Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 18,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_675470_2Bid Award Id
ViewTender No
8138/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR / MAINT OF INTERNAL ELECTRIFICATION, CEILING FAN, ACs, WATER HEATERS ETC AT CGRA AND ICGS STATION UNDER AGE(I)(CG) JAKHAU
REPAIR / MAINT OF INTERNAL ELECTRIFICATION, CEILING FAN, ACs, WATER HEATERS ETC AT CGRA AND ICGS STATION UNDER AGE(I)(CG) JAKHAU
REPAIR / MAINT OF INTERNAL ELECTRIFICATION, CEILING FAN, ACs, WATER HEATERS ETC AT CGRA AND ICGS STATION UNDER AGE(I)(CG) JAKHAU
BOQ Items
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including PVC casing caping complete with all PVC casing caping accessories and flexible conduit etc./ fittings ISI marked and sunk type pressed steel terminal switch box 1.6mm thick with bakelite laminated sheet top cover 3mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories complete all as specified and directed for One light point / fan point / exhaust fan point controlled by one switch.
15
-
-
All as per item No 4.00 above, but for One 3 pin socket outlet 5 Amp on independent board.
8
-
-
All as per item No 4.00 above, but for One 3 pin socket outlet 5 Amp on same board.
4
-
-
All as per item No 4.00 above, but for 2.5 sqmm single core cable for one 3 pin socket outlet 15 Amps on independent switch board including 2.50 Sqmm single core cable as earth continuity conductor and connected to common earth dolly.
4
-
-
S&F switch piano type, flush type, single pole, one way 5 Amps, complete all as specified and directed.
27
-
-
S&F socket outlet 5 Amps, 5 Pin, flush type, complete all as specified and directed.
12
-
-
S&F switch piano type, flush type, single pole, one way 15 Amps, complete all as specified and directed.
4
-
-
S&F socket out let 2 in 1, 3 pin, 5 and 15 Amp flush type complete all, as specified & directed.
4
-
-
S&F in repairs switch piano type, flush type, single pole, one way 5 Amps, complete all as specified and directed.
25
-
-
S&F in repairs switch piano type, flush type, single pole, one way 15 Amps, complete all as specified and directed.
15
-
-
S&F in repairs bell push 5 Amp complete all as specified and directed.
5
-
-
S&F in repairs socket outlet 5 Amps, 5 Pin, flush type, complete all as specified and directed.
15
-
-
S&F in repairs ceiling rose surface bakelite 3 terminals 63.5 x 17 mm.
20
-
-
S&F in repairs door bell ding dong type electric 230 volts AC , single phase, complete all as specified and directed.
10
-
-
S&F in repairs switch socket combination 2 in 1, 5 pin, 5 and 15 Amp flush type complete all as specified & directed.
10
-
-
S&F in repairs stepped type (switch type) electronic ceiling fan regulator flush type, AC, 230 volts , complete all as specified and directed.
15
-
-
S&F in repairs lamp holder PVC / polycarbonate type with back plate complete all as specified and directed.
5
-
-
S&F in repairs Modular switch 1 way 6A, 1 module.
15
-
-
S&F in repairs Modular switch 1 way 15A, 1 module.
5
-
-
S&F in repairs Modular switch 2 way 6A, 1 module.
5
-
-
S&F in repairs Modular bell push, 6A, 1 module.
5
-
-
S&F in repairs Modular Socket 6A, 2 module.
15
-
-
S&F in repairs Modular Socket 15A, 2 module.
5
-
-
S&F in repairs modular fan step regulator, 120W - 2 module.
5
-
-
S&F in repairs modular white cover plate with frame 3 module.
5
-
-
S&F in repairs modular white cover plate with frame 6 module.
5
-
-
S&F in repairs LED batten integrated channel 20 watt with eye soft technology & glarefree diffuser , 50 Hz , 6500K , lumen efficiency greater than 100lm/watt , energy efficient driver, wall mounted complete including connection with flexible cable copper conductor three core of size 23/.2 mm upto ceiling rose/connector and making good of existing wall surface complete all as specified and directed by Engineer - in - Charge.
50
-
-
S&F in repairs LED batten integrated channel 10 watt with eye soft technology & glarefree diffuser , 50 Hz , 6500K , lumen efficiency greater than 100lm/watt , energy efficient driver, wall mounted complete including connection with flexible cable copper conductor three core of size 23/.2 mm upto ceiling rose/connector and making good of existing wall surface complete all as specified and directed by Engineer - in - Charge.
15
-
-
S&F in repairs LED batten integrated channel 5 watt with eye soft technology & glarefree diffuser , 50 Hz , 6500K , lumen efficiency greater than 100lm/watt , energy efficient driver, wall mounted complete including connection with flexible cable copper conductor three core of size 23/.2 mm upto ceiling rose/connector and making good of existing wall surface complete all as specified and directed by Engineer - in - Charge.
