Military Engineer Services Tender

View complete overview of Goa MES Tender

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date30 Nov 2018
Closing Date2 Jan 2019
Tender Amount₹ 39,88,390 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Returning ,filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick all as specified.

-

-

-

... More
Removing excavated material/soil from site to a distance not exc 50 m away and depositing where directed n.exc 1.5m from the starting point all as specified.

-

-

-

... More
Supplying & laying clear sand in trenches for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified. Note: Punned thickness of sand shall be measured and paid.

-

-

-

... More
Supplying & laying in repair precast concrete cable cover, class LV, type 1, flat, size 250mm x 150mm x 40mm in trenches to protect under ground cable complete all as specified.

-

-

-

... More
Supply and laying under ground LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade of cross sectional area 2 core 10 Sq mm with aluminium conductor, ISI marked as per IS : 7098( Part-1) along with suitable size aluminium cable lugs, gland if required and jointed in any description including taking down old unserviceable LT UG cable from any description (trenches, walls, ceilings., etc) from various locations,complete all as specified.

-

-

-

... More
All as per item No 8 here in before but of size 2 core 16 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 4 core 16 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 4 core 25 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 3 1/2 core 35 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 3 1/2 core 50 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 3 1/2 core 70 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 3 1/2 core 95 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 3 1/2 core 120 sqmm

-

-

-

... More
All as per item No 8 here in before but of size 3 1/2 core 150 sqmm Note for item No 8 to 17 :- 1. Excavation, PCC cable cover, GI pipe, PCC work for road crossing / hard standing and sand for cushioning will be measured and paid separately. 2. Cost of glands, aluminium cable lugs (eye lid/barrel / bottle neck type/ring type or any shape), new nut, bolt and washers of required size / description are deemed to include in this rate.

-

-

-

... More
M & L for PCC type D-2 ,1:4:8 using 40 mm graded stone aggregate including use and waste of form work using any description all as directed.

-

-

-

... More
M & L for PCC type C-1,1:3:6 using 20 mm graded stone aggregate including use and waste of form work using as coping or in any description all as dirceted.

-

-

-

... More
M & L for preparation of old painted concrete surface, cleaning the surface of the RCC pole (LT) above the ground level to top of the pole including coping area (if provides) with one coat of ACC exterior emulsion paint as per existing colour all as directed.

-

-

-

... More
Supply and fixing or laying in trenches / on wall / poles / structures as in repairs GI tubing light grade of size 100 mm dia for road crossing / for cable protection / fixing of light fittings etc including necessary provision for cable entry if required in lights pole, fixing screws complete all as specified and as directed.

-

-

-

... More
All as per Item No. 21 here in before but of size 80 mm

-

-

-

... More
All as per Item No. 21 here in before but of size 50 mm

-

-

-

... More
All as per Item No. 21 here in before but of size 40 mm

-

-

-

... More
M & L for earthing complete with GI earth plate, electrode,600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) mixed with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 3 of SSR Part-I and connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia up to 7.5 m from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed including demolition of existing earth pit and taking out old materials

-

-

-

... More
Supply and fixing in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 333 x 233 x 120 mm mm including necessary suitable size new aluminium bus bar 04 Nos mounted on saddles suitable for 3 phase 4 wire system of suitable length and thickness, provision of new aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of GI flat iron 25 x 3 mm, nut and bolt on poles complete all as directed .

-

-

-

... More
Supply and fix MCCB 4 pole, 415 volts with adjustable type 100 to160 Amps with breaking capacity 35 KA complete including necessary connection with suitable size aluminium / copper cable lugs including taking out the existing unserviceable MCCB from any description all as specified and as directed. Make : L & T Cat No SL98607OOOO or equivalent as approved.

-

-

-

... More
S & F in repairs HT / LT MS cable route indicator 4" dia fixed with two Nos of nut, bolt and washers and provision of PCC type D-2, 1 : 4 : 8 using 40 mm graded stone aggregate of not less than 0.05 cum in each at base buried under the ground including necessary earth work complete all as directed.

