Indian Oil Corporation Limited Tender
... More
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 15,05,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_PLHO_171592_1Bid Award Id
ViewTender No
PLCC/Rim Seal Mundra/M/23081Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Bidders_help_Document_for_Preferencial_ Bidding_20230207_v1
Special_Instructions_to_the_Bidders_20230207_version_1a
BOQ Items
... More
RATE OF GST APPLICABLE FOR ALL ITEMS OF THE BOQ CONSIDERING JOB AS COMPOSITE SERVICES. BIDDER TO SELECT ONE GST RATE FROM THE DROP DOWN LIST
-
-
-
... More
HRIM SEAL FIRE PROTECTION SYSTEM FOR 79 M DIA., 13.5 M HEIGHT AND 60000 KL CAPACITY, EXISTING DDFR CRUDE OIL TANKS AT MUNDRA:/ --------------------------------- Dismantling of the existing rim seal fire detection system including ADW units, JBs,cablings, trays, panels, HMIs , water filling arrangement etc in totality and defective modules,piping & nozzles if any as per requirement and submitting to owner in good condition at specified location. --------------------------------- Installation of Rim Seal Fire Protection System on operating crude oil tank shall be done using non-sparking tools and with all safety measures. No hot work shall be allowed during installation of rim seal fire protection system in the existing tanks. Minor modification on tank roof/ rim seal area if necessary for installation of the rim seal fire protection system shall be under the scope of the vendor. --------------------------------- Design, furnishing of drawings with complete bill of material for the scheme, supply of all materials including specified spares at site for AFFF (foam) based Linear Hollow Metallic Tube type Detection/ Two wired Linear Heat Detection cum Extinguishing system complete for crude oil storage tanks (double deck floating roof tanks of diameter 79.0 meters and height 13.5 meters) at Mundra consisting of storage vessels capacity minimum suitable for sufficient quantity AFFF solutions , stainless steel vessels having level detection device for AFFF fitted with structural stand, inert gas actuator, fire/ heat sensing tubes made of SS316, safety valve, sun shade etc. control arrangements/ system piping, fittings, support structures, associated cabling, Design, Supply, Installation and Commissioning of main fire alarm control panel, graphic display panel, client PC, operating system, HMI software & diagnostic software, providing potential free contacts for alarms and status for individual tanks to Owners PLC system, providing serial interface to Owner's PLC system, and supply & installation of instrumentation items such as pressure switch, pressure gauge etc. Control panel/ junction box having multiple output facility to furnish healthy and fire status of individual tanks to suitable location outside tank dyke by providing suitable signal cabling, and all other associated items required for the scheme. Complete erection, installation, testing (by simulation and actuation of the system for each tank, temporary power supply to be provided by the contractor), commissioning, trial run including replenishment of AFFF during testing and carrying out all works as per the tender and as per the specifications/ approved scheme/ drawing etc.. carrying out painting of all vessels/ structural with zinc phosphate primer to 50 micron followed by two coats of high build epoxy finish paint of 65 microns each to brand and shade as specified by Engineer-in-charge, including providing all inputs including laptop and necessary software for configuration of detection device and downloading of status, labour, tools and tackles etc. and handing over the system in satisfactory operating condition.
12
-
-
... More
RSFPS Installation in Existing Tank
-
-
-
... More
AMC for 1st year after defect liability period
12
-
-
... More
AMC for 3rd year after defect liability
9
-
-
... More
AMC for 3rd year after defect liability period
12
-
-
... More
RSFPS Installation in New Tank
-
-
-
... More
HRIM SEAL FIRE PROTECTION SYSTEM FOR 79 DIA., 13.5 M HEIGHT AND 60000 KL CAPACITY, NEW DDFR CRUDE OIL TANKS AT MUNDRA:/ H--------------------------/ Design, furnishing of drawings with complete bill of material for the scheme, supply of all materials including specified spares at site for AFFF (foam) based Linear Hollow Metallic Tube type Detection / Two wired Linear Heat Detection cum Extinguishing system complete for crude oil storage tanks (double deck floating roof tanks of diameter 79.0 meters and height 13.5 meters) at Mundra consisting of storage vessels capacity minimum suitable for sufficient quantity AFFF solutions , stainless steel vessels having level detection device for AFFF fitted with structural stand, inert gas actuator, fire/ heat sensing tubes made of SS316, safety valve, sun shade etc. control arrangements/ system piping, fittings, support structures, associated cabling, Design, Supply, Installation and Commissioning of main fire alarm control panel, graphic display panel, client PC, operating system, HMI software & diagnostic software, providing potential free contacts for alarms and status for individual tanks to Owners PLC system, providing serial interface to Owner's PLC system, and supply & installation of instrumentation items such as pressure switch, pressure gauge etc. Control panel/ junction box having multiple output facility to furnish healthy and fire status of individual tanks to suitable location outside tank dyke by providing suitable signal cabling, and all other associated items required for the scheme. Complete erection, installation, testing (by simulation and actuation of the system for each tank, temporary power supply to be provided by the contractor), commissioning, trial run including replenishment of AFFF during testing and carrying out all works as per the tender and as per the specifications/ approved scheme/ drawing etc.. carrying out painting of all vessels/ structural with zinc phosphate primer to 50 micron followed by two coats of high build epoxy finish paint of 65 microns each to brand and shade as specified by Engineer-in-charge, including providing all inputs including laptop and necessary software for configuration of detection device and downloading of status, labour, tools and tackles etc. and handing over the system in satisfactory operating condition.
9
-
-
... More
AMC for 2nd year after defect liability period
12
-
-
... More
AMC for 2nd year after defect liability
9
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements