Military Engineer Services Tender

View complete overview of Goa MES Tender

Military Engineer Services - MES Tender

Works
Machinery and Tools
Eprocure
Opening Date31 Dec 2024
Closing Date20 Jan 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Motor of capacity 7.5 to 15 HP complete.

3

-

-

... More
Motor of capacity 1.0 to 5.0 HP complete.

2

-

-

... More
S&F DOL/ submersible starter in sheet metal enclosure, AC-3 phase, 415 Volts, 50 Hz, including taking out old unserviceable one all as specified and as directed of the following capacity :-

-

-

-

... More
Motor 10/7.5 HP, borewell Submersible Starter, AC, 3 Phase, 415 Volts complete.

1

-

-

... More
Motor upto 7.5 HP, DOL Starter, AC, 3 Phase, 415 Volts complete.

1

-

-

... More
M & L for removing existing Centrifugal pump set motor from base frame after disconnecting electrical connections and varnishing, heating and baking the winding of the motor complete and replacing bearings, grinding the shaft etc complete and reassembling and fixing back to original position and testing, commissioning etc all as directed complete for the following:- Notes :- (a) Replacement of major parts will be measured & paid separately. (b) Any minor part if required will be provided by contractor without any extra cost.

-

-

-

... More
Motor of capacity 50 to 60 HP complete.

1

-

-

... More
Motor of capacity 20 to 40 HP complete.

2

-

-

... More
Motor of capacity 10 to 20 HP complete.

3

-

-

... More
Motor of capacity upto 10 HP complete.

3

-

-

... More
M&L in replacement of coupling set with all accessories for Pump shaft of the following capacity pumping set, including machining, threading, making key slot etc. as directed.

-

-

-

... More
60/50 HP Pump Set complete.

1

-

-

... More
40/30 HP Pump Set complete.

2

-

-

... More
20/15 HP Pump Set complete.

2

-

-

... More
10/7.5 HP Pump Set complete.

3

-

-

... More
Removal of existing unserviceable Fan blade from pump set motor and replacing the same , reassembling and fixing back to original position and testing, commissioning etc all as directed.

2

-

-

... More
Supply only wornout stainless steel Ball bearing of existing size for the following size pumping set complete all as specified & as directed.

-

-

-

... More
60/50 HP Pumpset complete.

2

-

-

... More
40/30 HP Pumpset complete.

2

-

-

... More
20/15/12.5 HP Pumpset complete.

4

-

-

... More
10/7.5 HP Pumpset complete.

2

-

-

... More
5.0/3.0 HP Pumpset complete

2

-

-

... More
M&L in replacement of Pump shaft for following capacity pumping set, including sleeves, machining, threading, making key slot etc. complete all as directed.

-

-

-

... More
60/50 HP Pump Set complete.

1

-

-

... More
40/30 HP Pump Set complete.

2

-

-

... More
20/15 HP Pump Set complete.

2

-

-

... More
M&L for replacement of CI impeller of any capacity pumping set all as directed.

-

-

-

... More
40 to 60 HP Pump Set complete.

2

-

-

... More
Upto 30 HP Pump Set complete.

4

-

-

... More
M&L in replacement of gland coupling brass bush for the following pumping set all as directed:-

-

-

-

... More
(a) 60/50 HP Pumpset complete.

1

-

-

... More
40/30 HP Pumpset complete.

2

-

-

... More
20/15/12.5 HP Pumpset complete.

3

-

-

... More
0/7.5 HP Pumpset complete.

1

-

-

... More
Removal of existing submersible pump set of any capacity from the existing borewell (by using any method) of depth upto 200m and transporting to workshop for checking and bringing back after repair, reinstalling of submersible pump set in the borewell including testing and commissioning complete all as directed. Note :- (i) The quoted rate shall be deemed to include the cost of any T&P or machinery required for carrying out the work (ii) Replacement/Repair will be measured seperately as supply only items

2

-

-

... More
Supply only the following spare parts for submersible pump :-

-

-

-

... More
GM impeller complete.

