Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date19 Sep 2024
Closing Date17 Oct 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M & L for dry Sand cushioning to underground cable with screened, washed river sand, including punning gently complete all as specified and directed. Note: - Thickness after punning will be measured for payment.

54.76

-

-

... More
Taking down old unservicable reinforced precast concrete cable cover any type from the trenches etc complete all as specified and directed.

4450

-

-

... More
Laying only PCC cable cover for LT / HT UG cable, of any description retrieved from taking down cable covers complete all as specified and directed.

1450

-

-

... More
Supplying and laying reinforced precast concrete cable cover, class LV Type 2, flat, size 300mm x 180mm x 40mm thick complete all as specified and directed.

3000

-

-

... More
Supply and laying in trenches in road cross / floors tube galvanished iron of size 40mm bore light grade with all fittings for protection of cable complete all as specified and directed.

50

-

-

... More
Supply and laying in trenches in road cross / floors galvanised iron tube of size 50mm bore light grade with all fittings for protection of cable complete all as specified and directed.

60

-

-

... More
Supply and lay in replacement and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 95 sqmm 3.5 core complete all as specified and directed. Note: Excavation & earthwork will be measured and paid separately under respective items of this schedule.

130

-

-

... More
Supply and lay in replacement and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 35 sqmm 3.5 core complete all as specified and directed. Note: Excavation & earthwork will be measured and paid separately under respective items of this schedule.

125

-

-

... More
Supply and lay in replacement and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 50 sqmm 3.5 core complete all as specified and directed. Note: Excavation & earthwork will be measured and paid separately under respective items of this schedule.

100

-

-

... More
Supply and lay in replacement and testing of cable LT XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty with stranded aluminum conductor, 1100 Volts grade, of size 70 sqmm 3.5 core complete all as specified and directed. Note: Excavation & earthwork will be measured and paid separately under respective items of this schedule.

150

-

-

... More
Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 25 sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed. Note: Excavation & earthwork will be measured and paid separately under respective items of this schedule.

150

-

-

... More
Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 16 sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed. Note: Excavation & earthwork will be measured and paid separately under respective items of this schedule.

150

-

-

... More
Supply and laying in replacement XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 11000 volt grade of size 95 sqmm 3 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed. Note: Excavation & earthwork will be measured and paid separately under respective items of this schedule.

40

-

-

... More
Supply, fixing and testing after jointing cable jointing kit for 11 KV grade cable for indoor type end termination heat shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminum cable of size 95 sqmm 3 core complete all as specified and directed.

2

-

-

... More
Supply, fixing and testing after jointing cable jointing kit for 11 KV grade cable for outdoor type end termination heat shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminum cable of size 95 sqmm 3 core complete all as specified and directed.

2

-

-

... More
Supply, fixing and testing after jointing cable jointing kit for 11 KV grade cable for straight through heat shrinkable joint complete with jointing material and accessories suitable for XLPE armoured aluminum cable of size 95 sqmm 3 core complete all as specified and directed.

2

-

-

... More
Serviceing and cleaning of LT panel of any size with oiling, greasing to door panel, welding of broken door with hinges to make it properly fitted, change the unserveciable connector, connection wire and MCCB as required complete all as specified and directed. Note: MCCB will be paid separately

5

-

-

... More
Serviceing of transformer upto 400 KVA/200 KVA at carrying out insulation resistant test (HT-LT, HT-E & LT-E), BDV of oil (top & bottom sample), Filtration & topping up of oil, test, quaterly resistance check of earth pits, arresting of leakage by proper tightening of terminals & joints, replacement of loose or burnt out gasket & proper sealing of valves etc complete all as specified and directed. Note: (i)The cost involved for oil filtration & topping with new mineral oil will be measured & paid separately. (ii) The contractor should produce all testing certificates immediately after testing .Moreover testing should be carried out by authorized OEM only. (iii) Contractor labour working at the substation should immediately inform about any oil leakage, change in colour of silica gel, level down of oil in conservator etc to Engr-in-Charge.

4

-

-

... More
Dehydration / filtration of transformer oil of transformers, of various capacities installed in different locations in KHambhalia and Dwarka by recirculation existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV complete all as specified and directed. Note: Quoted rates shall be deem to include for following:- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete.

500

-

-

... More
M & L for topping up of transformerr oil having dielectric strength 50 KV or so, as per IS specification in various electrical equipment installed at AF Station, Khambhaliya or Dwarka complete all as specified and directed.

200

-

-

... More
S&F in repair electrical insulation matts, Classs "A" size 2x1m, thickness 3.0 mm working grade 3.3 KV, breakdown voltage : 30KV, all other specification confirming to IS : 15652-2006, ISI marked, synthetic mats, fire retardant, blue / black in colour complete all as specified and directed.

6

-

-

... More
S&F in replacement worn out HT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leakage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and directed.

2

-

-

... More
S&F in replacement worn out LT terminal with bush of existing size for transfomers upto 500 KVA capacity to arrest leackage by opening top cover and refixing the same with replacement of worn out gasket complete all as specified and directed.

2

-

-

... More
S&F in replacement breather with accessories of transformer as existing including silca jel complete all as specified and directed.

2

-

-

... More
M & L for servicing of servo controlled voltage stabilizer 300/200 KVA, 415Volt including setting of input and output voltage complete all as specified and directed. Note:- Spare required for replacement if any will be measured and paid separately.

3

-

-

... More
M & L for topping up of voltage stabilizer oil having dielectric strength 50 KV or so, as per IS specification in various electrical equipment installed at AF Station, Khambhaliya or Dwarka complete all as specified and directed. Note: (i) Labour for draining out of oil & refilling the same is deemed to be included in quoted rates. (ii) Cost of minor spares i.e. nut bolt and washer if required to complete the job is deemed to be included in quoted rates.

50

-

-

... More
Supply following spares only for servo controlled voltage stabilizer of 300/200 KVA:-

-

-

-

... More
Shunt trip coil of any size

2

-

-

... More
Cut out PCB,3-phase

2

-

-

... More
Control PCB

2

-

-

... More
Control wire

2

-

-

... More
RC network for 10 KG motor

2

-

-

... More
Sensing transformer for analog control

2

-

-

... More
Stabiliser carbon brush for dimmer

2

-

-

... More
Control wire with glass fuse

2

-

-

... More
S&F in repair digital voltmeter 0-500 volts of size 96x96mm complete all as specified and directed.

6

-

-

... More
S&F in repair digital ampere meter 0-500 A of size 96x96mm complete all as specified and directed.

6

-

-

... More
S&F in repair red / yellow / blue LED indicating lamp (Set of three lamp), 240 volts, AC complete all as specified and directed.

4

-

-

... More
S&F in repair red luminous push button with LED indicating lamp and 1NC element complete all as specified and directed.

5

-

-

... More
S&F in repair green luminous push button with LED indicating lamp and 1NC element complete all as specified and directed.

5

-

-

... More
Taking out u/s LT underground cable of any size 1100 volt grade & bricks, tracing out the defects, rectify the same, making servicable by removing/cutting u/s & burnt out part, jointing with straight through joint of suitable size, testing with megger etc including all associated earth work like excavation / returning filling/removal excavated material and sand filling complete all as specified and directed. Note: Straight through joints will be measured and paid separately.

100

-

-

... More
Relaying of serviceable LT cable retrieved from item No 34 after cutting into pieces serviceable portion of following sizes including all associated earth work like excavation / returning filling / removal excavated material and sand filling complete all as specified and directed.

100

-

-

... More
Material and labour for fixing cable route indicators made of PCC (1:3:6) duly engraved “HT CABLE / HT JOINT LT cable / LT Joint coloured with two coats of synthetic enamel paint in brown of size 150 x 150 x 900 mm fixed 300mm below ground level complete all as specified and directed.

40

-

-

... More
M&L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in to ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth strip 32x6mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.

5

-

-

... More
M&L for earthing complete with galvanised steel earth electrode plate of size 600x600x6mm thick, buried directly in to ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.50m below normal ground level, connected to galvanised iron earth wire 4.0 mm up to test point with suitable GI nuts/bolts and brazed properly up to main board including earth pit in cement concrete 1:2:4 type B-1, precast RCC cover in 1:2:4 reinforced with expanded metal, with suitable handle, excavation and earth work in any type of soil and including medium grade GI watering pipe 25mm bore with funnel wire mesh and medium grade GI earth wire protection pipe 50mm bore up to main board complete as shown in electrical plate no 3 of MES schedule Part-I 2009, connected to earthing testing point including taking out existing unsv earthing complete all as specified and testing on completion complete all as specified and directed.

3

-

-

... More
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot , drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one finishing coat of paint complete all as specified and directed.

5

-

-

... More
M&L for anti climbing devices, comprising 2.24mm dia galvanised steel 2-strand barbed wire with 2.00mm dia barbs wrapped spirally round poles, to a length of 0.5 to 1.0 metre clamped and properly secured or as ordered complete all as specified and directed. Note : Clamps will be measured and paid separately.

3

-

-

... More
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white and writing with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.

4

-

-

... More
M&L for stay assembly complete with accessories as shown in electrical plate No.1 complete all as specified and directed. Note : loop type and concrete will be measured and paid seperately.

2

-

-

... More
M&L for pin type, porcelain,vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron nut, 150mm dia for 11000 volts grade complete all as specified and directed.

12

-

-

... More
S&F lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for HT 11 KV complete all as specified and directed.

2

-

-

... More
S&F switch break gang operated triple pole, mechanically operated, mounted on insulator and steel frame, with operating machanism worked from ground level, for current rating upto 200 Amp suitable for 11000 Volts complete all as specified and directed.

4

-

-

... More
Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.

10

-

-

... More
Supply and fix in repair LED power supply driver suitable for primary : 220-240 VAC, 50/60Hz suitable for 9/10watt LED bollard fitting secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.

10

-

-

... More
Supply and fix in repair LED power supply driver suitable for Primary:220-240 VAC, 50/60Hz suitable for 40watt post top fitting Secondary: constant current DC:300mA with thermal, overload and short circuit protection including taking out old/unsv complete all as specified and directed.

10

-

-

... More
Supply and fixing LED light fitting 1x30 Watt flame proof, CMRI certified recommended for gas / vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.

5

-

-

... More
S&F in repairs of 25 mm bore tube galvanised iron light grade fixed to poles, walls and ceiling etc. with all fittings (clamps for fixing) for protection of cable complete all as specified and directed.

50

-

-

... More
Material & labour for preparation of old painted surface of steel tubular pole (9/11 meter long above coping) or cemented pole and applying two coats of oil synthetic enamel paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint, rewriting pole no by painter with synthetic enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specified and directed.

40

-

-

... More
Material and labour for writing of pole Nos on existing pole with stencil cut with white colour in sky blue colour background of 80 mm height around the radius of pole and complete all as specified and directed.

40

-

-

... More
Supply and fix timer switch digital type 24 hours with 15 min and 30 min, 16/100 Amp contact rating 230 volts AC 50 Hzs suitable for street lights complete all as specified and directed. Make : Legrand Cat Part No.CX3 CT 230V 2NO 40 A or equivalent makes as mentioned in Appx 'B' to PS.

4

-

-

... More
Supply and fixing 3 pole power contactor type ML 2 AC 3 rating (32 A) Aux Contactors 2NO+2NC Cat No SS90701 of Make- L&T compatible with digital timer of suitable capacity complete all as specified and directed.

2

-

-

... More
Supply and fixing 4 pole power contactor type MCX 21 AC 1 rating (100 A) Make- L&T or equivalent suitable capacity complete all as specified and directed.

