Military Engineer Services Tender
... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697278_1Tender No
8793/V/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
LT cable 6 Sqmm , 2 core
250
-
-
... More
LT cable 10 Sqmm , 4 core
250
-
-
... More
LT cable 16 Sqmm , 4 core
610
-
-
... More
LT cable 25 Sqmm , 4 core
640
-
-
... More
LT cable 50 Sqmm , 3.5 core
260
-
-
... More
LT cable 70 Sqmm , 3.5 core
210
-
-
... More
LT cable 95 Sqmm , 3.5 core
200
-
-
... More
LT cable 120 Sqmm , 3.5 core
100
-
-
... More
LT cable 150 Sqmm , 3.5 core
110
-
-
... More
LT cable 240 Sqmm , 3.5 core
140
-
-
... More
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in hard/dense soil ,For laying of pipe/cable/finding out LT cable faults complete all as specified and directed by Engineer-in-Charge.
673.11
-
-
... More
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick complete ,For laying of pipe/cable/finding out LT cable faults complete all as specified and directed by Engineer-in-Charge.
397.13
-
-
... More
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points complete all as specified and directed by Engineer-in-Charge.
275.98
-
-
... More
Material & labour for sand cushioning for UG cables using dry river sand; gently punning down complete all as specified and directed by Engineer-in-Charge ( Note : For measurement purpose punned thickness shall be considered)
201.93
-
-
... More
Material & labour for unreinforced precast concrete cable covers CLASS LV type II, flat size 300 x 180 x 40 mm laid transverse to cable complete all as specified and directed by Engineer-in-Charge
13850
-
-
... More
Material & labour for straight through joint (epoxy) for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing complete all as specified and directed by Engineer-in-Charge for following sizes:-
-
-
-
... More
Cable size 240 to 300 Sqmm, 45 core
4
-
-
... More
Cable size 70 to 120 Sqmm, 3.5 core
10
-
-
... More
Cable size upto 50 Sqmm, 3.5 core
10
-
-
... More
Material & labour for heat shrinkable indoor/ outdoor LT end terminations for LT 1100 Volts grade, aluminum conductor including jointing kits, aluminium ferrules and labour complete for making joints and testing complete all as specified and directed by Engineer-in-Charge for following sizes:-
-
-
-
... More
Cable size 240 to 300 Sqmm 4 core
2
-
-
... More
Cable size upto 70 to 120 Sqmm, 4.0 core
1
-
-
... More
Cable size upto 25 to 50 Sqmm, 4.0 core
1
-
-
... More
Cable size upto 6 to 16 Sqmm, 4.0 core
1
-
-
... More
Supply & fix GI tubing light grade for encasing cables for mechanical protection, laid under plinth/floors/ roads/ path /culverts or fixed on walls/on poles by means of MS FI clamps with necessary bolts, nuts and washers complete all as specified and directed by Engineer-in-Charge for following sizes:-
-
-
-
... More
50mm bore
32
-
-
... More
80mm bore
21
-
-
... More
100mm bore
12
-
-
... More
Supply & fix in replacement MCCB's,415 Volts , fix / adjustable type having complete all as specified and directed by Engineer-in-Charge for following capacities:-
-
-
-
... More
MCCB 4 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA
11
-
-
... More
MCCB 4 Pole, 415 V, fixed type, 125 Amps with breaking capacity 16 KA
7
-
-
... More
MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
7
-
-
... More
MCCB 4 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA
6
-
-
... More
MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
2
-
-
... More
Material & labour for earthing complete with GI earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level connected to and including GI strip of 32X6mm as earth lead up to 7.5 mtr long fixed by means of bolts, nuts, check nuts and washers etc. of galvanised iron or steel including provn of GI protection pipe light grade of 32/40mm bore and connected to earth strip earthing test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore Sch.40, wire mesh and lugs, test point etc. complete all as specified and directed by Engineer-in-Charge.
Note: GI strip exceeding 7.5m long shall be measured & paid seperately.
