Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 63,500Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_643712_1Tender No
8466/GOA/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://https://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M & L Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed.
600
-
-
M & L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
10.8
-
-
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade complete all as specified and directed.
216
-
-
M & L Providing cement concrete 1:2:4 Type B1 (using 20mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edge in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
1
-
-
Excavating in post holes or similar holes) each n exc 0.5cu. m, getting out, in soft / disintegrated rock returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed.
47
-
-
S & F Plates (Plain or chequerred) channels, square cut or notched (ordinary and counter sunk) forming holes with riveted, bolted or welded attachment complete all as specified and directed.
108
-
-
M & L Providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed.
750
-
-
Excavation in trenches n exc 1.50m wide and n.exc 1.50 m depth for foundation etc in Hard / dense soil complete all as specified and directed.
45
-
-
M & L 100mm thick Plain cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling complete all as specified and directed.
45
-
-
M & L Plain cement concrete Block masonry Type B1 1:2:4 with solid blocks exc 10cm in width and setting in cement mortar 1:4 complete all as specified and directed.
16.2
-
-
M & L Plain Cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) in coping complete all as specified and directed.
1.35
-
-
M & L Plain Cement concrete in surface channels and drains of Type B2 1:2:4 (using 40mm graded stone aggregate) complete all as specified and directed.
4.8
-
-
M & L Rendering 15mm thick in Cement mortar 1:6 on surfaces other than fair face of brick work finished even and smooth using sagol finish complete all as specified and directed.
140
-
-
Returning filling including spreading, levelling and well ramming in layers not exc 25cm complete all as specified and directed.
30
-
-
Removing execavated soil to a distance exc 250mtr but n.exc 500 mtr and depositing where directed complete all as specified and directed.
24
-
-
M & L Precast cement concrete 1:2:4 type B1 using 20mm graded stone aggregate for cover slab for Drain/ Man hole set in Cement mortar 1:4 complete all as specified and directed.
5
-
-
M & L Mild steel bars 10mm dia and over, cut tolength, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel TMT Bars complete all as specified and directed.
470
-
-
SCH A PART-II [ E/M PART]
S & F Fabrication, errection testing complete Hot dip galvanized IRON octagonal pole 9.00 metre long with 06 Nos arm bracket of size 1 mtr. with 40mm dia of GI pipe and 15 degree arm tilt suitable for wind speed up to 47 m/s, junction box. Dimension top 70mm and bottom 155mm, 3mm thickness, base plate 250mm x 250mm x 16mm as per BSEN ISO 146, with foundation bolts of 4 Nos of 24 mm dia 'J' EN8 grade bolt of length 750mm and projected bolt length 125mm with nut and washer with MS template all as specified. Including finial and necessary Civil works like RCC/ PCC foundation earthwork etc complete Including taking down existing Steel tubular pole complete all as specified and directed.
[Make: BAJAJ CAT NO BOP- 9030 or similar in make as mentioned in Particular Specification].
(i) Welding Standard:- IS:10178:1995/ IS 9535:1996.
(ii) Design:- As per IS 875 Part-3:2015, IS:800:2007/IS 6533:1989(P-2) /BS 5649:1985/EN 40
(iii) Galvanization Standard:- As per 4759:1996/IS:2629:1985/BSEN, ISO:1461:2009.
(iv) CIVIL WORK IN FDN:(i) Design & drawing of foundation / pole shall be submitted from manufacturer for approval of Engineer-in-charge.
(v) Cost of all civil works/ foundation works for fixing poles shall deem to be included in this item rate quoted by bidders, No extra cost in this regard shall be entertained in future.
[Note:- LED Flood light will be measured and paid under BOQ Item 22.00]
2
-
-
S & F LED Flood light 120 Watt 230 VAC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and directed.
12
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core
170
-
-
Excavation in trenches n.exc 1.5 m deep and n.exc 1.5 m wide and getting out in soft disintegrated rock/ laterite rock complete all as specified and directed.
42
-
-
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata complete all as specified and directed.
22.32
-
-
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
17.19
-
-
Supply/ Lay dry river sand/ M sand in trenches for cable protection complete all as specified and directed. [Note :- Punned thickness only will be measured & Paid.]
15.12
-
-
Supply and lay cable cover LV type 1 flate size 250mm x 150mm x 40mm for cable protection complete all as specified and directed.
1380
-
-
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sq mm 2 core complete all as specified and directed.
60
-
-
Supply, install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 200 Amps capacity, outdoor cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50mm x 50mm x 6mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings complete all as specified and directed.
1
-
-
INCOMING:-
(a) Multifunction panel meter with CTs
(b) MCCB with microprocessor based release, 4 pole, 63AMPS, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming), Indicator lamp with toggle switch set of 3. OUTGOINGS:-
(a) MCCB, 4 pole, 40 Amps, 50 Hz, 415 Volts, 25 KA -01 Nos (b) MCB TPN, 4 Pole 20 Amps, - 02 Nos (c) Analog Time switch with contactor 16 Amps -01 No
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements