Military Engineer Services Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Military Engineer Services - MES Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date9 Sep 2024
Closing Date5 Nov 2024
Tender Amount₹ 12,25,00,000
Costs
EMD
₹ 9,35,500Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_673273_1Bid Award Id
ViewTender No
800588/GNR/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Lump sum price worked out by the contractor for "INTERNAL ELECTIFICATION" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.33
1
-
5610037.58
... More
Lump sum price worked out by the contractor for "ROAD, PATH, CULVERT" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.36
1
-
6118734.11
... More
Lump sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.37
1
-
622845.47
... More
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No.39
1
-
1527816.68
... More
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 40
1
-
582242.36
... More
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 42
1
-
1365897.78
... More
Sch 'A' PART-X (MISCELLANEOUS ITEMS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.
-
-
-
... More
INTERNAL WATER SUPPLY
OR Md Accn Supply and fixing of 15 mm dia fancy type chromium plated bib taps with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
56
-
-
... More
Supply and fixing of 15 mm dia fancy type chromium plated two way bib taps with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
56
-
-
... More
Supply and fixing of 15 mm dia fancy type chromium plated wall mixer of 2 in 1 system with provision with central spout and connection for over head shower with divertor liver ISI marked complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
112
-
-
... More
Supply and fixing of 15 mm dia fancy type chromium plated angular stop cock with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
448
-
-
... More
Supply and fixing of 15 mm bore Overhead shower of 114 x 114 mm of square shape single flow with rubit cleaning system ABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
112
-
-
... More
S&F 15 mm bore health faucet (ABS Body) with 1000 mm long flexible mild steel tube 15 mm dia with wall hook and complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
56
-
-
... More
Supply and fixing of 15 mm bore Central hole Wash basin mixer with regular spout with popup waste system with 450 mm long braided hoses and fixed complete all as specified and directed. Make:- Jaquar Queen Series Cat Part No QQT-7167B or techno commercial equivalent of any make specified in Appx 'B'.
112
-
-
... More
Supply and fixing of 15 mm bore Sink tap with Regular swinging spout (Wall mounted Model) With Connecting Legs & wall fllanges and fixed complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
56
-
-
... More
OFFR's Md Accn Supply and fixing of 15 mm dia fancy type chromium plated two way bib taps with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
12
-
-
... More
Supply and fixing of 15 mm dia fancy type chromium plated angular stop cock with wall flange,screwed for iron pipe or CPVC pipes or for brass ferrule and fixed complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
52
-
-
... More
Supply and fixing of 15 mm bore CP wall mixer of 3 in 1 system with provision for hand shower and over head shower and including 1.5 m long tele shower screwed for iron pipes or CPVC pipes or for brass ferrule and fixed complete all as specified and directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
12
-
-
... More
Supply and fixing of 15 mm bore Sink tap with Regular swinging spout (Wall mounted Model) With Connecting Legs & wall fllanges and fixed complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
4
-
-
... More
Supply and fixing of 15 mm bore Overhead shower of 150 x 150 mm of square shape single flow with rubit cleaning system ABS body crome plated with grey face plate with arm having swivel joint chromium plated complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
12
-
-
... More
Supply and fixing of 15 mm bore health faucet (ABS Body) with 1200 mm long flexible mild steel tube 15 mm dia with wall hook and complete all as specified and as directed. Make:- Jaquar/Essco Series or techno commercial equivalent of any make specified in Appx 'B'.
12
-
-
... More
Supply and fixing of 15 mm bore Central hole Wash basin mixer with regular spout with popup waste system with 450 mm long braided hoses and fixed complete all as specified and directed. Make:- Jaquar Queen Series Cat Part No QQT-7167B or techno commercial equivalent of any make specified in Appx 'B'.
12
-
-
... More
INTERNAL ELECTRIFICATIONS
Supply and fixing of TV sockets complete with all accessories complete all as specified and as directed.
64
-
-
... More
Supply and fixing of RJ 11 Gang with shutter (Telephone Jack) complete with all accessories complete all as specified and as directed.
