Military Engineer Services Tender

Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Jan 2025
Closing Date25 Jan 2025
Tender Amount₹ 75,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Preventive maintenance including servicing of AHU's/CSU's of Make:- Zeco, including servicing /cleaning of pre filter/fine filter pads completely by removing from AHU's/ CSU's and making dust free by air pressure/watering, drying and refixing the same to its postion including checking and serviceability of dehumidifier, fan belt, tightness, servicing of blower motor complete. Servicing shall be carried out quaterly bases or 4 times in a year or contract period complete all as specified & directed by Engineer-in -charge :- Note : The following work are included in the preventive maintenance :- (i) Servicing of cooling coils and air filter of AHU's/CSU's with air blower, water and cleaning agent, cleaning of cooling coil with wire brush / chemical suitable for aluminium fins , cleaning of bottom tray , drain pipe complete (4 time in a year or contract period) (ii) The time interval between two servicing will be intimated by Engineer -in-charge as per requirement (iii) The complete report wrt. each Comprehensive / Preventive maintenance shall be submitted to Engineer -in-charge before payment. (iv) One coat of painting with synthetic enamel paint after rubbing of existing surface and applying one coat of primer inside and outside complete. (once in a contract period for rusted iron surface) as directed by Engr-in-charge. (v) Cleaning/replacement of u/s Valves of any size. (vi) cleaning/repalcement of U/S of Y-Stainers. (vii) Checking/ repairing of control panel wiring if reqd. (viii) Checking & replacement of contactors, relay, MCB/MCCB's of any size , VFD etc complete all as per site reqmt . (ix) All other necessary parts which are not specified but reqd to run the AHU/CSU's and cost of spare parts/ items incl T&P are deemed to be included in the quoted rates.

-

-

-

... More
(a) Building No B1, B2 & B3 - (24 Nos CSU's in each bldgs=72 Nos CSU's ) of capacity 3 TR, 1200CFM, 1HP Motor complete all as specified and directed by Engr-in-Charge Note:- For the purpose of payment Preventive maintenance icluding servicing all the 72 Nos CSU's on one occassion, shall be counted as one job .

4

-

-

... More
(b) Building No B4 (A & B) = 04 Nos AHU's each of capacity 25 TR, 8000 CFM (7.5 HP blower motor) complete all as specified and directed by Engr-in-Charge. Note:- For the purpose of payment Preventive maintenance including servicing all the 04 Nos AHU's on one occassion, shall be counted as one job.

4

-

-

... More
(c) Building No B4 (A & B) = 02 Nos AHU's each of capacity 15 TR, 5000 CFM (5HP blower motor) complete all as specified and directed by Engr-in-Charge . Note:- For the purpose of payment Preventive maintenance icluding servicing all the 02 Nos AHU's on one occassion, shall be counted as one job.

4

-

-

... More
(d) Buildig No B5=02 Nos AHUs each of capacity 30 TR, 12000 CFM, 10HP blower motor complete all as specified and directed by Engr-in-Charge. Note:- For the purpose of payment Preventive maintenance including servicing all the 02 Nos AHUs on one occassion, shall be counted as one job.

4

-

-

... More
M&L for Preventive maintenance including servicing of Make:- Rapid cool Hot water generatore (Total -2 Nos ) of 90 KW capacity complete by opening the existing assembly and drain out complete water, cleaing the container, checking / replacement of u/s heating element, pressure gauge etc and resembling the same and testing after servicing complete all as specified and as directed. Note:- For the purpose of payment Preventive maintenance including servecing all the 02 Nos Hot water Generatore on one occassion, shall be counted as one job.

4

-

-

... More
M&L for Preventive maintenance including servicing of Make:- Rapid Cool Hot water Generatore (Total -2 Nos ) of 45 KW capacity complete by opening the existing assembly and drain out complete water, cleaing the container, checking/ replacement of u/s of heating element, pressure gauge etc and resembling the same and testing after servicing complete all as specified and as directed. Note:- For the purpose of payment Preventive maintenance including servecing all the 02 Nos Hot water Generatore on one occassion, shall be counted as one job.

4

-

-

... More
M&L for Preventive maintenance including servicing of Make:- Rapid cool Hot water generatore (Total -1 No ) of 30 KW capacity complete by opening the existing assembly and drain out complete water, cleaing the container, checking / replacement of u/s heating element, pressure gauge etc and resembling the same and testing after servicing complete all as specified and as directed. Note:- For the purpose of payment Preventive maintenance including servecing all the 01 No Hot water Generatore on one occassion, shall be counted as one job.

4

-

-

... More
Notes above Item No 3 to 5 for Hot water generators:- The following are included in the preventive maintenance of Hot water generators:- (a) Servicing of Hot water generator (4 times in a year or contract period) (b) Replacement of u/s Heating element / pressure guage, switches etc as per site. (c) Rewinding/replacement of Motor of any size as per site reqmt. (d) Repairing of control panel wiring as per site reqmt. (e) Replacement of u/s contactors, relay, MCB/MCCB of any size and capacity, display controller etc complete as per site requirement all as directed by Engr-in-Charge . (f) Rate of above mentioned items incl T&P are deemed to be included in the quoted rates.

