Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 71,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_696901_1Tender No
8560/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Demolition of brick / stone / PCC block masonry built in cement mortar including all quoins, pillars, arches etc. including removal of debris outside MD land, complete all as specified and directed.
1
-
-
... More
Maroom/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled & rammed including watering complete all as specified and directed.
187.5
-
-
... More
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in surface channel and drains, packing under and haunching to hume pipes etc complete all as specified and directed.
20
-
-
... More
M & L for providing precast cement concrete (1:3:6) (using 20mm graded stone aggregate) solid building blocks exe 10 cm thick, in width (with plain or inter locking joints as directed) setting in CM 1:6 in wall or pillars complete all as specified and directed.
53
-
-
... More
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in coping and like weathering slightly round or chamfered angles and throating as directed and including necessary use and wase of formwork complete all as specified and directed.
4
-
-
... More
M&L for Extra for forming fair finished drains or channels 45cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends, etc complete all as specified and directed.
Note : Inner girth only measured.
201
-
-
... More
M&L for rendering 15 mm thick in CM (1:6) on concrete masonry wall surfaces, finishing even and smooth without using extra cement complete all as specified and directed.
285
-
-
... More
Removing excavated rock beyond 50m and upto a total distance 250 mtr and depositing where directed at a level of n.exc 1.5 m above the starting point complete all as specified and directed.
89.5
-
-
... More
Hardcore of broken stone or boulders gauge n.exc 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
8
-
-
... More
M & L for 75 mm thick cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in sub base of floor complete all as specified and directed.
110
-
-
... More
M&L for filling of dry sand as in screed bed for PCC interlocking paver block including spreading leveling, and well ramming complete all as specified and directed.
2
-
-
... More
M&L for machine pressed precast concrete interlocking paver block of approved shape and size of 60 mm thickness, with minimum compressive strength of 35 N/Sqmm (M-35 grade), without correction factor for chamfering, made in rubber moulds with 0.50 mm thick scratch proof lacquer chemical coating on top surface, with grey cement and pigment complete all as specified and directed.
60
-
-
... More
M&L for filleting in any position and to any shape and the section of fillet exc. 25 sq cm but n exc. 50 sq cm in cement mortar 1:4 including all mitres, stops, etc. complete all as specified and directed.
60
-
-
... More
Labour only for laying of old PCC interlocking paver block of any descreption laid & bedded dry including dismantling PCC interlocking paver block complete all as specified and directed.
Note:- Old PCC interlocking paver block retrived shall be used.
50
-
-
... More
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and directed.
13
-
-
... More
M&L for precast cement cocrete cover slabs (1:2:4) type B1 (using 20mm graded stone aggregate) set in CM 1:4 for man holes complete all as specified and directed.
4.5
-
-
... More
M&L for mild steel CRS TMT bars of 10 mm dia and over, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars complete all as specified and directed.
3305
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas depth exc 1.5m and n exc 3m (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out in all kind of soil and disposal of excavated earth lead upto 50 m and lift exc 1.5m, complete all as specified and directed.
19
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator) means over areas depth exc 1.5m and n exc 3m (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out in ordinary rock and disposal of excavated material lead upto 50 m and lift exc 1.5m, complete all as specified and directed.
16
-
-
... More
M&L cement concrete type B2 1:2:4 (using 40 mm graded stone aggregate) as in foundation complete all as specified and directed.
12
-
-
... More
M & L for 150 mm thick, plain cement concrete type B- 2, 1:2:4 (using 40mm graded stone aggregate) as in plinth protection etc, finishing surface even and smooth without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand 1:3 by weight complete all as specified and directed.
(Note : The concrete shall be laid at a stretch n.exc 3.0 m in length and every turning/ corners.)
31
-
-
... More
M&L for formwork to curved sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
13
-
-
... More
M&L for formwork to curved fair faces of walls retaining walls abutments parapets and staircase railing and similar works including attached plaster butresses etc vertical or to batter complete all as specified and directed.
