Indian Oil Corporation Limited Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Indian Oil Corporation Limited - IOCL Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date22 Oct 2024
Closing Date20 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 18,970Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WRVAD_181380_1Bid Award Id
ViewTender No
PWVDT24042Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Bidders_help_Document_for_Preferencial_ Bidding_20230207_v1
Special_Instructions_to_the_Bidders_20230207_version_1a
BOQ Items
... More
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:Power cables LT : OD upto 20 mm
5200
36
-
... More
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:Power cables LT : OD above 20 mm and upto 40 mm
6230
51
-
... More
Cable Laying - Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and installation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all labour, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:Power cables LT : OD above 60 mm
200
74
-
... More
Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 75 mm, 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.
1200
193
-
... More
STEEL STRUCTURAL WORKS: Supply, fabrication, erection, installation of steel structural works of any type and shape such as cable raks, cable trays, push button control posts etc., as required job complete in all respects including the cost of all labour, tools, material etc., complete.and as per specifications and directions of site engineer/ Engineer-in-Charge.
3000
141
-
... More
Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I.S.458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, jointing of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete in all respects as per specifications, drawing and the direction of the EIC/Site Engineer:200mm
50
1474
-
... More
DISMANTLING OF POWER DISTRIBUTION EQUIPMENTS Dismantling of following power distribution equipments without any damage to it and returning it to our stores or reinstallation of same at a place within a lead of 3 KM (reinstallation charges not includes) all complete with labour and materials as per the direction of the EIC. Equipment weighing above 500 kg and requiring hydra and tractor trolley etc.
5
5976
-
... More
Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: 3 x 10 sqmm
82
668
-
... More
Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: 3 x 25 sqmm
2
740
-
... More
Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: 3 x 35 sqmm
8
793
-
... More
Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: 3 x 50 sqmm
20
1016
-
... More
Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: 3.5 x 35 sqmm
2
1098
-
... More
Providing end termination of power/control cable including cutting, stripping, providing & fixing lugs, cable insulation, providing & glanding double compression heavy duty FLAME PROOF TYPE brass cable gland conforming to IS-12943 (Dowell's or approved equivalent), wherever specified, providing aluminium lugs, crimping/soldering, as necessary, restoration of insulation/clamping of cable, tagging with aluminium tag,earthing of armour, connection to the equipment terminals etc. all complete with labour and materials as per standard and direction of the Engineer-in- charge: 3.5 x 400 sqmm
2
2951
-
... More
SUPPLY & FIXING CHEQUERED PLATES Supply, installation and fixing of ms chequered plates of 5mm thickness. job includes cutting to size, supply of hinges / hooks for lifting, tag welding with support wherever required, painting including supply of paint, supply of all material and labor complete in all respect
820
92
-
... More
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40% : AL,3CX10 mm²,A2XFY
4000
80
-
... More
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40% : AL,3CX25 mm²,A2XFY
730
122
-
... More
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40% : AL,3CX35 mm²,A2XFY
1500
141
-
... More
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40% : AL,3CX50 mm²,A2XFY
3600
175
-
... More
Copper LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40% : CU,3CX2.5 mm²,2XWY
1200
94
-
... More
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40% : AL,3.5CX35mm²,A2XFY
400
164
-
... More
Aluminium LT Cables FRLSH . 1.1 KV, XLPE insulated, extruded PVC type ST-2 inner sheathed, galvanized armoured, PVC type ST-2 overall sheathed, Stranded, FRLSH, C2, Smoke density40% : AL,3.5CX400 mm²,A2XFY
200
1260
-
... More
CABLE DISMANTLING / PULL OUT Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge.Overall diameter 75 MM
100
54
-
... More
CABLE DISMANTLING / PULL OUT Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge.Overall diameter upto 35 MM
100
29
-
... More
CABLE DISMANTLING / PULL OUT Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge.Overall diameter 35 MM but upto 55 MM
100
37
-
... More
CABLE DISMANTLING / PULL OUT Dismantling/pulling out the LT/HT, PVC/XLPE, power / control / telephone / computer, armoured/ unarmoured cables of various voltage grades/types/ sizes / makes from the trench (upto 1.5 metres deep) / pipes / structures / racks or trays, rolling it into empty cable drums, returning the filled up cable drums to the store/another site including transportation of empty cable drums from stores to site and filled up cable drums from site to stores/another site, etc. including cutting of cables at joints/ termination, dismantling of clamps etc. all complete with labour and materials as per directions of the Engineer-in- Charge.Overall diameter 55 MM but upto 75 MM
100
46
-
... More
FLP/WP PUSH BUTTON STATION - Supply ,erection,testing and commissioning of FLP/WP push button(ON/OFF) control station of approved make with /without ammeter for the motor off control at field including connection and termination of copper control cable, fabricating, earthing the supporting structure, painting the same, including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries including the cost of all labour,tools, materials etc. complete in every respect as per the specification and directions of the Site Engineer/Engineer-in-charge including the cost of all labour,tools, materials etc. complete in every respect as per the specification and directions of the Site Engineer/Engineer-in-charge: Without Ammeter
30
7516
-
... More
CONTROL CABLE : SIZE: 61C X1.5 SQMM
700
784
-
... More
FLP/ WP Junction Box, Type C. (Nos. of terminals: 60 Nos.; Bottom entry: 1 No. - 1 1/4" & 1 No.- 1"; Left side entry: 1 No. - 1" & 3 Nos.- 1/2"; Right side entry: 2 No. - 1" & 2 Nos.- 1/2") along with FLP cable glands & FLP plugs for all the cable entries of the Junction as per technical specifications.