5
-
-
... More
Supply & fixing of PVC metal braided connection pipes for hot water supply with brass adopters 15 mm dia and 450mm long complete all as specified and as directed.
128
-
-
... More
Supply and fixing of LED batten suitable for indoor application 20 W, 4' length , wall mounted with aluminium housing, end cap made of ABS plastic of white colour finish and high efficiency translucence (HET) diffuser and integral electronic driver including two point surface mounting on wall/ ceiling and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed
572
-
-
... More
Supply and fixing load line distribution board TPN vertical, 4 way double door type, fixed on wall semi flush with incoming MCCB 4 poles 125 Amps, 16 KA, busbars , neutral link, blanking plates complete with all accessories all as specified and as directed by Engineer-in-Charge. Note: Outgoing MCBs shall be measured and paid separately
1
-
-
... More
Supply and fixing of LED lamp B22 base 10 W, min lumen output 950 lumens at 6500 K CCT with batten lamp holders complete all as specified and as directed.
316
-
-
... More
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete with twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed
128
-
-
... More
M & L for inverter point wiring for one light, ceiling fan and 5 Amp socket for each room with 2.5 sqmm,PVC insulated, unsheathed, single core multistandard copper conductor cable( FRLS), 1100 volts grade including 2.5 Sqmm PVC insulated, unsheathed, copper conductor cable for earth continuity wire to be drawn through in and including PVC conduit medium grade ISI marked with its accessories upto the main DB and 15 A switch socket combination with gang box flushed in wall for inverter power supply complete all as specified and as directed.
60
-
-
... More
M&L for earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm buried directly in ground vertically to depth not less than 2.25 m below normal ground level with top edge of the earth plate at a depth not less than 1.5 m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
45
-
-
... More
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to and including earth lead of galvanized strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of SSR Part-I with connected to earth test point & to main switch board with & including adequate quantity of charcoal and common salt alround earth plate & 40 mm dia GI pipe medium grade for earth lead protection pipe fpr suitable length and GI pipe 20 mm dia medium grade for watering pipe with funnel & wire mess including necessary earth work and PCC (1:3:6) type C1 for earth pit and 40mm thick precast RCC cover in cement concrete 1:2:4 type B1, with 3 Nos 8mm dia TMT bars both ways with 12mm dia round bar handle complete all as specified and directed NOTE: Item includes the cost of earth lead and GI protection pipe up to 7.5 m. GI strip and protection pipe beyond 7.5 m shall be measured and paid for separately.
16
-
-
... More
M & L for drawing 12 pair /multi core coated copper telephone cable including PVC conduit of size 20mm complete all as specified and as directed.
25
-
-
... More
M &L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etcas required 4mm complete all as specified and directed.
50
-
-
... More
Supply and fixing hot water pipe duly insulated with glass wool and aluminium cladding complete in all respect of size 20mm bore all as specified at site complete all as specified and directed.
16
-
-
... More
Supply and fixing of 30 W LED security light fitting made out of pressure die cast aluminium powder coated housing high impact resistant 4mm thick toughened glass cover and matrix of power LEDs inbuilt electronic driver up to 4KV surge protection fitted with adjustable pole adapter to enable on site tilt angle setting depending on road geometry CCT5500-6500 CRI greater than 70 , input power 30W output operating voltage 140-280V with connection by three core PVC insulated multistranded copper conductor sheathed cable of size 1.0 sq mm fixed with & including bracket made of GI pipe 40mm bore light grade, 1.6 mtr long bent to shape required with 2 no MS clamps of suitable size and length, nuts & bolts complete all as specified and as directed.