6

-

-

... More
GM Neck ring complete.

2

-

-

... More
Coupling sleeve complete.

2

-

-

... More
MS Stud for pump complete.

2

-

-

... More
Bush for submersible motor complete.

4

-

-

... More
Thrust plate complete.

2

-

-

... More
Bush for pump complete.

4

-

-

... More
Repairs to AC, 3 phase, 415 Volts, 2900 RPM Electric Submersible pumping motor 10 HP against item no 11 above including Dismantling of burnt motor, cutting and taking out burnt stator winding from motor, cleaning the stator and rewinding with super enamelled water proof copper wire of original gauge/size including re-assembling complete all as specified and as directed.

1

-

-

... More
All as above item no 12 but for 1.5 to 5 HP complete.

3

-

-

... More
M&L periodical servicing of 85 BHP diesel engine driven fire fighting pumpset 3 phase 415 volts 50 c/s AC supply by cleaning thoroughly and replacing fuel filters ,air filters, oil filters draining out engine oil etc. and replacing with new oil, tightening of all gaskets, connection of battery terminals, electric cable connections foundation bolts, coupling bolts etc including test running and tappet setting all as directed by Engr-in-charge. Make of engine : Kirloskar/ Crompton greaves/Cummins or equivalent approved. Note : Engine oil, Fuel filters, Air filters, oil filters replaced will be measured and paid separately under respective item of sch 'A' . for following capacities of diesel operated pumpset.

3

-

-

... More
M&L to drain out the old used engine oil from sump of DG sets & cleaning, refilling with new engine oil 15 W 40 up to required level including topup Make : Castrol/ HP or equivalent approved.

60

-

-

... More
Supply Only coolant for different capacity of diesel engine driven pumpset complete all as specified and direced.

30

-

-

... More
S & F in repairs air filter both inner and outer for diesel engine driven pumpset complete all as specified & directed.

3

-

-

... More
S & F in repairs fuel feed pump for diesel engine driven pumpset complete all as specified & directed.

1

-

-

... More
M&L for replacement of head gasket complete as per sample all as specified and directed.

2

-

-

... More
M&L for replacement of UNSV radiator hose pipe set complete as per sample of diesel operated pumpset of 85 BHP complete all as specified & directed.

1

-

-

... More
M & L for replacement of UNSV V- belt as per sample for 85 BHP diesel operated pumpset complete all as specified & directed.

2

-

-

... More
Supply only Diesel Filter suitable for 85 BHP diesel operated pumpset complete.

3

-

-

... More
Supply only Lub Oil filter suitable for 85 BHP diesel operated pumpset complete.

3

-

-

... More
Supply & fixing in repairs battery terminals brass type suitable for any capacity battery complete all as specified & directed.

6

-

-

... More
Cleaning of fuel tank of fire fighting pumpset any size capacity including draining out existing fuel, removing any foreign particles or sediments including checking of leak proof if found rectifying the same by necessary welding fabricating with sheet metal, matching with existing tank outer body, preparation of surface for painting with one coat of black synthetic enamel paint over a coat of red oxide primer and refilling the same as specified and directed.

1

-

-

... More
Material & Labour in repair to self starter 12 Volts by taking out old burnt out copper winding and rewinding with super enammelled copper wire same gauge complete in commisioning and testing all as specified & directed.

1

-

-

... More
Supplying, installation, testing and commissioning in repair of Electronic battery charging set suitable for charging batteries 12 V, 10/12 Ampswith required size of copper wire up to required length and 1No. 3 pin plug top 5 Amps complete all as specified

1

-

-

... More
Dismantling the old unserviceable diesel/oil pressure pipe and replacing the same with of existing size and equal length of any capacity fire fighting pumpset including both side hose clamp etc as directed.