83
-
-
... More
M&L for RCC Design mix M-30, (using 20mm graded stone aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
17
-
-
... More
M&L for RCC (design mix) M-30 (using 20mm graded stone aggregate) in walls basement walls any thickness above top of footing including attached plasters and buttress complete all as specified and directed.
10
-
-
... More
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/disintegrated rock complete all as specified and directed.
129
-
-
... More
M&L for removing excavated soil exc 50m & n.exc 250m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
92
-
-
... More
S&F mild steel framed work such as grills gratings etc with ends of bars shouldered and / or riveted or forged into spikes framed guard bars barred iron doors ladders framed balusters walkways railings framework of water tanks and similar work conforming to Fe 290 Grade E-165 complete all as specified and directed.
361
-
-
... More
M&L for preparation of newly or untreated steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying two coats of Synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
16
-
-
... More
S&F for welded steel wire fabric weight n exc 4 kg per square metre to wood or steel members complete all as specified and directed.
46
-
-
... More
M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortat (1:4) using water proofing compound @ 3% by weight of cement finished even and fair as in sunken floor and wall complete all as specified and directed. Note: WPC will be measured and paid separetely.
68
-
-
... More
Supply only water proofing compound Make - Scott No 1/Sika/Fosroc/Choksey or equivalent conforming to IS-2645 1975 complete all as specified and directed.
40
-
-
... More
Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed.
134
-
-
... More
Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
10
-
-
... More
S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 80mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed.
330
-
-
... More
Supply and fix Sluice valves, flanged of class 1.0 PN, 80 mm size complete all as specified and directed.
4
-
-
... More
Supply and fix non return valve, flanged of size, 80mm size complete all as specified and directed.
2
-
-
... More
Supply & fix Non clog vertical submersible pumps with chrome steel impeller and cutter, non-clog to pass 40 mm size particles including Supply, installation with guide rail and lifting chain, cables, Earthing, testing complete having flow upto 600 lpm and head upto 40 RM antirust coating dynamically balanced impellerfor noise free operation with fittings and wire complete all as specified and directed.
2
-
-
... More
Supply and Fix Star delta Starter fully automatic suitable for 415 V AC Upto 7.5 HP complete all as specified and directed.
2
-
-
... More
Supply and laying or fixing or passing through pipe, 440 volts grade heavy duty cable with PVC insulated COPPER conductor tape and overall PVC sheathed 6 sq. mm 3 core nominal cross section in service connections complete all as specified and directed.
125
-
-
... More
Supply fabricate & fix in position anodised aluminium powder coated (minimum thickness of powder coating 50 micron of approved colour) door shutter with frame, partly glazed with 5 mm thick tinted glass and partly panelled with 9 mm thick prelaminated particle board with both side decorative laminated including rubber bead joining cleat for fixing in position, aluminium door handle 150 mm size, aluminium barrel tower bolt 200 mm size etc all as specified below complete all as specified and directed. (a) Frame (top & side) section shall be of size 101.60 x 44.75 x 2.4 mm (Section No 14021) (b) Vertical Members of shutter section shall be of size 85.00 x 44.45 x 2.00 mm (Section No 19560) (c) Top Members of shutter section shall be of size 83.50 x 44.45 x 2.00 mm (Section No 19581) (d) Lock rail (Middle member) of shutter section shall be of size 150.00 x 44.45 x 3.00 mm (Section No 19596) (e) Bottom Members of shutter section shall be of size 150.00 x 44.45 x 3.10 mm (Section No 19584) (f) Glazing clip for securing glass of shutters shall be of 0.80 mm thick (Section No 19370).
4.5
-
-
... More
Material and labour for 8 to 9 mm thick Pre painted gypsum building boards of size 595 x 595mm PVC laminated at back side of board flat in ceiling fixed or laid / including powder coated GI snap grid of size 605mm x 605mm frame work using 36.50 x 23.50 x 1.5mm main Tee, 23.50 x 23.50 x 1.5mm cross Tee and 25x25x1.5mm angles for false ceiling with screws fixed to false ceiling including hangers 4 mm dia G.I (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. Note: The rate inclusive of scaffolding and necessary arrangements.