36
-
-
... More
M&L for sub main wiring with Two runs of 4.0 Sqmm size main cable and one run of 4.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specified and as directed
100
-
-
... More
M&L for sub main wiring with Two runs of 6.0 Sqmm size main cable and one run of 6.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specified and as directed
400
-
-
... More
M&L for sub main wiring with four runs of 10.0 Sqmm size main cable and one run of 10.0 Sqmm size earth continuty conductor of single core PVC insulated but unsheathed FRLS cable multi standed copper conductors, 1100 volts grade, IS-694 marked all drawn through and including suitable size rigid PVC conduit pipe medium grade ISI marked & fittings/ accessories all fixed to the surface of wall/ceiling complete all as specified and as directed
100
-
-
... More
Note for item No 12.14 to 12.16: The above mentioned specefied runs of single core cables and specefied runs of earth continuity conductors and the relevant conduit with accessories shall be measured as one runs length. The small extra lengths required for loops etc for connection in DBs shall deemed to be included in quoted rate and only the cable covered in conduit shall be measured.
-
-
-
... More
M&L sheet metal enclosure, flushed in wall single pole and neutral, double door, 6 way, 240 Volts with PVC MCB blanking plates, stove enamelled, dust and vermin proof suitable for incorporation of MCBs and isolators etc., complete all as specified and as directed
4
-
-
... More
ROAD & FOOT PATH
M&L for 150 mm thick WMM (Wet Mix Macadam) (compacted thickness) laid in two layers of 75mm thick each conforming to grading given in table 400-13 & physical requirement given in table 400-12 spread by mechanical means & rolled by using 8-10 ton vibrator power roller over compacted sub grade surface of soling as specified in clause 406 3.5 of MORTH specification and necessary lateral support and formwork if required complete all as specified and directed.
403
-
-
... More
M&L for cement concrete bed to drain pipes in PCC 1:3:6, type C2 (using 40mm graded stone aggregate), for 450mm bore drain pipe including packing under and haunching against the sides of pipes with concrete after they are laid and tested complete all as specified and directed.
40
-
-
... More
EXTERNAL WATER SUPPLY
Supply, installation, connecting and testing sluice valve, non rasing type spindle, cast iron body & wedge with Bronze wedge ring on both side, gland packing, class - PN 1.6 with flanged ends drilled suitable for bore of pipe 100 mm ISI marked (IS:14846:2000) having S.S. spindle with iron wheel at top, complete with nuts bolts washers rubber gasket etc all as specified and directed.
2
-
-
... More
M&L for cutting of existing CI/DI/GI pipe and insterting and including Tee of size 100mm x100mm x100mm for making suitable connection complete all as specified and directed.
Note:- Quoted unit rate of this item includes the cost of excavation and earth work and refilling required for completion of job.
2
-
-
... More
EXTERNAL ELECTRIFICATIONS
Supplying, installing, testing and commissioning of AC 3 phase, 50 HZ, 160 KVA capacity transformer, step down, outdoor type, 11000/433 volts (at no load) with system voltage 12KV all as per IS 1180 (Part 1) :2014, copper wound, oil immersed, naturally cooled with external cooling tubes, ONAN Cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group-4) with neutral brought on secondary (LV) side & having tappings in equal steps of 2.5 % from (+) 5% to (-) 10% on primary side by means of hand operated off load tap changing gear, so as to change/correct L.T voltage on secondary side including provision of all necessary / standard fittings all as per IS:2026 & IEC 76 Latest ammendments and confirming to BEE 5 Star Rating (Level II ) as per IS 1180 (Part 1):2014
1
-
-
... More
(a) The core shall be stack/wound type of high grade Cold Rolled Grain Oriented or Amorphous Core annealed steel lamination having low loss and good grain properties, coated with hot oil proof Inter layer insulation of Nomex /Epoxy dotted Kraft Paper, bolted together and to the frames firmly to prevent vibration or noise. The core shall be stress relieved by annealing under inert atmosphere if required.The complete design of core must ensure permanency of the core loss with continuous working of the transformers. LV winding shall be such that neutral formation will be at top. Current density for HV and LV winding should not be more than 2.8 Ampere per sq mm.
(b)The maximum allowable losses at 75 °C for 11/0.433 kV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss 416 watts and 1281 watts respectively without any positive tolerance all as per specified in IS 1180 (Part-1):2014 for energy efficient rating 5star.
