Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 55,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693061_1Tender No
85906/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm complete all as specified and directed.
1200
-
-
... More
Supply and lay PCC cable cover class HV, type 1, flat size 300mm x 180mm x 40mm with ISI mark complete all as specified and directed.
720
-
-
... More
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil complete all as specified and directed.
170
-
-
... More
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed complete all as specified and directed.
28
-
-
... More
Supply and laying HT XLPE cable insulated , screened, PVC bedded , galvanised steel strip armoured, electric power cable (Heavy duty) with aluminium conductor, cross sectional area 95 Sqmm 3 core 11KV grade, including dismantling of existing cable complete all as specified and directed.
130
-
-
... More
Supply and laying LT UG cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandarded including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall including dismantling of existing cable of following sizes, complete all as specified and directed.
-
-
-
... More
(a) 50 Sqmm 3.5 Core
160
-
-
... More
(b) 70 Sqmm 3.5 Core
200
-
-
... More
(c) 95 Sqmm 3.5 Core
400
-
-
... More
(d) 120 Sqmm 3.5 Core
320
-
-
... More
(e) 185 Sqmm 3.5 Core
150
-
-
... More
M&L for fixing GI tubing light grade use for the protection of cable all as specified and directed by Engr-in-Charge.
-
-
-
... More
(a) 50 mm dia
18
-
-
... More
(b) 80 mm dia
12
-
-
... More
M&L for High density polyethylene pipes (HDPE) of pressure rating PN 6 (SDR 21) laid in trenches for cable protection complete all as spcified and directed of following sizes:-
-
-
-
... More
(a) 50 mm dia
600
-
-
... More
(b) 90 mm dia
140
-
-
... More
M & L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including dismantling old burnt cable joint termination complete all as specified and directed.
1
-
-
... More
M & L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including dismantling old burnt cable joint termination complete all as specified and directed.
1
-
-
... More
M & L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm including dismantling old burnt cable joint termination complete all as specified and directed.
1
-
-
... More
M&L for straight through joints (Epoxy) for UG cable including joint kits and labour complete for making joints suitable for 35 to 95 sqmm, 3.5 core, 1100 V grade cable complete all as specified and directed.
2
-
-
... More
All as per Item No.15 but for 120 to 150 sqmm 3.5 core, 1100 V grade cable complete all as specified and directed.
2
-
-
... More
Supply & fixing MCCB 400 Amps, 36kA, 4 pole, 415 Volts, 50 Hz including dismantling old one complete all as specified and directed.
1
-
-
... More
Supply & fixing MCCB 250 Amps, 25kA, 4 pole, 415 Volts, 50 Hz including dismantling old one complete all as specified and directed.
2
-
-
... More
Supply & fixing MCCB 160 Amps, 16kA, 4 pole, 415 Volts, 50 Hz including dismantling old one.
2
-
-
... More
Supply & fixing MCCB 100 Amps, 16kA, 3 pole, 415 Volts, 50 Hz including dismantling old one.
1
-
-
... More
Material and labour for preparation of old painted surface of feeder pillar box/LT panel by removing all dust etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including of identification etc all as directed by Engineer-in- charge.
10
-
-
... More
Disconnecting HT/LT cable and earthing connections of burnt/defective transformer of capacity 500 to 800 KVA , 11 KV/433 volts 3 phase from pole/floor mounted, taking from site of installation carefully with the help of Crane and transportation of the same to workshop for repairs, draining out the transformer oil, dismantling complete and taking out the core assembly and removing burnt out windings, dehydrating the core assembly, reassembling transformer after repair, replacement of complete gasket set, refilling the oil duly filtered / dehydrated, topping up with new oil, carrying out routine tests, welding work, leakage repairing and complete servicing including transportation back to site, testing and commissioning of the repaired transformer at site on full load after making cable and earthing connections complete all as specified and as directed.
Note :- New transformer oil, Dehydration of transformer oil, LT/HT bushings/studs shall be measured and paid separately.
1
-
-
... More
All as per item No. 22.00 here in before but 400 KVA all as specified and as directed.
1
-
-
... More
All as per item No. 22.00 here in before but 125 to 200 KVA all as specified and as directed.
1
-
-
... More
M&L for rewinding in repair of HT winding with Copper strip of suitable size/gauge, fixing the coil in position in core assembly and making connection as per original pattern including providing insulation, varnish, all as specified and as directed
-
-
-
... More
(a) Transformer 500 - 800 KVA capacity
1
-
-
... More
(b) Transformer 400 KVA capacity
1
-
-
... More
(c) Transformer 125 - 200 KVA capacity
1
-
-
... More
All as per item No. 25 here in before but LT limbs of following capacities :-
-
-
-
... More
(a) Transformer 500 - 800 KVA capacity
1
-
-
... More
(b) Transformer 400 KVA capacity
1
-
-
... More
(c) Transformer 125 - 200 KVA capacity Notes for item No 25 & 26 :
i) Guarantee of one year will be provided by the contractor for rewinded limb.