6
-
-
... More
Material & labour for complete cleaning of the internal & external parts of LT panel; checking & testing of all the components of the panel for cable insulation, lugs, connections and the like; replacement of & including provision of minor parts like lugs, insulation tape, nuts bolts, connectors and the like as directed by Engineer-in-Charge; replacement and / or welding of existing damaged hinges of the panel; preparation of old painted surfaces (internal & external) of the panel, complete removal of existing paint using emry paper grade 220, by sanding and scrubbing, application of corrosion resistant primer by sprayers, applying hammer finish metal paint using sprayers in two coats and till shining surfaces are obtained; application of two coats of epoxy black paint on panel frames; complete all as directed by Engineer-in-Charge.(Approximate average size of panel=1.50x0.75x0.45m) (Note - Rates included for provision of sufficient technicians for getting electric shut down and to attend the shutdown on site till completion. Replacement of major items like MCCBs etc. shall be measured & Paid for separately).
6
-
-
... More
Material & labour for Zebra painting white & sky blue strips 30 cm height in alternate colour strip upto 1.5 meter from top edge of coping of electric poles with synthetic enameled paint two coats and numbering to poles with 80mm size letter with black synthetic enameled paint complete all as specified and directed by Engineer-in-Charge.
45
-
-
... More
Supply & fix FRP juction box of size outside dimensions 350 x 270 x 200 mm with terminals , IP-65/66 protection, 01 Nos MCB SPN C series of capacity 06 Amps as approved by the EIC including connector and fixing on pole with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc. complete all as specified and directed by Engineer-in-Charge
Note:- The cost of junction box installation includes making hole of suitable size for entry and exit of cable upto 35X3.5 Core size, making new lugs of cables of entry and exit.
8
-
-
... More
Supply & Fix FRP juction box of size outside dimensions 250 x 250 x160 mm with terminals , IP-65/66 protection, as approved by the EIC including connector and fixing on pole with and including MS clamps made out of 25 x 3mm MS flat iron, nut, bolts etc. complete all as specified and directed by Engineer-in-Charge
Note:- The cost of junction box installation includes making hole of suitable size for entry and exit of cable upto 95 Sqmm 3.5 Core size, making new lugs of cables of entry and exit.
3
-
-
... More
Supply & fix in replacement of pin type, (LT) porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut,100mm height, 65mm dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
15
-
-
... More
Supply & fix in replacement shackle type procelain, vitreous white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts of 75mm height, 90mm max dia for 1100 volts grade complete all as specified and directed by Engineer-in-Charge.
15
-
-
... More
Supply & fix spacer made out of hard/rigid PVC as approved by Engr-in-Charge on the LT OH line suitable for 4 wire system LT OH ACSR conductor complete all as specified and directed by Engineer-in-Charge.
40
-
-
... More
Material & labour for finding out LT fault in LT O/H distribution system / LT panel/Feeder panel/junction box/TPN BD/OH conductor/MCCB & any type of no power supply complaints with deploying trained electrician and helper seggregate/ isolate the feeder carry out maintenance work such as repair of jumper,insulators ,conneted items and then after charge the feeder with load in presence of Engr-in-charge complete all as specified and directed by Engineer-in-Charge.. Note- Arrangement of tools and labour is the responsibility of contractor.Fault must be rectified within 03 hrs after receiving complaint. If contractor failed to attend/rectify complaint within stipulated perion of time a penalty of Rs 600/- per complaint can be charged
160
-
-
... More
Material & labour for erection of precast LT cable route / cable path indicator,made out of PCC 1:2:4 ,type BO,12.5 mm using graded stone aggregates of size 100 Cm (Height) x 12 Cm (Width) x 8 Cm (Thichness), painted with orange colour lettering synthetic paint and letters 4 inch "LT CABLE" to be written with black colour lettering synthetic paint and embedded in PCC block 1:3:6 type C2 (using 40mm graded stone aggregate) of size 15cm x 15cm x 20cm including necessary excavation for PCC block, placed at interval of every 30 M complete all as specified and directed by Engineer-in-Charge.