-

-

-

... More
Attending complaints for day to day repair / maint work for outer / inner perimeter / security / street / dispersal / high mast / search lights of any description at INS Hansa area by taking down carefully the existing non operational / unserviceable lights from any position for repair / replacement of unserviceable spares and re-fixing the same in the existing location after completion of repair work all as directed and as specified.

-

-

-

... More
Notes :- (a) All new spares for the above items will be measured and paid separately under relevent time of this schedule as " Supply only ". (b) The contractor / contractor's supervisor shall report to AGE E/M- I / INS Hansa maint office in all working days at 0900 hrs and collect the complaint slip for defect / unserviceable lights list at Hansa premises and carrying out and complete the repair work in the same day before 1800 hrs. If the contractor fails to complete the repair work within the 03 working days after receipt of complaint slip necessary recovery @ Rs 100.00 per complaint per day shall be recovered from the contractor . A register shall be maintained for this purpose and signed by both the Engr in Charge and contractor. (c) The rates quoted for the item includes for all tools and plants, safety equipments, transport including necessary minor spares such as insulation tape, connectors, fixing screws, connecting 2 core wires up to 2 m length . (d) All defected LED fittings and conventional type security light fittigs partially serviceable are to be deposited at the store yard of AGE E/M- I . (e) Each taking down and re-fixing shall be measured and paid separately.

-

-

-

... More
Supply only Heavy duty copper wound ballast for HPSV fitting 70 watts. Make : Cat Ref No. BJOS 70 SV/MH of Bajaj or equivalent in Philips / C & S as approved.

-

-

-

... More
Supply only Heavy duty copper wound ballast for HPSV / MH fitting 150 watts. Make: Cat Ref No.BJOS 150 SV/MH of Bajaj or equivalent in Philips / C & S as approved.

-

-

-

... More
Supply only Heavy duty copper wound ballast for HPSV/MH fitting 250 watts . Make:Cat Ref No.BJOS 250 SV/MH of Bajaj or equivalent in Philips / C &S as approved.

-

-

-

... More
Supply only Heavy duty copper wound ballast for HPS / MH Make: Cat No BJOS 400 SV/MH of Bajaj or equivalent in Philips / C & S as approved.

-

-

-

... More
Supply only lamp HPSV 250 watts eliptical type, base cap E - 40 all as directed. Make : Cat No HPSV 250W tubular of Bajaj or equivalent in Philips / C & S as approved.

-

-

-

... More
Supply only capacitor 10 Mfd 250V for luminaires HPSV fittings .

-

-

-

... More
Supply only capacitor 20 Mfd 250V for luminaires HPSV fittings.

-

-

-

... More
Supply only capacitor 33 Mfd 250V for luminaires HPSV fittings.

-

-

-

... More
Supply only electronic ignitor for HPSV/MH lamp fittings Make: Cat Ref No.BJIGN HPSV/MH-2 of Bajaj or equivalent in Philips / C & S as approved.

-

-

-

... More
Supply only Porcelain lamp holder, thread type suitable for 70 watt SV lamp fitting .

-

-

-

... More
Supply only Porcelain lamp holder, thread type suitable for 150/250/400 watts SV lamp fitting.

-

-

-

... More
Supply only street light bracket made out of GI tubing 40 mm dia of approx 1.2 m length , light grade ,bend to shape suitable for security light fittings with necessary GI clamps 40mm x 6 mm - 02 Nos including nut, bolt, washers etc .

