Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681883_1Tender No
8530/Goa/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking down old GI tubing & connection of the following sizes complete all as specified and directed. Note :- Excavation & earth work shall be measured and paid separately under relevant items of Schedule
-
-
-
(a) 80 mm bore size
20
-
-
(b) 50 mm bore size
QUANTITY 24+36=60
60
-
-
(c) 40 mm bore size
QUANTITY 42+36=78
78
-
-
(d) 32 mm bore size
QUANTITY 84+30=114
114
-
-
(e) 25 mm bore size
QUANTITY 108+48=156
156
-
-
Supply & laying GI Tube medium grade with all fitting (union, elbow, socket) , flanges,nut & bolts laid in trenches. Complete all as specified and directed of the following size:-
-
-
-
(a) 80 mm bore size
20
-
-
(b) 50 mm bore size
QUANTITY 24+12=36
36
-
-
(c) 40 mm bore size
QUANTITY 30+24=54
54
-
-
(d) 32 mm bore size
QUANTITY 48+18=66
66
-
-
(e) 25 mm bore size
QUANTITY 60+24=84
84
-
-
All as per item No. 5 but fixed to wall/Ceiling or laid on floor with all fitting (union, elbow, socket) , flanges,nut & bolts. Complete all as specified and directed of the following sizes :-
-
-
-
(a) 50 mm bore size
QUANTITY 12+12=24
24
-
-
(b) 40 mm bore size
QUANTITY 12+12=24
24
-
-
(c) 32 mm bore size
QUANTITY 12+36=48
48
-
-
(d) 25 mm bore size
QUANTITY 24+48=72
72
-
-
S&F in repairs gun metal gate valve with iron head wheel screwed both ends for iron pipe, fixed in repairs with ISI mark of the following size. Complete all as specified and directed.
-
-
-
(a) 50mm size
QUANTITY 4+5=9
9
-
-
(b) 40mm size
QUANTITY 5+5=10
10
-
-
(c) 32 mm size
QUANTITY 6+5=11
11
-
-
(d) 25 mm size
QUANTITY 6+8=14
14
-
-
(e) 20 mm size
8
-
-
M/L for cutting existing steel tubing for alteration or addition (Each cut measured) of the sizes and screwing existing steel tubing for alteration of size 40/50mm bore size. Complete all as specified and directed.
QUANTITY 10+5=15
15
-
-
Repair of valve chamber by cleaning and removing small bushes inside and surrounding the valve chamber and necessary brick works, plastering in cement mortar 1:4, painting with antifungal paint of 2 coats inside and out side including dismantling of unserviceable MS sheet cover, S & F new MS sheet cover of 3.15mm thick with 2 coats of synthetic enamel paint over a coat of red oxide to steel surface and locking arrangements, including necessary welding 60 cm x 60 cm x 60 cm (internal dimension). Complete all as specified and directed.
QUANTITY 4+2=6
6
-
-
All as per item No 09 but of size 90x90x90 cm (internal dimension)
QUANTITY 2+2=4
4
-
-
M/L providing cement concrete type B1 (1:2:4) using 20mm graded stone aggregate as in roof kerbs or mud stops, base for valve pit, making good the road cutting and like, rounded or chamfered on edges. Complete all as specified and directed.
QUANTITY 3+2=5
5
-
-
S&F in repair fully automatic star-delta starter in sheet metal enclouser, AC-3 phase, 415 Volts, 50 Hz, with-over load protector, single phase protection relay and electronic timer, including taking out old unserviceable one of motor upto 15 HP capacity. Complete all as specified and directed.
QUANTITY 1+1=2
2
-
-
S&F DOL/ submersible starter in sheet metal enclouser, AC-3 phase, 415 Volts, 50 Hz, including taking out old unserviceable one. Complete all as specified and directed of the following capacity :-
-
-
-
(a) For Motor upto 5 HP, submersible starter, AC, 3 Phase, 415 Volts
QUANTITY 1+1=2
2
-
-
(b) For Motor upto 7.5 HP Submersible Starter, AC, 3 Phase, 415 Volts
1
-
-
Repairs to AC, 3 phase, 415 Volts, 50 Hz Electric monoblock 5 HP pumping motor including rewinding of starter of the motor, transport burnt motor to civil work shop, removing burnt / unserviceable windings completely including insulation material and rewinding stator with super enamelled copper wire of standard specification with standard insulation material complete and fixing back to original position and testing, commissioning etc including replacing defective bushes, bearing by new one. Complete all as specified and directed.
QUANTITY 2+2=4
4
-
-
M & L for removing existing Centrifugal pump set from base frame after disconnecting suction & delivery lines replacing bearings, repairing and grinding the shaft etc complete and reassembling and fixing back to original position and testing, commissioning etc. Complete all as specified and directed for the capacity of 5 HP pump set Notes :- (1) Replacement of major parts will be measured & paid separately; (2) Any minor part if required will be provided by contractor without any extra cost. QUANTITY 2+2=4
4
-
-
Removal of existing submersible pump set of capacity 5 HP to 15 HP from the existing borewell (by using any method) of any depth and transporting to workshop for checking and bringing back after repair, reinstalling of submersible pump set in the borewell including testing and commissioning. Complete all as specified and directed.
Note : (i) The quoted rate shall be deemed to include the cost of any T&P or machinery required for carrying out the work (ii) Replacement/Repair will be measured separately.
QUANTITY 1+2=3
3
-
-
Supply of the following spare parts for submersible pump against above serial item No 16. Complete all as specified and directed.
-
-
-
(a) GM impeller
QUANTITY 1+2=3
3
-
-
(b) GM Neck ring
QUANTITY 1+2=3
3
-
-
(c) Coupling sleeve
QUANTITY 1+2=3
3
-
-
(d) MS Stud for pump
QUANTITY 1+2=3
3
-
-
(e) Bush for submersible motor
QUANTITY 1+2=3
3
-
-
(f) Bush for pump
QUANTITY 1+2=3
3
-
-
Repairs to AC, 3 phase, 415 Volts, 2900 RPM Electric Submersible pumping motor upto 5 HP to 15 HP capacity. Dismantling of burnt motor, cutting and taking out burnt stator winding from motor, cleaning the stator and rewinding with super enamelled water proof copper wire of original gauge/size including re-assembling complete all as specified and directed. Note- Removing, lifting and refixing are not included in the unit rate quoted but same are deemed to be included in Ser No 16.
QUANTITY 1+2=3
3
-
-
S & F for submerssible cable ,flat, PVC insulated copper conductor stranded type, 1100 volts grade of size 3 core 6 sq. mm size, including jointing of cable with proper kit, connecting to motor and starter with suitable thimble including dismantling the old one complete all as specified and directed.
QUANTITY 90+101=191
191
-
-
S & F in repairs pressure gauge, 100/150 mm size, fitted on delivery side of pump set , including all necessary items required & dismantling the old one complete all as specified and directed.
2
-
-
S & F in repairs Single phase preventer and connected to existing starter, suitable for centrifugal pump set of capacity 10 to 15 HP of any make. Complete all as specified and directed.
4
-
-
S & F in repairs Motor protection relay over load current load 8-22 Amp and connected to existing starter, suitable for centrifugal pump set of capacity 10 to 15 HP of any make . Complete all as specified and directed.
4
-
-
Servicing and maintaining pumping installation by tightening the gland of pump ,replacing rubber coupling ,bushes and clearing the leakage of sluice valves,Spindle, NRV's, aircock, pressure guage by tightening gland etc. complete at Coast Guard Pump houses comprising 5 Nos pump set of capacity 5 to 15 HP complete all as specified and directed.
QUANTITY 5+4=9
9
-
-
M& L preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete Pump set including accessories with two coats of synthetic enamel paint of approved colour over a coat of red-oxide primer . Complete all as specified and directed. for the following size pump and motor and connected items sluice valve and delivery/suction pipe line, etc complete in Tech Area pump houses, Goa comprising of the following :- a) Pump & motors upto 15 HP capacity b) Sluice valves c) NRVs.
QUANTITY 4+2=6
6
-
-
S & F PVC insulated copper conductor stranded type, FRLS, 1100 volts grade of size 10 sq. mm single core electric cable, including connecting motor to starter with suitable thimble, laid in the PVC conduit including dismantling old one complete all as specified and directed.
QUANTITY 108+120=228
228
-
-
M & L for bacteriological and chemical analysis of water sample at DIRECTORATE OF HEALTH SERVICES, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA complete all as specified and directed. (NOTE : (a) The water sample should be carried in sterilised bottle/watercan which are to be collected from the SCIENTIFIC OFFICER, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA) by the contractor
(b) Testing to be carried out every six months
(c) The following pump houses will be measured separately:- (i) Tech Area Pump House.
QUANTITY 2+6=8
8
-
-
Cleaning of under ground water storage sump of 10000 litres capacity at Technical Area pump house, swimming pool and at 39.37 acres . Complete all as specified and directed having the following process as under:-
(a) Dewatering the tank including all dirt dust and mud.
(b) Desilting and removal of dirty water and sludge with wire brush inside wall and floor surface to remove impurities.
(c) Cleaning of walls,ceiling and bottom of tank by high pressure water jet and bleaching powder.
(d) Removing,shifting mud/impured material to a distance 10m away from sump.
(e) Writing the capacity and date of cleaning with white and black enamelled paint as directed.
QUANTITY 1+1=2
2
-
-
Supply only "Alum Powder" for cleaning and treatment of swimming and divers pool water. Complete all as specified and directed.
600
-
-
Supply only "Soda Ash" for cleaning and treatment of swimming and divers pool water. Complete all as specified and directed.
400
-
-
Supply only (Calcium hypochlorite) Calcium based granular disinfectant dry free flowing and free from lumps for water treatment and swimming pool) packed in 45 kg drum having chlorine content of minimum 65% by mass. Complete all as specified and directed.
QUANTITY 8+11=19
19
-
-
Repair/ Maint of External water supply Non Tech Area at Goa under GE (I)(CG) Goa
Taking down old PPR pipe connection of the following sizes complete all as specified and directed. Note :- Excavation & earth work shall be measured and paid separately under relevant items of Schedule
-
-
-
(a) 63 mm bore size
6
-
-
(b) 50 mm bore size
18
-
-
(c) 40 mm bore size
18
-
-
(d) 32 mm bore size
18
-
-
Supply & laying 3- layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings (union, elbow, socket) , flanges,nut & bolts laid in trenches. Complete all as specified and directed.
-
-
-
(a) 63mm bore size
6
-
-
(b) 50mm bore size
6
-
-
(c) 40mm bore size
6
-
-
(d) 32mm bore size
6
-
-
All as per item No. 32 but fixed to wall/Ceiling or laid on floor with all fitting (union, elbow, socket) , flanges,nut & bolts of the following sizes :-
-
-
-
(a) 50 mm bore size
12
-
-
(b) 40 mm bore size
12
-
-
(c) 32 mm bore size
12
-
-
Taking down old CPVC pipe SDR 11 & Plain CPVC SDR 11 connection of the following sizes complete all as specified and as directed. Note :- Excavation & earth work shall be measured and paid separately under relevant items of Schedule
-
-
-
(a) 50 mm bore size
24
-
-
(b) 40 mm bore size
24
-
-
(c) 32 mm bore size
36
-
-
(d) 25 mm bore size
48
-
-
Supply & laying CPVC pipe SDR 11 & Plain CPVC SDR 11 connection with all fitting (union, elbow, socket) , flanges,nut & bolts laid in trenches . Complete all as specified and directed of the following size:-
-
-
-
(a) 50 mm bore size
12
-
-
(b) 40 mm bore size
12
-
-
(c) 32 mm bore size
24
-
-
(d) 25 mm bore size
24
-
-
All as per item No. 35 but fixed to wall/Ceiling or laid on floor with all fitting (union, elbow, socket) , flanges,nut & bolts.. Complete all as specified and directed of the following sizes :-
-
-
-
(a) 50 mm bore size
12
-
-
(b) 40 mm bore size
12
-
-
(c) 32 mm bore size
12
-
-
(d) 25 mm bore size
24
-
-
S&F in repairs PP-R gate valve (brass insert) as per requirement of the site with ISI mark of the following size complete all as specified and directed:-
-
-
-
(a) 40mm size
2
-
-
(b) 32 mm size
4
-
-
Material & Labour in repair Cast iron detachable joint (CID) suitable for 100 mm dia bore size of pipe . Complete all as specified and directed.
2
-
-
Making connection of PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint etc. complete all as specified and directed.
-
-
-
(a) 16 to 40mm outer dia of pipe
2
-
-
(b) 50 to 75mm outer dia of pipe
2
-
-
Repairs to AC, 3 phase, 415 Volts, 50 Hz Electric monoblock 10 to 12.5 HP pumping motor including rewinding of starter of the motor, transport burnt motor to civil work shop, removing burnt / unserviceable windings completely including insulation material and rewinding stator with super enamelled copper wire of standard specification with standard insulation material complete and fixing back to original position and testing, commissioning etc including replacing defective bushes by new one. Complete all as specified and directed.
2
-
-
Repairs to AC, 3 phase, 415 Volts, 50 Hz Electric monoblock 15 HP pumping motor including rewinding of starter of the motor,transport burnt motor to civil work shop, Removing burnt / unserviceable windings completely including insulation material and rewinding stator with super enamelled copper wire of standard specification with standard insulation material complete and fixing back to original position and testing, commissioning etc including replacing defective bushes, bearing by new one. Complete all as specified and directed.
2
-
-
M & L for removing existing Centrifugal pump set from base frame after disconnecting suction & delivery lines replacing bearings, repairing and grinding the shaft etc complete and reassembling and fixing back to original position and testing, commissioning etc. Complete all as specified and directed for the capacity of 7.5 to 15 HP pump set Notes :- (1) Replacement of major parts will be measured & paid separately; (2) Any minor part if required will be provided by contractor without any extra cost.
2
-
-
Supply only chloroscope for measurement of chlorine level in water showing indication 01.,0.2,0.5,1.0,1.5,2.0 PPM and above including box type indicator showing indication along with 02 Nos test tubes reagent. Complete all as specified and directed.
2
-
-
Cleaning of under ground water storage sump of 20000 gallens litres capacity at CGRA pump house and type- II &II Pump House, TRV. Complete all as specified and directed having the following process as under:-
(a) Dewatering the tank including all dirt dust and mud.
(b) Desilting and removal of dirty water and sludge with wire brush inside wall and floor surface to remove impurities.
(c) Cleaning of walls,ceiling and bottom of tank by high pressure water jet and bleaching powder.
(d) Removing,shifting mud/impured material to a distance 10m away from sump.
(e) Writing the capacity and date of cleaning with white and black enamelled paint as directed.
QUANTITY 2+1=3
3
-
-
All as per item No 44 above but capacity of 1.5 Lakh gallen at TRV pump house. Complete all as specified and directed.
1
-
-
All as per item No 44 above but capacity of 12000 gallens capacity at 39.37 Acres, Pump House No I. Complete all as specified and directed.
1
-
-
All as per item No 44 above but capacity of 8000 gallens capacity at 39.37 Acres, Pump House No 2. Complete all as specified and directed.
1
-
-
All as per item No 44 above but over head water tank upto 18 mtr of staging (Height of water tank) of capacity 75000 gallen at TRV pump House. Complete all as specified and directed.
1
-
-
Taking out old flanged type CI pipe 100mm / 150mm alongwith connected accessories, relaying and jointing on wall of OH tank of min height 18m, rectifying where leaking by changing rubber gasket joint at CGRA pump house. Complete all as specified and directed.
2
-
-
Supply only "Bleaching Powder" for cleaning and treatment of swimming and divers pool water.. Complete all as specified and directed.
400
-
-
Supply only "Copper Sulphate" for cleaning and treatment of swimming and divers pool water. Complete all as specified and directed.
500
-
-
Supply only "TCCA - 90 (G)" for filteration plant of swimming and divers pool water. Complete all as specified and directed.
600
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%