22
-
-
... More
Supply & fix fabricating outdoor LT Feeder distribution panel (CPRI Approved) LT electrical distribution panel board floor mounted cubicle type suitable for one incoming MCCB and four outgoing MCCB, one multifunction LED Meter dust proof weather proof vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous 4 strip of copper bus bar 200 amp capacity insulated clour sleeves precilin/ epoxy insulator rai channel cable alloy danger notice board including made out of 14 gauge CRCA Sheet over angle iron frame of size 40x40x6 mm, 30 cm grouted in groung floor and 45 cm above GL including connection with suitable copper cable PVC single core complete all as specified and directed by Engineer-in-Charge.
(i) MCCB 100 Amps 25 KA, 4 pole with adjustable thermal & magnetic setting-01 No (Incoming)
(ii) MCCB 63 Amps 25 KA, 4 pole with adjustable thermal & magnetic setting-05 No (outgoing)
(iii) LED multifunction meter input voltage measurement range 17-520 VAC (P-P) Aux supply 90-300 VAC flush mounting 96 x 96 mm site selectable 1A /5A CT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours etc complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply & fix fabricating outdoor LT Feeder distribution panel (CPRI Approved) LT electrical distribution panel board floor mounted cubicle type suitable for one incoming MCCB and four outgoing MCCB, one multifunction LED Meter dust proof weather proof vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous 4 strip of copper bus bar 400 amp capacity insulated clour sleeves precilin/ epoxy insulator rai channel cable alloy danger notice board including made out of 14 gauge CRCA Sheet over angle iron frame of size 40x40x6 mm, 30 cm grouted in groung floor and 45 cm above GL including connection with suitable copper cable PVC single core complete all as specified and directed by Engineer-in-Charge.
(i) MCCB 200 Amps 36 KA, 4 pole with adjustable thermal & magnetic setting-01 No (Incoming)
(ii) MCCB 100 Amps 25 KA, 4 pole with adjustable thermal & magnetic setting-02 No (outgoing)
(iii) MCCB 63 Amps 25 KA, 4 pole with adjustable thermal & magnetic setting-04 No (outgoing)
(iv) LED Multifunction Meter Input voltage measurement range 17-520 VAC (P-P) Aux supply 90-300 VAC Flush mounting 96 x 96 mm Site selectable 1A /5A CT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours etc complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply & fix fabricating outdoor LT Feeder distribution panel (CPRI Approved) LT electrical distribution panel board floor mounted cubicle type suitable for one incoming MCCB and four outgoing MCCB, one multifunction LED Meter dust proof weather proof vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous 4 strip of copper bus bar 400 amp capacity insulated clour sleeves precilin/ epoxy insulator rai channel cable alloy danger notice board including made out of 14 gauge CRCA Sheet over angle iron frame of size 40x40x6 mm, 30 cm grouted in groung floor and 45 cm above GL including connection with suitable copper cable PVC single core complete all as specified and directed by Engineer-in-Charge.
(i) MCCB 350 Amps 36 KA, 4 pole with adjustable thermal & magnetic setting-01 No (Incoming)
(ii) MCCB 200 Amps 36 KA, 4 pole with adjustable thermal & magnetic setting-03 No (outgoing)
(iii) LED Multifunction Meter Input voltage measurement range 17-520 VAC (P-P) Aux supply 90-300 VAC Flush mounting 96 x 96 mm Site selectable 1A /5A CT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours etc complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply & fix fabricating outdoor LT Feeder distribution panel (CPRI Approved) LT electrical distribution panel board floor mounted cubicle type suitable for one incoming MCCB and four outgoing MCCB, one multifunction LED Meter dust proof weather proof vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous 4 strip of copper bus bar 400 amp capacity insulated clour sleeves precilin/ epoxy insulator rai channel cable alloy danger notice board including made out of 14 gauge CRCA Sheet over angle iron frame of size 40x40x6 mm, 30 cm grouted in groung floor and 45 cm above GL including connection with suitable copper cable PVC single core complete all as specified and directed by Engineer-in-Charge.