10
-
-
S&F in repairs decorative ultra slim square profile LED light 10 watt , energy efficient , efficiency is greate than 100lm/watt , 6500K, , polycarbonate extruded body, including connection with flexible cable copper conductor three core of size 23/.2 mm upto ceiling rose/connector and making good, existing surface complete all as specified and directed by Engineer - in - Charge.
30
-
-
S&F in repairs decorative ultra slim square profile LED light 15/18 watt , energy efficient , efficiency is greate than 100lm/watt , 6500K, , polycarbonate extruded body, including connection with flexible cable copper conductor three core of size 23/.2 mm upto ceiling rose/connector and making good, existing surface complete all as specified and directed by Engineer - in - Charge.
20
-
-
S & F in repairs LED ceiling light fitting driver suitable for 15 to 18 watt LED panel of exisiting make and model complete all as specified and as directed.
30
-
-
S & F in repairs building security light fitting 20 watt, robust heat sink along with IP 66, IK07 , Surge protections, 230 volt 50 Hz AC , incl connecting with three core flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge.
10
-
-
S&F sub main wiring with two run of 4sqmm single core, PVC insulated, unsheathed multistranded copper FRLS cable 1100 volts conductor drawn through PVC casing caping with all accessories and 4 sqmm PVC insulated unsheathed multistranded copper conductor FRLS cable as earth continuity wire complete all as specified and directed. Note:
Two runs of main cable, one run of earth wire and one run of casing / caping will be measured as one unit for payment.
90
-
-
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N, 8 ways, 240 Volts, ISI marked, 200 amps bus bar stove enamelled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
3
-
-
S & F sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
2
-
-
S&F in repairs MCCB 4 pole 63 Amps with breaking capacity 16kA ,Fixed type 415 volts AC Supply complete all as specified and directed by Engineer - in - Charge.
2
-
-
S&F in repairs MCCB 4 pole 160 Amps with breaking capacity 36kA ,Fixed type 415 volts AC Supply complete all as specified and directed by Engineer - in - Charge.
1
-
-
S & F in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp, 240V complete as specified and directed.
5
-
-
S&F MCB SPN 32 Amps, 'C' curve type & 10 KA breaking capacity.
2
-
-
S&F MCB SP 5-32 Amps, 'C' curve type & 10 KA breaking capacity.
8
-
-
S&F in repairs MCB TPN 40 Amps, 'C' curve type & 10 KA breaking capacity.
3
-
-
S&F in repairs MCB TPN 63 Amps, 'C' curve type & 10 KA breaking capacity.
3
-
-
S&F in repairs MCB SPN 32 Amps, 'C' curve type & 10 KA breaking capacity.
6
-
-
S&F in repairs MCB SPN 63 Amps, 'C' curve type & 10 KA breaking capacity.
4
-
-
S&F in repairs MCB SP 5-32 Amps, 'C' curve type & 10 KA breaking capacity.
20
-
-
M & L for earthing complete with galvanised steel 60cm×60cm ×3.15mm electrode burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including and 20×3mm galvanised steel as earth lead by means of bolts,nuts, check nuts and washer etc and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I and as specified or indicated and testing on completion including excavation / earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric , cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, 40 mm bore medium grade GI protection pipe, test point etc. including dismantling old unserviceable earthing complete all as specified and directed.
Note : - The unit rate quoted shall deemed to have included for GI earth strip up to 7.5 mtr.
4
-
-
Dismantling of complete Ceiling fan 1200/1400 mm sweep i.e. down rod with its Canopies, Shackle, Capacitor holding clamp , split pins, unscrewing the body parts of Ceiling fan, taking out stater, burnt winding, ball bearing, gun metal bush etc. complete to carry out the following repairs :- (a) Removing of burnt out fan winding and rewinding of stater with suitable size of Copper enamelled wire, varnishing heating as per manufactures design and directed.
(b) Re-assembling complete Ceiling fan by fixing only serviceable old/new spare parts (i.e) shackle assembly , capacitor holding clamp, capacitor , gun metal bushes, ball bearing, three core flexible Copper cable, down rod and Canopies & split pins complete all as specified and directed to give designed air delivery including greasing, oiling etc all as directed.
55
-
-
All as per item No 51.00 above, but for exhaust fan of sweep upto 300 mm.
20
-
-
Note: for Item No. 51 & 52:
(a) Supply only spare parts found unserviceable / defective will be measured and paid separately under relevant item of BoQ.
