Military Engineer Services Tender
... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_697736_1Tender No
8561/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Taking out old hot water pipe and supply and fix hot water pipe of 25 mm dia withstand upto 15 bar working pressure suitable for 100 LPD solar water system complete all as specified and directed.
70
-
-
... More
M&L for fabrication & fixing in position mild steel work for covers, supporting clamps of pipe, ladders,support structure for solar water system mild steel section such as angle, flat, Tee, nut & bolt etc etc, cutting, welding cold or hot drilling holes in any shape or size and fixing arrangement, including painting with two coats of synthetic enamel paint over a coat of red oxide primer complete using steel section of Fe 290 Grade -165 including dismantling of old steel work complete all as specified and directed.
3500
-
-
... More
Taking down old fountain light and supply and fix new RGB LED Fountain light with controller 12 V, 1X12W colourful water proof underwater submersible Fountain lights in RGB Combination of colours, IP 68 complete all as specified and directed.
8
-
-
... More
Material and labour for taking out old pipe in trenches and s&f new pipe trenches ductile iron pipes, socket and Spigot ends, of size DN100 mm dia bore, ISI marked Centrifugally Cast (Spun) Ductile Iron Pressure pipes conforming to IS:8329/2000 classification K-7 rating with nominal wall thickness 6.0mm, suitable for push-on-joint (Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with Bituminous finish coat as per IS:8329/2000 including EPDM rubber joints conforming IS: 5382 of 2018 complete all as specified and directed.
20
-
-
... More
Material and labour for taking up old pipe in trenches and S&F new ductile iron pipes, socket and Spigot ends, of size DN150 mm dia bore, ISI marked Centrifugally Cast (Spun) Ductile Iron Pressure pipes conforming to IS:8329/2000 classification K-7 rating with nominal wall thickness 6.0mm, suitable for push-on-joint (Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with Bituminous finish coat as per IS:8329/2000 including EPDM rubber joints conforming IS: 5382 of 2018 complete all as specified and directed.
10
-
-
... More
Taking down carefully (copper / aluminum) unsv sub wiring complete of any type (batten / surface conduit or concealed) removing material for taking credit and making good the disturbed surfaces of wall/floor or ceiling to match with existing surface and finishing the surfaces with distemper / white washing / colour washing as per existing complete all as specified and directed.
200
-
-
... More
M&L for sub main using PVC insulated and unsheathed multi stranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping/Conduit of suitable size with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as specified and directed of the following sizes of cables:- Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire. Note :2 runs of 2.5sqmm copper cable & 1 run of 1.5 sqmm copper cable and one run of casing & caping shall be measured as one unit
200
-
-
... More
Supply, install, testing & commissioning of reciprocating dosing pump, high pressure,single head, gear motored adjustable dosing pump having output 2 US GPD to 40 US GPD and adjustable to high pressure of upto 100 PSI with accessories including lead tubing, connection, nuts, injection check valve, clay weight and ferrules and 100 litres FRP tank with lid & level gauge along with Agitator and shaft & blade in plastic mounted on tank complete all as specified and directed.
1
-
-
... More
The agitator motor must posses following specifications:
Voltage input 230V,single Phase,50 Hz,900 Rpm of suitable capacity. The accessories in the dosing system must consist of folowing:- (a) Preparation tank i) Water inlet line
ii) Outlet with strainer
iii) Drain
iv) Overflow
v) Conical Bottom for sludge disposal
vi) Port whole with cover
vii) Level Gauge
viii) Agitator:120 watts,900 Rpm single phase flange mounted motor with plastic shaft and impleller
-
-
-
... More
II) Service tank Model no VST 1006 (FRP), capacity 100 ltr, dia 480mm, net height 575mm consist of
a) Water inlet line
b) Dosing pump mounting provision on lid/wall
c) Drain
d) Overflow
e) Level Guage
f) Inspection port.
-
-
-
... More
M&L for connecting pieces one end flanged and other socket or spigot and bell mouth pieces one end flanged other end tapering as bell mouth up to 300mm dia bore of ductile iron complete all as specified and directed.
60
-
-
... More
Excavation in trenches not exceeding 1.5 m wide but not exceeding 1.5 m in depth for foundation etc or for shafts and getting out in soft / losse soil including trimming sides and bottom of trenches complete all as specified and directed.
12.15
-
-
... More
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
1
-
-
... More
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft / loose soil complete all as specified and directed.
11.15
-
-
... More
M & L for earthing with SAFE EARTHING ELECTRODE (S.E.E) conforming to IS :3043-1987 with zinc coated earthing electrode with coating thickness of 100 microns using pipe in pipe technology method with 3 Mtr long, 42mm inner dia and 76mm outer dia GI rod connected with and including 25 mm x 3 mm size GI strip upto 7.5 m, fixing of electrode by boring 150 mm dia hole up to 3.30 meter depth in any type of soil with mechanical apparatus, returning filling with back fill compound (BFC) 25*2 KG compound bags including GI tubing 40 mm dia with necessary fittings light grade as protection to GI strip complete with FRP earthing protection chamber along of size 420 mm x 420 mm at top, 340 mm x 340 mm at bottom, height 210 mm with FRP chamber cover and including FRP Earthing result display board of size 254 mm x 380 mm made out of plastic material showing the information replated to type of earthing, earthing result, due date of testing etc along with fixing stand 610 mm height made of angle iron as per manufactures instruction complete all as specified and directed.
5
-
-
... More
Earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32X6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 1991, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.
15
-
-
... More
Air Force-I Area
-
-
-
... More
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
54
-
-
... More
Returning filling in including spreading, leveling, watering and well ramming in layers, not exceeding 25 cm thick using excavated soil complete all as specified and directed.
30.8
-
-
... More
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
23.2
-
-
... More
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 6 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
250
-
-
... More
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
70
-
-
... More
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified and directed.
50
-
-
... More
Material & labour for 40 mm dia bore GI steel tubing light grade for protection of cable / earth continuity conductor fixed to poles / walls / roof or laid in floors, road, crossing or ducts fixed with clamps, bolts nuts and washer etc including taking down old pipe complete all as specified and directed.
20
-
-
... More
M&L for providing dry river sand as in sand cushioning 18cm before and 5 cm after laying of under ground electric cable, thickness specified in SSR Part -I, including punning down of sand in layer complete all as specified and directed.
Note: For measurement purpose punned thickness of sand only will be considered.
16.2
-
-
... More
Taking down old un reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed.
1333
-
-
... More
Laying only PCC cable cover for LT / HT UG cable, of any description retrieved from item No 25, complete all as specified and directed.
333
-
-
... More
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV, flat of size 250 mm X 150 mm X 40 mm in trenches as protection to LT UG cable complete all as specified and directed.
1000
-
-
... More
S&F LED Street Light fitting 25 watt, system efficiency not less than 100 lumen / watt, IP65 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting including taking down old light fitting of any description complete all as specified and directed.
10
-
-
... More
S&F LED FLOOD Light fitting 70 watt, system efficiency not less than 100 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with unique lens system for enhanced uniform illumination and weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted with silicon gasket for IP 66 protection in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and directed.
8
-
-
... More
S&F LED FLOOD Light fitting 100/120 watt, system efficiency not less than 100 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with unique lens system for enhanced uniform illumination and weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted with silicon gasket for IP 66 protection in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and directed.
20
-
-
... More
S&F LED FLOOD Light fitting 180/ 210 watt, system efficiency not less than 100 lumen / watt, IP66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with unique lens system for enhanced uniform illumination and weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted with silicon gasket for IP 66 protection in cast aluminium housing with SS screws fixed on existing bracket & connecting, including taking down old light fitting of any description complete all as specified and directed.
6
-
-
... More
Taking down carefully (copper/aluminium) submain wiring complete of any type (batten/surface conduit or concealed ) for socket point or power point complete with all fittings such as swiches sockets pendants etc complete and making good distuebed surface of wall,floor or ceiling with plaster of tiles or roof treatment etc and finishing the surface with distemper white washing / colour washing to match with the existing surface complete all as specified and directed.
500
-
-
... More
M&L for sub main wiring using PVC insulated and unsheathed multistranded FRLS copper conductor cable using approved colour code as per IS drawing in and incl PVC casing and capping with all accessories and making good disturbed surfaces of wall, floor or ceiling with plaster and finishing the surfaces with distemper / white washing / colour washing to match with the existing surface complete all as specified and directed.
-
-
-
... More
Using two single core PVC insulated FRLS cable 4.0 sqmm copper conductor multi stranded and 4.0 sqmm copper conductor insulated cable using as earth wire Note : 2 runs of 4.0 sqmm copper cable & 1 run of 4.0 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit
150
-
-
... More
Using two single core PVC insulated FRLS cable 2.5 sqmm copper conductor multi stranded and 2.5 sqmm copper conductor insulated cable using as earth wire Note :2 runs of 2.5sqmm copper cable & 1 run of 2.5 sqmm copper cable in and including 20mm PVC conduit shall be measured as one unit
350
-
-
... More
M&L for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanized steel wire 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore, galvanised iron, medium grade, and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm) with cast iron frame, with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion. Note:- Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
3
-
-
... More
S&F in repairs pole mounted junction box (Street light boxes) weatherproof cabinets IP -65-IK-09 class II with removable chasis and faceplates,lockable door handle, sealable cover, self extinguishing conforms to EN 60439-3, for single phase lighting system, suitable for 6 module with 1 row complete all as specified and directed.
15
-
-
... More
S & F in repairs contactor 25A 2NO , suitable for 230V AC complete all as specified and directed.
3
-
-
... More
S & F in repairs MCB DP 32A DX3 DP , suitable for 230V AC complete all as specified and directed.
3
-
-
... More
Supply, fix in repair digital weekly timer Switch of supply voltage 240vAC, 50/60 HZ complete all as specified and directed.
3
-
-
... More
Supply and fix in repair LED 5 Watt Round (Warm white) spot light based down lighter 24 V complete with inbuilt driver, 50 HZ T-35 'C, 63000 K, complete all as specified and directed.
15
-
-
... More
S & F in repair LED round spot light 3 W (Warm white) capacity, CCT :- 3000 K, working voltage level 220V-240V complete all as specified and directed.
20
-
-
... More
S & F in repair LED round spot light 2 W capacity, CCT :- 3000 K, working voltage level 220V-240V, complete all as specified and directed.
12
-
-
... More
S & F in repair LED panel Light Round type 15 watt (Warm white) cap complete all as specified and directed.
15
-
-
... More
Supply and fix in repair LED 10 Watt round panel light fitting (Warm white) 240 V 50 HZ with inbuilt driver mechanism complete all as specified and directed.
20
-
-
... More
S &F in repair LED candle 6watt (E14 cap) Warm white complete all as specified and directed.
12
-
-
... More
S &F in repair LED candle 3watt (E27 cap) Warm white complete all as specified and directed.
20
-
-
... More
S &F in repair LED bulb 9/12watt, 230 volts suitable for threaded / pin type holder fitment (Warm white) complete all as specified and directed.
60
-
-
... More
Supply and fix LED decorative post of lantern for 360degree indirect light with IP 65 protection, glare free and better uniformity light, cap 40 Watt fittings including all accessories complete fixing accessories fixed in position complete all as specified and directed.
12
-
-
... More
Supply and Fix LED Bollard light fitting 9/10 watt (Warm white/white), inbuilt driver mechanism, robustly designed, IP 65/IK10 protection complete with base plate and provision of wire 2.0m copper conductor from fitting to connection point incl taking down old unsv light fitting complete all as specified and directed.
62
-
-
... More
M &L for servicing / cleaning / maintenance of water fountain by bailing out unclear water and cleaning of tiles inside and outside using suitable descaling agent and allowing fountain to becomes wet, minor repair to pipe and nozzles, gate valves and other connected accessories incl minor repair to under water motor and electrical connection complete all as specified and directed.
5
-
-
... More
M&L for repairing / servicing the monoblock pump set of capacity 3 to 5 HP by dismantling the pump and motor, over hauling of pump by replacing the complete worn out parts such as cast iron impeller ,bearing , water seal, repairing the shaft by machining, welding, grinding, polishing etc, including servicing of electric motor suitable capacity with replacement of worn out bearing for driven and non driven ends, reassembling the pump and motor after servicing and repair and testing on load complete all as specified and directed.
2
-
-
... More
Supply and Fix non integral LED flexible strip light with high brightness for outdoor applications suitable for 15 watt, 4000K, 230 volts complete with fixing arrangement incl taking down old unsv strip complete all as specified and directed.
15
-
-
... More
M&L for dismantling of existing defective induction motor of capacity 3 to 5 HP, three phase, 415 V, 50 Hz, from the foundation, disconnecting the electric connection, coupling pulley, cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with super enamelled solid copper conductor (winding wire) of suitable gauge and size complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and directed.
2
-
-
... More
Supply and fixing in repair recess mounted LED luminaire with full diffuser 36 watt of 2x2 grid for new age work space, powder coated luminaire with minimum 100lm/watt efficiency, 25000 to 50000 working hours and 6500CCT complete all as specified and directed.
12
-
-
... More
Supply and fix in repair round recess mounted LED luminaire with full diffuser 15/16 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6500CCT complete all as specified and directed.
20
-
-
... More
Supply and fix in repair recess mounted LED slim downlight square luminaire with full diffuser 18 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6000CCT complete all as specified and directed.
12
-
-
... More
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz 0.14A suiatble for 18watt LEd downlighter Secondary: constant current DC:300mA with thermal, overload and short circuit protection complete all as specified and directed.
12
-
-
... More
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz 0.055 -0.080A suiatble for 16watt LED downlighter Secondary: constant current DC:300mA with thermal, overload and short circuit protection complete all as specified and directed.
10
-
-
... More
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suiatble for 36watt (2x2 grid) LED recess mounted fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection complete all as specified and directed.
10
-
-
... More
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suiatble for 9/10watt LED bollard fitting Secondary: constant current DC:300mA with thermal,overload and short circuit protection complete all as specified and directed.
8
-
-
... More
Supply and fix in repair round recess mounted LED slim luminaire with full diffuser 24 watt suitable for opearting voltage 220-240VAC and inbuilt driver, powder coated luminaire with minimum 100lm/watt efficacy, 25000 to 50000 working hours and 6000CCT complete all as specified and directed.
10
-
-
... More
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suiatble for 24watt slim downlighter Secondary: constant current DC:300mA with thermal, overload and short circuit protection complete all as specified and directed.
10
-
-
... More
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suiatble for 40watt post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection complete all as specified and directed.
12
-
-
... More
Supply and fix in repair wall mounted Cabinets Made with Metal Textured polyester coating providing excellent corrosion and scratch resistance front door Openable along with inbuilt accessories made as per IP- 55 standard along with (a) inbuilt one two pole contactor of 25 Amp rating make BCH Cat part No :- CPG 216, (b) one nos 32 Amp two pole MCBs (c) one No 32 amp single pole MCB, the box size will be 200 mm x 200mm x 120 mm ( H X W X D) BCH cat No :- BIL - 50000 (d)Digital timer clock type 110-240 VAC 1 C/O Base/DIN 25 ON/OFF Make L & T complete all as specified and directed.
2
-
-
... More
S & F Brass nozzle 25mm tulip / foam jet nozzle threaded with suitable size packing and washers for fountain complete all as specified and directed.
8
-
-
... More
S & F Brass mist nozzles , double threaded socket and washer with suitable size packing and washers for fountain complete all as specified and directed. Note: (i)The size of nozzle shall be as per site requirement. (ii) Contractor shall submit design and get it approved by Engr-in-charge.
4
-
-
... More
S&F butterfly valves of size 40 mm bore ISI marked with iron wheel head screwed both ends for iron pipe and fixed, complete all as specified and directed.
2
-
-
... More
Supply & laying flat three core PVC insulated & PVC sheathed industrial copper cable for submersible pump motors 10 Sqmm 3 core complete all as specified and directed.
25
-
-
... More
Supply and fix LED decorative post of lantern 45 Watt fittings including all accessories completefixing accessories and clamp including 4 metre height black painted glavanized pole, fixed in position including necessary PCC work and execavation as per manufactuer's instruction complete all as specified and directed.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%