2
6192
-
... More
CONTROL CABLE : SIZE: 4C X1.5 SQMM
1000
86
-
... More
CIVIL WORK
-
-
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed by the Engineer-in-Charge : In all kinds of soil
3.72
208
-
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed by the Engineer-in-Charge : In Ordinary rock
19.38
404
-
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.
4
252
-
... More
Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractor's own borrow areas including royalty, with all leads and lifts in low laying areas and filling to required grade and level including watering, compacting at optimum moisture content to 90% of Proctor's density, consolidation and rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thickness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
83.38
474
-
... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)
6.4
7039
-
... More
Centering and shuttering including strutting, propping etc. and removal of formwork for : Foundations, footings, bases for columns
10
327
-
... More
Centering and shuttering including strutting, propping etc. and removal of formwork for : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
4
700
-
... More
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
6
481
-
... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 Kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
6
126
-
... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level : Thermo-Mechanically Treated bars of grade Fe-500D or more
4440.12
95
-
... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.] : All works upto plinth level
5.02
9188
-
... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.] : All works above plinth level upto floor V level
23.27
10801
-
... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.] : Add for using extra cement in the items of design mix over and above the specified cement content therein. [Note: Unit "QN" shall mean "QUINTAL"]
15.55
773
-
... More
Brick work with common burnt clay F.P.S./FLY ASH (non modular) bricks of class designation 7.5 in foundation and plinth in : Cement mortar 1:4 (1 cement : 4 coarse sand)
20.15
7326
-
... More
Brick work with common burnt clay F.P.S./FLY ASH (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
61.6
8972
-
... More
Finishing : 12 mm cement plaster of mix : 1:6 (1 cement : 6 fine sand)
431.2
292
-
... More
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
184.8
189
-
... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
246.4
132
-
... More
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour : Two coats
246.4
130
-
... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content : With water thinnable cement primer on wall surface having VOC content less than 50 grams/ litre.
246.4
68
-
... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top cover of required thickness for rolling shutters : 80 x 1.25 mm M.S. laths with 1.25 mm thick top cover
6.25
3382
-
... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top cover of required thickness for rolling shutters : Providing and fixing ball bearing for rolling shutters.
2
482
-
... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes
9.5
1372
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : For fixed portion : Powder coated aluminium (Minimum thickness of powder coating 50 micron)
10
524
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : Powder coated aluminium (Minimum thickness of powder coating 50 micron)
110
627
-
... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket etc. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] : With float glass panes of 5.50 mm thickness
9.5
1489
-
... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. : With stainless steel cover plate minimum 1.25 mm thickness
2
2771
-
... More
Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 laid to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
64
715
-
... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
6.4
2244
-
... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.
21.6
705
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
7.2
327
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Lintels, beams, plinth beams, girders, bressumers and cantilevers
81.6
634
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Columns, Pillars, Piers, Abutments, Posts and Struts
51.2
843
-
... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Suspended floors, roofs, landings, balconies and access platform (with water proof ply 12 mm thick)
68.25
895
-
... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joints with white cement and matching pigments etc., complete :Size of Tile 600x600 mm
64
1724
-
... More
Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS:13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.
28
350
-
... More
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion :Bend- 87.5 Degrees (110 mm)
8
149
-
... More
Providing and fixing Unplasticised PVC (uPVC) pipe clips (110 mm) of approved design to unplasticised-PVC rainwater pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
12
331
-
... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing : 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]
3.2
9829
-
... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. [Note: Unit "KG" shall mean "PER KG PER 50 KG OF CEMENT"].
26.4
64
-
... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. :Using Grade 'A' sealing compound. [Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH"].
8
3
-
... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] :Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
7.68
1996
-
... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge]
1.36
2912
-
... More
Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]
1.02
1688
-
... More
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of steel shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge.]
4000
3
-
... More
Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of : G.S. Sheet
64
140
-
... More
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : Of area 3.0 sq. metres and below
1
122
-
... More
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and directions of the Engineer-in-Charge complete in all respect :Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make.
0.96
446
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements