Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_MES_504195_1Bid Award Id
ViewTender No
85559/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M&L for screed bed or bedding layer of morter 15 mm thick cement plaster 1:6 for laying floor tiles all as specified and as directed.
1608
-
-
... More
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles all as specified and as directed.
1608
-
-
... More
M & L for rendering 10 mm thick in cement mortar 1:4 on fair faces of stone masonry wall surfaces, finished even and fair to receive glazed tiles all as specified and as directed.
440
-
-
... More
S & F glazed ceramic tiles, coloured of size 300 x 200 x 7 mm thick with on vertical surfaces such as dado, skirting etc, set and jointed in neat cement slurry and pointed in white cement to match all as specified and as directed.
440
-
-
... More
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
112
-
-
... More
M&L for machine cut Kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
28.8
-
-
... More
M&L for screed bed or bedding layer of mortar 20 mm thick cement plaster 1:4 for laying floor finished to receive Kota stone all as specified and as directed.
112
-
-
... More
M&L for rendering 10mm thick cement mortar 1:4 on fair faces on brick work or concrete surfaces, finished even and fair to receive kota stone all as specified and as directed.
28.8
-
-
... More
Taking down cement plastering at any description on brick or stone wall etc including raking out joints hacking for key scrubbing down with water etc and removal of debries and depositing where directed all as specified and as directed.
1216
-
-
... More
M&L for rendering 10 mm thick in cement mortar 1:6 on concrete solid block wall internal surface finished even and smooth without using extra all as specified and as directed.
336
-
-
... More
M&L for rendering 15mm thick plaster in cement mortar 1:4 in two coats (10 mm thick backing coat + 5mm thick finishing coat) finished even and smooth without using extra cement including mixing of water proofing compound etc complete all as specified and directed. Note : Water proofing compound shall measured and paid separately
400
-
-
... More
M&L for rendering 5 mm thick in cement mortar 1:3 in ceiling finished even and smooth without using extra cement all as specified and as directed.
480
-
-
... More
M&L for applying two coat of oil bound distemper on old ceiling including preparation of surface and surfaces with alkali resistant priming paint all as specified and as directed.
320
-
-
... More
M&L for applying two coat of oil bound distemper on new ceiling including preparation of surface and surfaces with alkali resistant priming paint all as specified and as directed.
480
-
-
... More
M&L for applying two coats of oil bound distemper on old wall surfaces including preparation of surface all as specified and as directed.
1800
-
-
... More
M&L for preparing newly plastered of external wall surface and applying two coats of water proofing treatment by using araldite builder barrier coat (epoxy based) or equivalent @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat alongwith suitable pigments for colour as directed by Engineer-in-Charge all as specified in manufacturer's instructions and to be applied through applicator of authorised manufacturer with 5 Years guarantee.
400
-
-
... More
M&L for existing treatment of external wall surface and applying two coats of water proofing treatment by using araldite builder barrier coat (epoxy based) or equivalent @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat alongwith suitable pigments for colour as directed by Engineer-in-Charge all as specified in manufacturer's instructions and to be applied through applicator of authorised manufacturer with 5 Years guarantee.
250
-
-
... More
M&L for 2nd class hard wood for Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints all as specified and as directed.
0.35
-
-
... More
S & F 30mm thick Flush shutter , solid core construction with block board core and plywood face panels, commercial type on both side all as specified and as directed.
18.53
-
-
... More
Taking down and refixing of shutter of any description exc 1 Sqm and n.exc 2 Sqm all as specified and as directed.
10
-
-
... More
M&L for 3mm thick wall care putty on wall all as specified and as directed.
1000
-
-
... More
Supply only liquid water proofing compound all as specified and as directed.
40
-
-
... More
Dismantling structural steel work including doors, gates but excluding framed truss etc all as specified and as directed.
1.44
-
-
... More
S & F in repair Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, all as specified and as directed.
26
-
-
... More
Taking down chowkhats or frames n exc. 1.5 Sqm with shutters without taking off shutters from the frames all as specified and as directed.
60
-
-
... More
Taking down chowkhats or frames exc. 1.5 Sqm and n exc 4 Sqm with shutters without taking off shutters from the frames all as specified and as directed.
32
-
-
... More
S&F aluminium powder coated grill of make DG 104 (10mm thick) with DL 102 frame all as specified and as directed.
96
-
-
... More
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleats for fixing etc complete all as specified and as directed
920
-
-
... More
S&F power coated aluminium window and ventilator shutter fixed type without sash bars, aluminium section weighting 0.55 kg/rm including necessary jointing cleats rubber packing, anodised snap beading screws ets complete all as specified and as directed.
96
-
-
... More
M&L for plain glass 4 mm thick,ordinary quality and glazing exc. 0.5 Sqm in each pane all as specified and as directed.
96
-
-
... More
M&L for plain glass 5.5 mm thick,ordinary quality and glazing exc. 0.5 Sqm in each pane all as specified and as directed.
16
-
-
... More
S&F Aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture of 1.40mm and fixed stainless steel wire staples all as specified and as directed.
28
-
-
... More
M&L for making good jambs, forming jambs etc to openings for door and window opening including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete in cement mortar 1:6 all as specified and as directed.
64
-
-
... More
S&F solid PVC door frame of size 95mm x 50mm made out of 5mm prelaminated PVC sheet reinforced with MS square tube, fixed in position all as specified and as directed.
48
-
-
... More
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with prelaminated colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both side prelaminated sheet PVC sheets for top rail, lock rail & bottom rail panelling of plain gap insert for top rail & bottom rail panelling of prelaminated PVC sheet 10mm to be fitted in the MS frame selded/sealed to the stiles & rails (stiles and rails feathered at edge) with suitable PVC sheet beading and jointed together with solvent cement suppling & fixing in the frame at site and as per specification & drawing.
20
-
-
... More
M&L for preparing new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed.
8
-
-
... More
Taking down GI/PVC tubing & connections (internal water supply pipes) 20 mm bore and removing from the site all as specified and as directed.
80
-
-
... More
All as per item No 39, here in before, but 25 mm bore all as specified and as directed.
64
-
-
... More
M&L for CPVC pipes SDR 11 Class 1 laid in trenches/walls 20 mm dia all as specified and as directed.
80
-
-
... More
M&L for CPVC pipes SDR 11 Class 1 laid in trenches/walls 25 mm dia all as specified and as directed.
64
-
-
... More
S & F in repair bib taps cast copper alloy with crutch or butterfly handles screwed down for iron pipes of 15 mm bore all as specified and as directed.
16
-
-
... More
S &F in repairs 15 mm bore Stop valves cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes all as specified and as directed.
8
-
-
... More
S&F in repairs pillar tap standard of PTMT long body fancy type screwed down, screwed for CPVC pipes 15mm bore (15mm-120gm) all as specified and as directed.
8
-
-
... More
S & F in repair PVC connections, 450 mm long with brass CP check nuts suitable for connecting 15 mm dia pipes, superior quality, all as specified and as directed.
8
-
-
... More
S&F in repairs waste fittings brass chromium plated 32mm for glazed were basins and kitchen sink with long screwed shanks and fly nuts all as specified and as directed.
8
-
-
... More
Treating and finishing the sunken portion of WC area not exceeding 1.2 Sqm each by providing 10mm thick rendering in cement mortar 1:3 with and including water proofing compound and applying two coats of bitumen 85/25 @ 1.25 kg/sqm, providing necessary connection items suitable for WC, providing lime concrete and 1mm thick multiplus plastifelt over 20mm thick plain cement concrete 1:2:4 type B0 using 12.5 mm graded crushed trap stone aggregate complete all as specified and as directed.
5
-
-
... More
All as per item No 48 here in before,but for bath/lobby without any PVC connections/fitting, area exc 1.2 Sqm and n. exc 2 Sqm each all as specified and as directed.
5
-
-
... More
S & F rotational moulded polythene water storage tanks with (cylindrical vertical with closed top) hoisted and fixed in position all as specified 1000 ltr capacity including refixing of float valves 20/25mm all as specified and as directed.
4
-
-
... More
S&F gate valve PTMT, screwed down, high pressure with crutch or butterfly handle, screwed both ends for CPVC pipes 20mm bore all as specified and as directed.
4
-
-
... More
Supply only PVC low/high level flushing cistern, 10 Ltrs capacity including float valve, chain, PVC flush pipe all as specified and as directed.
4
-
-
... More
S&F in repair vitreous china wash hand basin, white , flat back, size 630X450mm including brackets all as specified and as directed.
4
-
-
... More
S & F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe including of fixing supply pipe to flushing cistern, trap and waste pipe all as specified and as directed.
4
-
-
... More
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in soft/disintegrated rock all as specified and as directed.
40
-
-
... More
M & L for 100 mm thick PCC 1:4:8 type D2 using 40mm graded stone aggregate as sub base all as specified and as directed.
40
-
-
... More
M&L for Sand filling under floors or in foundations including watering and consolidation all as specified and as directed.
4
-
-
... More
M&L for pre - cast cement concrete block masonry type C-5,with solid blocks built in cement mortar 1:6 all as specified and as directed.
2.4
-
-
... More
M & L for 60mm thick Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment all as specified and as directed.
40
-
-
... More
M & L for rendering 10mm thick on fair faces of brick work on concrete surfaces in cement mortar 1:6 be finished even and smooth without using extra cement all as specified and as directed.
16
-
-
... More
M & L for preparation of newly plastered surface and applying two coat of colour wash over a coat of white wash all as specified and as directed.
16
-
-
... More
S&F in repair vitreous china coloured water closet Europen type with and including jet spray/faucet including fixing with P trap all as specified and as directed.
4
-
-
... More
S&F Coloured non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match all as specified and as directed.
120
-
-
... More
M & L for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
48
-
-
... More
M&L for screed bed or bedding layer of mortar 15 mm thick cement plaster 1:6 for laying floor vitrified tiles all as specified and as directed.
48
-
-
... More
M&L for pre-painting galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified and as directed.
120
-
-
... More
S&F rolled mild steel section as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other plates confirming to Fe 410-W(grade-E-250) all as specified and as directed.
480
-
-
... More
M&L for cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 for sunshades, lintels etc and making good, cutting exceeding 20cm girth in stone or concrete block walls all as specified and as directed.
24
-
-
... More
All as per item No 68, here in before, but for cutting exceeding 10cm but not exceeding 20cm girth all as specified and as directed.
160
-
-
... More
M&L for providing cement concrete type B1, 1:2:4, using 20mm graded stone aggregate as in roof kerbs, covings rounded or chamfered on edges all as specified and as directed.
2.4
-
-
... More
S&F in repairs PVC (SWR) pipes single socketed 110mm dia in any length with rubber ring joints fixed to walls with proper stack clamps etc all as specified and as directed.
48
-
-
... More
S&F 600mm x 450mm looking mirror, bevelled edge, of selected quality glass, mounted on PTMT frame of overall size including mirror 600mm x600mm and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and as directed.
10
-
-
... More
S&F UPVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement all as specified and as directed.
8
-
-
... More
Demolition of brick or laterite stone masonry in cement mortar complete all as specified and as directed.
0.96
-
-
... More
M&L for rendering 15 mm thick in cement mortar 1:6 on concrete solid block wall internal surface finished even and smooth without using extra all as specified and as directed.
16
-
-
... More
M & L for Granite 20mm thick for outside entrance pillars (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite all as specified and as directed.
40
-
-
... More
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and as directed.
44
-
-
... More
S&F Nahani traps CL 75mm dia with grating including jointing to waste pipe fixed in cement concrete type B1 1:2:4 all as specified and as directed.
12
-
-
... More
S & F in repairs of PVC sheet wall panelling of thickness 5mm consisting of panel size 1220x2440 mm stuck on inner frame work of 50mm wide strips of 5mm thick pre lam PVC sheet. The PVC strips shall be dfixed to wall using 65mm lomgs MS screws through the groove in the strips by using PVC fastners etc complete all as specified and directed.
44
-
-
... More
S & F in repair curtain rails 19mm dia stainless steel with brackets stops rollers etc all as specified and as directed.Note: Size of bracket not less than 75mm long
80
-
-
... More
Chipping loose concrete and Exposing existing RCC columns, beams, slabs, lintels, pardis etc.including plaster beyond main reinforcement carefully by means of chisel and hammer or mechanically including necessary double scaffolding ,erecting horizontal platforms at working levels to collect the debris, propping with top and bottom runners as directed stacking the debris in the compound as directed and caring away the same outside the premises etc. complete all as specified and as directed.
