Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Military Engineer Services - MES Tender
Eprocure
Opening Date21 Aug 2021
Closing Date18 Sep 2021
Tender Amount₹ 37,49,790 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 86,600Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_MES_469785_1Bid Award Id
ViewTender No
8951/21-22/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
170
-
-
... More
Taking down cement or cement lime mortar plaster, any description on brick or stone walls etc, including rackingout joints, hacking for key, scrubbing down with water etc. complete all as specified and as directed.
125
-
-
... More
M&L for kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over and including 10mm thick plaster as backing coat in CM (1:4) complete all as specified and as directed.
20
-
-
... More
M&L for rendering 10mm thick on fair faces of concrete or block masonary in CM (1:6) finishing the surface even and smooth without using extra cement in internal surface of wall complete all as specified and as directed.
105
-
-
... More
M&L for preparation of newely plastered surface of wall and applying two coats of cement base paint complete all as specified and as directed.
105
-
-
... More
Demolition of wall of brick and stone wall built in cement mortor incl all quoins, archs, pillars, etc complete all as specified and as directed.
1.8
-
-
... More
M&L for brick work sub class B bricks, straight or curved on plan exc. 6m mean radius built in CM (1:6) complete all as specified and as directed.
1.5
-
-
... More
M&L for half brick work sub class B bricks, straight or curved on plan to any radius built in half brick thick walls built in CM (1:4) complete all as specified and as directed.
4
-
-
... More
M&L for preparation of old surfaces of wall and applying one coat of white wash complete all as specified and as directed.
100
-
-
... More
M&L for preparation of old steel surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
35
-
-
... More
M&L for preparation of old wooden surfaces of any description not other wise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
75
-
-
... More
M&L for complete removal of existing treatment from old wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and as directed.
200
-
-
... More
Demolition of reinforced cement concrete (reinforcement cut as requried to facilitate) complete all as specified and as directed.
1
-
-
... More
M&L for mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and including welded with new reinforcement to existing reinforcement and grouting of beams/ columns/ lintels etc complete all as specified and as directed.
90
-
-
... More
M&L for reinforced cement concrete (nominal mix) (1:2:4) type B-1 (using 20mm garded stone aggregates) as in as slab, suspended slab, chajjas, facia, shelves, plateform and the like complete all as specified and as directed.
1
-
-
... More
Formworks to sides and soffits of shelves, plateform and the like rough finished surface of concrete complete all as specified and as directed.
11
-
-
... More
S&F in repair perforated particle board/ tiles 25mm thick for insulation and accoustic purposes, 60cm x 60cm in size, fixed with nails to timber frame work or with staples on snap grid complete all as specified and as directed.
50
-
-
... More
Taking down chowkats or frame exc. 1.5 Sqm and n. exc. 4.0 Sqm each (without taking off shutter from the frame) complete all as specified and as directed.
4
-
-
... More
M&L for aluminium door powder coated (powder coated of required colour) with frame of section 100mm x 44mm x 2.5mm thick and shutter with bottom rail of section 150mm x 44.5mm x 2.5mm thick, middle rail of section 85mm x 44.5mm x 2.5mm thick and top rail of section 80.4mm x 44.5mm x 2.5mm thick and style of section 80.4mm x 44.5mm x 2.5mm thick with 5mm thick glass (plain/ tinted/ with laminted film) or prelaminted board fixed in postion with aluminium beading including necessary rubber gaskets and 2 Nos aluminium push plate handle of alumimnum section 150mm wide and 2.5 mm thick inculding 150mm aluminium tower bolt brass mortice lock complete all as specified and as directed.
10
-
-
... More
S&F for aluminium ventilator, louvers type, frame top & bottom of size 31mm x 42mm x 1.60mm (section No 20558) rectangular tub of size 40mm x 20mm x 2mm (section No 14019 and middle vertical of size 42mm x 46.20mm x 1.60mm Section (20560) and clip for fixing wire mesh and glass of size 19mm x 17.30mm x 0.90mm (section No 19360) thick including stainless steel wire cloth 0.36mm nomonal dia of wire and 1.40mm average width of aperture and fixed with stainless steel wire staples and supply and fixing 5mm thick forsted/pinheaded glass louvers with blades of 100mm heavy duty with necessary rubber beading, gasket etc. complete all as specified and as directed by Engineer-in-Charge.
1.5
-
-
... More
S&F aluminium anodised grill of 7.00mm dia squares rectangular triangular circular shape aperture n. exc. 7.00cm in length or width fixed with H or F channel make grill No. 20 of décor complete all as specified and as directed.
1.5
-
-
... More
M&L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregates) as in foundation of posts and pillars etc. complete all as specified and as directed.
3.5
-
-
... More
M&L for preparation of new steel surface of any description over 10cm width or grith not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and as directed.
268
-
-
... More
M&L for preparation of new wooden surfaces of any description, not other wise described, over 10cm width or girth, and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
155
-
-
... More
M&L for preparation of old wooden surfaces of any description, not other wise described, over 10cm width or girth, and applying two coats of synthetic enamel paint complete all as specified and as directed.
650
-
-
... More
S&F framed brackets of angles or tees with web and flanges, purlins etc, cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc. n. exc. 10 Kg each brackets confirming to Fe 290 Gde-E-165 as in cooler stands and other similar works etc. complete all as specified and as directed.
125
-
-
... More
M&L for mild steel screw bolts 16mm to 20mm diameter of neck (machine made) with hexagonal or square heads at one end and screwed the othger, or screwed both ends, each screwed end to be fitted with washers and one haxagonal or square nut but length of bolt exc. 22.5cm and n. exc. 30cm long complete all as specified and as directed.
12
-
-
... More
Taking dawn CI pipe 100mm/ 75mm of any description complete all as specified and as directed by Engineer-in-Charge.
4
-
-
... More
S&F for CI waste and vent pipes in any length with or without ears, fixed to wall dia of pipe 100mm complete all as specified and as directed by Engineer-in-Charge.
4
-
-
... More
S&F 100mm cast iron sanitary connection-short connection pipe of length upto 300mm socket to fit WC out-let etc. complete all as specified and as directed.
4
-
-
... More
S&F cast iron bend 100mm bore (any radius) dimnishing pieces or tapers with oval access doors etc. complete all as specified and as directed.
4
-
-
... More
S&F CI cowls of size 100mm complete all as specified and as directed.
4
-
-
... More
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and as directed.
150
-
-
... More
M&L for false ceiling of 600mm x 600mm x 15mm mineral fibre ceiling tiles RH-99 of type micro looks edge laid on super fine XL 15mm expose d grid systems with 15mm wide T- section flanges. The frame work comprises of main runner of size 15mm x 32mm x 3000mm spaced at 1200mm centre securing fixed to the structural soffits by approved hangers at 1200mm maximum centers. Hangers (GI wire of 4.0mm dia) to be fixed by approved roof plug, level adjusters and screws etc. The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall flush fitting 1200mm long cross tees of size 15mm x 26mm x 1200mm to be interloched between main runners at 600mm centers to form a 1200mm x 600mm module. Cut cross tees longer than that 600mm to be supported independently. 600mm x 600mm modules to be formed by fitting 600mm long flush fitting cross tees of size 15mm x 26mm x 600mm centrally between the 1200mm crosstees perimeter wall angle of size 19mm x 19mm x 3000mm secured to wall at 450mm maximum centres. Finally RH-99 mineral fibre tile 15mm thick micro complete all as specified and as directed.
150
-
-
... More
Removing of existing unserviceable water proofing treatment (except PCC padding) taking down cement plaster etc, of any description and cleaning of top surface of cement concrete flushing out junction of parapet walls & washing down with water to remove all dirt etc including preparation of surfaces to receive new treatment and removing the rubbish off premises complete all as specified and as directed.