2

-

-

... More
S & F in repairs solenoid swtich 3 phase 415 Volt complete set as per existing size and make complete all as specified and directed.

1

-

-

... More
Supply and fixing in replacement of maintenance free battery with initially charged capacity 100 AH , 12 Volt complete all as specified & directed.

1

-

-

... More
Taking down existing submersible pump set of any capacity from the existing borewell (by any means) of depth up to 150 mtr and flushing out till clear water is obtained, conducting yield test with 'V' Notch and reinstallation of submersible pump set in the bore well complete all as directed. Note : The quoted rate shall be deemed to include the cost of any T&P or machinery required for the complete flushing out of the bore well and testing and commissioning of submersible pumpset complete all as specified & directed.

1

-

-

... More
Supply and fixing in repair submersible cable ,flat, PVC insulated copper conductor stranded type, 1100 volts grade of size 3 core 6 sq. mm size, including jointing of cable with proper kit, connecting to motor and starter with suitable thimble including dismantling the old one complete all as specified and as directed.

120

-

-

... More
Supply and fixing in repair submersible cable, flat, PVC insulated copper conductor stranded type, 1100 volts grade of size 3 core 2.5 sq. mm size, including jointing of cable with proper kit, connecting to motor and starter with suitable thimble including dismantling the old one complete all as specified and as directed.

200

-

-

... More
M & L for dismantling sewage pumping set 12.5/20 HP pump set by dismantling of suction & discharge pipe line and motor, cleaning the pump by removing the impellar / repair work / over hauling and replacement of worn out parts all as required to bring the pump in perfect working condition including re-assembling installing, testing and commissioning complete all as specified and directed. Note- (i) Cost of minor spare will be born by the contractor (ii) Other spares will be measured and paid seperately

2

-

-

... More
Supply only under mentioned worn out parts of sewage pumping set :-

-

-

-

... More
Pump shaft for 20 /12.5 HP pumping set incl machining, threading, making key slot etc. complete.

1

-

-

... More
Cast iron impeller for 12.5/20 HP Pump complete.

2

-

-

... More
Gland bush for 12.5/20 HP complete.

2

-

-

... More
Ball bearing suitable for 12.5/ 20 HP pump set complete.

3

-

-

... More
Coupling set for MS shaft of 12.5/ 20 HP pump set complete.

2

-

-

... More
Fish Plate bush complete.

1

-

-

... More
Nuts & bolts off sizes complete.

4

-

-

... More
Supply and fix in repairs Cast Iron ball type Foot valve flanged end, including all necessary fittings ie rubber gasket, nuts & bolts, washers all as specified and directed of the following nominal sizes:-

-

-

-

... More
125 to 150 mm bore complete.

4

-

-

... More
80 to 100 mm bore complete.

6

-

-

... More
M & L in repairs swing check type reflux (Non- return) valve,cast iron body, single door, both ends flanged type including all necessary fittings ie rubber gasket, nuts & bolts, flanges, washers of the following nominal sizes :-

-

-

-

... More
125 to150 mm bore complete.

2

-

-

... More
100 mm bore complete.

4

-

-

... More
80 mm bore complete.

2

-

-

... More
Supply and fix in repairs cast iron sluice valve with stainless steel spindle, class PN-1.6, both ends flanged and drilled and fixed by means of new bolts, nuts and washer of galvanised iron of suitable size , including providing and fixing rubber gasket joints with rubber gasket 3mm thick of the following nominal sizes complete all as specified and directed:-

-

-

-

... More
100 mm bore complete.

2

-

-

... More
80 mm bore complete.

1

-

-

... More
Supply and fix in repairs Gun metal gate valve, (heavy duty) with iron wheel head, secrewed both ends for iron pipe all as specified and directed of the following sizes :-

-

-

-

... More
50 mm bore dia complete.

2

-

-

... More
25 mm bore dia complete.

2

-

-

... More
20 mm bore dia complete.