206
-
-
... More
RELIEVING STRUCTURAL MEMBERS Relieving structural members such as column, beam and slabs of their superposed loads partially or fully by provision of adjustable steel props, frames etc. including providing necessary timber runners, bracing , jacking up arrangement complete all as specified and as directed. Note : Removing and redoing of brickwork, if required ,shall be paid separately
328
-
-
... More
Chipping of existing loose,damaged concrete from RCC members of all affected RCC Columns, Beams, Slabs and Chajjas on External and internal facades etc beyond main reinforcement.(if requried in the opinion of the Consultant),carefully with chisel and hammer, providing and applying ' Rusticide SS' Rust passivater or equivalent as specified in the Brand Names to existing reinforcemen bars including wire brushing of reinforcement, cleaning washing of concrete etc complete as directed. Providing and applying two coats of rust preventor slurry made out of " Polyalk Fixoprime" or equivalent as specified in the Brand Names and cement in proportion 1:1:5 to existing r/f bars as directed complete.Providing and applying bonding coat of slurry made out of "Polyalk EP" or equivalent as specified in the Brand Names and cement in proportion 1:1 to concrete and e/f substrates complete as directed .Providing and applying "Polyalk EP" or equivalent as specified in the Brand Names,Polymer modified cement mortar in Required proportion(1:5:15) to RCC members including hand packing,curing and making the surface rough for plastering complete all as specified and as directed.
648
-
-
... More
FILLING AND REINSTATING OF SEPARATION CRACKS : Opening the Separation cracks at the Juction of RCC and Masonry where ever directed and instructed into "V" Grooves 2" to 3" from the either side of the cracks by carefully marking the areas to be opened up using a cutting machine and skillfully Chiseling with a well sharpened chisel and hammer as directed including wire brushing and washing of concrete Substrata and masonry wall with water jet to the surfaces thus prepared to the entire satisfaction of the Consultant as instructed and directed.
240
-
-
... More
Moistening the cracks ,providing and applying primary/bonding coat of slurry made of "Polyalk EP" and cement(or equivalent as specified in the list of Brand names) in proportion 1:1 to surfaces prepared as instructed and directed. Filling the cracks /Grooves by Providing and applying "Polyalk EP" Polymer modified cement mortar (or equivalent as specified in the list of Brand names) in Proportion of 1:5:15 (Polyalk EP: Cement:Graded sand/quart/sand ) on the prepared surfaces and finishing it in the level with the existing plaster including hand packing curing and making the surface similar to the external plastering using wooden floats/punch etc. complete all as specified and directed.
240
-
-
... More
Drilling holes of required size upto 16mm Diameter and up to 50mm depth in concrete and cleaning the same complete all as specified and as directed.
240
-
-
... More
Providing and fixing 12mm diameter aluminium/PVC injection nipples and securing the same as directed & Providing and injecting cementitious grout using CEBEX-112 additive of 'Fosroc' at the rate of 225 grams per bag of cement and using suitable mechanical gun/pump including mixing etc complete all as specified and as directed.
240
-
-
... More
Providing & fixing epoxy dipped shear keys of 10mm dia and 4" to 6" length in columns before jacketing Micro concreting as per Consultants instructions and directions complete all as specified and as directed.
312
-
-
... More
Providing, cutting, bending and fixing Additional Reinforcement in position steel reinforcement of specified required sizes and shapes in the form or main rebars, stirrups & rings, distribution rebars etc.and tying them to shear connectors using GI Binding wire.The additional rebars should be coated with TWO coats including Anti Corrosive protective coating & dry sand to be sprinkles on second coat including tying with Annealed Binding wires, providing cover blocks of appropriate sizes etc complete as specified and instructed by the Consultants.
1088
-
-
... More
Providing and laying super fluid Microconcrete -Roffe crete repairs (or equivalent as specified in the list of Brand names) in beam bottoms, columns,slab etc including mixing with 5mm to 10mm size aggregates waterproof ply wood/steel plate shuttering,pouring,temping,Consolidating,curing etc complete as per Manufacture's specification and Consultants instructions. Note : The item shall be paid on actual consumption of Micro concrete.