32
-
-
... More
M&L for complete removal of existing unserviceable water proofing treatment from top of roof and canopies/chajjas of building including removal of debris outside MD land complete all as specified and directed.
60
-
-
... More
Demolition of cement concrete any description and in any position not otherwise specifically provided for complete all as specified and directed.
3
-
-
... More
M & L for providing plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) of average thickness 40 to 50mm in adequate slope on roof surfaces for padding to achieve the 1:40 slope complete all as specified and directed.
3
-
-
... More
M&L for providing screed bed of 10 to 15mm avg thick in CM 1:4 for laying floor finish, mixed with WPC @3% by weight of cement on fair faces of concrete surfaces without using extra cement as in roof complete all as specified and directed.
Note:- WPC shall be measured & paid separately.
60
-
-
... More
Supply only liquid water proofing compound complete all as specified and directed.
10
-
-
... More
Material and labour for water proofing treatment to slab area with smartcare APP membrane 3.00 mm thick polyester modified preformed membrane mineral finish with the help of torching with side overlap of 100mm to be done over one coat of smartcare bitumen primer apllied with brush/roller laying achieving a forced coverage of 4 sqmt/ltr as per manufacturer's instructions complete all as specified and directed.
60
-
-
... More
Removing building materials (Cement concrete any description, bricks, stone slab and tiles, bricks dust or mud etc) to a distance of 30 km beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified and as directed. Note: All debris and rubbish shall be removed from MOD land during or at the end of each working period at his risk and cost in accordance with all applicable federal, state, and local regulations complete all as specified and directed.
3
-
-
... More
Supply, installation, testing and commissioning of factory assembled diesel Engine driven generating set minimum capacity of 30 KVA duly certified by agencies / lab designated by MoEF/CPCB-IV with latest norms for 3 phase, 4 wire, 415 V, 1500 RPM, 50 Hz power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integrated acoustic enclosures having salient features modular bolted construction with fabrication on imported CNC turrert punch machines, Nine tank treatment process with pure polyester based powder coating to ensure long life in all weather conditions and for out door application / installation. Integrated design thereby facilating/easy handling installation and shifting of the eqpt at site.
1
-
-
... More
The design of integrated acoustic enclosure should be of type approved by National physical laboratory as per central pollution control board (CPCB-IV) latest norms/regulation with fuel tank, battery and standard accessories including cost of PCC (1:2;4) type B-1 foundation for acoustic enclosures foundation as recommended by manufacturer, vibration pad and sand cushioning around PCC foundation etc, all and tools and spares as provided by manufacturer complete incl all as specified and as directed with the following specifications:-
Note: DG set capacity shall be minimum 30 KVA or next higher capacity as manufactured by OEM without any extra cost.
-
-
-
... More
(A) ENGINE : Water cooled with radiator diesel Engine confirming to IS : 10001/10002 of 1500 RPM capacity to match the 30 KVA alternator under NTO conditions with provision of 10% overload for 1 hour in every 12 hours running conforming to IS 6514/ IS 10001 / 10002 the Engine shall consist of the following:-
(i) Fly wheel
(ii) Flexible coupling with guard bolts and nuts etc. (iii) Air cleaner heavy duty dry type (iv) Radiator with guard and water pump engine mounted.
(v) Dynamo of suitable capcity.
(vi) Air cleaner heavy duty dry.
(vii) Fuel injuction pump.
(viii) Radiator fan (Blower type) with guard.
(ix) Electronic A1 class governer.
(x) Fuel filter Mounted.
-
-
-
... More
(xi) Lubricating oil filter mounted.
(xii) 12/24 Volt self- regulating alternator belt driven by engine.
