Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_633084_1Bid Award Id
ViewTender No
8838/Okha/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Certain repair / maintenance of street lights, solar lights, UG cables, feeder pillar, APFC Panel, cooling appliances and allied works at INS Dwarka Okha under GE Navy Porbandar
Tender General Pages, Special Conditions and Particular Specifications of Contract
BOQ Items
M&L and Repair/Replacement for erecting of Prestressed concrete pole 9.0 metres long, 102x152mm at top and 102x289mm at bottom, class 10 complete all as specified and directed.
4
-
-
Material and labour for painting to Prestressed concrete pole 9.00 metre long two coats of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
50
-
-
Material and labour for painting to steel tubular pole 9.00 metre long with one coat of red oxide on pole and two coats of synthetic enamel aluminium paint complete all as specified and directed by Engineer-in-Charge
150
-
-
Material and labour for numbering of pole no. Using radium sticker of superier quality with back of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge.
200
-
-
S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size all as specified and directed by Engr In charge
10
-
-
Supply and Repair/Replacement of hot press moulded SMC junction box door fixed with left side hinged inside dimension of 240x130x95 mm Fixed with cable terminals with one number of 16 Amp SP MCB incl fixed on pole with clamp nuts,bolts etc complete all as specified and directed by Engineer-in-charge.
20
-
-
Supply and Repair/Replacement for Timer switches Digital type programmable for street light connected to contactor complete all as specified and directed.
6
-
-
Supply and Repair/Replacement of power contactor 3 pole MCX-04 suitable for street light connected to timer complete all as specified and as directed.
6
-
-
Supply and Repair/Replacement of MCB SPN 6-32Amps,10 KA breaking capacity 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge.
20
-
-
Supply and Repair/Replacement of MCB TPN 32 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
10
-
-
Supply and Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.
10
-
-
Supply and Repair/Replacement of Building street light fitting Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete including taking down the u/s street light fittings complete all as specified and as directed.
10
-
-
M&L For repair and maintanance to solar street lights including cleaning of solar panel, filling of distilled water for battery,charging battery and making servicable complete all as specified and directed by Engineer - in - Charge.
20
-
-
Supply and Repair/Replacement of battery 12 volts 80 AH capacity suitable of solar light complete all as specified and directed by Engineer - in - Charge.
5
-
-
Supply and Repair/Replacement of LED Solar street light fitting 15 Watt including in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified and directed.
4
-
-
M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI strips 25 x 4 mm by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I all as specified and directed.
10
-
-
Supply and Repair/Replacement of LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp IP 65/66 protection complete in pole/post/wall position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s street light fittings complete all as specified and directed by Engineer - in - Charge.
10
-
-
Supply and Repair/Replacement of flood light LED luminaire white150 watt IP -65 flood light with highlighting architectural facade highmast/basket ball court/squach court/badmintion court light complete all as specified and directed including taking down the u/s flood light fittings complete all as specified and directed by Engineer - in - Charge.
6
-
-
Supply and fix of Integral LED aviation luminaire light comprising of aluminium housing with polycarbonate enclosure complete in highmast light in position by connecting the electrical connection and tightening the nut,bolts and clamps and all as specified and directed including taking down the u/s aviation light fittings complete all as specified and directed.
5
-
-
Supply only Lug aluminium suitable cable size of 16 to 50 sqmm complete all as specified and directed Engineer-in-Charge.
100
-
-
Supply only Lug aluminium suitable cable size of 70 to 150 sqmm complete all as specified and directed Engineer-in-Charge.
220
-
-
Supply and Repair/Replacement of decorative gate light moon (opal) type made up of high grade unbreakable polycarbonate material suitable for retrofit B22 base and 60 mm pole dia with 7 watt LED lamp complete all as specified and direcred by Engineer-in-Charge
10
-
-
Supply and Repair/Replacement of new generation post top energy saving environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed by Engineer - in - Charge.
4
-
-
Supply and Repair/Replacement of Garden Bollard light BGBOM 650 9W LED Bollards lightDie cast aluminium graphite grey powder coated GI Pipe Housing ,Mushroom shape opal acrylic diffuser if fixed in die-cast aluminium base for pleasant light output,LED mounted on die-cast aluminium base,IP-65, 240 Volt,Luminaire is provided with base plate and fixing holes for directely mounting on the concrete pedestal including taking down the u/s street light fittings complete all as specified and as directed.
10
-
-
Excavation in trenches for Soft/Disintegrated soil n.exc 1.5 m wide and n.exc 1.5 m deep and getting out for taking out/laying of UG cable LT of any size complete all as specified and directed.
262
-
-
Returning and filling in trenches incl spreading, levelling watering and raming in layer n.exc 25 cm complete all as specified and directed.
160
-
-
Removing of excavated mtrls n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
102
-
-
M & L for sand cushioning for LT cable laid in trenches using screened sand of approved quality as per SSR Part-I complete all as specified and directed.
79
-
-
S & F unreinforced pre-cast concrete cable covers class LV types 2 flat size 250mm x 150mm x 40mm including removal of old covers complete all as specified and directed.
6750
-
-
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 40mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
60
-
-
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
50
-
-
Supply and Repair/Replacement of Laying in trenches or passing through pipe,10 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed.
200
-
-
Supply and Repair/Replacement of Laying in trenches or passing through pipe,16 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed.
210
-
-
Supply and Repair/Replacement of Laying in trenches or passing through pipe,25 Sqmm 4 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed.
150
-
-
Supply and Repair/Replacement of Laying in trenches or passing through pipe,50 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed.
280
-
-
Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.
150
-
-
Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 1.5 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge.
100
-
-
Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 2.5 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge.
220
-
-
Supply and Repair/Replacement for Cable with copper conductor PVC round sheathed (flexible) 3 core 4 sqmm industrial cable complete all as specified and directed by Engineer-in-Charge.
190
-
-
Supply and Repair/Replacement for 63 AMP MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
2
-
-
Supply and Repair/Replacement for 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustmentof capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
6
-
-
Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to16 sqmm complete all as specified and directed Engr-in-Charge.
24
-
-
Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge.
24
-
-
Supply and Repair/Replacement of LED Solar street light fitting 15 Watt with inbuilt solar charge controller with street light bracket suitable size including taking down the u/s solar light fittings compleate all as specified and as directed. sensor complete
8
-
-
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 50mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.
30
-
-
Supply and Repair/Replacement of Laying in trenches or passing through pipe,70 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed.
150
-
-
Supply and Repair/Replacement of Laying in trenches or passing through pipe,95 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed.
200
-
-
Supply and Repair/Replacement of Laying in trenches or passing through pipe,120 Sqmm 3.5 core LT XLPE cable with stranded aluminium conductor heavy duty for 1100 volts grade cross sectional area complete all as specified and as directed.
180
-
-
Supply and Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
2
-
-
Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 25 KA with adjustable type against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
2
-
-
Supply and Repair/Replacement for 160 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustabletype against over load and short circuit conditions incl neutral adjustment of capacity suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.
3
-
-
Supply and Repair/Replacement of 415V 10KA 63 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer - in - Charge.
12
-
-
Supply and Repair/Replacement of 415V 10KA 40 Amp miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer - in - Charge.
10
-
-
M&L for earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground to a depth not less than 2.25 mtr below the normal ground level with top edge of earth plate not less than 1.50 mtr below the normal ground level and connected to GI wire 4.0mm dia by means of nut, bolt & washer and protected by 40mm dia GI pipe light grade and watering pipe of 20mm dia GI pipes light grade and connected to earth test point including necessary excavation, earth work, PCC chamber (1:3:6) type C-1 and 40 mm thick RCC pit cover in RCC (1:2:4) type B-1 using 6 mm dia MS round bars @ 150 mm C/C both ways all as shown in electrical plate No. 5 of SSR Part-I complete all as specified and directed.
5
-
-
Supply and Repair/Replacement of Onload change over switch 400 Amp four pole changeover, 415 Vac, 50 Hz by connecting the electrical connection and fixing on panal with nut, bolt,clamps complete all as specified and as directed by Engr-in-Charge.
2
-
-
Supply and Repair/Replacement installing, testing and commissioning factory made, floor mounted Indoor type LT panel board, cubicle type, suitable for 415 Volts, 3 Phase, 4 wire, 50 Hz, AC supply system, CPRI approved manufactures having bus bar chamber with insulated Copper bus bar four wire system, colour coded for each phase of rating as per under for phase and neutral, insulated on epoxy type insulators. The panel shall be dust and vermin proof, IP-54 class protection and made 2.0 mm of outer body and inner body 2.00 mm thick CRCA MS sheet , powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, both side opening type, including internal wiring with PVC insulated solid copper conductor cable, IS-694 marked, 1100 volts grade of appropriate size (but not less than 2.5 sqmm) including grouting of panel 30 cm above ground level by providing 60 cm long angle iron frame of size 40x40x5mm, welded on all the four corners, embedded in pcc 1:2:4 using 20 mm stone aggregate upto 30 cm complete all as specified and directed including the following accessories:- (Make :- CPRI approved) INCOMING :- (i)Thermal magnetic MCCB 4 pole,400 Amps 36 KA -01 No. (ii) Copper bus bar 500 Amps with insulator-04 Nos. (iii) Digital Voltmeter inbuilt selector switch, three phase Class 1 = 01 No. (iv) Digital Ammeter square dial CT operated 96mmx96mm, three phase Class1= 01 No. (v) Instrument control fuses and indication lamp LED Type set of three– one set OUTGOING :- (i) Thermal magnetic MCCB 4 Pole 200 Amps 36 KA -01 No. (ii) Thermal magnetic MCCB 4 Pole 160 Amps 25 KA -02 Nos. (iii) Thermal magnetic MCCB 4 Pole ,100 Amps 25 KA -02 Nos. (iv) Thermal magnetic MCCB 4 Pole 63 Amp 16 KA - 02 Nos (1 No for Spare) (v) MCB TPN 63A - 04 Nos. (vi) Indication lamp LED Type set of three– one set
1
-
-
Taking out panel door with old broken hinges and supply and fix with new MS hinges medium weight of 75mm long fix to panel & panel door with suitable nut & bolt /welding and Painting of LT panel with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed.
25
-
-
Supply and Fixing of Cable jointing kit for 1100 V (Earthed) grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 sqmm to120 sqmm complete all as specified and directed Engr-in-Charge.
20
-
-
Repeir/Replacement of panel mounted volt meter digital type 3 phase as per existing complete all as specied and directed.
10
-
-
Repeir/Replacement of panel mounted Ammeter digital type 3 phase as per existing complete all as specied and directed.
10
-
-
M&L for Cement Concrete 1:3:6 (40mm Graded Stone Aggregate) as in foundation of poles, Stays, etc. including Formwork (as/if required), complete all as specified and as directed.
1
-
-
Material and labour for Detecting the gas leakage, rectifying the defects by vacumizing and charging fresh mafron gas and commissioning and testing the window type air conditioner unit 1.5 Ton capacity complete all as specified and directed.
14
-
-
Ditto all as per item No. 65.00 above but of 2.0 Ton capacity
6
-
-
Ditto all as per item No. 65.00 above but of Split type AC 1.5 Ton Capacity.
15
-
-
Ditto all as per item No. 65.00 above but of Split type AC 2.0 Ton Capacity.
6
-
-
Ditto all as per item No. 65.00 above but of Water cooler 40/60/80 Ltrs. Capacity.
2
-
-
Ditto all as per item No. 65.00 above but of Water cooler 120/150/170 Ltrs. Capacity.
2
-
-
Ditto all as per item No. 65.00 above but of Refrigerator 165/180/230 Ltrs. Capacity.
2
-
-
Ditto all as per item No. 65.00 above but of Refrigerator 260/280/310/350 Ltrs. Capacity.
1
-
-
Ditto all as per item No. 65.00 above but of Deep Freezer of 260/280/310/350/500 Ltrs. Capacity.
1
-
-
Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.
4
-
-
Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves, disconnecting the suction and dischagre copper piping and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.
6
-
-
Material and labour for taking down Corroded body base tray etc of window type air conditioners and replacement of body base tray etc out of 18 SWG and other portion with MS sheet 20 SWG including motor mounting frame nuts and bolts suitable size painting and necessary insulation complete for 1.0 / 1.5 / 2.0 Ton capacity Air conditioner.
(Note : For dismantling compressor for body work and reassembling and gas charging as per site requirement shall be inclusive in quoted rate)
3
-
-
Material and labour for preparation of old painted surfaces of Refrigerator any capacity by complete scraping old painting an applying two coats of synthetic enamel paint on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
1
-
-
Material and labour for preparation of old painted surfaces of Water cooler any capacity by complete scraping old painting an applying two coats of synthetic enamel painting on outer surface (spray painting) as per existing colour and black colour on bottom portion such as compressor etc. over a coat of red oxide primer complete all as specified and directed.
2
-
-
S&F in replacement of old burnt compressor to new supply, install, test & commissioning Hermatically Sealed compressor of any type/ any size suitable for window type AC 1.5 Ton capacity duly charged with fresh Refrigerant gas etc. complete all as specified & directed by Engineer-in-Charge.
3
-
-
Ditto all as per item No 79.00 above but of 2.0 Ton capacity
2
-
-
Ditto all as per item No 79.00 above but of Split type AC 1.5 ton capacity
5
-
-
Ditto all as per item No 79.00 above but of Split type AC 2.0 ton capacity
2
-
-
Ditto all as per item No 79.00 above but of Refrigerator 100/165/180/210 Liters Capacity.
2
-
-
Ditto all as per item No 79.00 above but of Refrigerator 260/280/310/350 Liters Capacity.
1
-
-
Ditto all as per item No 79.00 above but of Water coolers 40 / 60 /80 Liters capacity
2
-
-
Ditto all as per item No 79.00 above but of Water coolers 120/150/170 Liters capacity
1
-
-
Ditto all as per item No 79.00 above but of deep freezers of capacity 310ltrs/410Ltrs/500 ltrs Capacity
1
-
-
S&F in replacement metal plug top Single pole & Neutral and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
20
-
-
S&F in repalcement metal enclosures with clad socket & plug top Single pole and neutral enclosure with a two pin and earth plug and socket complete including of MCB SP 25 Amps 240 volts complete all as specified and directed.
8
-
-
Removing the existing unserviceable burnt fan motor from window type AC of capacity 1.0 / 1.5 / 2.0 Ton and replacing the same with brand new fan motor of same capacity including connecting up and testing complete all as specified and directed.
5
-
-
Supply and fix fan motor suitable for water cooler of any capacity including removing old fan motor and testing complete all as specified and directed.
2
-
-
Supply,fixing and testing fan blade suitable for window/split type Air conditioner of 1.0 / 1.5 / 2.0 Ton capacity including removing old fan blade complete all as specified and directed.
4
-
-
Supply, fixing and testing fan blade suitable for water cooler of any capacity including removing old fan blade complete all as specified and directed.
3
-
-
supply & fix in repairs blower drum suitable for window type Air conditioner of 1.0 Ton / 1.5 Ton / 2.0 Ton capacity complete all as specified and directed.
3
-
-
supply & fix in repairs of front cover grill suitable for window type AC 1.0 Ton / 1.5 Ton / 2.0 Ton capacity AC of various complete all as specified and directed.
2
-
-
supply & fix in repairs running capacitor 50 MFD complete all as specified and directed.
20
-
-
supply & fix in repairs running capacitor 60 MFD complete all as specified and directed.
20
-
-
Supply and fix in replacement of selector switch push button type for window type AC any make 1.0 Ton / 1.5 Ton / 2.0 Ton capacity complete all as specified and directed.
6
-
-
Ditto all as per item No. 98.00 above but rotary type
4
-
-
Supply and fix in replacement of thermostat switch for window type AC of capacity 1.0 Ton / 1.5 Ton / 2.0 Ton capacity complete all as specified and directed.
7
-
-
Supply and fix in replacement of thermostat switch for split type AC of capacity 1.5 Ton / 2.0 Ton capacity complete all as specified and directed.
5
-
-
Supply and fix in replacement of thermostat switch for Refrigerator of any capacity complete all as specified and directed.
2
-
-
supply & fix in repairs thermostat switch for Water Cooler of any capacity complete all as specified and directed.
4
-
-
supply & fix in repairs over load relay suitable for Window type AC of 1.0 Ton / 1.5 Ton / 2 Ton capacity all as directed.
4
-
-
supply & fix in repairs over load relay suitable for water cooler of any capacity all as directed.
3
-
-
supply & fix in repairs over load relay suitable for Refrigerator of any capacity all as directed.
2
-
-
supply & fix in repairs Float valve suitable for Water cooler of any capacity complete all as specified and directed.
3
-
-
Supply fixing and clamping jointing copper tubing for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing through and making good to the disturbed surface complete all as specified and directed.
30
-
-
Supply and laying in repairs PVC pipe 20 mm dia heavy duty for drain out condensing water of split AC including cutting of floor / opening of hole in wall and making good after laying of pipe etc match the existing surface complete all as specified and directed.
120
-
-
supply & fix in repairs push cock / lifting cock of 15 mm bore in repair for water cooler of any capacity complete all as specified and directed.
4
-
-
supply & fix in repairs PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 cms for connection of water coolers complete all as specified and directed.
10
-
-
supply & fix in repairs GI water tray 2 mm thick for window type AC any capacity with out let system connection provided with PVC pipe of 20 mm dia up to 3 meter length connecting to drain pipe complete all as specified and directed.
4
-
-
supply & fix in repairs PVC drain pipe with necessary saddles of 25 mm size to be used as out let drain to be fixed complete all as specified and directed.
100
-
-
supply & fix in repairs new magnetic gasket for refrigerator of 165 / 286 / 310 liters complete all as specified and directed.
3
-
-
Taking out old unserviceable condenser coil of 1.5 Ton window type AC any make with sins cutting in let outlet connecting copper pipe and providing new condensor coil with sins and connecting inlet outlet copper pipe by bracing and replacement of nut bolts etc complete all as specified and directed by Engineer-in-Charge.
4
-
-
Ditto all as per item No. 116.00 above but for 2.0 ton window type AC complete all as specified and directed by Engineer-in-Charge.
2
-
-
Ditto all as per item No. 116.00 above but for 1.5 ton Split type AC complete all as specified and directed by Engineer-in-Charge.
5
-
-
Ditto all as per item No. 116.00 above but for 2.0 ton Split type AC complete all as specified and directed by Engineer-in-Charge.
2
-
-
Removing electronic unserviceable circuit boards from window type AC 1.5 ton / 2.0 Ton capacity and replacing with new circuit boards and connecting with system with replacing remote control hand set and testing complete all as specified and directed.
6
-
-
Ditto all as per item No 57.00 above but for 1.5 Ton / 2.0 Ton Split type AC complete all as specified and directed.
10
-
-
supply & fix in repairs blower fan motor capacitor 4 MFD complete all as specified and directed.
20
-
-
supply & fix in repairs blower fan motor capacitor 6 MFD complete all as specified and directed.
20
-
-
supply & fix in repairs electric bulb suitable for refrigerator of any capacity screw type / pin type complete all as specified and directed.
5
-
-
supply & fix in repairs Air filter for window type AC of any capacity and type complete all as specified and directed.
8
-
-
Material and labour for replacement of damaged outer cover for window type Air conditioner of any capacity and size made out of aluminium sheet of 20SWG all as specified by Engineer-in-Charge.
3
-
-
supply & fix in repairs over load protector for 1.0 /1.5 /2.0 Ton capacity split type Air Conditioner complete all as specified and directed.
5
-
-
Supply and fix in repairs sensor remote plate(PCB) suitable for 1.5/2.0 Ton capacity split type AC etc. complete all as specified and directed by Engineer-in-Charge.
6
-
-
Supply of sensor remote handset suitable for 1.5/2.0 Ton capacity split type AC etc. complete all as specified and directed by Engineer-in-Charge.
5
-
-
supply & fix in repairs multipurpose door lock with duplicate key of refrigerator of any make & capacity etc complete all as specified and directed by Engineer-in-Charge.
4
-
-
M & L for Overhauling of ceiling fan 1200 / 1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including replacement of worn out nut bolt / washer, rubber real bush, canopy and reassembling the fan complete after one coat of white enamel paint and hanging on its original / new position as directed by Engineer - in - Charge.
Note:- MS nut bolts with spilt pin, Ball bearing and Gun metal bush will be paid and measured seperately.
150
-
-
Supply only for above item No. 131.00 for MS Nut bolts with split pin and rubber bush as per sample and as directed by Engineer-in-Charge.
150
-
-
Supply only for above item No. 131.00 for Ball bearing suitable size of ceiling fan 1200/1400 mm complete all as specified and directed by engineer in charge.
150
-
-
Supply only for above item No. 131.00 for gun metal bush suitable for ceiling fan any type and size including removing old one as specified and directed by engineer in charge.
150
-
-
Supply and Fixing of white powder coated fan pipe 2 feet complete all as specified and as directed.
20
-
-
M & L for Overhauling of ceiling fan 1200 / 1400 mm sweep at site and removing of old grease from bearing of ceiling fan and re-filling new grease including opening the body cover of fan any type and make and cutting the existing worn out winding with out damaging the stator removing the coil insulation and putting new insulation of polyster paper, winding with super enameled copper wire of suitable gauge with correct number of turns of auxillary and main winding and varnishing and backing complete including the soldering new lead of copper wire testing complete including transportation to work shop and back all as directed
Note:- a) Contractor have to make the arrangement for testing of Rewinded fan upto 24 hrs in case of failure to above said testing a penalty of Rs 200/- per fan is deducted from contractors due and rewinding of same once again is bonded.
b) Fan should be return to MES yard after rewinding within 10 day from the date of issue otherwise a penalty of Rs. 10/- per day per fan is deducted from contractor due.
150
-
-
Supply and fixing for mild steel SD Hook hanger with fasteners M10X75 mm for hanging ceiling fan complete all as specified and as directed.
20
-
-
Supply and fixing of heating element 1.5/2 KW of sutable size of existing storage type solar water heater of compatible type including making all connections by replacing inter connecting copper conductor cables and removal of old unserviceable elements all as directed by Engineer - in - Charge.
5
-
-
Supply and fixing of Vacuum solar tube suitable size of existing storage type solar water heater 200 to 500 LPD of compatible type including making all connections by replacing old vacuum tube all as directed by Engineer - in - Charge.
10
-
-
Supply and fixing in replacement step regulator electronic fan regulator flush type on existing phenolic laminated sheet as specified and directed by engineer in charge.
50
-
-
Supply and fixing in replacement fan capacitor 2.5 mfd 240 V AC supply as specified and directed by engineer in charge.
200
-
-
M&L for Taking down and refixing at site Exhaust fan of 250/300mm sweep including opening of fans and cutting down burnt winding, and re-winding with new super enameled copper winding of same gauge as per existing winding, varnishing, drying, replacement of condenser, ball bearing etc and re-assembling the same including necessary transportation etc complete for all as specified and directed.
20
-
-
Ditto all as per item No 143.00 above but of Exhaust fan 380/450mm sweep capacity complete all as specified and directed.
10
-
-
Repair/replacement of metal fan blade 300 mm sweep rust proof 4 number of blades complete all as specified and directed
5
-
-
Repair/replacement of metal fan blade 380 mm sweep rust proof 4 number of blades complete all as specified and directed
5
-
-
Evaluation Notes How It Works ?