17600
-
-
... More
Providing and laying in slabs,beams,pardise,RCC wall etc position of RCC M-25 design mix grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying and the cost of centering,shuttering form work,finishing and excluding reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete,improve workability without imparing strength and durability as per direction of Engineer-in charge.The Mix design as per particular specifications shall be got approved by Engineer -in charge before execution of the item. The rate shall include cost of all specified materials and operations at all levels and heights, including the cost of centering ,shuttering and form work excluding reinforcement which shall be paid under relevant item .Note:- Cement content considered in this item @ 300 kg/cum as per IS 456 table showing minimum cement content.No extra will be paid nor any amount will recovered on account of variation of cement in mix design as per specifications for controlled
10.4
-
-
... More
Glass fiber Wrapping system : Provision & laying applying Glass Fiber sheet wrap at structural members including surface preparation: Grinding/Moulding concrete substrate ,cleaning it with wire brush,removing oil,laitance if present,rounding sharp edges to min 25mm radius etc,complete.Profiling :Applying PRIMER on prepared substrate,filling holes and uneven surface with PUTTY etc, complete.Wrapping the Glass fibre wrap to voids etc.Repeat the same procedure for multiple layer with interval of 8 hours.Sand pasting:Applying saturant,rectify air voids if any ,paste the river sand on it to make surface rough to take any further finishes.(Mode of Measurement :Per Sq.m of fiber consume and not application and not application of surface area)
64
-
-
... More
Carefully Chiseling/Chipping out all existing loose decayed plaster of External Facades and Terrace area(In patch work)using plaster breaking machine and or well sharpened chisel & Hammers at proper angles carting away the Debris outside of bldg premises etc complete as directed by the Consultants ,providing and applying 20/25 mm thk sand faced plaster to concrete members-brick work etc of external wall facades using approved screened and Pre washed River sand including base coat of 13-15 mm thick in C.M.1:4 and curing the same for not less than three days and keeping the surface of base coat rough to receive the sand face treatment 6 to 8 mm thick of C:M 1:3 finishing the surface by taking out grains and curing for 7-10 days, providing and mixing approved waterproofing compound in required quantities in both the coats complete all as specified and as directed.
976
-
-
... More
Chipping out all existing loose and decayed internal plaster and redoing the same with 15mm thick,Cement plaster in cement mortar 1:4 finishing with 'Instant Neeru' of Elephant Brand or equivalent in the inside areas of staircase areas and over internal Structural Members of premises etc. complete all as specified and as directed.
800
-
-
... More
Removing and demolishing the existing waterproofing upto slab level of any thickness ,stacking the excavated debris on the ground floor,in the compound of the building carting away the same outside the MES premises complete all as specified and as directed.
1803.2
-
-
... More
M&L for Cement concrete type B-1,1:2:4 using 20mm graded stone aggregate 40mm thick in floors finishing the surfaces even & smooth without using extra cement complete all as specified and as directed.
1803.2
-
-
... More
M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric(wt.not less than 150 gms/sqm)land on primed surface by forced application complete all as specified and as directed.
1803.2
-
-
... More
M&L for cement concrete tiles 25cm x 25cmx 22mm thick machine pressed set jointed and pointed in neat cement slurry in floors and cut and polished over 20mm cement screed 1:4 complete all as specified and as directed.
1803.2
-
-
... More
Schedule 'A' Part II - (E/M Portion)
-
-
-
... More
Taking down aluminium/copper point wiring (light, fan, socket or power ) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc and making good the disturbed complete all as specified and as directed .
362
-
-
... More
Taking down submain wiring Aluminium/ copper of any size including earth continuity conductor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
900
-
-
... More
Taking down existing DB TPN/SPN any way of capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.
9
-
-
... More
M&L for point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed multistranded copper conductor single core cable conforming to IS 694 FRLS drawn through and including rigid PVC casing caping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sq mm PVC unsheathed copper conductor as earth conductor and connected to earth dolly , including provision MS boxes made out of 1.6 mm thick MS sheet factory painted rectangular as required with 3 mm thick plastic laminated sheet top cover /modular top cover for housing swtiches , sockets etc concealed on wall complete all as specified and directed for the following :-
-
-
-
... More
a) One light point controlled by one switch
166
-
-
... More
b) One fan/ exhaust fan point controlled by one switch and regulator
120
-
-
... More
c) One 3 pin socket, 5 Amps on the same board, with cables 1.5 sq. mm size
14
-
-
... More
d) One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size
48
-
-
... More
e) One light point controlled by two 2-way switches, with cables 1.5 sqmm.
2
-
-
... More
f) One call bell controlled by one push button with cables 1.5 sqmm
1
-
-
... More
M&L for point wiring complete with FRLS 1100 Volts grade, 2.5 Sqmm PVC insulated and unsheathed multistranded copper conductor single core cable conforming to IS 694 FRLS drawn through and including rigid PVC casing caping medium grade of size 25/20 mm, etc fixed on wall/ceilling including provision of 2.5 sq mm PVC unsheathed copper conductor as earth conductor and connected to earth dolly , including provision MS boxes made out of 1.6 mm thick MS sheet factory painted rectangular as required with 3 mm thick plastic laminated sheet top cover /modular top cover for housing swtiches , sockets etc concealed on wall complete all as specified and as directed
11
-
-
... More
S&F switch modular type single pole 6 Amps one way with one module all as specified and as directed
286
-
-
... More
S&F modular type switch two way 6 Amp 230 volt 50 HZ AC supply with one module all as specified and as directed
4
-
-
... More
S&F Switch socket combination 2 in 1, 3 pin, 6 Amp modular type with two module all as specified and as directed
62
-
-
... More
S&F Switch socket combination 5 in 1 pin 5 / 16A, modular type with three module all as specified and as directed
11
-
-
... More
S&F bell push 6 Amp modular type, 230 volt, 50 HZ ,AC supply with one module all as specified and as directed
1
-
-
... More
S&F Ding dong Bell, AC, 230 volts, single pole 50 HZ AC supply all as specified and as directed
1
-
-
... More
S&F ceiling rose three terminal 230 volt 50 HZ AC supply all as specified and as directed
286
-
-
... More
S & F in repairs for industrial socket with single pole and neutral enclosure with a two pin and earth plug and socket/top 240 V 50 Hz complete with one SP MCB 20 Amp complete all as specified and as directed.
8
-
-
... More
M & L for submain wiring with 1100volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC conduit 25 mm dia in Ivory/Grey colour medium grade etc fixed on concealed including provision of 01 run of 6.0 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 6.0 sqm including 01 run of PVC conduit shall be measured as one length complete all as specified and directed .
600
-
-
... More
M & L for submain wiring with 1100volt grade PVC insulated unsheathed multistranded 02 run of 04 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC conduit 25 mm dia in Ivory/Grey colour medium grade etc fixed on concealed including provision of 01 run of 4.0 sqmm PVC unsheathed copper conductor and connected to earth dolly complete all as specified and as directed. Note :- 02 run of 04 sqmm and 01 run of 4.0 sqm including 01 run of PVC conduit shall be measured as one length complete all as specified and directed .
300
-
-
... More
S&F MCB DB TPN double door 4 way 415 volts 50 Hz horizontal with IP-43 degree protection complete all as specified and as directed
1
-
-
... More
Supply and fix MCB DB, single pole and neutral with suitable Amps rated busbar double door 12 way 230 volt 50 HZ AC Supply complete all as specified and as directed.
6
-
-
... More
Supply and fix MCB DB, single pole and neutral with suitable Amps rated busbar double door 8 way 230 volt 50 HZ AC Supply complete all as specified and as directed.
2
-
-
... More
S&F MCB SP 06 to 32 Amp 230 volts,50Hz,Breaking Capacity 10 KA complete all as specified and as directed
72
-
-
... More
S&F in repair MCB TPN 'C' series 63 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and as directed
1
-
-
... More
S&F in repair MCB TPN 'C' series 40 Amp, 415 volts, 50 Hz, 10 KA complete all as specified and as directed
3
-
-
... More
M&L for RCCB Double pole, 30mA 25 Amps 230V 50Hz AC complete all as specified and as directed.
8
-
-
... More
S & F LED INTEGRATED BATTEN T5 tube light fitting type 1x18/ 20 watt indoor decorative aluminium extruded T5 LED Battens-integrated type complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
190
-
-
... More
S & F LED INTEGRATED BATTEN T5 tube light fitting type 1x 9/10 watt indoor decorative aluminium extruded T5 LED Battens-integrated type complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed
8
-
-
... More
S&F deluxe stepped type type electronic fan regulator deluxe flush 200 watt type on the phenolic laminated sheet complete all as specified and as directed
116
-
-
... More
M & L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized earth wire 4 mm dia by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 15mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion.
6
-
-
... More
Supply and fix electric Exhaust fan with louvers 230V single phase metallic body 5 star rated capacitor type -sweep size (mm) 300 connecting up including provision of necessary wall opening and connected cement works and cable from ceiling rose or connector to exhaust fan etc complete all as specified and as directed.
Note: Old exhaust Fan deposited in store
4
-
-
... More
Supply and fixing of wall mounted fan of sweep 400 mm complete all as specified and as directed
10
-
-
... More
Removing and refixing of ceiling fan of sweep 1200 mm from its installed location servicing the fan by cleaning ,greasing,oiling,painting with two coat of existing colour including replacement of worm out nut bolts , split pins and check nuts complete all as specified and as directed
56
-
-
... More
Supply and fixing of ceiling fan of sweep 1200 mm complete all as specified and as directed.
Note: Old ceiling Fan shall be deposited in store