-
-
-
Supply only against Item Ser No. 51 & 52 here-in-before the following spare parts :-
-
-
-
Capacitor for fan 2.5 mfd capacity
40
-
-
Ball bearing sealed at both ends of size 6201ZZ /6202ZZ for ceiling fan
55
-
-
Shackle assembly complete with rubber reel, brackets, 3 x nuts & bolts with cotter pin suitable for fixing ceiling fan of any type, sweep and make complete all as specified and directed.
10
-
-
Fan blades (set of 3 blades)
10
-
-
Supply and fix in replacement exhaust fan of sweep 250mm made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding.
15
-
-
M&L for servicing of Split AC 1.5 TR / 2.0 TR complete indoor/outdoor type units means of adding, cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser with use of nylon brushes, cleaning of filter including replacment of insulation of existing copper tubing inlet-outlet, complete all as specified and as directed.
70
-
-
Taking down the following unserviceable parts of Split type Air conditioners 1.5 Ton / 2.0 TR capacity, supply and fixing new spares of existing make and model all as specified and as directed:-
-
-
-
Blower Motor Indoor Type
3
-
-
Fan Motor Out door Type without blades
3
-
-
Fan Blade for outdoor unit
3
-
-
Starting/Running Capacitor 45 to 60 MFD
20
-
-
Air filter for Indoor Unit
6
-
-
S&F in repairs display for Indoor unit of Split type Air conditioners 1.5 Ton / 2.0 TR capacity of existing Make
2
-
-
S&F in repairs remote control (Hand set only) with Battery for Split type Air conditioners 1.5 Ton / 2.0 TR capacity of existing Make
3
-
-
S&F in repairs Universal PCB/PCB Timer electronic switch with sensor suitable for all makes of split AC 1.5 / 2 TR complete with hand set including taking down unserviceable Electronic PCB from existing unit all as directed.
14
-
-
Taking out old unserviceable compressor of Split type AC 1.5 TR capacity and supply & fix new compressor sealed unit as per existing type in position, charging of refrigerant gas R-22/R-32 of required quantity, brazing of discharge and suction line and testing for leak complete all as specified and as directed.
4
-
-
All as per item No 60 above, but for Split Type AC of 2 TR capacity.
3
-
-
M&L for topping up / gas charging with refrigerant gas (R-22/32), Air conditioner window type / split type of capacity 1.5 / 2 TR after vacuuming & leak testing including brazing suction/discharge line and testing complete all as specified and as directed.
30
-
-
M&L for servicing of package type AC 5.5 TR complete indoor/outdoor type units by means of adding, cleaning solution (HCL) or equivalent solution with water. The cleaning of the condenser with use of nylon brushes, cleaning of filter including replacement of insulation of existing copper tubing inlet-outlet if required complete all as specified and as directed.
6
-
-
M&L for topping up / gas charging with refrigerant gas 407C for package type Air conditioner of capacity 5.5 TR after vacuuming & leak testing including brazing suction/discharge line and testing complete all as specified and as directed.
5
-
-
Supply & fix in replacement copper tubing suction and liquid line both from Indoor to out door unit suitable for Split AC 1.5 TR / 2 TR including insulation on copper tubing complete all as specified and as directed.
20
-
-
Supply and fix in replacement condenser coil made up of copper for split AC 1.5 TR complete all as specified and as directed.
3
-
-
Supply and fix in replacement condenser coil made up of copper for split AC 2.0 TR complete all as specified and as directed.
3
-
-
M&L for topping up / gas charging with refrigerant gas 134a/600a for refrigerator of capacity 230/215 Ltr after vacuuming & leak testing including brazing suction/discharge line and testing complete all as specified and as directed.
2
-
-
Taking out the unserviceable compressor from refrigerator of capacity 215/230 ltrs but any make/model, AC 230 volts single phase and supply and fixing same model /capacity sealed new compressor obtained from the factory out let/authorised dealer alongwith test certificate and with one year guarantee card, including soldering of copper pipe, replacement of copper filter single capillary, replacement of foundation rubber pads, nut and bolts and testing on full load complete all as specified and as directed by Engineer-in-Charge.
Note :- Gas charging and gas shall be paid and measured separately under appropriate item of this BoQ .
1
-
-
Supply and fixing in replacement Freezer chest (made out of aluminium) complete with cooling coil suitable for 215/230 Ltrs capacity refrigerator of any make/model including soldering of copper pipe, replacement of nut and bolts complete all as specified and as directed by Engineer-in-Charge.
Note :- Gas charging and gas shall be paid and measured separately under appropriate item of this BoQ .
1
-
-
Supply and fixing in replacement over load protector suitable for refrigerator of any make/model and capacity upto 230/215 Ltrs including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge.
