Military Engineer Services Tender

Download documents of Goa MES Tender

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Eprocure
Opening Date11 Feb 2025
Closing Date24 Mar 2025
Tender Amount₹ 36,09,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.

-

-

-

... More
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 12 V Battery (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop

-

-

-

... More
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-Battery required as per OEM/manufacture, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Battery charger as per OEM/Manufacturer recommended (aa) Fuel tank: as per OEM/manufacture, with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.

-

-

-

... More
(c) Alternator: Suitable rated 200 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1) Make : Stampford/Crompton/Kirloskar/Greaves Power

-

-

-

... More
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 200 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size as per OEM/ amnufacturer and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-

-

-

-

... More
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt LED fitting.

-

-

-

... More
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:

-

-

-

... More
(f) AMF control circuit with 4 pole MCCB 320 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.

-

-

-

... More
(g)Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate.

-

-

-

... More
(h) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-1) DG set design should be as per CPCB -IV Norms 2)The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department.

-

-

-

... More
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out in soft disintegrated rock complete all as specified and as directed.

70

-

-

... More
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25 cm deep as in soft disintegrated rock complete all as specified and as directed.

45

-

-

... More
Removal of excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point in rock complete all as specified and as directed.

25

-

-

... More
Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.

10

-

-

... More
M&L Sand filling in trenches for cable protection with screened rever washed sand,8 CM below the cable and 15CM above the cable and punning down the same to 18 CM all as specified and directed. (Note:- punning down thickness of sand will be measured & paid Only)

20

-

-

... More
Supply and laying un re-inforced precast concrete cable cover ISI Marked factory duly embosed "LOW VOLTAGE" ISI marked,class LV, type-I, flat of size 250x150xx40 mm in trenches over and across the cable complete all as specified.

1500

-

-

... More
Supply and fixing tubes, 100mm bore, light grade, galvanised, grouted in ground using PCC 1:3:6 for fixing of post top lentren, complete all as specified and as directed.(Note:- rate quoted shall be deemed to include PCC 1:3:6 type C-1) complete all as specified and as directed.

12

-

-

... More
S& F XLPE insulated armoured and PVC sheathed heavy duty electric cable with aluminium conductor 1100 volt grade laid in trenches passing through pipes /ducts including testing complete of following cross sectional area of size 3.5 X 240 sqmm all as specified and dirtected by Engr-in-charge Note- Rate is inclusive of cable gland & cable lugs

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.