2

-

-

... More
15 mm bore dia complete.

1

-

-

... More
Supply and fix in repairs Brass Foot valve screwed type, including all necessary fittings complete all as specified and directed of the following nominal sizes:-

-

-

-

... More
100 mm bore complete.

2

-

-

... More
80mm bore complete.

2

-

-

... More
50 to 65 mm bore complete.

1

-

-

... More
Supply and fixing in repair of fire hydrant landing valve type A (single head outlet) with flanged inlet of 63 mm dia of size oblique outlet female instantaneous type coupling having spring loaded lugs; internal parts shall be copper or gunmetal. A cap (made up of Gun metal)with chain shall be provided on the outlet of the valve, which have 63mm instantaneous pattern female coupling confirming and marked IS-903 including taking down existing unserviceable valve complete all as specified and directed.

3

-

-

... More
Supply and fixing in repair of fire hydrant landing valve type A (double headed outlet) with flanged inlet of 63 mm dia of size oblique outlet female instantaneous type coupling having spring loaded lugs; internal parts shall be copper or gunmetal .A cap (made up of Gun metal)with chain shall be provided on the outlet of the valve, which have 63mm instantaneous pattern female coupling confirming and marked IS-903 including taking down existing unserviceable valve complete all as specified and directed.

1

-

-

... More
Supply and fixing in repairs of 15m long and 63mm dia RRL fire hose with external coat of synthetic fibre and EPDM rubber lining from inside conforming to IS 636 with ISI mark along with ISI marked brass coupling, ISI marked with 63mm instanteneous male inlet including taking out existing hose from position complete all as specified. Make:Newage/Fire marshall/safe guard/OMEX

4

-

-

... More
Supply, lowering and fixing into bore hole GI column pipe 50 mm nominal bore both side socketted of suitable size complete all as specified and directed.

120

-

-

... More
S & F in repairs Voltmeter, digital type, 0 to 600V range, flush mounting type, three phase, 415V, AC with 3 phase selector switch, including dismantling old one complete all as specified and as directed.

5

-

-

... More
S & F in repairs Powerfactor meter, digital type, 0 to 1 range, flush mounting type, three phase, 415V, AC including all necessary accessories and dismantling old one complete all as specified and as directed.

2

-

-

... More
S & F Ammeter, digital type, 0 to 100 A range, flush mounting type, three phase, 415V, AC with CT's of ratio 100/5 A in all three phases with 3 phase selector switch, including dismantling old one complete all as specified and as directed.

4

-

-

... More
S & F in repairs indicator lamp LED type, 230 Volts, AC (different colours for indicating R, Y, B phases) with holder incl dismanlting old one complete all as specified and as directed.

8

-

-

... More
S & F in repairs Single phase preventer and connected to existing strater, suitable for centrifugal pump set of capacity 03 HP to 60 HP complete all as specified and directed.

17

-

-

... More
M & L for In repairs synthetic rubber insulated chequred mat 2mm thick for voltage upto 3.3 kv for electrical purpose as per IS15652-2006, suitable for electrical shock safety of sizes 2 m x 1 m complete all as specified and as directed.

10

-

-

... More
Supply and fixing in repairs power contactor, 3 pole, AC, type MNX 70 complete all as specified and as directed.

2

-

-

... More
Supply and fixing in repairs power contactor, 3 pole, AC, type MNX 50 complete all as specified and as directed.

6

-

-

... More
Supply and fixing in repairs power contactor, 3 pole, AC, type MNX32 complete all as specified and as directed.

6

-

-

... More
Supply and fixing in repairs power contactor, 3 pole, AC, type MNX 18 complete all as specified and as directed.

6

-

-

... More
Supply and fixing in repairs power contactor, 3 pole, AC, type MNX 12 complete all as specified and as directed

4

-

-

... More
Supply and fixing in repairs , 3 pole power contactor, 3 pole, type MK 1 complete all as specified and as directed.

2

-

-

... More
Supply and fixing in repairs, front mounting Add on Auxillary contact block type MNX A1 with 2 NO + 2 NC complete all as specified and as directed.

4

-

-

... More
Supply and fixing in repairs, front mounting Add on Auxillary contact block type MNX A2 with 1 NO + 1 NC complete all as specified and as directed.

4

-

-

... More
Supply and fixing in repairs, bi-metallic overload relay type MN 5 with single phase protection mounted on the contactor with current carrying capacity ranging from 30 - 50 A complete all as specified and as directed.

2

-

-

... More
Supply and fixing in repairs, bi-metallic overload relay type MN 2 with single phase protection mounted on the contactor with current carrying capacity ranging from 9-15 A complete all as specified and as directed.

3

-

-

... More
Supply and fixing in repairs, bi-metallic overload relay type MN 2 with single phase protection mounted on the contactor with current carrying capacity ranging from 20-33 A complete all as specified and as directed.

4

-

-

... More
Supply and fixing in repairs, bi-metallic overload relay type MK1 mounted on the contactor with current carrying capacity ranging from 0.6 - 18 A complete all as specified and as directed.

2

-

-

... More
Supply and fixing in repairs electronic timer ST-100 type ranging from 3 - 10 sec/ 12-120 sec complete all as specified and as directed.

6

-

-

... More
S&F in repair for MCCB , 4 - pole, 415 volts, 200 Amps,breaking capacity 50 kA, with thermal magnetic and microprocessor release including taking down old/ unserviceble MCCB complete all as specified and directed.

1

-

-

... More
S&F in repair for MCCB , 4 - pole, 415 volts, 160 Amps,breaking capacity 50 kA, with thermal magnetic and microprocessor release including taking down old/ unserviceble MCCB complete all as specified and directed.

1

-

-

... More
S&F in repair for MCCB , 4 - pole, 415 volts, 125 Amps,breaking capacity 50 kA, with thermal magnetic and microprocessor release including taking down old/ unserviceble MCCB complete all as specified and directed.

1

-

-

... More
S&F in repair for MCCB , 4 - pole, 415 volts, 100 Amps,breaking capacity 50 kA, with thermal magnetic and microprocessor release including taking down old/ unserviceble MCCB complete all as specified and directed.

4

-

-

... More
S&F in repair for MCCB , 4 - pole, 415 volts, 63 Amps,breaking capacity 50 kA, with thermal magnetic and microprocessor release including taking down old/ unserviceble MCCB complete all as specified and directed. Make - Legrand/ABB/Havells

4

-

-

... More
Servicing and maintaining pumping installation by tightening / replacing the gland rope of pump ,replacing rubber coupling ,bushes and clearing the leakage of sluice valves, NRV's, aircock, by tightening gland etc. complete at BMF Pump house comprising 4 Nos pump sets of capacity 30 HP -02 No & 40 HP - 02No complete all as specified and as directed.

1

-

-

... More
M & L for replacing rubber coupling of coupling set of any pumpset at different pump house complete all as specified and as directed.

6

-

-

... More
M & L for welding work for the broken pipe flanges / pump set base channel including necessary additional required material, checking/ correcting the alignment of pumpset including removing & refixing, cleaning the dust, rust and necessary painting all as specified and directed

1

-

-

... More
M& L preparation of old painted surface of pump installation by removing all dirt, dust, grease, oil etc and painting complete with two coats of synthetic enamel paint of approved colour over a coat of red-oxide primer in Pump set - 04 Nos including their sluice valves, NRV and delivery/ suction pipe line in BMF pump house all as specified & directed

1

-

-

... More
All as per serial item 72 here-in-before, but at NOFRA Pump house comprising 06 pump sets including valves-06, NRV-6 complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at new Trishul Pump house comprising 02 pump sets, 01 DG Operated pumpset, 01 No main fire pump,01 No Jockey pump including valves-06, NRV-4 complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at new 404 Pump house comprising 02 pump sets, 01 DG Operated pumpset, 01 No main fire pump, 01 No Jockey pump including valves-04, NRV-4 complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at new Kriti Enclave Pump house comprising 02 pump sets, 01 DG Operated pumpset, 01 No main fire pump, 01 No Jockey pump, including valves-04, NRV-4 complete

1

-

-

... More
All as per serial item 72 here-in-before, but at new Raksha Pump house comprising 02 pump sets, 02 Nos Booster pump including valves-04 Nos complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at 203 Pump house comprising 05 pump sets complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at new Varunapuri Pump house comprising 03 pump sets including valves-03, NRV-5 complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at Mangoor Pump house comprising 02 pump sets including valves-02, NRV-2 complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at Sewage Pump House comprising 02 pump sets including valves-03, NRV-3 complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at new Acharya Pump house comprising 02 pump sets, 01 No Booster pump including valves-02 Nos

1

-

-

... More
All as per serial item 72 here-in-before, but at Def Civ area pump house comprising 02 pump sets complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at New leading pump house area comprising 02 pump sets including valves-02, NRV-2 complete.

1

-

-

... More
All as per serial item 72 here-in-before,but at 24 Lt's pump house comprising 02 pump sets complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at Under Water Range area comprising 02 pump sets complete.

1

-

-

... More
All as per serial item 72 here-in-before, but at DAD complex pump house comprising 02 pump sets complete.

1

-

-

... More
M & L for bacteriological analysis of water sample at DIRECTORATE OF HEALTH SERVICES, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA complete all as specified and as directed. NOTE : (a) The water sample should be carried in sterilised bottle/watercan which are to be collected from the SCIENTIFIC OFFICER, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA) by the contractor Note: Testing to be carried out every month and test report shall be kept in records by AGE E/M.

78

-

-

... More
M & L for Chemical analysis of water sample at DIRECTORATE OF HEALTH SERVICES, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA complete all as specified and as directed. (NOTE : (a) The water sample should be carried in sterilised bottle/watercan which are to be collected from the SCIENTIFIC OFFICER, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA) by the contractor Note: Testing to be carried out every month test report shall be kept in records by AGE E/M.

78

-

-

... More
M&L chemical analysis of treated sewage water collected from STP 260 KLD at NOFRA II location for the following parameters:- (a) BOD (b) COD (c ) Oil and Grease (d) Suspended Solids(TSS) (e) Ph (f) DO (g) E- Coil (h) Coliform NOTE : (a) The water sample should be carried in sterilised bottle/watercan which are to be collected from the SCIENTIFIC OFFICER, ENVIRONMENTAL AND POLLUTION CONTROL WING, PANAJI- GOA) by the contractor (b)Testing to be carried out every month test report shall be kept in records by AGE E/M.

6

-

-

... More
M&L Plate earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected using galvanised iron strip 25× 3.15mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel , including provision of GI pipe 40 mm bore medium grade of required length for protection of earthing lead, GI watering pipe 15mm bore medium grade with PGI sheet funnel and wire mesh , PCC 1:3:6, type B-1 chamber with 50 mm thick pre-cast RCC cover reinforced with 6 mm dia mild steel plain round bars spaced at 100 mm centres both ways with frame, filling the pit with charcoal & common salt surrounding the earth plate,including all necessary excavation & earth work in any type of soil all as shown in Electrical Plate No.3, connected to earthing test point including testing on completion complete all as specified & directed

10

-

-

... More
Checking of pumpset starter or motor for any fault installed at various locations under AGE E/M II of GE(NW) Vasco and carry out necessary repairs in order to keep in working condition Note:- (a) Repairs including material required will be measured and paid under relevant item if required. (b) Equipments/Testing meters required for detecting faults shall be provided by the contractor.

18

-

-

... More
S&F in repair RGB light fittings LED water tight type of reputed make as per sample including necessary wiring and service connection all as directed

16

-

-

... More
Supply and fix in repairs to nozzle made out of brass of spraying assembly complete (As per sample)

20

-

-

... More
M&L for overhauling the fountain assembly comprising of cleaning the nozzles, changing the founatin PVC flexible pipe, painting the assembly, replacing the nozzles if required, rubber gasket , checking electrical connections for lights and pump & redoing with water proof tape etc including minor items required all as specified and as directed

3

-

-

... More
Repair to motor shaft / pump shaft including transporting to work shop, grinding, making slot for key if required, polishing and fixing back to position as earlier all as directed.

1

-

-

... More
M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in for foundation with grouting nut & bolt with necessary form work etc including dismantling pumpset with delivery and suction lines and making necessary alteration by fixing pipe and bend, refixing & realigning again after doing foundation at NOFRA Pump House complete all as specified and directed

1

-

-

... More
Supplying, laying, commissioning, jointing & testing 25 Sqmm, 4 core XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cable complete all as specified & directed. Note: Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ.

320

-

-

... More
Excavation in trenches (hard/dense soil), not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, valve pits, wells, cesspits, manholes, pier holes,laying of cables/pipes etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.

41.04

-

-

... More
Excavation in trenches (soft/ disintegrated/ laterite rock) & road, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, valve pits, wells, cesspits, manholes, pier holes,laying of cables/pipes etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.

41.04

-

-

... More
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed.

5.47

-

-

... More
Removal of surplus excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.

76.61

-

-

... More
M&L sand cushioning with dry local sand for cable protecting under ground cable (8 cm before laying the cable and 15 cm after laying the cable) in trenches and consolidated complete all as specified and directed. NOTE : Punned thickness 18 cm only shall be considered for payment.

24.62

-

-

... More
Supply and lay reinforced precast concrete cable covers, class LV, Type- I flat, size 250x150x40mm, ISI marked all as specified and directed.

1824

-

-

... More
Supply and fixing galvanised steel tubes, 50 mm light grade for cable protection all as specified and directed.

18

-

-

... More
Supply, installation, testing and commissioning of 3.15 mm thick CRCA sheet, hutted roof, cubical factory made outdoor (kiosk) type feeder pillar box weather proof and vermin proof outdoor mounting of suitable size, 415 volt, 4 wire, AC 50 Hz, with approved paint with power coated with front opening having degree of protection as per IP-54 class protection, complete factory lock two earth terminal suitable cable gland for all incoming and outgoing and removable neutral link, connecting strip /solid conductor brought out to cable chamber brass/copper nut, bolts/ washer etc including grouting of feeder pillar box 60 cm above ground level by providing 90 cm long angle iron of size 50 x 50 x 6 mm, welded on all the four corner embedded in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate) upto 30 cm including excavation and earth work and taking down existing feeder pillar box complete with following asseccories :-

1

-

-

... More
Incoming :- (a) Aluminium busbar with PVC insulated high conductivity 100 Amp rated 3 phase -04 Nos. (b) MCCB TPN 63 Amps 4 pole - 01 No breaking capacity 36 kA, 50 HZ with thermal magnetic release - 01 No. Outgoing :- (a) Submersible pump starter (3 -phase, 415 volt, 50 Hz) of capacity 3 to 7.5 HP. Make of Starter : L&T Model No : MU -G10

-

-

-

... More
S & F in repairs Framed work such as ladders, walk ways, railings & hand rail, shed and frame work for pump channel water supply installation and similar work including cutting tops to shape, drilling holes, notching for wire etc embedded in concrete / masonary complete duly painted with two coats of primier and one coat on synthetic enamel paint, drilling, bolting or reveting con-forming to Fe.290.Gde-E-165 including fixing it on required surface with necessary cement and welding work complete all as specified.

150

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.