Indian Oil Corporation Limited Tender
Search for the latest Gujarat tenders online related to civil works, road & transport, pipelines and more easily here on BidAssist. Here you can get any and every tender that is posted on the eProcurement Gujarat website, minus the clutter. No need for a tender ID, as on BidAssist, you can view any Gujarat tender by merely typing Gujarat in the search box.
Costs
EMD
₹ 7,600Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WRRAJ_180782_1Bid Award Id
ViewTender No
PWRJT24209Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Special_Instructions_to_the_Bidders_20230207_version_1a
BOQ Items
... More
SERVICES AS & WHEN REQUIRED
-
-
-
... More
MINOR BREAKDOWN Maintenance visit for maintenance of TRANSFORMER & NGR,CURCUIT BREAKER (VCB & SF6),CURRENT TRANSFORMER, POTENTIAL TR ANSFORMER, ISOLATOR SWITCH, EARTH SWITCH, LIGHTINING ARRESTOR,RTCC PANEL,BATTERY & CHARGER,PROTECTION SYSTEM as when requiredand as per instruction of EIC and site engineer
3
-
-
... More
Cleaning of cable trenches of depth upto 3 meter and width 1.5 meter of cable galleries, sub stations and other locations etc. The j ob includes lifting of RCC slabs/ Chequerred plates, removing of paper waste jute, mud, or any other unwanted materials lying in tre nches & dumping these waste materials in the nearest dust bin or as directed by the Engineer-in-Charge., keeping back RCC slabs/cheq uerred plates in positions. All complete with men and materials as per direction of the Engineer-in Charge.
1000
-
-
... More
Cleaning of HT Bus panel (Each breaker panel). It includes opening of top cover, removal of dust by vaccum cleaning/blower etc. Chec king & tightening of connections, cleaning of insulator, application of petroleum jelly and boxing up of the Bus bars/panels. All cl eaning materials such as cotton waste, Markin cloth etc. shall be supplied by the contractor. All complete with men, materials and e quipments like tools & tackles as per direction and satisfaction of the Engineer-in-Charge.
300
-
-
... More
Cleaning of transformer includes surface cleaning i.e. cleaning of accumulated sticky oil and other dust, oil fins. Job includes ope ning of LT duct & HT terminal box, cleaning of duct and terminal box, tightening of nuts & bolts wherever is required. Job to be com pleted with all men, materials and equipments like tools & tackles as per direction and satisfaction of the Engineer-in-Charge. All cleaning materials such as markin cloth, cotton waste etc. shall be supplied by the Contractor.
6
-
-
... More
Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, wire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application of enamel paint by spray painting on bus duc ts, transformers/motors/ or any other metallic surface with one coat of ready mixed primer and two coats of Approved quality/APCOLIT E ASIAN synthetic enamel paint including supply of paint suitable for a temperature of 100 Degree Celsius. All complete with labour and materials as per directions of the Engineer-in- Charge.
50
-
-
... More
PAINTING OF ELECTRICAL EQUIPMENTS: Cleaning of surface, rust removing of foreign matter, rubbing down thoroughly with emery paper, w ire brush, washing with degreasing solvent (white spirit) to remove grease etc. and preparation of surface for application of paint by spray painting on electrical equipment/ structures/ poles or any other metallic surface with two coats of approved brand and manu facturer Aluminium paint including supply of paint suitable for a temperature of 100 Degree Celsius. All complete with labour and ma terials as per directions of the EIC
100
-
-
... More
Lettering with black Japan paint of approved brand and manufacture including supply of all material & labour and transportation etc Note : Unit of measurement is considered EACH which is equal to per cm height per letter.
5000
-
-
... More
Re-lettering with black Japan paint of approved brand and manufacture. Note : Unit of measurement is considered EACH which is equal to per cm height per letter.
5000
-
-
... More
SUPPLY & INSTALLATION AS & WHEN REQUIRED
-
-
-
... More
LIGHTNING ARRESTOR : Supply of lightning arrestors with insulating base fittings etc. as per specifications: For 60 kV rated voltage (Highest system voltage 72.5 KV) , 10 KA lightening arrestors
3
-
-
... More
ISOLATOR : Supply of 3 poles, centre post rotating type, offload motarized isolator cum earthing switch with accessories and fitting s for outdoor installation as required as per specification: 66kV, 630 A, 31.5 KA for 1 sec, rated short time current
1
-
-
... More
Supply of all necessary tarrif metering and equipments to be mounted at receiving end of supply in the switchyard and should consist of following:- 1 phase Outdoor type CTs of ratio and rating as per respective State Electricity board guidelines.
3
-
-
... More
Supply of all necessary tarrif metering and equipments to be mounted at receiving end of supply in the switchyard and should consist of following:- 3 phase Outdoor type PTs of ratings & ratio as per respective State Electricity board guidelines.
1
-
-
... More
Supply of all necessary tarrif metering and equipments to be mounted at receiving end of supply in the switchyard and should consist of following:- 1 phase Outdoor type PTs of ratings & ratio as per respective State Electricity board guidelines.
