Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 1,24,300Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694394_1Tender No
85918/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed
18
-
-
... More
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats,distance pieces,bolting, welding etc
1800
-
-
... More
S&F Polyolefin all weatherproof Co-polymer anti bird net in UV Black colour of mesh size 25mm x 25 mm (+/-2mm with Mesh breaking strength 12 kgf) having twine dia 1.00 mm(Twine breaking strength 16 kgf) as in vertical to be fitted in Hangar door top rails assembly using rope(wire) and pully system hanging from a height of up to 28 metres etc all as specified and directed by Engr-in-charge. Note: Rates are inclusive of material, fixing,scaffolding/ladder, pully arrangement to work at ht. upto 28 m.
1000
-
-
... More
Preparing new surfaces of iron and steel and applying one coat of redoxide zinc chrome primer and two coats of Epoxy anti- corrosive paint over 10 cm width or girth all as specified and directed
300
-
-
... More
M&L for preparation of old steel surface and applying one coat of Epoxy anticorrosive paint over 10 cm width or girth all as specified and directed
2000
-
-
... More
S & F in repairs LED High bay luminaires 1 x 200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source and taking down old unserviceable light all as specified and as directed.
48
-
-
... More
Supply and fixing of wire meshing for protection of high bay lights with opening arrengement for reparing of light incase of unserviceability of hangar highbay lights at hanger compleat all as specified and as directed by engineer- in -charge.. Note :- (i) All acessories i.e( Nut ,bolt, washer and hanging rods) for fixing of wire meshing are included in this rates. (ii) safty precution i.e( safty belt ,helmate,rope etc) are demade in this quited rate becouse hangar height (iii) Rates of T&P are included in this quited rate.(iv) Rates of labour insurence for fixing of wire meshing are included in this rates
48
-
-
... More
Supply and fix in repairs of LED Floodlight luminaire 200 watts capacity with secondary optics made in pressure die cast housing and heat sik in aluminium extrusion and IP66 Protection fixed in the AOL bracket of High mast light fittings all as specified and as directed.
8
-
-
... More
Taking down carefully any type of copper/aluminium point wiring (light,fan, socket or power) complete including conduits/casing caping with fittings such as switches,ceiling roses, pendents,regulators,bells, sockets, tube light fittings etc, removing the materials/debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed
54
-
-
... More
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC conduit pipe type of as required width (not less than 20 mm in width/25 mm dia conduit) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 2 mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers and including provision of modular metal flush box, modular cover plate with frame top cover for mounting switches, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed
20
-
-
... More
All as per item No. 13 here in before, but for one fan/exhaust/wall fan point controlled by one 5 Amp all as specified and as directed.
18
-
-
... More
All as per item No. 13 here in before, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed
8
-
-
... More
All as per item No 13 above, but with 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switch on the independent board complete all as specified and as directed.
8
-
-
... More
Taking down unserviceable any type of copper/aluminium sub main wiring of any type/size/core/ type complete including conduits/casing caping etc, removing the materials/debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
750
-
-
... More
M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC conduit of suitable width medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall/iron structure along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/ distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC conduit 25 mm dia shall be measred as one unit)
400
-
-
... More
All as per item No 18 here in before, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed.
200
-
-
... More
All as per item No 18 here in before, but four run of single core 10 sqmm and two runs of 10 sqmm cables as earth continuity conductor all as directed.
60
-
-
... More
All as per item No 18 here in before, but four run of single core 16 sqmm and two runs of 16 sqmm cables as earth continuity conductor all as directed.
90
-
-
... More
S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed
46
-
-
... More
S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed
8
-
-
... More
S & F Socket, 6A - 2/3 pin combined 2 module, all as directed.
8
-
-
... More
S & F Socket 6A/16A - 2/3 pin combined 2 module, all as directed.
8
-
-
... More
S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed
38
-
-
... More
Taking down unserviceable any type of Main Switch, DB's including MCBs incl wooden/GI/MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
14
-
-
... More
S & F in repairs MCCB DB VTPN, 8 way, (MCCB + 24 way O/G) double door, vertical type icluding provision of one MCCB of 100 amps breaking capacity 25 KA , all connections to be done with proper thimbling and neutral link, fixed flush in wall including chases wall for fixing DB, SUITABLE FOR TP/FP ‘G FRAME’ MCCB and making good distributed wall surfaces to match with existing specification, 4 pole without MCB complete all as specified and as directed
2
-
-
... More
S&F MCB DB TPN double door 04 way 415 volts all as specified and directed.
3
-
-
... More
Supply and fix in repairs MCCB of 100 to 125 A breaking capacity 25 KA , 4 pole thermal magnetic release, compact type suitable for LT panel as incoming/outgoing in the existing. complete all as specified and as directed
10
-
-
... More
Supply and fix in repairs MCCB of 250 A breaking capacity 36KA, 4 pole thermal megnetic release, compact type suitable for LT panel as incoming/outgoing in the existing. complete all as specified and as directed
2
-
-
... More
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
2
-
-
... More
S & F in repairs MCB TPN 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
1
-
-
... More
S & F in repairs MCB TP 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
4
-
-
... More
S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
4
-
-
... More
S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
4
-
-
... More
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
36
-
-
... More
S & F in repairs wall mounting Plug and socket DBs TPN 63 Amp Complete all as specified.
2
-
-
... More
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engr-in-charge.
8
-
-
... More
S & F in repairs wall mounting Plug and socket DBs TPN 32 Amp Complete all as specified.
4
-
-
... More
Taking down serviceable/unserviceable any type ,size of cable and securing fixing with clamp nut/bolts tie wire etc and making good the disturbed area etc all as specified and as directed.
450
-
-
... More
S & F Energy efficient surface Mounted LED Luminire 20 watts 4' long, with acrylic cover aluminium body complete all as specified and directed by Engr-in-Charge.
20
-
-
... More
S&F in repairs integral LED aviation light comprising of aluminium housing with polycarbonate enclosure with necessary fixing arrangement such as GI pipe, fixing clamp, brackets, etc., complete all as specified.
2
-
-
... More
M& L in repairs of Air circulator wall mounted type 450 mm to 600 mm sweep,taking down fans, replacing old deteriorated fan blades with new blades, rewinding of motor, replacing all rusted iron support rods, screw ,nut-bolts, washer etc, cleaning of full body and painting with same colour as existing and replacing of rusted fan blade covering and refixing at same location complete all as directed by Engr-in-charge.
18
-
-
... More
M & L for Earth Continuity conductor as Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground along with taking out old unserviceable complete all as specified and directed by Engr-in-charge.
586
-
-
... More
M & L for Air termination, single pointed, Alluminium rod 12 mm dia and 300 mm long , mounted on alluminium base plate of size 100mm x100mmx 12mm rigid fixed on top roof height complete and insulated from base and taking out old unserviceable complete all as specified and directed by Engr-in-charge.
21
-
-
... More
M & L for test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm drilled and scrwed including 3 Nos. 8 mm dia 25 mm long hex. Head screw complete all as specified and directed by Engr-in-charge.
4
-
-
... More
Supply and lay pipe galvanized, “ Light grade ”, including fittings 40 mm dia for protecting earth strip laid on ground/wall/poles with necessary fixing arrangements complete all as directed.
8
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%