Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681236_1Tender No
85277/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Supply install and testing in replacement of digital four pole non directional Microprocessor based IDMTL 3 over current +1 Earth fault with instantaneous element relay with high set & Aux. supply 20-110 volt DC as per existing make and model complete all as specified and directed by Engr-in-Charge
2
-
-
M&L for replacement of automatic spring charge motor of the Vacuum circuit breaker of existing make and model complete all as specified and directed.
4
-
-
S & F in replacement of 11 KV current transformer (CTs) for HT panels indoor type resin cast epoxy type of 13.1 KA/sec having ratio 60/5+5 Amps suitable for metering and protection of panels including control cables as per site requirement and fixing on bus bar section having class of accuracy 5P10, burden 15 VA. complete all as directed
6
-
-
S & F in replacement PT unit three phase three limb, epoxy type up to 11 KV draw out type single ratio having primary 11 KV & secondary voltage 110 volts 200 VA class I, including necessary bus bar connection & wiring for metering after disconnecting of HT supply from HT VCB of capacity 630 Amps complete all as directed.
4
-
-
S & F in replacement of Epoxy Cast Resin RMU CT Low Voltage Instrument transformer, technical specification for metering accuracy class: 1.1,0.2s,0.5s,0.2,0.5,1,3,5 suitable for existing RMU unit. Working on rated primary current 10000 Amp and secondary current of 05 Amp with nominal system voltage of 0.60 kV including control cables as per site requirement complete all as directed.
8
-
-
M&L for repair of ON/OFF mechanism of VCB drawout/fixed type by inspecting Actuator (elctromagnetic or spring-motor) for any defectes and replacement of defective VCB Mechanism as per existing make & model. Performing test for controled movement of the power contacts for proper locking them in ON/OFF positions by repeating ON/OFF test two time and refixing the all parts in its original position including testing and commissioning complete all as directed by Engr-in-Charge.
Note:- Contractor will make all necessary arangement of T&P for opening out the VCB trolley/fixed panel, repair work to be carried out by skilled authorised person.
2
-
-
S&F in replacement of vacuum interrupter as per existing make and model and suitable for 11 KV HT VCB 11 KV 630/800A capacity.
3
-
-
S&F in replacement fixed contact block as per existing make and model and suitable for V.C.B 11 KV 630/800 Amps capacity all as specified and directed.
6
-
-
S&F in replacement moving contact block as per existing make and model and suitable for V.C.B 11 KV 630 /800 Amps capacity all as specified and directed.
5
-
-
S&F in replacement motor & gear assembly 220Volt AC motorised mechanism as per existing make and model and suitable for ACB 11 KV 630/800 Amps capacity including testing & putting on load all as specified and directed.
5
-
-
S&F in replacement closing coil assembly 24/110V DC as per existing make and model and suitable for HT VCB 11 KV 630/ 800A capacity complete all as specified and directed.
6
-
-
S & F in replacement tripping coil assembly 24/110V DC as per existing make and model and suitable for HT VCB 11 KV 630/800A capacity
6
-
-
S & F in replacement auxiliary switch (6 No+6NC) as per existing make and model and suitable for HT VCB 11 KV 630/800 Amps capacity
6
-
-
M&L for tracing out HT cable fault through HT fault locator machine by HT expert and testing of HT cable through megger and repair the same. Note:- The cost of the earth work, equipment and person required for locating fault is inclusive in unit rate (ii) Joint of cable will be measured separately under relevant item.
8
-
-
Labour for shifting of RMU/VCBs panel complete from one place to another place by disconnecting its all electrical connections transporting though their own veh and loading unloading etc. Note- The cost of the transporting veh and crane is deemed to be included in unit rate.
5
-
-
Supply install and testing in replacement of Slim innovative self Power Protection Relay for RMUs with Horizontal/Vertical mounting options, relay get energize either from current,Aux. voltage, front USB or internal battery (whichever is available); O/C, S/C,E/F and E/F hight set protection; O/C and E/F individually selected for phase and earth fault; Unba. Having application for remote trip & remote protection block input DI; RS485 modbus; USB port for PC/laptop interface; Circuit breaker failure protection (50BF); wide operating ranges of the auxiliary supply voltage, last 5 fault and 10 event record with time stamp, all as per existing make and model complete all as specified and directed by Engr-in-Charge
5
-
-
S & F in replacement of ER14250 1/2 AA 3.6 Volt Lithium battery of capacity 1200mAh for auxiliary supply to Power protection relays of RMUs suitable for existing make and model complete all as specified and directed by Engr-in-Charge.