(xiii) Exhaust silencer heavy duty residential type and retrofitting of emission control deivce as per NGT norms.
(xiv) Corrosion resistor / scale inhibitor.
(xv) Starter 12/24 V DC.
(xvi) Lubricating oil cooler.
(xvii) Lubricating oil pump (Gear type).
(xviii) Turbo Charger.
(xix) Exhaust piping shall be insulated with asbastos rope duly cladded with aluminium sheet.
(xx) Instrument panel complete with the following:-
(a) Auto /mannual starting switch with key. (b) Lubricating oil tempreture gauge. (c) Lubricating oil pressure gauge. (d) Water tempreture gauge. (e) Battery charging ammeter. (f) Battery charging indicating lamp. (g) Hour meter with RPM indicator. (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure. (k) Over speed stop with double driven adoptor.
-
-
-
... More
(B) BRUSH LESS ALTERNATOR
(i) Alternator coupled to Engine through a flexible coupling to an indigenous alternator mounted on strong steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be conforming to BS-2613 or relevant IS-13364. (ii) Type :- Self excited self-regulated with automatic voltage regulator. (iii) Rating :- 30 KVA at 0.8 PF lagging 4 pole hozontal at NTP condition 3 (iv) Speed :- 1500 RPM (v) System :- 415 Volts +/- 2.5% AC 3 Phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected. (vii) Enclosure :- Screen protected dip proof. (viii) Ventilation :- Self ventilated (ix) Insulation :- Insulation Class H
-
-
-
... More
(C) AUTOMATIC CONTROL PANEL
Built in AMF panel for automatic ON during power failure and OFF while power is on with adjustable time delay, panel totally enclosed fabricated out of CRCA sheet 3.2 mm SWG, Outdoor type over an angle iron frame made out of 50 x 50 x 6 mm angle with removable side cover hinged front panel and rear panel of easy accessibility complete with internal wiring of suitable size copper conductor cable and cable gland for external connection and comprising of following:- (i) Main in coming MCCB 4 pole 63Amp 415 volts 16 KA- 1No (ii) Panel mounted, flush type 96 x 96 mm size, Digital voltmeter with selector switch - 01 No (Recommended by Manufacturers) (iii) Panel mounted, flush type 96 x 96 mm size, Digital Ammeter (0-200) amps with selector switch with CT - 01 No (Recommended by Manufacturers) (iv) Frequency metre digital type - 01 No (v) HRC type instruments fuse (vi) LED type signal lamp for DG set/ commercial power ON/OFF indication - 06 Nos (vii) Copper bus bar of suitable size. (viii) Circuit diagramed plate
-
-
-
... More
(ix) CT operated KWH metre - 01 No
(x) Power factor meter digital type - 01 No
(xi) Reverse power relays, over current and short circuit protection relay with suitable CTs and suitable contactors, - 01 Set
(xii) Mannual mode, Auto mode, Test mode - 01 set
(xiii) Single phase preventer - 04 Nos
(xiv) Battery charger
(xv) All relays/power contactors of suitable size and capacity Note: Make of AMF panel should be OEM of the DG set only, the safety parameter of the DG set should be incorporated with AMF Panel.
-
-
-
... More
(D) ONE SET OF ACCESSORIES COMPRISING OF :-
(a) FUEL TANK :- One No of sheet steel 14 SWG and capacity to hold diesel sufficient for running 12 Hrs running at full load including necessary piping with the following:
(i) Level indicator on fuel tank
(ii) Drain plug
(iii) MS class 'C' piping for inlet from pump to tank of engine
(iv) Fuel strainer
(v) Air vent.
(b) BATTERY
As recommended by manufacturers
-
-
-
... More
(E) ACOUSTIC ENCLOSURE - Acoustic Enclosure suitable for 30 KVA DG set as under:- (i) Fabricated out of CRCA sheet of suitable thickness not less than 1.6mm. Polyster based powder, coated internaly and externaly with lockable type door handle. All nuts and handles shall be zinc coated. (ii) The door are gasketed with EPDM gaskets. The construction should be such that it prevent entry of rain water splashing in to enclosure and allows free and quick flow of rain water to the ground in the event of heavy rain. (iii) Sound proofing with high quality rock wool/mineral wool confirming to IS 8183 of density at 96 Kg/CUM covered with fiber glass cloth and perforated powder coats sheet specially design alternator (Sound controller) at air entry and exit of the container noise level shall be not exceed 75 Db at 1 meter distance as per CPCB norms. (iv) Adequate ventilation to meet air requirement not for combustion and heat removal with prove of a blower. (v) Emergency stop push button outside the container. (vI) Provision of light inside the Canopy providing of LED fitting 1x20 watt with wiring and control switch. (vii) The canopy should be provided with light enclosure temprature safty device.
-
-
-
... More
(F) BASE PLATE- Sturdy, fabricated welded contruction out of MS channels ISMC of suitable size suitable for fixing of DG set, required anti-vibration mounting pads shall be provided all specified by the manufacturer.
Note: 1. Certifact for compliance of pollution under control as per CPCB-IV norms to be provided by the manufacturer is to be submited. 2. Test cerfitificate by the manufacturer is to be submited. 3. AMF Panel to be certified CPRI, contractor submit to same to the department. 4. DG set load testing to be carried by the competent authority including fuel, T & P, test load and arrangement for the same deemed to be included in above quoted rates. 5. DG set shall be assembeled with sound proof canopy).
-
-
-
... More
Supply, laying, jointed and testing LT cable XLPE insulated, screened, PVC bedded, galvanised steel strip, armoured, heavy duty cable with aluminium conductor, 1100 volts laid in trenches / drawn through pipe or fixed with wall complete of cross sectional area 35 sq. mm 3.5 core complete all as specified and directed.
50
-
-
... More
S&F for flush mounting factory made TPN DBs Double door, IP-43 protection - IK 09 with metal door with neutral busbar, earth bar cables ties for cable management fully insulated busbar 4 Way etc complete all as specified and directed.
1
-
-
... More
S&F MCB Triple pole and neutral, 415 Volts, 63 Amps, breaking capacity, 10 KA, 'C' series etc complete all as specified and directed.
1
-
-
... More
S&F MCB Single pole, 240 Volts, 6 to 32 Amps, breaking capacity, 10 KA, 'C' series etc complete all as specified and directed.
12
-
-
... More
S&F LED Flood light fitting 120W, IP 66 made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection,roadway luminaire with high power LED as light source, with all accessories internally pre-wired etc complete all as specified and directed.
6
-
-
... More
S&F in repair round cable PVC insulated, PVC sheathed, with 3 core copper conductor of size 1.5 Sqmm, ISI marked & connecting complete all as specified and directed.
90
-
-
... More
M&L for submain wiring with two single core 1100 V grade FRLSH PVC insulated flexible copper conductor cable of size 2.5 sqmm and one single core PVC insulated FRLSH flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in & including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces complete all as specified and directed.
20
-
-
... More
M&L for submain wiring with two single core 1100 V grade FRLSH PVC insulated flexible copper conductor cable of size 4.0 sqmm and one single core PVC insulated FRLSH flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in & including a separate concealed PVC conduit medium grade, ISI mark of dia not less than 25mm including cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with adjoining surfaces complete all as specified and directed.
20
-
-
... More
S&F for single pole and neutral enclosure with two pin and earth plug and socket complete with a single pole MCB 20 Amps complete in sheet metal enclosure complete all as specified and directed.
2
-
-
... More
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to galvanized iron strip size 25x4mm as earthing lead by means of bolt, nuts, check nuts and washer of galvanized iron or steel besides welding of all joints as shown in drawing and including excavation and earth work, G.I.pipe light grade 40 mm bore for protection of G.I.strip from earth electrode to and including the earth test point of galvanised iron /steel of size 75 x75x 25 mm , supplying and laying charcoal dust, common salt PCC 1:2:4 type B-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed. Note :- Cost of earthing strip & GI pipe 40mm up to 7.5 m shall be included in cost of above item.
10
-
-
... More
M&L for earthing complete with galvanized steel earth plate 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 Mtr deep below normal ground level) with top edge of plate not less than 1.5 Mtr below normal ground level connected to earth lead wire of GI wire 4mm dia by means of nuts/bolts and washers, check nuts and washer of galvanized iron or steel including 15 mm dia GI pipe mediumt grade upto 1.5 mtr below ground level for protection pipe ,excavation and earth work charcole dust, common salt PCC 1:3:6 type C-I using 20 mm stone aggregate for chamber and MS angle iron frame 40x40x3mm and RCC cover 40 mm thick (1:2:4) type BI using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm c/c both ways with MS handle 12 mm dia, round, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate no 3 of SSR Part I of 2009 and connected to earth test point incl testing complete all as specified and directed. Note :- Cost of earthing wire & GI pipe 25mm up to 7.5 m shall be included in cost of above item.
2
-
-
... More
Supply, Installation / fixing, testing and commissioning of room air conditioner unit of 1.5 TR capacity (Split type unit comprising of indoor and outdoor unit) electric driven (single phase 230 Volt, 50 Hz) and with inbuilt air ioniser and plasma filter for better indoor air quality with minimum BEE 5 star rating and EER 3.2, including necessry fixing arrangements complete (indoor unit at suitable place and height inside the room and outdoor unit at suitable place outside the room) including metallic bracket with fixing bolts for outdoor unit, insulated piping etc. all as specified and directed including taking down old unsv, complete all as specified and directed. Note: (i) Aircoditioner shall be initial filled/charged with refrigerant of specified quanty. (ii) Additional refrigerant pipes required beyond as supplied by manufacturers deemed to be included in AC rate. (iii) Suitable piping shall be provided of adequate length of size 5/8" for draining of condensate water from indoor unit. (iv) Split type AC unit to supplied with cordless remote control for operation. (vi) The condensing unit shall be of copper.
1
-
-
... More
Supply, install and testing 5 KVA wall mounted voltage stabilizer for automatic operation, single phase, naturally air cooled, indoor type & designed for input variation between 170 V to 280 V with output voltage stabilized at 220 with accuracy ± 1% and speed of correction 8 Volts per second and of capacity including taking down old unsv, complete all as specified and directed.
1
-
-
... More
Supply and errect steel tublar swaged poles complete with MS sheet welded on base , finial taper plug, bolts, nuts and screws as specified type 410 SP-64 (12 meters long) including painting with two coats of synthetic enamell paint excavation / earthwork & PCC work will be measured & paid seperately)
4
-
-
... More
M&L for cement concrete in foundations, filing and mass concrete type B2 1:2:4 using 40 mm graded aggregate complete for pole foundation etc complete all as specified and directed.
2
-
-
... More
M & L for cement concrete in filling and massconcrete / coping of poles, type C-2 1:3;6 (using 40 mm graded stone aggregate) complete all as specified and directed.
0.5
-
-
... More
Excavation in any type of soil in trenches not exc 1.5 m wide & not exc 1.5 m in depth and getting out complete all as specified and directed.
3.6
-
-
... More
S&F GI tubing Light grade, ISI Marked conforming to IS 1239 Part-I 2004, 50mm bore with and including all fittings such as bends, elbows, tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches / floor / under culvert / road crossing etc including testing complete all as specified and directed
6
-
-
... More
Supply & fix single pointed air termination aluminium rod 12mm dia, 300 mm dong with all connected accessories and PCC block of suitable size complete all as specified and directed.
4
-
-
... More
S & F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed.
4
-
-
... More
Supply & fix Aluminium strip 25mm x 3.15 mm with saddles and fixing screws for fitting the strip complete all as specified and directed.
40
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%