(i) MCCB 200 Amps 36 KA, 4 pole with adjustable thermal & magnetic setting-01 No (Incoming)
(ii) MCCB 160 Amps 36 KA, 4 pole with adjustable thermal & magnetic setting-01 No (outgoing)
(iii) MCCB 100 Amps 25 KA, 4 pole with adjustable thermal & magnetic setting-01 No (outgoing)
(iv) LED Multifunction Meter Input voltage measurement range 17-520 VAC (P-P) Aux supply 90-300 VAC Flush mounting 96 x 96 mm Site selectable 1A /5A CT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours etc complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Supply & fix fabricating outdoor LT Feeder distribution panel (CPRI Approved) LT electrical distribution panel board floor mounted cubicle type suitable for one incoming MCCB and four outgoing MCCB, one multifunction LED Meter dust proof weather proof vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous 4 strip of copper bus bar 600 amp capacity insulated clour sleeves precilin/ epoxy insulator rai channel cable alloy danger notice board including made out of 14 gauge CRCA Sheet over angle iron frame of size 40x40x6 mm, 30 cm grouted in groung floor and 45 cm above GL including connection with suitable copper cable PVC single core complete all as specified and directed by Engineer-in-Charge.
(i) MCCB 400 Amps 36 KA, 4 pole with adjustable thermal & magnetic setting-01 No (Incoming)
(ii) MCCB 200 Amps 36 KA, 4 pole with adjustable thermal & magnetic setting-03 No (outgoing)
(iii) MCCB 100 Amps 25 KA, 4 pole with adjustable thermal & magnetic setting-01 No (outgoing)
(iv) LED Multifunction Meter Input voltage measurement range 17-520 VAC (P-P) Aux supply 90-300 VAC Flush mounting 96 x 96 mm Site selectable 1A /5A CT/PT site programmable V, A, F, PF, kW, kVA, kVAR, kWh, kVAh, kVARh, Run hours etc complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
Material & labour for maintenance of ACB 440 Volts,1000/630 Amps including removal of ACB trolley, cleaning of all copper male and female contact, tightening of all connections, checking of all auxiliary contacts, control wiring, etc. refixing the ACB trolley to its original position including proper setting of manual/motorize operation of ACB, checking/setting of tripping system, etc complete all as specified and as directed by Engr-in-Charge.
Note:- (i) Maintenance to be carried out by the reps of companies OEM of companies like C & S, L&T or equivalent
(ii) After completion test certificate shall be furnished from OEM
(iii) Replacement of spare of ACB items to be done in respective items Ser no from 29 to 41.
8
-
-
... More
Supply & fix in replacement of ACB spring charging motor 250 Volts AC/DC (as per site requirment) suitable for AH 10 D 1000/630 Amps with gear assembly complete all as specified and directed by Engineer-in-Charge.
5
-
-
... More
Supply & fix in replacement of CT of suitable ratio for ACBs 1000/ 630 Amps capacity complete all as specified and directed by Engineer-in-Charge.
5
-
-
... More
Supply & fix in replacement of relay suitable for ACBs of 1000/ 630 Amps capacity 440 volts complete all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply & fix TNC switch for operation of ACB as per sample complete all as specified and directed by Engineer-in-Charge.
8
-
-
... More
Supply & fix in replacement of closing coil, ISI marked suitable for 440 V ACB panel complete all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply & fix in replacement of tripping coil, ISI marked suitable for 440 V ACB panel complete all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply & fixing in replacement of Cradle contact ,1000 Amp ISI marked suitable for 440V ACB Panel complete all as specified and directed by Engineer-in-Charge
3
-
-
... More
Supply & fix in replacement of Jaw contact ,1000 Amp ISI marked suitable for 440V ACB Panel complete all as specified and directed by Engineer-in-Charge.
3
-
-
... More
Supply & fix in replacement of under voltage Release 220 volt,AC,1000 Amp ISI marked suitable for 440V ACB Panel complete all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply & fix in replacement of under voltage Release 415 volt,AC,1000 Amp ISI marked suitable for 440V ACB Panel, complete all as specified and directed by Engineer-in-Charge
2
-
-
... More
Supply & fix digital/analog Amp meter with CT suitable for LT panel 0-440 Volts complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
Supply & fix digital/volt meter suitable for LT panel 0-440 Volts complete all as specified and directed by Engineer-in-Charge.
12
-
-
... More
Supply & fix LED lamps for LT panel red, yellow & green complete all as specified and directed by Engineer-in-Charge
16
-
-
... More
Supply & fix LED flood light 100 Watt, IP66 electronic LED driver with IK 07 exclusive die-cast aluminium body with toughened glass visor, open circuit protection, over voltage protection, Surge voltage protection upto 10 kv with built in SPD, lumen LED140 lm/Watt viewing angle 120 degree suitable for highlightening architectural fixed with suitable GI clamps having two coat of enamal paint, Nut Bolts complete all as specified and directed by Engineer-in-Charge.
42
-
-
... More
Supply & fix LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver,lumen LED140 lm/Watt, lamp with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engineer-in-Charge. Note : (For item no 42 and 43)Contractor will arrange T&P and veh required for repairing lights and the cost for the same will be incl in the quoted rate and Lumen certificate of LED lights has to be placed by the contractor,complaint should be rectified with in 04 hrs after handing over of site otherwise suitable penalty will be imposed.
38
-
-
... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 sq. mm 2 core nominal cross section solid conductor in service connections complete all as specified and directed by Engineer-in-Charge.
410
-
-
... More
SStretching of existing aluminium conductor steel reinforced (ACSR) of any size mounting on over head line, properly on insulator with required span and sag including binding with aluminium conductor of 2 mm dia as binding wire complete all as specified and directed by Engineer-in-Charge. (Span=5 conductors of 40m length each)
22
-
-
... More
Material & labour for boring under roads / pavement / hard standing without disturbing the top surface by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure for passing through the cables complete all as specified and directed by Engineer-in-Charge.
Note : Necessary infrastructure required for boring shall be arranged by the Contractor at his own cost.
12
-
-
... More
Cutting and trimming and vending the tree branches along HT over head lines after arranging electrical shout down, including taking all precautions while working on lines using own T&P by the contractor complete all as specified and directed by Engineer-in-Charge. Note:- (i) Branches of trees shall be cut upto 3 m from the outer conductor of OH line.
(ii) Cutting/trimming of branches shall be done after obtaining necessary shut down in writing bt the Engineer-in-Charge to avoid any casualty
36
-
-
... More
Material & labour for cleaning the sub station (the entire sub station to be kept clean by brooming unwanted materials, pulling the unwanted vegetation inside the sub station, bottom of poles, stay assy, cleaning of VCB/ACB/LT cables on site complete all as specified and directed by Engineer-in-Charge. Job shall include thorough cleaning of 40 sub station. Cleaning shall be done once in a quarter for all 40 sub stations.
Note:- Contractor's surpervisor with sufficient labours and an electrician alongwith tools and plants will report to JE in the morning for taking over site of cleaning as ans when direcred by Engineer-in-Charge. The cleaning shall be done upto the satisfaction of Engineer-in-Charge.
1
-
-
... More
Material & labour for finding out LT fault in under ground LT cable with deploying trained electrician and helper seggregate/ isolate the feeder carry out maintenance work such as Excavation of 0.45x0.75 mtr upto 04 RM of length,If further excavation is reqd will be measured in respective item of excavation and Refilling,PCC cover and Sand will be reused ,conneted items Like lugs,insulation tape etc and then after charge the feeder with load in presence of Engr-in-charge complete all as specified and directed by Engineer-in-Charge .
Note- Joint will be measured in respective item.Arrangement of tools and labour is the responsibility of contractor.Fault must be rectified within 04 hrs after receiving complaint. If contractor failed to attend/rectify complaint within stipulated perion of time a penalty of Rs 600/- per complaint can be charged
140
-
-
... More
Material & labour for fabrication of doors /top cover of LT panel/Feeder panel as required in existing LT panel on site by using 3.15 mm thickness mild steel sheeting and painting of fabricated door one coat of red oxide primer and two coat thick enamel paint by matching with the color of LT panel and then after charge the feeder with load in presence complete all as specified and directed by Engineer-in-Charge .
16
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%