2

-

-

... More
Supply and fix MCB single pole with neutral, 6 to 32 Amps, 250 volts with ‘B’ curve,10 KA fixed in existing PVC box including connecting complete all as specified and directed.

5

-

-

... More
Supply and fix MCB TPN, 40 to 100 Amps, 250 volts with ‘B, curve,10 KA fixed in existing PVC box including connecting complete all as specified and directed.

5

-

-

... More
Disconnecting the existing unserviceable PVC box and Supply and fix PVC box of outside size 350mm x 250mm x 150mm and inside size 300mm x 200mm x 105 mm including 3 phase connector of suitable amps rating including 1 No MCB SP, 6 to 32 Amps, 250 volts with 'C' curve, to be fixed on pole with clamp complete all as specified and directed.

20

-

-

... More
Dismantling and taking down defective / unserviceable LED street lights fitting and flood lights of any type and of any description and capacity from 09/11 high electric pole and gates complete all as specified and directed.

75

-

-

... More
Supply and fix in replacement 200-210 Watt LED flood light with pressure die- cast aluminium housing, complete with all accessories, energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light with high power LEDs as light source, suitable for highlighting architectural facade highmast and general purpose lighting 200W turbo floodlight luminaires with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion and IP 66 protection fixed in existing clamp and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed. Make : Havells Cat No : LHFPCZBFP46J200), or equivalent make as mentioned in Appx 'B' to PS.

10

-

-

... More
Supply and fix in repair LED street light fitting of 60 W sealed optic luminaire with housing made of die cast aluminium with smooth finish powder coated for better environmental protection complete all as specified below:- (i) The fixture shall be designed so as to have lumen maintenance of at least 70% at the end of 70000 hours. (ii) The luminaire should be operable with auto adjustable 120-240 volt supply using the same driver. Ambient temperature at LED should not be more that 70 degree centigrade. (iii) Power factor of the electronic driver should be at least 0.90 abd efficiency of the luminaire to be more than 85%. (iv) The fixture should be dark sky complaint. The fixture should use aluminium, MCPCB printed circuit boards for better thermal management. (v) The luminaire should throw the perfect amount of uniform lught with exactly the desired intensity, and best pole spacing , along with better light control. (vi) The luminaire shall employ indivdual optical lens for the each of the LED's to ensure better uniformity of light distribution. (vii) The fixute should be vibration resistance, if the fixture is also to be used in vibration prone areas like flyovers/bridges. (viii) Heat dissipation should be managed through a built in external heat sink. (ix) Colour rendering index of minimum 65 with color temprature of 4000K.

55

-

-

... More
All as per Item No 61 above but 35 W light

30

-

-

... More
M & L for repairing the existing LED Streeet light drivers for light model 30/ 60 W NEO K by taking down the unserviceable LED street light drivers from the street light and repairing / replacing the unserviceable parts of drivers like internal wiring etc and refitting the same with all connection after making serviceable complete all as specified and directed. Note : Drivers to be paid saperately.

20

-

-

... More
Supply and fix in repair PVC insulated FRLS copper conductor wire of 2 core 1.5 sqmm from existing sintex box to light fitting complete all as specified and directed.

100

-

-

... More
Taking down of unserviceable high mast street light fittings of any type, any description and of any capacity upto 16 metre high steel tubular high mast electric pole complete all as specified and directed.

10

-

-

... More
Supply and laying in repair XLPE insulated PVC inner sheathed, armoured with galvanised steel strip or wire heavy duty underground cable with aluminium multi stranded conductor 1100 volt grade of size 10 Sqmm 2 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing complete all as specified and directed. Note : Excavation & earthwork will be measured and paid separately under respective items of this schedule.

120

-

-

... More
S&F glow sign board of size 1.5 m x 0.9 m x 0.20 m made out of 1.0 mm thick tin sheet all side except front side aluminium beading "L" shape at all boarder exterier and interier side, front should be acrylic cover 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-charge in english capital letter in white colour with twin tubelight fitting 1x28 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm (length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing complete all as specified and directed.

