replacement of unsv parts/material including labour, transportaton. (v)The complaints shall be attended forthwith as the complaints/failure from the time of receipt of same (vi) Contractor shall rectify the defects with in 24 hrs after receipt of complaints , otherwise the complaints will be rectified by the other agency and the expendature incurred will be recovered at Rs 2000/per day till proper functioning of lift. (vii) The schedule A consists of comprehensive maintenance lifts (viii) The load testing of lifts ie 8 passenger and 13 passenger shall be carried out as per standard norms of OMEGA/Thysen and hand over certificate to the department.

-

-

-

... More
Note For particular specification : (a) The work under authorised delear comprehensive maintenance of lifts all as specified in sch A special condition particular specification, MES SSR, latest relevent IS code and as directed by GE/Engr-In-charge. (b) The tender shall have to submit the copy of MOU with authorised dealer to carry out the comparhensive maintenance in a separate envelop attached with the envolpe containing quoted tender documents and failing which the tender will be treated as non- bonafied and will not be considered for opening of the same. (c) Lift mechine shall be well experienced in lift/elevators repairs and maintenance. (d) The contractor shall ensure proper functioning of safty devices.

-

-

-

... More
S&F Fan blower of lift cabin, with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge

7

-

-

... More
S&F Light of lift cabin, with existing make suitable for lift of Thyssen krupp or Omega as per site requirement as in repairs complete all as specified and as directed by Engr- in- Charge

25

-

-

... More
S&F UPS of lift with existing make suitable for lift of Thyssen krupp or Omega as per site requirementc as in repairs complete all as specified and as directed by Engr- in- Charge

6

-

-

... More
S&F Batteries of capacity 12 Volt and 7 AH for UPS device of lift with existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge

22

-

-

... More
S&F Batteries of capacity 12 Volt and 8 AH for UPS device of lift with existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge

8

-

-

... More
S&F Display of lift with existing make suitable for lift of Thyssen krupp or Omega as in repairs complete all as specified and as directed by Engr- in- Charge

28

-

-

... More
S&F MCB SP 'C' type 240 V,50 Hz,10 KA of capacity 6-32 Amp as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charg

5

-

-

... More
S&F MCB SP 'C' type 240 V,50 Hz,10 KA of capacity 40 Amp as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F MCB DP 'C' type 240 V,50 Hz,10 KA of capacity 40 Amp as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

3

-

-

... More
S&F MCB DP 'C' type 240 V,50 Hz,10 KA of capacity 6- 32 Amp as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F MCB TPN 'C' type 240 V,50 Hz,10 KA of capacity 6- 32 Amp as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F MCB TPN 'C' type 240 V,50 Hz,10 KA of capacity 63 Amp as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F MCB isolater FP 'C' type 240 V,50 Hz,10 KA of capacity 100 Amp as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F RCCB 'A' type DP 240 V,50 Hz,10 KA of capacity 25 Amp and 300mA as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F RCCB 'A' type DP 240 V,50 Hz,10 KA of capacity 40 Amp and 30mA as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F RCCB 'A' type FP 240 V,50 Hz,10 KA of capacity 40 Amp and 30mA as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F RCCB 'A' type FP 240 V,50 Hz,10 KA of capacity 40 Amp and 300mA as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-

... More
S&F RCCB 'A' type FP 240 V,50 Hz,10 KA of capacity 25 Amp and 300mA as suitable for lift panel complete as in repairs all as specified and as directed by Engr- in- Charge

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.