1
-
-
... More
S&F in repairs brass metal studs nut & washers suitable for 11 KV HT side of transformer upto 800 KVA all as specified and as directed
3
-
-
... More
S&F in repairs brass metal studs nut & washers suitable for 11 KV LT side of transformer upto 800 KVA all as specified and as directed
3
-
-
... More
S&F in repairs HT bushing suitable for upto 800 KVA Transformer complete all as specified and as directed
3
-
-
... More
S&F in repairs LT bushing suitable for upto 800 KVA Transformer complete all as specified and as directed
3
-
-
... More
S & F Temperature gauge suitable size for transformer of capacity 800 KVA all as specified and as directed
1
-
-
... More
Supply and fill in repairs existing breather silica gel of superior quality for transformer breather all as specified and as directed
3
-
-
... More
S&F in repairs transparent PVC material breather assembly for transformer upto 800 KVA capacity all as specified and as directed
2
-
-
... More
M & L for transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine to remove impurities from oil such as moisture, dirt, air and other gases and to improve BDV upto 50KV at 2.5mm air gap all as specified and as directed.
Note: Transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine shall be done on existing installation place on same day.
3500
-
-
... More
M&L for new transformer oil for topping up or for replacement in Transformers /Servo Voltage stabilizer complete all as specified and as directed Note: Oil shall be in company sealed barrel having BDV not less than 60 KV
600
-
-
... More
M &L for Dismantling top cover, lifting complete core assembly of transformer taking out old gasket set and drain out existing complete oil servicing of complete transformer, replacing nuts bolts, gasket sets complete as required and reassemble the transformer including testing and installation at site for upto 800 KVA transformer. (Note :- Oil, and HT/LT bushing shall be measured and paid separetly)
1
-
-
... More
M & L for preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc of transformers upto 800 KVA all as directed by Engineer-in-Charge.
10
-
-
... More
Shifting of transformer from one site to another in case of emergency by disconnecting HT/LT cable and earthing connections of transformer of capacity 200 to 500 KVA , 11 KV/433 volts 3 phase floor mounted incl making all electrical connections at the place of installation complete all as specified and as directed.
Notes :- (i) The rate for transport and lifting of transformer by crane is deemed to be included in the rate quoted.
(ii) The rate is deemed to be inclusive for disconnection & making connnections of transformer as required.
1
-
-
... More
Supply and installation of LT panel cubical, weather, dust and vermin proof (out door type) double door Front and back openable CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper busbar size 50 x 6 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :-
(i) MCCB 400 Amps, 4 Pole, 36 kA, Adjustable thermal and fixed magnetic setting - 01 No (Incoming).
(ii) MCCB 250 Amps, 4 pole, 25 kA, Adjustable thermal and fixed magnetic setting - 01 No (Outgoing).
(iii) MCCB 160 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing).
1
-
-
... More
(iv) MCCB 100 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing).
(v) MCCB 63 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing).
(vi) Onload Changover switch 400 Amps - 01 No
(vii) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO)
(viii) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set.
(ix) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot
-
-
-
... More
Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) double door Front and back openable CRPI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper busbar size 25x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :-
t
1
-
-
... More
(i) MCCB 160 Amps, 4 Pole, 25 kA, Adjustable thermal and fixed magnetic setting - 01 No (Incoming).
(ii) MCCB 100 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing).
(iii) MCCB 63 Amps, 4 pole, 16 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing).
(iii) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO)
(vii) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set.
(viii) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot.
-
-
-
... More
M/L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia eith funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr-in-Charge.
8
-
-
... More
M&L for servicing of 11 KV Indoor Vaccum Circuit Breaker (VCB) of any make at NOFRA sub station which includes disconnecting, removing old grease, re-greasing of moving parts with recommended grease and checking of the entire breaker trolley mechanism,checking of the closing and tripping time in milli seconds using high precision time scope timer, measurements of contact resistance and insulation values, cleaning the complete VCB by opening front and back doors, tightening of cable connections, checking & repairing the current circuit panel wiring, relay etc and re-assembling & re-installing the VCB back to ts original position including testing and commissioning after completion of work all as specified and as directed.
NOTE : The cost for minor spares such as operating handles, screws,nuts,bolts, washers indicating lamps, lamp holders, HRC fuses,fuse carriers etc shall be included in the rate quoted for the item. Servicing shall be carried out as per manufacturer recommended checklist.
2
-
-
... More
M&L for cross arm bracing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and incl applying two coats of aluminium paint over one coat of red oxide primer including dismantling of old cross arms and all as directed by Engr-in-charge.
1
-
-
... More
M&L for HT 11 KV Disc type insulator with hardware, single disc assembly, polymeric insulator, socket type, including taking down old unsv complete all as specified and as directed
4
-
-
... More
S&F for Pin type polymer insulator including one galvanised mild steel spindle two GI washers and one GI iron nut for 11 KV grade including dismantling the old U/S insulator complete all as specified and as directed
4
-
-
... More
S&F cable route indicator, made out of precast RCC, embossed with 'HT UG cable 11kV' grouted in and including excavation and PCC (1:2:4) type B-2 (using 20mm graded stone aggregate) for refilling complete all as specified and directed.
14
-
-
... More
S & F lightening arrestor HT 11 KV pole mounting with polymeric insulator complete with all fittings transmission class nominal discharge current upto 65 KA including removing the defective one complete all as specified and directed.
3
-
-
... More
M & L for preparation of old painted surface of electric pole by removing all dirt, dust, etc and painting complete surface including connected accessories with one coat of Apex emulsion paint/aluminium paint of approved colour including cross arms/bracing support on poles and writing of pole Nos etc all as directed by Engineer-in-Charge for following pole:-
-
-
-
... More
(a) HT concrete pole of any length
26
-
-
... More
(b) LT concrete pole of any length
129
-
-
... More
M & L , servicing of 2/4 pole structure ,GOD and DO fuses, jumpers, insulators and applying petroleum jelly on GOD after removing carbon, dust etc complete all as specified and directed by Engr-in charge.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%