-

-

-

... More
Supply and fix in repairs LED post top fittings with die cast aluminium body and with white powder coated aluminium reflector and IP-65 protection of 40 watts capacity all as directed. Make : Cat No BGCL 40W LED WH of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
Supply and fix in repairs LED post top fittings with die cast aluminium body and with white powder coated aluminium reflector and IP-65 protection of 45 watts capacity all as directed. Make : Cat No BRIL 45W LED NW of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
Supply and fix in repairs LED post top fittings with die cast aluminium body and with white powder coated aluminium reflector and IP-65 protection of 40 watts capacity all as directed. Make : Cat No BGCT W4 LED WW of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
S&F in repairs street light bracket made out of GI tubing 25/32 mm dia of approx 1.2 m length, light grade bend to shape suitable for security light / street light / Pigmi light fittings with necessary fixing arrangements by using GI clamps of 40 x 6 mm-02 Nos including nut, bolt, washers etc all as directed.

-

-

-

... More
S&F in repairs energy efficient LED street light luminaire 60 watts capacity comprises die-cast aluminium housing including connections with 2 run of 2.5 Sq mm aluminium unsheathed wire multistranded from LT over head line to the connector of fitting, connection wires not to be more than 2.5 metre in length duly run through GI bracket complete all as directed. Make : Cat No BRTFG 60W LED of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
All as per item No 46 here in before but of capacity 72 watts all as specified. Make: Cat No BRTFG 72W LED I of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
All as per item No 46 here in before but of capacity 90 watts all as specified. Make: Cat No BRTFG 90W LED I of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
All as per item No 46 here in before but of capacity 120 watts all as specified. Make: Cat No BRTFG 120W LED I of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
All as per item No 46 here in before but of capacity 150 watts all as specified . Make: Cat No BRTFG 150W LED I of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
Supply and fix in repairs galvanised iron cross arms channel , bracing , support, clamps etc fabricated structured steel , sections , including nuts, bolts , washers etc and cutting to required length , bend to any shape drilling holes , fixed on poles or jointed by means of electrical welding complete including taking down / dismantling the old items complete all as directed.

-

-

-

... More
S & F in repairs pin type porcelain vitreous, brown or white insulator of size 100 mm height, 65mm dia including one galvanised mild steel spindle , two galvanised iron washer and one GI nut , having working pressure of 1100 Volt complete all as directed.

-

-

-

... More
S & F in repairs shackle type porcelain, vitreous, white, brown or green insulator of size 100 mm height ,115 mm dia including galvanised mild steel straps, washers, insulator bolts, washers and nuts, having working pressure of 1100 volts grade complete all as directed. .

-

-

-

... More
Material and labour for providing new ACSR conductor including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes including dismantling of existing old unserviceable ACSR conductors of any size from any position , all as directed. Note : Rates quoted for this item shall include new AAC / aluminium wire for binding purpose

-

-

-

... More
Taking down the GI / PVC cable protection pipe along with UG cable from pole / wall by disconnecting all incoming and outgoing connections from the unserviceable street / security light junction boxes and breaking the pole coping, opening the cable loop kept under the pipe / any description by excavation of earth work, cut the damaged portion of UG cable of any size and making new termination arrangement etc,. cut the GI / PVC pipe of required length, fix the same in the existing pole by fixing new GI clamps , provision of new cable junction boxes IP 66 protected “halogen free and weather proof” suitable for outdoor type ( with metric knockouts for cable entry) of size 333 x 233 x 120 mm including necessary suitable size new aluminium bus bar 04 Nos mounted on saddles suitable for 3 phase 4 wire system of suitable length and thickness, street light connections, re-filling the excavated soils etc including making good the damaged coping by providing new PCC 1:3:6 & plastering in cement mortar 1:4 complete all as directed.

-

-

-

... More
S & F in repairs flying saucer light fittings suitable for retrofit 2 x 9 watts LED as light source including 2 Nos LED PL lamp 9 watts complete all as directed. Make : Bajaj or equivalent as approved.

-

-

-

... More
S & F in repairs retrofit /screw base type LED bulbs of 12/13 watts ,capacity 230 Volts all as directed. Make : Bajaj / Philips / Wipro.

-

-

-

... More
Supply and fix LED Flood light fittings 120 Watts including fixing arrangement and necessary connections including taking down of existing unserviceable flood light fitting of any type, complete all as directed. Make : Bajaj Cat No BARFEG 120W LED or equivalent in Philips / CG as approved.

-

-

-

... More
Supply and fix LED Flood light fittings 200 Watts including fixing arrangement and necessary connections including taking down of existing unserviceable flood light fitting of any type, complete all as directed. Make : Cat No BARFEG 200W LED of Bajaj or equivalent in Philips / CG as approved.

-

-

-

... More
Supply and fix LED Flood light fittings 240 Watts including fixing arrangement and necessary connections including taking down of existing unserviceable flood light fitting of any type, complete all as directed. Make : Cat No BARFEG 240W LED of Bajaj or equivalent.in Philips / CG as approved.

-

-

-

... More
Supply and fix Street light fitting single piece cast aluminium with full glass cover integral luminaires (IP66) 1 x 250 watts HPSV including necessary copper ballasts, ignitor, lamp complete, pre wired and connecting to existing connector including taking down of existing unserviceable street light fitting of any capacity from any description all as specified. Make : Cat No BGEST 250 SV FG SHN (IP66) of Bajaj or equivalent in Philips / CG as approved.

-

-

-

... More
All as per item No 61 here in before but of 150 watts capacity. Make :Cat No BGEST 150 SV FG SHN (IP66) of Bajaj or equivalent in Philips / CG as approved.

-

-

-

... More
S & F in repairs LED Aviation light fitting comprising of aluminium housing with polycarbonate enclosure, 302 Nos. LED are provided with necessary fixing arrangements & electrical connections all as directed. Make : Cat No BGAV 302 LED of Bajaj or equivalent as approved.

-

-

-

... More
S & F in repairs PCB for LED traffic signal light fitting 10/15 watts capacity IP- 65 with necessary enclosure, PCBs complete including fixing accessories like MS clamps, nut, bolts into the steel pole of Red / Green colours all as directed.

-

-

-

... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 2 core stranded aluminium conductor served with an inner sheathing of PVC tape PVC sheathed 4 sqmm nominal cross section in service connection / light connections in poles from junction box to fittings all as diretced

-

-

-

... More
M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 70 to 150 Sqmm aluminium cable all as directed.

-

-

-

... More
M & L for LT heat shrinkable cable Jointing kit suitable for 3.5 core 185 to 300 Sqmm aluminium cable all as directed.

-

-

-

... More
M & L for removing vegitation, grass, scrubs and bushes or any small tree branches growing in sub station yard along with fencing, around the pole, under the HT / LT transmission lines, yards or any position by manually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean throughout the period of contract and each cleaning will be measured and paid.

-

-

-

... More
M & L for cutting and trimming of tree branches of girth upto 150 mm dia and 3 m all around of any size obstructing lumination of street light/ perimeter lights and touching LT / HT over head line including removal of trimmed tree branches all as directed. Note :Each cut shall be measured and paid

-

-

-

... More
M&L for re-string of serviceable ACSR conductor of any size with new aluminium binding wire of suitable size including taking down the old one for replacement of pole / cross arms etc carefully all as directed. Notes:Rates quoted for this item shall include new AAC / aluminium wire for binding purpose

-

-

-

... More
S & F in repairs LED cup type street light luminaire 20 watts capacity comprises die-cast aluminium housing including connections with 2 run of 2.5 Sq mm aluminium unsheathed wire multistranded run through GI bracket complete all as directed. Make : Cat No BCLST 20W LED I of Bajaj or equivalent in Philips / Wipro as approved.

-

-

-

... More
Supply and laying 40 mm graded coarse aggregate (broken stone or boulders) in substation yard all as directed and specified.

-

-

-

... More
S & F in repairs LT PVC line spacer suitable for existing 3 phase 4 wire OHT system all as directed

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.