40
-
-
S & F in replacement of Live line indicators for IN/Out supply for Load Breakers in RMUs suitable for existing make and model complete all as specified and directed by Engr-in-Charge.
10
-
-
Supply install and testing in replacemen Automatic Voltage Regulating relay, three phase for automatically setting tapping value set desired values, Model JVS-801 make Microw Electronics Components or equivalent make complete all as specified and directed by Engr-in-Charge
2
-
-
Supply & fixing in replacement maintenance free lead acid Lithium battery incl connection to auxilary circuit of RMU used to energize during main power failures. Make:- Leoch UPLUS LP 12-12 (12V 12 Ah) battery or equivalent all as specified and directed by Engr-in-Charge
12
-
-
M & L in repair for replacement of 90 degree lug boot for RMU HT terminals on each phase for protection of the HT termainals from moisture/dust etc complete all as specified and as directed.
10
-
-
Supply, jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
6
-
-
Supply jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of 50 to 95 Sqmm complete all as specified and directed.
5
-
-
Supply, jointing and testing cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 50 to 95 sqmm. complete all as specified and directed.
7
-
-
Supply ,jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 to 185 sqmm complete all as directed.
2
-
-
Supply, jointing and testing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of 120 to 185 Sqmm complete all as specified and directed.
3
-
-
Supply, jointing and testing cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of size 120 to 185 sqmm. complete all as specified and directed.
2
-
-
M& L for cutting under the road /pavement /hard standing or in any other situation with the help of manual labour for crossing of U/G cable through it and making both the end good complete all as specified and directed .
36
-
-
Supply and laying galvanised steel water tubing, light grade, IS-1239 marked with all fittings ISI marked and laid in trenches under roads, through drains, fixed to poles/walls with required size flat iron clamp bolts, nuts and washers, for cable protection of 100 mm dia, including taking out old/existing pipes, complete all as specified and directed.
36
-
-
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exc. 10sqm on plan and not exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
182.25
-
-
Taking out HT UG cables of 95/120 Sqmm by excavation and earth work in any type of soil, removing bricks or PCC cover of any size, stacking serviceable cable for reuse complete all as specified and directed
NOTE:- (i) Excavation, Joints & Jointing materials, new cable, additional bricks/PCC Covers, sand shall be measured & paid for separately.
600
-
-
Supply & fix in replacement of HT 11 KV 3 core 185 Sqmm cable in trenches/fixed to poles/wall, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable( HT ), heavy duty with aluminum conductor, 11000 volts (earthed) grade all as specified and directed by EIC.(Note : (i) Excavation, earthwork, cable joints, sand cushioning & cable cover will be measured and paid separately if required
100
-
-
Supply & fix in replacement of HT 11 KV 3 core 95 Sqmm cable in trenches/fixed to poles/wall, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable( HT ), heavy duty with aluminum conductor, 11000 volts (earthed) grade all as specified and directed by EIC.(Note : (i) Excavation, earthwork, cable joints, sand cushioning & cable cover will be measured and paid separately if required
200
-
-
Labour for re-laying the serviceable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminum conductor, 11000 volts Earthed, grade cross sectional area 95/120 sqmm 3 core in trenches/fixed to poles/wall, complete all as specified and directed by EIC.(Note : (i) Excavation, earthwork, cable joints, sand cushioning & cable cover will be measured and paid separately if required)
300
-
-
M&L for sand cushioning for UG cables using dry sand; with gently punning down all as directed and specified. (Note : For measurement purpose punned thickness shall be considered)
37.26
-
-
Supply and laying unreinforced precast concrete cable covers class HV type I, flat size 300x180x40 mm laid transverse to cable.
1666
-
-
Relaying only of unreinforced precast concrete cable covers class HV type I, flat size 300x180x40 mm laid transverse to cable.
834
-
-
Returning filling in soil and including spreading leveling watering and well ramming in layers n.exc. 25 cm thick
125.63
-
-
Removing excavated soil to a distance n.exc. 50 mtr and depositing where directed at a level n.exc. 1.5m above the starting points.
56.62
-
-
Supply fabricate, testing and commissioning of factory made HT outdoor distribution panel board single door of size 1200mm x 1200mm x 800mm including locking arrangement cubical type dust and virmin proof, weather proof, aesthetical designed, IP54 degree of ingress protection, fabricated with 3mm thick CRCA sheet with front and rear opening including 3 strips of copper bus bar of 600 Amps current carrying capacity insulated with colour sleeves, porcelain/epoxy insulators 11000V, rail channel, cable entry, danger notice plate of 11000 Volt, angle iron frame of size 50x50x6mm and 60cm grouted in ground and 60cm above GL including necessary excavation, foundation, PCC etc. complete duly powder coated of approved colour all as specified and directed by Engr- In- Charge.
2
-
-
M&L in replacement of chemical earthing complete with Perforated GI Pipe of 80 mm Medium Grade with hole on peripheri in symmetric zig zag manner buried directly in ground vertically in bore of size 200 mm Dia and depth not less than 12.00 mtr below ground level connected to and including GI strip of 32x6mm as earth lead up to 18 mtr long fixed by means of bolts, nuts, check nuts and washers and welding etc. of galvanised iron or steel including provn of GI protection pipe light grade of 40mm bore on earth strip from earth pit to test point all as shown in electrical plate No.5 of SSR Part-I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (reinforced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 15mm bore medium grade, wire mesh and lugs, test point including salt (350KG), Coal dust(225KG) & Magnesium sulphate (350KG) including refilling of earth pit with cultivated black cotton soil and removal of surplus soil upto 50mtrs apart etc. complete all as directed by EIC. Note: GI strip exceeding 18m long shall be measured & paid separately.The earth resistance value less than 1 ohm.Failing to achieve the value the contractor shall be re do the earthing without any extra cost.
10
-
-
Supply fabricate, testing and commissioning of factory made LT outdoor busbar panel single door of size 1200mm x 800mm x 400mm including locking arrangement cubical type dust and virmin proof, weather proof, aesthetical designed, IP54 degree of ingress protection, fabricated with 3.15mm thick CRCA sheet with front and rear opening including 4 strips of alluminium bus bar of 300 Amps current carrying capacity insulated with colour sleeves, porcelain/epoxy insulators 1100V, rail channel, cable entry, danger notice plate of 1100 Volt, angle iron frame of size 50x50x6mm and 60cm grouted in ground and 90cm above GL including necessary excavation, foundation, PCC etc. complete duly powder coated of approved colour all as specified and directed by Engr- In- Charge.
1
-
-
Supply, installing, testing and commissioning, in repair factory made and tested LT Panel, outdoor type floor mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber duly insulated. The panel shall be dust and vermin proof, IP 65 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron base frame work, powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, both side opening type, with aprons for cable entry, with double door and locking arrangement and including earth work. The panel consisting of the following:- (a) Aluminum bus bar four strips 300 Amps ,415 volts, fixed horizontally, duly insulated with heat shrinkable sleeves in colour code - 01 Set.
(b) MCCB, 04 Pole, 200 Amps with ultimate breaking capacity 36 KA - 01 No (Incoming) (c) MCCB, 04 pole, 100 Amps with breaking capacity 25 KA - 01 No
(d) MCCB, 04 pole, 63 Amps with breaking capacity 25 KA - 02 Nos
(e) MCCB, 04 pole, 40 Amps with breaking capacity 25KA - 02 Nos
(f) Euroload changeover switch 415 volts (4pole) 200 Amps - 01 Nos (g) Digital Volt meter 0-500 volt with coil and selector switch - 1 No.
(h) Digital ammeter 0-500Amps with CT coil and selector switch - 01 No
(j) Indication lamps R,Y,B LED type – 1 set of three (k) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled and aluminum strips for MCCB's.
(l) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone , 15 cm thick in foundation, cemented block/brick work in CM 1:6 with sub class `B', old size bricks, rendering 15mm thick in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 30cm above and 15 Cm below the ground level. - Compartmentalized Panel Dimensions (870mmx1970mmx450mm)(W*H*D)
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%