(c) Overload capacity of transformers shall be suitable for loading as per IS 6600
(d) The percentage impedance of transformers at 75 °C for 160 kVA shall be as per Table 6 of IS 1180 (Part-1) : 2014
-
-
-
... More
(e) Transformer tank construction shall conform in all respect to clause 15 of IS 1180(Part-1):2014. The internal clearance of tank shall be such, that it shall facilitate easy lifting of core with coils from the tank without dismantling LV bushings. All joints of tank and fittings shall be oil tight and no bulging should occur during service. Inside of tank shall be painted with varnish/hot oil resistant paint. The top cover of the tank shall be slightly sloping to drain rain water. The tank plate and the lifting lugs shall be of such strength that the complete transformer filled with oil may be lifted by means of lifting shackle. Manufacturer should carry out all welding operations as per the relevant ASME standards. The transformer tank shall be of robust construction and shall be built up of electrically tested welded mild steel plates of thickness of 6 mm for the bottom and top and not less than 4 mm for the sides for distribution transformers with Tolerances as per IS-1852.The space above oil level in the tank shall be filled with dry air or nitrogen conforming to commercial grade of IS 1747. The tank shall further be capable of withstanding a pressure of 0.8kg/sq.cm and a vacuum of 0.7 kg/sq.cm (g) without any deformation.
(f) Audible sound levels for 160KVA, 50Hz liquid immersed distribution transformers shall be 56 decibels (NEMA Standards)
(g) One cable box on primary H.V side having cable glands suitable for 95 Sqmm 3 core XLPE 11 KV H.T cable consisting of 3 Nos porcelain H.T bushings with brass/ gun metal bushing rods confirming to IS 2099 and IS 3347 for outdoor bushing complete with nuts and washers. HT Cable box should prevent the ingress of moisture into the box due to rain water directly falling on the box. The cable box on HT side shall be of the split type with faces plain and machined and fitted with Neo-k-Tex or similar quality gasket and complete with brass wiping gland to be mounted on separate split type gland plate with nut-bolt arrangement and MS earthing clamp. The bushings of the cable box shall be fitted with nuts and stem to take the cable cores without bending them. The stem shall be of copper with copper nuts. The cross section of the connecting rods shall be stated and shall be adequate for carrying the rated currents. On the HV side the terminal rod shall have a diameter TS for 3 Phase DT 11 of not less than 12 mm. The material of connecting rod shall be copper. HT Cable support clamp should be provided to avoid tension due to cable weight.
-
-
-
... More
(h) One cable box on secondary (LV) side consisting of 4 Nos porcelain bushings complying to IS 7421 with GM bushing rods complete with GM nuts, and washers with cable gland suitable for reception of outgoing L.T. PVC sheathed armoured cables of size 2 x 300 sqmm 3.5 core . having non-magnetic material gland plate with appropriate sized single compression brass glands on LV side to terminate 1.1 kV/single core XLPE armoured cable.
(j) The bushing rods and nuts shall be made of brass material 12 mm diameter for both HT and LT bushings. The bushings shall be fixed to the transformers on side with straight pockets and in the same plane or the top cover . The tests as per latest IS 2099 and IS 7421 shall be conducted on the transformer bushings.
(k) OIL CONSERVATOR: The provision of conservator is mandatory with oil gauge, air release plug and breathing device with a drain plug and a filling hole 32 mm (1¼”) normal size thread with cover. The dehydrating agent shall be silica gel. The moisture absorption shall be indicated by a change in the colour of the silica gel crystals which should be easily visible from a distance. Volume of breather shall be suitable for1Kg of silica gel conforming to IS 3401. The total volume of conservator shall be such as to contain 10% quantity of the oil. Normally 3% quantity the oil shall be contained in the conservator.
(l) The radiators can be tube type or fin type or pressed steel type to achieve the desired cooling to limit the specified temperature rise.