3
-
-
... More
LIGHTNING ARRESTOR : Erection, installation, testing & commissioning of lightning arrestors with insulating base, discharge counter, fittings etc. including assembling as required, installation on already made steel structures or fixtures, aligning, levelling, gro uting, assembling and fitting of accessories/ instruments etc. supplied separately, if any, making of the conductor connection, cabl es connections as required, earthing, testing, commissioning the same, complete in all respects including consumables, tools/ equipm ents and labour as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer. The supply of earthing strip is not covered in this item.For 60 kV rated voltage(Highest system voltage 72.5 KV) , 10 KA lightening arrestors
3
-
-
... More
ISOLATOR : Erection, installation, testing & commissioning of centre post rotating type, offload isolator cum earthing switch with a ccessories and fittings as required, including installation on already made steel structures or fixtures, aligning, assembling and f itting all accessories/ instruments etc. supplied separately, if any making connections of outgoing/ incoming conductor, cable conne ction as required, earthing, testing, commissioning the same, complete in all respects including consumables, tools/equipments and l abour as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer. The supply of cables and earthing strip a re not covered in this item.66kV, 630 A, 31.5 KA for 1 sec, rated short time current
1
-
-
... More
Erection, installation, testing and commissioning of tariff metering and equipments including connection of cables as per respective State Electricity Board guidelines. Outdoor CTs (single phase)
3
-
-
... More
Erection, installation, testing and commissioning of tariff metering and equipments including connection of cables as per respective State Electricity Board guidelines. Outdoor PT(3 phase)
1
-
-
... More
Erection, installation, testing and commissioning of tariff metering and equipments including connection of cables as per respective State Electricity Board guidelines. Outdoor PT(single phase)
3
-
-
... More
Supply, erection and installation of strain insulators, post insulators, ACSR DOG conductor, connectors, shield wire, etc for outdoo r switchyard. The job also includes assembling as required, installation on already made concrete foundations or fixing to walls or steel structures or fixtures, aligning, levelling, groutting assembling and fittings all accessories etc. supplied separately, compl ete in all respects including consumables tools/ equipments and labour as per specifications, drawings and directions of Engieer-in- charge/ Site Engineer.: Strain insulators for 66 KV
3
-
-
... More
Supply, erection and installation of strain insulators, post insulators, ACSR DOG conductor, connectors, shield wire, etc for outdoo r switchyard. The job also includes assembling as required, installation on already made concrete foundations or fixing to walls or steel structures or fixtures, aligning, levelling, groutting assembling and fittings all accessories etc. supplied separately, compl ete in all respects including consumables tools/ equipments and labour as per specifications, drawings and directions of Engieer-in- charge/ Site Engineer.: ACSR 'DOG' conductors for 66KV
100
-
-
... More
Supply, erection and installation of strain insulators, post insulators, ACSR DOG conductor, connectors, shield wire, etc for outdoo r switchyard. The job also includes assembling as required, installation on already made concrete foundations or fixing to walls or steel structures or fixtures, aligning, levelling, groutting assembling and fittings all accessories etc. supplied separately, compl ete in all respects including consumables tools/ equipments and labour as per specifications, drawings and directions of Engieer-in- charge/ Site Engineer.: Connectors for 66 KV
1
-
-
... More
Supply, erection and installation of strain insulators, post insulators, ACSR DOG conductor, connectors, shield wire, etc for outdoo r switchyard. The job also includes assembling as required, installation on already made concrete foundations or fixing to walls or steel structures or fixtures, aligning, levelling, groutting assembling and fittings all accessories etc. supplied separately, compl ete in all respects including consumables tools/ equipments and labour as per specifications, drawings and directions of Engieer-in- charge/ Site Engineer.: Shield wire for 66 KV
100
-
-
... More
Supply, erection and installation of strain insulators, post insulators, ACSR DOG conductor, connectors, shield wire, etc for outdoo r switchyard. The job also includes assembling as required, installation on already made concrete foundations or fixing to walls or steel structures or fixtures, aligning, levelling, groutting assembling and fittings all accessories etc. supplied separately, compl ete in all respects including consumables tools/ equipments and labour as per specifications, drawings and directions of Engieer-in- charge/ Site Engineer.: Post insulators for 66 KV
3
-
-
... More
GALVANISED STEEL STRUCTURE : Supply, fabrication, erection, installation including RCC foundation works of galvanised steel structur al works of any type and shape for outdoor switchyard equipments, gantry and column etc. complete in all respects including consumab les, tools/ equipments and labour as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer.
2
-
-
... More
Supply & replacement of OTI/WTI as per direction of Engineer-in- Charge.
2
-
-
... More
Supply & replacement of Buchholz relay as per direction of Engineer-in-Charge.
1
-
-
... More
Supply, fixing, installation of Breather Unit without silicagel suitable for upto 1500gm silicagel as per direction of Engineer-in-C harge.
3
-
-
... More
Supply & Replacement of silica gel in transformers as per direction of Engineer-in-Charge.
50
-
-
... More
HT TERMINATION KIT : Supply of indoor / outdoor HT cable termination kit complete in all respect for the following sizes of cables a s per specifications: 3CX400 SQMM, 66KV(UE), OUTDOOR TYPE
1
-
-
... More
HT TERMINATION KIT : Supply of indoor / outdoor HT cable termination kit complete in all respect for the following sizes of cables a s per specifications 3CX400 SQMM, 6.6KV(UE), OUTDOOR TYPE
1
-
-
... More
Supply of hand Gloves: suitable for 66 KV voltage level
3
-
-
... More
MAJOR BREAKDOWN Maintenance visit maintenance of TRANSFORMER & NGR,CURCUIT BREAKER (VCB & SF6),CURRENT TRANSFORMER, POTENTIAL TRANS FORMER, ISOLATOR SWITCH, EARTH SWITCH, LIGHTINING ARRESTOR,RTCC PANEL,BATTERY & CHARGER,PROTECTION SYSTEM as when required and as p er instruction of EIC and site engineer
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements