Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date8 Jun 2024
Closing Date6 Jul 2024
Tender Amount₹ 25,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in repair LED driver 100W,2600mA suitable for LED light fitting complete all as specified and directed

25

-

-

... More
S&F in repair LED driver 150/240W3000mA suitable for 240 watt LED light fitting complete all as specified and directed

5

-

-

... More
S&F in repair LED bulb 12 watt of colour temp. 3000K having base cap E27 (thread type) suitable for pole light fittings complete all as specified and directed.

20

-

-

... More
M&L for painting of steel dual arm street light poles of height upto 5 mtrs with one coat of oil based (balck shade) paint, durable and long lasting, resistant to UV radiation and chemicals, including necessary preparation of surfaces before painting. complete all as specified and directed.

48

-

-

... More
M&L for maintenance/repair of highmast light of height upto 16 mtr. after safely lowering down head frame lantern carriage accomodating flood lights. Greasing and adequate tightening of all movable parts of base section i.e motor chain, sprockets, shaft of 3 phase elect wintch motor, steel wire rope after removing all rust/stain over surface of equipments by stain remover. Checking all electrical connections of feeder pillar box and replacing defective flood lights, drivers, switchgears, lugs etc before liftinglantern carriage frame assembly in its initial position complete all as specified and directed.Note:- (i) Replacement of defective flood lights/drivers shall be measured and paid separately under relevant items. (ii) Transport and T & P i.e. Ladder, safety items, or any other equipment for repair of high mast light shall be provided by Contractor and cost for the same to be incl in job itself. (iii) Contractor will ensure that periodical check to be done for making good all defects by replacing nuts/bolts/PVC connection etc and keep the light fitting in working condition through out the period of contract.

4

-

-

... More
M&L for fixing MS pully assembly for high mast light of height upto 16 mtr after nesessary cutting/welding work complete all as specified and directed. Note:- (i) Transport and T & P i.e. Ladder, safety items, or any other equipment for replacement/repair of pully shall be provided by Contractor and cost for the same to be incl in job itself.

1

-

-

... More
S&F in replacement MCB Triple Pole and Neutral 40/63 Amps, 415 V ,10KA B curve breaking capacity complete all as specified & directed.

4

-

-

... More
S&F in replacement MCB Single Pole 6 to 32 Amps, 240 V ,10KA B curve breaking capacity complete all as specified & directed.

20

-

-

... More
Disconnecting and taking down security light fitting, brackets from poles of any height and shifting the fitting in other pole by using old brackets and reconnecting the same complete all as specified and as directed. Note : The rate of Nut, bolts if required will be deemed to be included in quoted rate. 2. Service wire and complete bracket will be measured and paid separately under relevant item.

15

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/ loose soil, for laying of under ground electric cable etc complete all as specified

216

-

-

... More
Taking out LT UG cables of any size, by excavation and earth work in any type of soil, removing bricks or PCC cover of any size complete all as specified and directed NOTE:- (i) Excavation, Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separately.

1000

-

-

... More
Relaying old serviceable underground LT cable of any size obtained from item 15 above complete all as specified and directed

300

-

-

... More
Supply and lay, jointing and testing in repairs/replacement of LT cable of size 16 Sqmm 4 core XLPE insulated, armoured, heavy duty with multi stranded aluminum conductors, 1100V grade, laid in trenches / ducts / through GI pipe fixed to pole complete all as specified and directed Note: Excavation earthwork, cable covers, sand cushioning and GI protection pipe shall be measured and paid separately.

700

-

-

... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each complete all as specified and directed

130

-

-

... More
Removing excavated surplus soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified

86

-

-

... More
M & L for river bed sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning/protection to cable including spreading, leveling and get thick 18cm after hand punning complete all as specified and directed

52

-

-

... More
Laying only serviceable un-reinforced precast concrete cable cover class LV, Type 1, flat, of 250 mm x 150 mm x 40 mm obtained from trenches, abetting each other with gap between adjacent slab not exceeding 10 mm over for cable protection complete all as specified and directed.

2000

-

-

... More
Supply & laying un-reinforced precast concrete cable cover, class LV, Type 1, flat, size 250 mm x 150 mm x 40 mm abetting each other with gap between adjacent slab not exceeding 10mm over for cable protection complete all as specified and directed.

3667

-

-

... More
Supply, fixing and testing LT cable jointing kit straight through type heat shrinkable suitable for cable PVC /XLPE insulated armoured heavy duty aluminum conductor 1100 volts grade LT cable of size 3.5/4 core 16 to 50 sqmm and including taking out cable from faulty portion in any situation/position complete all as directed.

15

-

-

... More
All as per srl item No 26 here-in-before but size 3.5 core70 sqmm to 150 sqmm complete all as specified and directed .

6

-

-

... More
Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings IS marked and laid in trenches under roads in drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, pipes of 50 mm bore ,fixed in repair complete all as specified and as directed.

20

-

-

... More
Restretching/ tightening of ACSR conductor of any type and size by disconnecting from insulators from any location complete all as directed. Note:- (i) Proper shut down has to be taken from MES. (ii) T & P i.e. Ladder, safety items, or any other equipment for repair tightening of ACSR conductor shall be provided by Contractor and cost for the same deemed to be included in respective items

5

-

-

... More
S&F steel wire rope 10mm dia grade SS304 fixed to high mast light complete all as directed

190

-

-

... More
S&F in repairs brackets for street light fitting made out of 32 mm dia G.I. Pipe light grade in shape and angle as directed not exceeding 1.5 mtrs in length fixed to pole with suitable size of M.S. clamps made of M.S flat of size 40 mm x 3 mm, 2 Nos, M.S nut & bolt with cup washers and dismantling old rusted/unserviceable bracket with its rusted clamps and nut bolts complete all as specified and directed. Note- Rate of GI Pipe, clamps, flat and nut bolts inclusive in item rate

15

-

-

... More
S&F in repair service wire 1100 volts grade PVC insulated PVC unsheathed cable multi stranded copper conductor of size 3 core 1.0 sqmm complete all as specified and directed.

400

-

-

... More
S&F in repair service wire 1100 volts grade PVC insulated PVC sheathed cable weather proof multi stranded with aluminum conductor of size 2 core 6.0 sqmm complete all as specified and directed.

200

-

-

... More
M&L for Cutting under road/PCC path and passing GI pipe for cable protection and making good as existing complete all as specified and as directed.

20

-

-

... More
Supply and fixing in repair LED street light fitting 60/70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed

75

-

-

... More
Supply and fixing in repair LED street light fitting 100 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.

60

-

-

... More
Supply and fixing in repair LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.

32

-

-

... More
S&F in repair/replacement of auto /manual street light timer nature switch weather proof enclosure made out of UV stabilized, FR grade special molding compound, rust proof, electric sock proof, vermin proof outdoor pole mountable with mounting bracket made out of GI and nut, bolts, washers including cable glands, openable door with 08 kW three phase load with Power contactors 3nos as incoming and outgoing with MCB rating of 32 Amps/phase and circuit wiring of min 16 sqmm including taking down existing switch complete all as specified. Note : Rate of GI clamps, nut bolts included in quoted rate.

3

-

-

... More
S&F in repair/replacement for kiosk box for luminaries, weather proof made out of PVC/HDPE /FRP housing fire retardant, non fusing, shock & rust proof, single piece molded and cover with hinged door, pole mounting type comprising of aluminum TPN bus bar of 60 Amps of minimum size 300x250x150mm, fixed on pole with MS, clamps 30x5mm with necessary nuts, washer including 16 Amp MCB SP for out goining complete all as specified and directed. Note. Rate of TPN bus bar and MS clamp inclusive in item rate

35

-

-

... More
S&F in repair LED Aviation light at overhead tank/Signal tower/Telephone tower or any high rise buildings at any location of Red colour, 230V AC complete all as specified and directed.

2

-

-

... More
Trimming of tree branches touching to over head lines, up to 1.5 mtr distance all around of ACSR conductors of span 30meter to 50 meter of HT/LT feeders and depositing cut branches away from site as directed and clearance of HT/LT pole and sub station premises complete all as specified and directed. Note: (i) Trimming of all branches of trees falling under one span between two pole shall be considered as one span only. (ii) Contractor have to arrange all T&P, safety equipments manpower and vehicle for trimming at different locations. Contractor or his rep has to ensure power shut down of overhead lines before carrying out trimming. Contractor shall be responsible for any lapses/ mishappening occurred due to negligence of safety aspects.

250

-

-

... More
M&L for preparation and painting 04 nos band / strips with blue and white paint alternately all around the HT/LT/Street light pole with synthetic enamel paint at a distance of 30 cm and painting both side for numbering with black enamelled paint and writing LT/PL No on both side of pole with white enamelled paint of complete all as specified and directed .

500

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.