170
-
-
... More
M&L for applying cold bituminous primer @ 0.30 Ltr/ Sqm conforming to IS : 3384 laying APP polymer modified membrane 3.6 to 4.0 Kg/ Sqm in weight with non-woven polyster reinforcement (mineral gravel finish on upper side of the membrane) and sealing all overlaps of 100mm in length side and 150mm on width side of membrane by torching the same as per manufacture instruction and all as per specified particular specification and including 10mm thick screed bed in CM (1:3) mixed with WPT 3% by weight of cement complete all as specified and as directed.
170
-
-
... More
Supply only intergral water proofing compound complete all as specified and as directed.
40
-
-
... More
S&F in repairs 35mm thick block boards, grade 1 quality, exterior grade, commercial type, fixed with screws to timer frame work or with steel frame work and fixing of 2mm thick linoleum on top of block board, plain coloured, including stretching, cutting, fitting with sealed down with an approved adhesive complete all as specified and as directed.
120
-
-
... More
M&L for aluminium partition powder coated made with aluminium section 38.80mm x 1.80mm/ 114.30mm x 45.45mm x 3mm section No 4587 of jindal, national hindalco fixed in wall including provision for receiving glass pane etc and fixing the same with aluminium anodised beading and rubber gasket including 5mm thick glass (black/ tinted/ plain) and all necessary fittings complete all as specified and as directed.
25
-
-
... More
M&L for 50mm thick PCC (1:2:4) type B2 (using 40mm graded stone aggregates) including necessary form work etc all as specified and directed
76
-
-
... More
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed.
4300
-
-
... More
S&F welded steel wire fabric not exceeding 4 Kg/ Sqm supplied and fixed complete to steel members complete all as specified and as directed.
1100
-
-
... More
S&F 125mm long butt hinges, heavy weight, cold rolled mild steel and fixed to frame with screws or weld complete all as specified and as directed.
40
-
-
... More
S&F 150mm long mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and as directed.
15
-
-
... More
Excavating in post holes each n. exc. 0.5 Cum getting out in soft/ loose soil, and removing surfaces soil to a distance n. exc. 50m and making good surfaces complete all as specified and as directed.
18
-
-
... More
M&L for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering fixed with self tapping screws complete all as speified and as directed by Engineer-in-Charge.
182
-
-
... More
Excavation over area n. exc. 1.5 mtr deep and getting out soft/ loose soil complete all as specified and as directed.
60
-
-
... More
M&L for hardcore of brocken stone or boulder gauge n. exc. 63mm, deposited, sprade and levelled in layers n. exc. 15cm thick watered and rammed to true surface complete all as specified and as directed.
41
-
-
... More
M&L for 75mm thick PCC (1:4:8) type D2 (using 40mm graded stone aggregates) as in sub base complete all as specified and as directed.
280
-
-
... More
M&L for machine pressed precast conctete interlocking glossy/ lacquer finish paver block any shape and size with grey cement and pigment confirming to IS : 15658-2006 of 60mm thickness including 2mm thick rubber mould glossy/ lacquer finish paver block of Grade M-35 and over sand cushion complete all as specified and as directed.
Note:- Sand will be measured and paid separately.
280
-
-
... More
M&L for precast cement concrete (1:2:4) type B0 (using 12.5mm and below stone aggregate) as in kerb stone factory made as approved by GE with plain fair faces including champhering, weathering etc complete with joint to match in CM (1:6) complete all as specified and as directed.
2
-
-
... More
S&F 1.60mm thick mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and as directed.
40
-
-
... More
S&F bands, straps, supports or stays for large gates for fixing of sheets etc. hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed.
120
-
-
... More
M&L for preparation of newely plastered wall surfaces and applying three coats of white wash complete all as specified and as directed.
10
-
-
... More
S&F SS drapery rod 25mm dia, with standard type socket, knob, holders, brackets etc. drilling in existing wall and fixed with screw complete all as specified and as directed.
150
-
-
... More
M&L for aluminium powder coated sliding door (powder coated of required colour) with one track frame of section 100mm x 44mm x 2.5mm thick and shutter with bottom rail of section 150mm x 44.5mm x 2.5mm thick, middle rail of section 85mm x 44.5mm x 2.5mm thick and top rail of section 80.4mm x 44.5mm x 2.5mm thick and style of section 80.4mm x 44.5mm x 2.5mm thick with 5 mm thick glass (plain/ tinted/ with laminted film) or prelaminted board fixed in postion with aluminium beading including necessary rubber gaskets and 2 Nos. aluminium push plate handle of alumimnum section 150mm wide and 2.5mm thick inculding 150mm aluminium tower bolt brass mortice lock complete all as per drwaing No. CEAA/TD/63 sheet No. 2/2 complete all as specified and as directed.
5.8
-
-
... More
Taking down carefully point wiring of any type, size and description (light, fan, socket outlet etc.) including removal of battens, pipes, sockets, switches, ceiling roses, light fittings etc, complete and making good the disturbed surfaces to match with existing, complete all as specified and as directed.
65
-
-
... More
Dismantling and taking down fluorescent tube light single/ double of any wattage or size street light fittings for repair or replacement of burnt/ worn out accessories or carrying to MES store or as schedule of credit complete all as specified and as directed.
5
-
-
... More
Taking down main switches, bus bar, distribution boards etc of any type and capacity along with the existing boards, and removing the same from site and making good the disturbed surfaces/ portion of walls etc. complete all as specified and as directed.
8
-
-
... More
M&L for concealed sub main wiring of two run with 06 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 Volts grade, drawn through and in existing conduit pipe including one run of 6.0 Sqmm single core PVC insulated, FRLS , flexible copper cable as earth continuity conductor in green colour complete all as specified and as directed.
Note:- (a) Two runs of single core cable with one run of earth continuity cable will be measured and paid as one unit. (b) Make disturbed surface good to wall/ floors.
65
-
-
... More
M&L for sub main wiring of two run with 4.0 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing-capping of size 25mm x 16mm medium grade and accessories of suitable size and fixed on wall/ ceiling including one run of 4.0 Sqmm single core PVC insulated, FRLS, flexible copper cable as earth continuity conductor in green colour complete all as specified and as directed.
Note:- (a) Two runs of single core cable with one run of earth continuity cable including PVC casing-capping and its accessories will be measured and paid as one unit. (b) Make disturbed surface good to wall/ floors.
75
-
-
... More
M&L for point wiring complete with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable 1100 volt grade, (FRLS) through and including 20mm x 12 mm PVC casing-capping and its accessories, cadmium screws and including 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor cable (FRLS) as earth continuity conductor and MS boxes made of 16 gauge MS sheet concealed type on walls cover 3mm thick for housing complete all as specified and as directed for One light/ fan point controlled by one, one way switch.
10
-
-
... More
All as per Item No. 65 above but one socket outlet 05 Amps on the same board.
4
-
-
... More
All as per Item No. 65 above but one socket outlet 05 Amps on independent board.
12
-
-
... More
All as per Item No. 65 above but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket.
14
-
-
... More
All as per Item No. 65 above but point wiring with 4.0 Sqmm cable and 4.0 Sqmm earth continuity conductor for AC Point.
9
-
-
... More
M&L for concealed point wiring complete with FRLS PVC insulated/ unsheathed stranded copper conductor of wire 1.5 Sqmm, 1100 Volt grade, alongwith one single core of same size stranded copper as continuous earth wire to common earth dolly in and including PVC conduit pipe fitting medium grade of 25mm dia fixed in concealed surface of wall/ ceilling/ false ceilling including cutting/ chasing in wall as required with powder coated sheet metal terminal boxes of required sizes and thickness (factory made) sunk in wall only with 3.0mm thick laminated sheet where as required and accessories complete suitable for one light/ fan point controlled by one on way switch.
8
-
-
... More
All as per Item No. 70 above but one socket outlet 05 Amps on the same board.
4
-
-
... More
All as per Item No. 70 above but one socket outlet 05 Amps on independent board.
5
-
-
... More
All as per Item No. 70 above but point wiring with 2.5 Sqmm cable and 2.5 Sqmm earth continuity conductor for 3 pin 15 Amp socket.
5
-
-
... More
S&F switch piano, single pole, one way, 5 Amps, 240 Volt capacity flush type complete all as specified and as directed.
26
-
-
... More
S&F 3 pin 5 Amps socket flush type multipurpose 2 in 1 type 3 pin complete all as specified and as directed.
8
-
-
... More
S&F 5 pin, 5 Amps switch and socket combination, flush type, multipurpose 2 in 1 (2 pin & 3 pin) complete all as specified and as directed.
16
-
-
... More
S&F 3 pin, 15 Amps switch socket combination, flush type, multi purpose 2 in 1 type (3 pin 5 Amps and 15 Amps) complete all as specified and as directed.
19
-
-
... More
S&F on wall, plug and socket in sheet steel enclosure with songle pole & earth, suitable for 20 Amp with providing MCB SP 20 Amp suitable for single phase AC supply complete all as specified and as directed.
9
-
-
... More
S&F in replacement of LED batten fitting alongwith removable LED Tube 20 W, 230 Volt, 6000 K, wall/ ceiling mounted, LED batten fixed by means of bolts, ABS rotor suitable for single side connections. LED rod having glass material complete haivng lumen efficacy minimum 100 lm/w, CCT 6500 K, powered by integral constant current driver suitable for 240 V AC with all accessories internallly prewired including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
5
-
-
... More
S&F ceiling rose, 5 Amps, surface type, 240 Volts, bakelite, three terminal complete all as specified and as directed.
85
-
-
... More
S&F in replacement 4 way sheet metal enclosures for flush/ surface mounting distribution board double door, 240 volts factory made and tested complete, suitable for mounting MCBs with 200 Amps rated bus bar, cable lugs etc. complete all as specified and as directed.
2
-
-
... More
All as per Item No. 81 above but 8 way.
4
-
-
... More
All as per Item No. 81 but 4 way, 415 Volts TPN DB.
2
-
-
... More
S&F SP 5 To 32 Amp rating 240 V, 10 KA 'C' curve miniature circuit breaker (MCB) in the MCB DB complete with connection testing and commissioning all as specified and as directed.
30
-
-
... More
All as per Item No. 84 above but SPN 32 Amp.
4
-
-
... More
All as per Item No. 84 above but SPN 40 to 63 Amp.
2
-
-
... More
S&F TPN 40 to 100 Amp capacity, 415 V, 10 KA 'C' curve miniature circuit breaker (MCB) in the DB with connection testing and commissioning all as specified and as directed.
4
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick electrode, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to 4 mm dia galvanized earth wire by means of bolts, nuts, check-nuts and washers of galvanized iron or steel all as shown in electrical plate No 5 (duly protected with 15 mm dia light grade GI pipe upto 7.5m from the earth plate) and connected to GI steel earth plate including charcoal, dust, common salt, necessary excavation in soft/ loose soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m from the starting point, watering pipe 20 mm bore GI tube of light grade treated with 1 No PGI funnel, pit of PCC 1:2:4 type B-1/ RCC (1:2:4) type B-1, pit cover 75 mm thick reinforced with 6 mm dia bars @ 75 mm c/c both ways and with MS handle 12 mm dia connected to earth test point including testing complete all as specified and as directed.
2
-
-
... More
S&F exhaust fan, steel body, AC, single phase, 230 V of size 300m sweep with, blades, and frame and louvers complete all as specified and as directed.
4
-
-
... More
S&F air circulator fans, 230 Volts, single phase, oscillating 450mm sweep suitable for wall mounting complete all as specified and as directed.
4
-
-
... More
S&F air circulator fans, 230 Volts, single phase, oscillating 400mm sweep suitable for wall mounting complete all as specified and as directed.
1
-
-
... More
M&L for chemical earthing with copper earth plate 90x60cmx5mm and copper earth strip 32mm x 6mm complete all as specified and as directed.
2
-
-
... More
Taking down existing exhaust fan servicing, painting and refixing new location after making hole of suitable size as per direction complete all as specified and as directed.
3
-
-
... More
Taking down carefully split type 1.50/ 2.00 Ton capacity, from its location inculding indoor and outdoor unit including copper piping, insulation, wire, outdoor stand and shifting to new location as per direction of Engineer-in-Charge.
9
-
-
... More
Taking down carefully tower AC 3.5 Ton capacity, from its location inculding indoor and outdoor unit including copper piping, insulation, wire, outdoor stand and shifting to new location as per direction of Engineer-in-Charge.
2
-
-
... More
S&F copper piping for connecting indoor and outdoor unit of split/ tower AC complete all as specified and as directed.
200
-
-
... More
S&F PVC insulated 4 Sqmm 3 core flexible round copper conductor.
200
-
-
... More
S&F foam armour for AC copper tubing alongwith taping complete all as specified and as directed.
200
-
-
... More
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 Volts, earthed grade, cross sectional area 25 Sqmm complete all as specified and as directed.
200
-
-
... More
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 Volts earthed grade, cross sectional area 95 Sqmm complete all as specified and as directed.
200
-
-
... More
S&F three phase bus bar enclosure made out of 3.15mm thickness CRCA sheet including necessary MS angle iron work for fixing in undeground surface and with duly powder coated comprising of:-
(a) 04 Nos bus bar 450 Amp capacity.
(b) 300 Amp MCCB 4 pole - 01 No.
(c) Indicating lamp set - R,Y,B - 01 Set.
(d) Changer over switch open execution 630 Amp.
1
-
-
... More
Excavation in trenches not exceeding 1.5 mtr wide, not exceeding 1.5 mtr in depth not exceeding 10 Sqm on plan and getting out in soft/ loose soil complete all as specified and as directed.
81
-
-
... More
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
62
-
-
... More
Removing excavated materials not exceeding 50 mtrs away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
85
-
-
... More
Supply and laying clean dry sand for cable cushioning including gently punning down complete all as specified and as directed.
31
-
-
... More
M&L for bricks laid in trenches for cable protection, well burnt sub class ‘B’, abutting each other width equal to length complete all as specified and as directed.
2400
-
-
... More
Supply, install, testing and commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 100 LPD with electrical back up complete all as specified and as directed.
Note:- Rate of solar water system includes the cost of backup stainless steel hot water tank only insultated.
8
-
-
... More
Supply, install, testing and commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD with electrical back up complete all as specified and as directed.
Note:- Rate of solar water system includes the cost of backup stainless steel hot water tank only insultated.
2
-
-
... More
Supply and install hot water pipe duly insulated with glass
wool and aluminium cladding 15mm bore complete all as specified and as directed.
110
-
-
... More
Supply and install hot water pipe duly insulated with glass
wool and aluminium cladding 20mm bore complete all as specified and as directed.
60
-
-
... More
Supply and install hot water pipe duly insulated with glass
wool and aluminium cladding 25mm bore complete all as specified and as directed.
70
-
-
... More
S&F rotational moulded polyethylene water storage tank of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all asspecified in SSR Part-I complete all as specified and as directed.
8
-
-
... More
S&F rotational moulded polyethylene water storage tank of capacity 750 litres (cylindrical vertical with closed top) hoisted and fixed in position all asspecified in SSR Part-I complete all as specified and as directed.
2
-
-
... More
S&F steel water tubing 25mm dia in bore, medium grade, galvanised, with all fittings, fixed complete to wall and ceiling or laid in floor complete all as specified and as directed.
40
-
-
... More
S&F 25mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipes and fixed complete all as specified and as directed.
10
-
-
... More
M&L for concealed sub main wiring of two run with 2.5 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit and accessories of suitable size and fixed on concealed surface of wall/ ceiling with cutting chases including one run of 2.5 Sqmm single core PVC insulated, FRLS, flexible copper cable as earth continuity conductor in green colour complete all as specified and as directed.
Note:- (a) Two runs of single core cable with one run of earth continuity cable will be measured and paid as one unit. (b) Make disturbed surface good to wall/ floors.
140
-
-
... More
S&F 15mm size bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe, CP type complete all as specified and as directed.
10
-
-
... More
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 Amp complete all as specified and as directed.
15
-
-
... More
S&F electric water heater, storage type, steel body with copper inner tank and heating element upto 2.0 KW, capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, including making hole and fastners connection piece etc. complete all as specified and as directed.
5
-
-
... More
S&F 15mm size stop valve, CP, fancy type, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes or for unions complete all as specified and as directed.
5
-
-
... More
S&F 15mm size bib taps, CP, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe complete all as specified and as directed.
5
-
-
... More
S&F PVC connection of size 15mm x 450mm long for hot water supply complete all as specified and as directed.
10
-
-
... More
M&L for concealed sub main wiring of two run with 2.5 Sqmm single core PVC insulated, FRLS, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC casing capping and accessories of suitable size and fixed on concealed surface of wall/ ceiling with cutting chases including one run of 2.5 Sqmm single core PVC insulated, FRLS, flexible copper cable as earth continuity conductor in green colour complete all as specified and as directed.
Note:- (a) Two runs of single core cable with one run of earth continuity cable will be measured and paid as one unit. (b) Make disturbed surface good to wall/ floors.
140
-
-
... More
S&F steel water tubing 15mm dia in bore, medium grade, galvanised, with all fittings, fixed complete to wall and ceiling or laid in floor complete all as specified and as directed.
35
-
-
... More
S&F 20mm bore gun metal globe or gate valve with iron wheel head screwed both ends for iron pipes and fixed complete all as specified and as directed.
5
-
-
... More
S&F single pole MCB 240 Volt, 6 to 32 Amp, 'B' series in the MCB DB complete with connection testing and commissioning complete all as specified and as directed.
5
-
-
... More
S&F detectors complying with and type certified to EN - 45 addressable type smoke detector photoelectric/ optical
with base with self built intelligence as per IS : 11360 fixed at location as per direction of Engineer-in-Charge.
24
-
-
... More
S&F Fire Alarm Sounders/ Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of (+) 5 DB 500 mtrs range fixed at location as per direction of Engineer-in-Charge.
4
-
-
... More
S&F fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 30 detectors and 30 modules complete all as specified and as directed.
1
-
-
... More
M&L for wiring for circuit/ submain wiring alongwith earth wire with the sizes of FR is PVC insulated copper conductor, single core cable in surface/ recessed as required 2x1.5 Sqmm + 1x1.5 Sqmm earth wire in steel conduit for connection of Fire smoke detector from control panel and fire alarm sound detection system as per site requirement and as per dreiction of Engineer-in-Charge.
Note:- (a) Two runs of single core cable with one run of earth continuity cable will be measured and paid as one unit. (b) Make disturbed surface good to wall/ floors.
116
-
-
... More
Taking down ceiling fan of any size/ sweep from different locations in Air Force Station dismantling and removing fan rod to store and re-assembling and refixing fan at its original location after placing smart fan down rod and fan clamp and rubber gromments, split pin, shakle, spindle, nut-bolts, safety pin, hanger clamp etc. complete all as specified and as directed.
Note:- Old MS fan rod to be deposited to MES store yard.
160
-
-
... More
S&F smart fan down rod (anti sucide fan rod) of length 10" complete all as specified and as directed.
618
-
-
... More
S&F smart fan down rod (anti sucide fan rod) of length 15" complete all as specified and as directed.
40
-
-