1

-

-

... More
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 120 Sqmm 3.5 core complete all as specified and directed.

2

-

-

... More
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 95 Sqmm 3.5 core complete all as specified and directed.

2

-

-

... More
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 70 Sqmm 3.5 core complete all as specified and directed.

2

-

-

... More
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 50 Sqmm 3.5 core complete all as specified and directed.

2

-

-

... More
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 35 Sqmm 3.5 core complete all as specified and directed.

2

-

-

... More
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 25 Sqmm 4 core complete all as specified and directed.

2

-

-

... More
S&F in repair cable jointing kit epoxy type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 10 Sqmm 2 core complete all as specified and directed.

2

-

-

... More
M&L for colour coding of earthing pit cover with the following colours: red for chemical earth pit & yellow for conventional earth pit.The numbering/marking of earth pit will be in capital black colour & is to be done complete all as specified and directed.

10

-

-

... More
Supply and erect in true vertical position prestressed concrete pole, 9.0 metres long. of size 102mm x 152mm at top and 102 mm x 289mm at bottom class 10 complete all as specified and directed. Note: (i) PCC foundation & coping shall be measured & paid separately. (ii) Excavation earth work and PCC will be measured and paid for seperately under respective item of schedule "A".

10

-

-

... More
M&L for plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of poles complete all as specified and directed.

0.54

-

-

... More
M&L for cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in benching, coping, including weathering slightly rounded or chamfered angles complete all as specified and directed.

1.08

-

-

... More
M&L for plain cement concrete 1:3:6 type C-2 (using 20mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundation of stay assembly complete all as specified and directed.

5.2

-

-

... More
Disconnecting the existing unserviceable MCCB of 63 A capacity, taking out from the panel board and supply and fix new MCCB four pole of 63 Amps, 25 KA breaking capacity as per site requrement, exiting capacity suitable for 415 Volt, 50 Hz, 4 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

1

-

-

... More
Disconnecting the existing unserviceable MCCB of 100 A capacity, taking out from the panel board and supply and fix new MCCB four pole of 100 Amps, 25 KA breaking capacity as per site requrement, exiting capacity suitable for 415 Volt, 50 Hz, 4 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

1

-

-

... More
Disconnecting the existing unserviceable MCCB of 125 A capacity, taking out from the panel board and supply and fix new MCCB four pole of 125 Amps, 25 KA breaking capacity as per site requrement, exiting capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

1

-

-

... More
Disconnecting the existing unserviceable MCCB of 200 capacity, taking out from the panel board and supply and fix new MCCB four pole of160 Amps, 35 KA breaking capacity as per site requrement, exiting capacity suitable for 415 Volt, 50 Hz, 3 phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolts and washer etc complete all as specified and directed.

1

-

-

... More
Supply and installation, testing, commissioning outdoor type cubical type LT Panel made out of 3.0mm thick CRCA sheet, 415 Volt, 3 phase, 50 HZ supply factory made of MS angle section 40 x 40 x 5mm frame with front and back openable double door with provision of locking arrangement dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specified and directed & Consisting of the following accessories:- (A) Incomimg: (i) MCCB 350 Amps,icu-35 Ka,4 pole,415 v-01 Nos (ii) phase indication lamps LEd type RYB including holder with 0.5 A MCB -01 set of three (iii) Voltmeter digital square type 0.500 V with selecter switch.01nos (iv) Ampere meter digital square type 0.250 amps with selecter switch inclu set of diacast Cts of suitable ratio complete-01nos (B) Bus bar Electrolytic high conductivity aluminium busbar of appropriate cross sectional area -04nos (RYB phases-03nos and Black -01 for neutral). (C) Outgoing: (I) MCCB 100 Amp,Icu-25 KA, 3 pole, 415 volts - 06 Nos. Note: (i) PCC 1:2:4 for grouting included in the total cost of Panel (ii) Excavation and earth included in total cost (iii) Necessarty lugs for cable fitment included in total cost of panel (iv) FRLS copper conductor cable of suitable size shall be used for Control wiring for LT panel complete for incoming/outgoing.

4

-

-

... More
Supply and installation, testing, commissioning outdoor type cubical type LT Panel made out of 3.0mm thick CRCA sheet, 415 Volt, 3 phase, 50 HZ supply factory made of MS angle section 40 x 40 x 5mm frame with front and back openable double door with provision of locking arrangement dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specified and directed & Consisting of the following accessories: (A) Incomimg:(i) MCCB 400 Amps, icu-35 Ka,4 pole,415 v-01 Nos (ii) phase indication lamps LEd type RYB including holder with 0.5 A MCB -01 set of three (iii) Voltmeter digital square type 0.500 V with selecter switch.01nos (iv)Ampere meter digital square type 0.250 amps with selecter switch inclu set of diacast Cts of suitable ratio complete-01nos (B) Bus bar Electrolytic high conductivity aluminium busbar of appropriate cross sectional area -04nos (RYB phases-03nos and Black -01 for neutral). (C) Outgoing:(I) MCCB 100 Amp,Icu-25 KA, 3 pole, 415 volts - 08 Nos. Note: (i) PCC 1:2:4 for grouting included in the total cost of Panel (ii) Excavation and earth included in total cost (iii) Necessarty lugs for cable fitment included in total cost of panel (iv) FRLS copper conductor cable of suitable size shall be used for Control wiring for LT panel complete for incoming/outgoing.

1

-

-

... More
Supply and installation, testing, commissioning outdoor type cubical type LT Panel made out of 3.0mm thick CRCA sheet, 415 Volt, 3 phase, 50 HZ supply factory made of MS angle section 40 x 40 x 5mm frame with front and back openable double door with provision of locking arrangement dust & vermin proof, gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof duly spray painted inside and outside of panel with one coat of red oxide primer and two coat of synthetic enamel paint grey complete all as specified and directed & consisting of the following accessories: (A) Incomimg: (i) MCCB 200 Amps, icu-35 Ka, 4 pole, 415 v-01 Nos (ii) phase indication lamps LED type RYB including holder with 0.5 A MCB -01 set of three (iii) Voltmeter digital square type 0.500 V with selecter switch.01nos (iv) Ampere meter digital square type 0.250 amps with selecter switch inclu set of diacast Cts of suitable ratio complete-01nos (B) Bus bar Electrolytic high conductivity aluminium busbar of appropriate cross sectional area -04nos (RYB phases-03nos and Black -01 for neutral). (C) Outgoing:(I) MCCB 100 Amp,Icu-25 KA, 3 pole, 415 volts - 04 Nos. Note: (i) PCC 1:2:4 for grouting included in the total cost of Panel (ii) Excavation and earth included in total cost (iii) Necessarty lugs for cable fitment included in total cost of panel (iv) FRLS copper conductor cable of suitable size shall be used for Control wiring for LT panel complete for incoming/outgoing.

3

-

-

... More
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 25 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3 mm thick CRCA sheet, 415 Volt, 3 phase, 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof, gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated including taking down old AMF panel complete all as specified and directed & consisting of the following equipments:-

2

-

-

... More
(i) 40 Amp, 4 pole contactor for alternator with thermal over load relay. (ii) 40 Amp, 4 Pole contactor for mains supply. (iii) MCCB of suitable rating for short circuit protection. (iv) Microprocessor based AMF Module incorporating: (a) Supply Failure Timer (b) Restoration Timer, (c) 3 Impulse automatic engine Start / Stop logic & engine fails to start lockout. (d) Mains / Generator voltage & frequency sensing. (v) PCC 1301 controller with the following features: (a) Water temperature / oil pressure. (b) Voltage / Ampere / Frequency / KW / KVA. (c) Running hour counter. (d) No of Starts.

-

-

-

... More
(vi) Fault Indication (LED Type) for following measures: (a) Over / Under speed (b) fails to start (c) Low Oil pressure (d) High engine temperature (e) Under / Over voltage (f) Over current. (vii) Combined Meter for KW / Power Factor / KVA (viii) Electronic kWH Meter (ix) Current Transformers (x) Electronic type earth fault relay (xi) Indications (LED) for DG ON, Load on DG, Mains ON, Load on Mains, Battery charger ON (xii) Following Push Buttons for AMF Module by Pass mode; (a) Generator Contactor CLOSE / TRIP. (b) Mains Contactor CLOSE / TRIP. (c) Fault ACCEPT / RESET. (xiii) Battery Charger.

-

-

-

... More
Taking out the transformer of capacity 200 KVA any type from CSS with disconnection of HT and LT cable, bus bar, earth connections, unscrewing fasteners and by opening upper and side cover carefully of package/ compact substation and transporting the same from site to workshop, testing and diagnosing of fault, opening the top cover, decanning of transformer oil, taking out core assembly after removing HT/LT side bushing connection and asses the damage. Replace the reqd unsv coil of healthy coil (quoted rate of this items not includes cost of copper/ aluminium coil), replacement of insulating material,ovening in suitable furnace and refixing of reconditioning core assembly making all the connection for HT/LT side including connection of tap changer switch,refilling of dehydrated/new transformer oil and the transformer for its efficient working.Transporting back the transformer from workshop to site and re installed the transformer at its location, making all the connection HT/LT side including earth connection and testing and commissioning of transformer on load. Quoted rates includes following:- (a) Transportation of transformer from site to workshop and back to site after making necessary rewinding. (b) Taking down and refixing of the transformer at site. (c) Any required T&P labour including crane & vehicle for shifting of transformer. (d) Contractor shall arrange visit of E/M officer deputed by Accepting officer for strip/winding inspection of transformer before and after making out repairs for joint assesment of involved repairs and testing of transformer at workshop.

1

-

-

... More
Material and labour for rewinding of burnt / over heated HT/ LT limbs of transformers 11 KV/ 433 volts, 3 phase of capacity 50 to 250 KVA by using double paper covered (DPC) insulation, cotton tape, superior quality insulated copper wire of suitable gauge, size, specification complete all as specified and directed.

100

-

-

... More
Material & labour for spray painting of transformers of capacity 150 KVA to 400 KVA of any type & make at any location with two coats of synthetic enamel paint (smoke grey) after thoroughly cleaning of dust, scale, grease, dirt and other foreign material and removing of existing paint and preparation of surfaces including writing of capacity and SM No./ MES No. on transformers complete all as specified and directed.

4

-

-

... More
M&L for alternative arrangement by hiring, transportation of transformer of capacity 200/400 KVA in place of unserviceable transformer on hire basis for 20 days including, installation, connecting and testing of transformer and return back after installation of repaired transformer complete all as specified and directed. Notes: (i) Contractor must arrange hired transformer including transportation and installation at site immediately after receipt of verbal / telephonic / written complaint from JE/Engr-in-Charge within 1 day. Any delay beyond 1 day post receipt of complaint shall be penalized @ Rs 3500/- per day and shall be recovered from next due RAR. (ii) Repairing of transformer must be completed within 20 days after receipt of verbal / telephonic / written complaint from JE / Engr-in-Charge. In case of any delay, no extra claim will be entertained towards hiring charges beyond 20 days and the contractor shall not be allowed to shift the hired transformer until replaced by repaired transformer. In case of any kind of fault / defect occurred in hired transformer, the contractor shall have to arrange further replacement without any additional cost and shall repair the defect from his own expenses. (iii) Contractor should check the available infrastructure and to be sure regarding safety of hired transformer before installation. The rate quoted is deemed to be including transportation cost, earthing lead etc. Note: Arrangement of transfomer and restoration of power supply should be done within 06 hrs from intimation further delayed in restoration after that will be charged Rs 500/- per hour to the contractor.

1

-

-

... More
M & L for locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE HT underground power cables of the rating 11 KV with the help of pre-locator with time domain laptop based reflectometer / electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of faut location necessary excavation and taking out of faulty cable for repair / replacement of joint, relaying of cable / cover & brick protection, refilling of soil and removal of surplus soil complete all as specified and directed. Note: The joint shall be measured and paid separately under relevant item. The qty of item will be executed at different times during currency of contract as directed by Engr-in-Charge. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly. Note: Fault should be detected and rectified within 24 hrs from intimation to contractor after that penalty should be made to contractor at the rate of Rs 500 per hour.

3

-

-

... More
Servicing of ring main unit (RMU) 2/3 way 11 KV by taking shut down and disconnecting electrical connections, removing of dust with blower, cleaning of all movable/fixed parts, removing moisture/ hard carbon deposited due to flash over on bus bars and insulators with CRC/ Stanvac moisture/ carbon remover, checking all components, insulators/ studs, adjusting the male / female bushings in proper spacing, lubrication of moving parts, greasing all parts, tightening nuts and bolts, adjustment of breajer mechanism/ load break switch , earth switch to ensure slip free operation, testing of CT & PT with injection kit and reconnecting of all electrical connections, testing of RMU for healthiness and proper functioning and submitting report complete all as specified and directed. Note: (a) Contractor shall submit complete report regarding CT & PT, Protection relay functioning pick up current & corresponding time value setting tests carried with injection testing kit, Relay testing kit. Any major Spare replaced shall be measured and paid seperately.(b) The service shall be carried out by OEM/HIS REP/Channel partner/service centre/qualified service engineer or reputed firm after approval from Engr-in-charge.

3

-

-

... More
Material and labour for charging of SF6 gas in 11KV RMU 2/3 way, CSS, SF 6 breaker 66KV at site complete all as specified and directed.

25

-

-

... More
Material and labour for replacement of spring charging motor of suitable AC/DC voltage rating for 11KV RMU 2/3 way of series FBX2025 / FBX1844 or VCB existing at site complete all as specified and directed.

1

-

-

... More
M&L for repair of RMU 11 KV 2/3 way any type & any make (ABB, C & S or any other make) complete including removing / disconnecting electric cable and earth connections from RMU, shifting the RMU through suitable transport to OEM / authorized manufacturer / service centre workshop at Chandigarh / Delhi or other loc and opening / step opening of RMU parts and diagnosing the fault complete including making necessary repairs, replacing complete defective AC & DC circuit control protection wiring, complete cleaning, servicing and replacing major defective parts and re-fixing, assembling and replacing parts for satisfactory functioning and shifting back to installation, commissioning and making electrical connections complete all as specified and directed. Note: The major spares replaced shall be measured under relevant items of Sch. Nothing shall be paid extra on account of any freight, transportation, lifting or T&P charges in r/o item.

1

-

-

... More
M&L for Support bushing insulator suitable for 12 KV RMU

3

-

-

... More
M&L for epoxy resin cast HT bushing with stud to be fix on SF6 gas chamber incl vacuumising chamber and refilling of gas after fixing HT bushing

4

-

-

... More
M&L for extensibility kit complete with 3 No extension connectors & 3 Nos Adaptors

1

-

-

... More
M&L for HT Electric fuse for RMU upto 12KV

1

-

-

... More
M&L for earth switch assy for RMU

1

-

-

... More
M&L for load break switch assy 12KV for RMU

1

-

-

... More
Vaccum circuit break switch 12 KV for RMU

1

-

-

... More
M&L for battery 12V, 20 Ah min for RMU

1

-

-

... More
battery charger 12V/24V for RMU as per existing one

1

-

-

... More
M & L for brass stud for RMU / VCB

10

-

-

... More
M&L for Self powered relay DPX-V5 suitable for operation of RMU.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.