(m) Transformer to be painted with poly urethene/powder caoted (color light gray & DA gray) paints over anti corrosive primer & shall be free from runs, sags, wrinkles, patchiness, brush marks or other defects. All primers shall be well marked into the surface, particularly in areas where painting is evident and the first priming coat shall be applied as soon as possible after cleaning. The paint shall be applied by airless spray.
-
-
-
... More
(n) One No 100 mm dia dial type thermometer vapour pressure type having range 0-120 degree centigrade with temp reading pointer, max temp indicator and resetting device
(o) Rating plate with terninal markings.
(p) Two earthing terminals on tank/tank cover to facilitate fixing of 32 x 6 m GI earth strip.
(q) Lifting lugs.
(r) Four plane solid cast steel detachable rollers.
(s) First fill of fresh transformer oil conforming to IS-335, BS148, D-1473, D-1533-1934IEC Pub296 and tested upto 40 KV dielectric strength. Use of recycled oil is not acceptable. The specific resistance of the oil shall not be less than 2.5X10¹² ohm-cm at 27°C when tested as per IS 6103.
(t) Extra bushing for neutral outside the L.T cable box for providing independent earthing for neutral.
(u) Provision of 2 Nos danger boards 250 x 200 mm size made out of 1.6 mm thick M.S. plate, vitreous enameled white, with letters. figures of voltage and conventional skull and bones in signal red colour , one at H.T side and other on L.T side.
(v) Any other fittings / accessories so as to conform the whole transformer to IS 1180 (Part 1): 2014
-
-
-
... More
(w) The DistributionTransformers to be supplied against this Specification shall be suitable for satisfactory continuous operation under the following climatic conditions as per IS 2026(Part-I):
(i) Location : Gandhinagar
(ii) Maximum ambient air temperature (°C) : 50 °C
(iii) Minimum ambient air temperature (°C) : 5 °C
(iv) Maximum average daily ambient air temperature (°C) : 42 °C
(v) Maximum yearly weighted average ambient temperature (°C) : 32 °C
The temperature rise over ambient shall not exceed the limits given below:
(i) Top oil temperature rise measured by thermometer : 35 °C
(ii) Winding temperature rise measured by resistance method : 40 °C
-
-
-
... More
Construction of brick masonry platform in cement mortar 1:4 of size 3 x 2.5 x1.5 m for outdoor type transformer having sides finished with brick work with plaster complete with PCC foundation of 1:5:10 & PCC platform at top with 30 cm thick of PCC 1:5:10 and 10 cm thick of PCC 1:2:4 and having brick steps at one side, complete with XPM jali duly welded with angle iron of size 50 mm x 50 mm x 6 mm all around upto 0.6 metre, including excavation and earth work in any type soil , returning filling in and removal of surplus soil upto 50 metre complete all as shown on drawing or as directed.
1
-
-
... More
M&L for complete set of LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing, heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection fixed to pole complete comprising of the followings:-
16
-
-
... More
(i) bracket made out of light grade, Galvanised steel tube, 40mm bore, 1.5 Mtr length, bent to 120 degree for fixing street light fitting at the top, fixed to pole with necessary clamps made out of FI 40mm x 4mm with nuts & bolts (ii) sintex juction box of size 230x170x105mm compete with one SP MCB of 6 Amps (iii) PVC insulated, sheathed copper conductor cable of size 1.5 Sqmm, 3 core, 1100 volts grade, multistranded, passing throuth pipe, fixed on pole/wall from juntion box to street light fitting
-
-
-
... More
Supply, installation, commissoning and testing, feeder pillar board, Kiosk type, LT (415 Volts, 50 Hz , 3-phase, 4 wire supply), plinth mounted, factory made, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 50mm x 50mm x 5mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet powder coated with front & back hinged opening, rubber lining, locking arrangement, painted externally and internally with two coats of synthetic enamel gray paint (First Quality) over a coat of red oxide primer, grouting panel through angle iron, 0.20 mtr in ground and 0.5 mtr over the ground including excavation & earth work in any type of soil and PCC (1:3:6) type C-2 using 40mm graded stone aggregate complete comprising of the followings:-
5
-
-
... More
Incoming supply :- (i) Aluminium bus bar 200 amps rating of 04 strip - 01 No (ii) MCCB, adjustable thermal release (0.7 ti 1.0 In) and fixed megnatic type suitable for 10.0 In , 4 pole, AC, 415 volts, 125 Amp rating, 16 KA rupturing capacity - 01 No (iii) Digital type multifunctional metershowing PF, V, I, Hz etc. - 01 No
(iv) Indicatiing lamp LED type for R-Y-B - 3 Nos. (b) Outgoing supply:- (i) MCCB, adjustable thermal release (0.7 ti 1.0 In) and fixed megnatic type suitable for 10.0 In, 3 pole, AC, 415 Volts, 63 Amp rating, 16 KA rupturing capacity - 04 No (ii) Cable connection through straight plugs 63A, 415 Volt - 04 Nos Cat No. 058705 Tempra Pro IP-67 and Panel mounting Socket 63 Amp, 415 Volt - 04 Nos Cat No. 058725 Tempra Pro IP-67.
-
-
-
... More
Supply Installtion Testing and Commissioning (SITC) of Outdoor type factory made Automatic Power Factor Correction (APFC) of capacity 80 KVAR fabricated out of 2mm thick MS sheet, openable front fitted with low watt loss capacitors to improving power factor, suitable for 415 votls, 50 Hz, 3 phase, 4 wire with and including the following :-
(a) Digital multi functional meter showing current, voltage, power factor, frequency with suitable CT's ratio - 01 No (b) Indicators RYB - 1 Set (c) Capacitor step on indication lamps - 04 Nos (d) Auto-manual selector switch - 01 No (e) On/Off push buttons for manual mode-01set
1
-
-
... More
(f) Micro processor based APFC relay 4 steps having all the required features-01 No
(g) MCB TP 16 Amp - 04 Nos (h) Aluminium busbars of suitable capacity TPN-01 Set (j) Internal wiring of panel board with copper cable. (k) MCCB 25KA/ 3 pole, 50 Hz, 160 Amp-01 No (l) 2.5 Sqmm 2 core LT armored cable for connection of main panel CT with APFC panel (m) LT power capacitor cylindrical capacitor 20 KVAR, 440 volts, 3 phase, 50 Hz-01 No (n) Capacitor duty contactor capacity 40 KVAR, 415 votls, 3 phase, 50 Hz-01 No (o) Capacitor duty contactor capacity 10 KVAR, 415 Votls, 3 Phase, 50 Hz-02 Nos
-
-
-
... More
Supply, installation, commissoning and testing, LT Panel board, cubical type, (415 Volts, 50 Hz , 3-phase, 4 wire supply), floor mounted, factory made and tested, outdoor type, weather and vermin proof (Protection Class IP-54) made out of 40mm x 40mm x 6mm angle iron frame and 3.15 mm thick MS Sheet CRCA sheet with front & back opening type of adequate size for housing LT switchgear ahd measuring instruments duly powder coated after seven tank process on both sides incl internal wiring in the panel with suitable size of PVC multistranded copper cable 1100 volts grade IS-694 and complete comprising of the followings:-
1
-
-
... More
Bus bar 400 Amps. 4 Pole aluminium (50 KV) (a) Incoming supply:- (i) MCCB, Thermal magnetic seting, 4 pole, AC, 415 volts, 320 Amp rating, 35/36 breaking capacity, 50 Hz - 01 No (ii) LED Indicatiing lights for R-Y-B - 01 Set (iii) Panel mounted multifunction meter suitable to operate on and incl CT in accuracy class 1.0, suitable 3 Phase CT network CT primary programmable, three line baklit display of phase to phase rating phase to neutral voltage current active power KW, KVAR, KVA, PF Frequancy. (b) Outgoing supply:- (i) MCCB, thermal and meganitic setting, 4 pole, AC, 415 Volts, 100 Amp rating, 25 KA breaking capacity - 05 No (C) Time switch auto dusk dawn (Nature) 3 Phase including connection for operation of 20 x 60 watt lights.