-

-

-

... More
Supply only belts of size A-24 of CSU's Blower motor of AC plant any type all as directed by the Engineer-in-Charge.

40

-

-

... More
Supply only 'V' belts of size A-34/38 of AHU,s motor of AC plant any type all as directed by the Engineer-in-Charge. .

10

-

-

... More
Supply only 'V' belts of size B-56 of AHU,s motor of AC plant any type all as directed by the Engineer-in-Charge.

6

-

-

... More
Supply only Pre filter type E4- 4/5 suitable for AHU/CSU unit box type with aluminmium extruded section frame and body and efficiency 90% down to 10 micron particles of following size complete all as specified and directed :-

-

-

-

... More
(a) Size of filter 610 x 610 x 50mm

15

-

-

... More
(b) Size of filter 305 x 610 x 50mm

2

-

-

... More
(c) Size of filter 500 x 350 x 50mm

30

-

-

... More
(d) Size of filter 500 x 500 x 50mm

30

-

-

... More
Supply only Fine filter type E4 -4/5 suitable for AHU/CSU unit box type with aluminmium extruded section frame and body and efficiency 90% down to 10 micron particle of following size complete all as specified and directed :-

-

-

-

... More
(a) Size of filter 610 x 610 x 150mm

15

-

-

... More
(b) Size of filter 305 x 610 x 150mm

2

-

-

... More
(c) Size of filter 500 x 350 x 150mm

30

-

-

... More
(d) Size of filter 500 x 500 x 150mm

30

-

-

... More
M&L for taking out Pump with motor of capacity 11 KW (406 USGPM & 486 USGPM) from central type AC plant, opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding wire of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed

2

-

-

... More
M&L for taking out AHU blower Motor 7.5 HP to 10 HP cap (BMS central AC plant), Dismantling the motor with disconnecting the same from the compressor and remove rubber coupling and its connected accessories and transporting to reputed work shop for rewinding . opening the motor, cutting & removing old and burnt winding wire, rewinding the motor with new super enameled copper winding of suitable size including insulating materials, varnishing, drying, replacement of both driven end non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed

2

-

-

... More
M&L for taking out CSU blower Motor and fixing of new blower motor suitable for 3 TR cap (BMS central AC plant), 1200 CFM Make Zeco Aircon Ltd, & connecting including testing and commissioning complete all as specified & directed.

4

-

-

... More
Supply and fixing Gate valve 25mm dia complete all as specified and as directed by Engr - in - charge

8

-

-

... More
Supply installation testing and commissioning of temp sensor & Humidistats as per existing of AC Plant installed at CSU, fixed in repairs all as specified and directed by Engr-in-charge. Model No QFM2160, 0-10Volt DC for 20 Mili amp Analog Output. Make Siemens or equivalent to Scheinder, Johnson Control

20

-

-

... More
M&L for Preventive maintenance including servicing / Checking of Building managment system (BMS) system complete twice in a year or in contract period carried out by OEM/Channel partner/authorised service vendor . The certificate of testing & checking of BMS System shall be produced Halfyearly after physical checking of system carried out by OEM/Authorised vendor/channel partner x 2 times in a year or contract period).The following equipment are under preventive maintenance :- (a) DDC panel 100 points controller - 12 Nos (b) DDC Panel 75 Points controller - 01 Nos (c) DDC Panel 60 points controller - 03 Nos (d) DDC Panel 30 Points controller - 03 Nos (e) LED Display 40" - 01 Nos Note : - (i). Repair/replacement of any defective parts such as contractor, controller, MCBs, connectors, control wire etc of DDC panels and cost of the same are deemed to be included in the quoted rate. (ii). Cost of installation of BMS Software (M/s Seimens) in case of corrupt and cost of renewal of Licence of BMS software for one year in case of expired within contract period . (iii) For the purpose of payment Preventive maintenance including servecing all the DDC panels & LED Display Building managment system (BMS) system on one occassion, shall be counted as one job.

2

-

-

... More
Note for Srl item no 1 to 17 : - (a) The cost of spares and labour for any servicing minor and major repairs of the part as and when required or as recommended by the OEM during inspection / analysis report shall be responsibility of the contractor and the unit rate quoted shall be deemed to include the cost of the same. The AMC includes the following: - (i) Checking the functioning of chiller unit /AHU/CSU/Pumps/hot water generator/controls and all such equipment covered under the contract. (ii) Free replacing of defective/worn out parts with new or repaired parts for compressor, thermostat/cut outs based on our assessment. (iii) Repairing of equipment as listed in the equipment list as specified in BOQ or as directed by Engr-in-Charge. (iv) Descaling of condensers / chemical cleaning of evaporator coils/ based on our assessment and working parameters of the plant. (v) Replenishing refrigerant gas and compressor oil in the system arising out of system defect, excluding complete replacement of compressor, AHU/CSU. (vi) Checking of compressor for its proper working. (vii) Annual pumping down and restarting as and when required. (viii) Checking of Microprocessor control boards, mother board, supply board, fan cards, heater relay board transducers of chillers/condensing unit for their correctness and replacement if necessary. (ix) Replacing of parts due to normal wear and tear

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.