1
-
-
Supply and fixing in replacement thermostat switch with knob, plate and screws for automatic defrosting device suitable for refrigerator of any make/model and capacity upto 230/215 Ltrs complete all as directed by Engineer - in - Charge.
1
-
-
Supply and fixing in replacement Pigmy lamp screw type/pin type, 15 watt, 240 volts AC supply suitable for any type of refrigerator complete all as directed by Engineer-in-charge.
1
-
-
Supply and fixing in replacement Starting Relay assembly suitable for refrigerator of any make/model and capacity upto 230/215 Ltrs complete all as directed by Engineer-in-charge.
1
-
-
Taking out the unserviceable compressor from water cooler of storage capacity 40/80 litres of any make/model, AC 230 volts single phase and supply and fixing same model /capacity sealed new compressor obtained from the factory out let/authorised dealer alongwith test certificate and with one year guarantee card, including soldering of copper pipe, replacement of copper tubing capillary tube, dryer filter, foundation rubber pads, nut and bolts and testing on full load complete all as specified and as directed by Engineer-in-Charge.
Note :- Gas charging and gas shall be paid and measured separately under appropriate item of this BoQ.
1
-
-
Supply and fixing in replacement Copper Condensing coil unit of water cooler of capacity 40/80 litres including erection of the coil in water cooler body and making connection by soldering/brazing/ welding etc. complete all as directed by Engineer-in-charge.
Note :-
Gas charging and gas shall be paid and measured separately under appropriate item of this BoQ .
1
-
-
M&L for topping up / gas charging with refrigerant gas 134a/600a for water cooler of storage capacity 40/80 litres after vacuuming & leak testing including brazing suction/discharge line and testing complete all as specified and as directed.
1
-
-
Supply and fixing in replacement of fan motor 1/20 HP, copper wound, single phase 240 Volts AC supply, suitable for water cooler, including mounting ring/washer/nut bolts and making necessary connections complete all as directed by Engineer-in-charge.
1
-
-
Supply and fixing in replacement of fan blade assembly made of aluminium (metallic) suitable for water cooler of any make/model and capacity complete all as directed by Engineer-in-charge.
1
-
-
Supply and fixing in replacement thermostat switch protector suitable for water cooler of any make/model and capacity including making necessary connections and testing complete all as directed by Engineer-in-charge.
1
-
-
Supply and fixing in replacement relay with over load protector suitable for water cooler of any make/model and capacity including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge.
1
-
-
Supply & fixing in repairs running capacitor 10 mfd suitable for water cooler of any make/model and capacity including making necessary connections and testing complete all as directed by Engineer-in-charge.
3
-
-
Supply and fixing in replacement PVC flexible drain hose pipe 40 mm dia, 2 metre length with adapter and clamping arrangement complete all as directed by Engineer-in-charge.
3
-
-
Taking down electric water heaters (geysers) of capacity 25 litres storage type, disconnecting of electric and water connections, taking out inner tank from outer cover, removing the thermostat switch, geyser element and geyser assembly, cleaning the inner tank with anti scalent solution including thermostat, geyser assembly and heating element, testing the inner tank for any leakage and rectification by soldering / brazing. Re - assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing complete all as specified and directed by Engineer-in-Charge.
28
-
-
Supply and fixing in repair stainless steel inner tank for storage type water heater 25 Litres capacity to match the existing model of geysers complete all as specified and directed by Engineer-in-Charge.
4
-
-
Supply and fixing in repair apparatus plate assembly with PVC rubber ring suitable for 25 litres capacity as per existing size and model complete all as specified and directed by Engineer-in-Charge.
2
-
-
Supply and fixing in repair heating element push type, 1500 watt of suitable shape and size, conforming to ISI with rubber washers, with clamps complete all as specified and directed by Engineer-in-Charge.
8
-
-
Supply and fixing in repair heating element cup type/triangle with thermostat hole 2KW conforming to ISI with rubber washers, with clamps complete all as specified and directed by Engineer-in-Charge
12
-
-
Supply and fixing in repair brass thermostat switch ISI marked suitable for storage type geysers complete all as specified and directed by Engineer-in-Charge.
15
-
-
S & F in replacement, PVC connection wire woven 15mm size with nickel plated brass adapter, both sides threaded, length of 450 mm complete all as specified and directed by Engineer-in-Charge.
26
-
-
M&L for replacement of existing old unserviceable insulation of refrigerant pipes and fixing in proper manner for split type air conditioner up to 2 TR capacity all as specified and directed.
11
-
-
M&L for leak detection in refrigerant system of AC of capacity 2.0 TR/1.5 TR by using nitrogen pressure test, cutting, brazing, making leak-proof the gas system, cleaning, vacuum the gas system and charging suitable gas as required quantity to achieve desired cooling complete all as specified an directed.
15
-
-