-
-
-
... More
Supplying, installing, testing and commissioning, of factory made LT Meter box, wall mounted board made out of CRCA Sheet of 2mm thick indoor type totally enclosed weather, dust and vermin proof with front opening hinged door and locking arrangement mounted on MS flat iron (40x6mm and 6" long) 04 No clamp welded to 40mm x 40mm x 6mm size angle iron frame alround panel duly grouted on wall, 415 volts, 3 phase, 4 wire AC 50 Hz having aluminium bus bar for phase and the neutral insulated with PVC sleeves, space for fixing single phase KWH electric meter of suitable capacity 04 Nos, copper lugs, spacers, mounting channels, rubber gasket, locking knobs, hylam sheet pieces, nuts and bolts, washers etc. and suitable size single core copper wire connections suitable compartments and epoxy powder spray paint with primer complete all as specified including the following accessories :-
16
-
-
... More
Incoming - (a) MCCB 415 Volts, 4 Pole, 25 KA breaking capacity of 125 Amps - 01 No (b) R-Y-B Phase, LED indicating lamp - 03 Nos (c) 150 Amp main Aluminium bus bar. multifunction meter with suitable CT. Outgoing - (a) MCB, SPN, 63 Amp, 10 KA - 04 Nos (b) Space for mounting single phase prepaid meter-04 Nos (c) Copper cable 10 Sqmm wire and open terminals for all feeders. Note : Quarter No to be mentioned in respective meter on aryclic plate & cost of aryclic plate to be included in quoted rate.
-
-
-
... More
M&L for sand cushioning to cables with Dry and fine sand and punning to provide required cover to UG cables complete as per SSR Part-I all as specified and directed. Note: Punned down thickness shall only be measured and paid.
130
-
-
... More
Supply, installation, testing & commssioning of HT 11kV,3Ph,50Hz totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630A, with 02 Nos cercit breaker or SF 6 CB ( type LVV ) with 01 set of CT ratio 30A/1A, Class 5P10,2.5VA & 01 No. STC 21kA for 1Sec ,IAC 21kA for 1sec ,CU busbar,Type 2 ways motor operated,outdoor,non-extensible, L comprising of 4 way ( 1 LBS+2 VCB) in a single unit ,rated power frequency voltage 28kV,rated impluse withstand voltage 75kV,rated current for ring main feeder -630A,rated current for Circuit breaker SF6 CB 630A,short time current (ik)-21kA for 3sec,rated short making current 50kV,ambient temperature (-5deg to +55deg celsius),design ambient temperature (40degree C),with IP 54 Each Circuit breaker or SF 6 CB includes and complete comprising of the followings:-
1
-
-
... More
(i) motorised Circuit breaker or SF 6 CB position ON-OFF, ii) manual disconnector with three position switches ON-OFF-EARTH, iii) Self Powered relay for over current protection and earth fault protection, iv) three phase definite time over current and short circuit protection with variable tripping times (ANSI 50/51). V) 3phase over current protection with selectable inverse time characteristics and definite time short-circuit current element (ANSI 50/51), (ii) definite time earth fault current and earth short circuit protection by internal calculation (ANSI 50N/51N) , vii) earth fault current protection with selectable inverse time characteristics and instantaneous short circuit current element (ANSI 50N/51N) viii) LV current transformer compatible with self powered relay (single core for protection only). ix) relay shall be communicable on IEC 60870-5-103 protocol or modbus protocol so that it shall be able to send information to automation system) relay shall have switch on to fault protection (SOTF) which shall enable immediate tripping while trying to switch on Circuit breaker or SF 6 CB on fault conditions
(iii) Relay shall have records of last 10 faults which shall be possible to view on front faciaxii) Each Circuit breaker or SF 6 CB shall be provided with voltage detection system to check whether cable is live or dead. it shall gave Mechanical indicators for position ON-OFF-EARTH, mimic diagram at front facia of RMU, padlocking facility, cable termination from front of RMU with interlocks of cable door, provision for connecting maximum 1RX3CX300sqmm HT Aluminum power cable accessories alongwith necessary wire as per site required1.5sqmm 3 core for auxelaries supplywith each RMU includes cable boots-1set per feeder, there shall be fault passage indicator with binary contact to send information to field remote terminal unit. sensors for this shall be connected to FPI unit through a fibre optic cable.
-
-
-
... More
Supply and fixing of cable route indicator for HT, 6mm thick CI plate of size 100 mm dia painted with brown colour welded to MS angle iron 50mm x 50mm x 6mm embedded in PCC 1:3:6 type C-1 block size 150mm x 150mm x 160mm complete all as specified and directed.
45
-
-
... More
M&L for horizontal boring by using the trenchless technology under the road at least 60 Cm below road top, in any type of soil for insertion of GI pipe of 80mm bore. complete all as specified and directed.
10
-
-
... More
Supply and fixing of PVC insulated sheathed copper conductor cable of size 1.5sqmm, 3 core, 1100v garde confirming to IS 694/2010, multistranded passing through existing pile, fixed on pole wall from junction box to street light fitting with IP 65/66 protection complete all as specified and directed.
200
-
-
... More
ARBORICULTURE
Digging pit of sizes 0.60 m x 0.60 m and 0.60 m deep in any type of soil for plantation of sapling of trees and removal of rubbish and surplus earth not exc 50m and uprooting of all vegetation around 2.0m radius of planted sapling etc. and Refilling the same pit with excavated sweet earth mixed with Bio farmyard manure (compost) in the ratio of 4:1 by volume (for mix 4 parts of excavated top half portion screened earth free from stone,rubbish and etc and 1 Part of compost manure ). Refilled earth shall be Flooded with water for 5 to 6 days for settlement of filled earth to prevent void formation incl refilling settled portion of pit with mix of earth and compost to level and plantation of selected sapling of fruit bearing tree and adding 5ml of Chlorpyriphos 20 EC mixed in about 2 Kg soil in each earth Pit including supply and planting tree plants of species of height minimum 4 feet high from ground leve as Neem (Azadiracha indica) complete all as specified and directed.
Note:- (i) Bottom halves excavated earth is not used to refill pit. It shall be removed.
(ii) Cost of Bio farmyard manure ( compost) included in item
5
-
-
... More
Ditto all as per item No 16.00 above but Gulmohar (Delonix regia)
5
-
-
... More
Ditto all as per item No 16.00 above but Peepal tree (Ficus religiosa)
5
-
-
... More
Ditto all as per item No 16.00 above but Banyan (Ficus benghalensis)
5
-
-
... More
Ditto all as per item No 16.00 above but Pink Cassia (Cassia javanica)
5
-
-
... More
Ditto all as per item No 16.00 above but Christmas tree (Araucaria heterophylla),
4
-
-
... More
Ditto all as per item No 16.00 above but Golden Cane Palm (Dypsis lutescens),
4
-
-
... More
Ditto all as per item No 16.00 above but Royal Palm (Roystonea regia)
4
-
-
... More
Ditto all as per item No 16.00 above but Foxtail Palm (Wodyetia bifurcata)
4
-
-
... More
Ditto all as per item No 16.00 above but False Ashoka (Monoon longifolium)
9
-
-
... More
Maintenance of planted trees and lawn area grass for two year after certified date of completion issued by GE, by employing one experienced mali per day. The maintenance shall includes the following. (a) Periodical de-weeding of unwanted vegetation growth around the plants/lawn area (b) Watering all the trees/plants/grass and soil with required for proper growth. (c) Periodical prunning the shrubs. (d) periodical lawn mowing. (e) Treating the trees/plants grass and soil with required quantity of approved manure, pesticides and fertillizer including necessary toping of red earth.
(f) Replacement of dried/dead plants/grass/trees. (g) Hose pipe to be arranged by the contractor. (h) water shall be supplied by Deptt free of cost only for watering to plants.
24
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements