Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 86,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670658_1Bid Award Id
ViewTender No
8637Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply & Fixing in replacement of high energy efficent constant current electronic driver suitable for 230v, 50hz, LED street light fitting 90-150 Watts LED luminaires complete all as specified and directed.
30
-
-
... More
S&F in replacement loop-in-loop out fuse junction (SMC) box of internal dimension 250 x 250 x 150 mm made out of FRP sheet and locking screw fitted with and incl 0.5 Amps MCB - 1 No, 20 Amps rated 4 way connectors for 3 phase and neutral incoming/ out going, mounted in the box, fixing on any type of poles including necessary clamps, suitable glands, Connector, lugs, GI nut and bolts complete all as specified and directed.
Make : Sintex/ Hensel/National
30
-
-
... More
All as per item No. 5 above but of size 140 x 140 x 95 mm
10
-
-
... More
M&L for replacement of UNSV GI bracket made out of GI pipe 40 mm bore light grade bent to required shape of 1.20 mtr long and fixing to pole/wall with suitable size of nut, bolts and clamps made out of MS Flat 40 x 5 mm and fixing of 2.50 m long copper conductor cable multistranded of 2.5 Sqmm PVC cable from overhead line to fitting connection box all as specified and directed.
10
-
-
... More
All as per item No. 7 above but GI pipe of 32 mm dia
15
-
-
... More
Material and labour for replacement of existing unsv street light fittings with LED street light fitting 90 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual peanut LED lenses and Driver shall be IP-67 for water protection, including surge protection device 5 KV including making connections with PVC insulated and sheathed three core multi stranded aluminium conductor cable of size 1.5 Sqmm complete all as specified and directed.
60
-
-
... More
All as per item No. 9 above but 120 watt street light
20
-
-
... More
M&L for replacement of existing unsv flood light fittings with LED flood light fitting 120 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 KV and Driver shall be IP-67 for water protection, including making connections with PVC insulated and sheathed three core multi stranded alumn conductor cable of size 2.5 Sqmm complete all as specified and directed.
3
-
-
... More
S&F PVC sheathed 1100 V grade three core multistranded stranded copper conductor of size 2.5 sqmm including PVC conduit pipe 20 mm of size complete all as specified.
270
-
-
... More
Supply and fix high density polyethylene pipes of pressure rating 6 kgf/cm2 (HDPE) of size 20 mm bore having pressure rating 6kgf/sqcm complete all as specified and directed. (for street light cable protection from SMC box to LED fitting)
120
-
-
... More
Supply and fix Prestressed concrete pole, 9.0 metres long, 102 mm x 172 mm at top and 1022 mm x 279 mm at bottom, class 10 incl dismantling old UNSV pole of any type complete all as specified and directed
2
-
-
... More
Taking down existing MS articles and S&F new Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed including applying of two coats of aluminium paint over a coat of red oxide primer complete all as directed.
1.5
-
-
... More
S&L in replacement XLPE LT UG cable PVC insulated, bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sq mm 4 core laid in trenches or fixed on wall/floor/poles complete all as specified and directed.
100
-
-
... More
All as per item No. 16 above but 35 Sqmm 3.5 core cable
400
-
-
... More
All as per item No. 16 above but 50 Sq mm 3.5 core cable
250
-
-
... More
All as per item No. 16 above but 95 Sq mm 3.5 core cable
300
-
-
... More
All as per item No. 16 above but 120 Sq mm 3.5 core cable
200
-
-
... More
All as per item No. 16 above but 185 Sq mm 3.5 core cable
310
-
-
... More
All as per item No. 16 above but 240 Sq mm 3.5 core cable
320
-
-
... More
All as per item No. 16 above but 400 Sq mm 3.5 core cable
160
-
-
... More
All as per item No. 16 above but 16 Sqmm 4 core cable
100
-
-
... More
All as per item No. 16 above but 10 Sqmm 4 core cable
350
-
-
... More
Excavation in trenches in hard/dense soil, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
124
-
-
... More
Excavation in trenches in soft/disintegrated rocks, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, laying of pipe line/ cable etc. n exc 10 sqm on plan and getting out complete all as specified and as directed.
149
-
-
... More
Returning filling in including spreading watering and well raming in layer excedding 25 cm each in any type of soil/rock complete all as specified and directed.
257
-
-
... More
Removing excavated soil/rock of any type to a distance not exceeding 50 m and deposited where directed at a level not exceeding 1.5m above the starting point complete all as directed.
18
-
-
... More
Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 38 mm inner dia and 50 mm outer dia complete all as directed.
400
-
-
... More
Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 50 mm inner dia and 63 mm outer dia complete all as directed.
1000
-
-
... More
Supply & laying double walled corrugated (DWC) HDPE full rounded pipe conforming to IS 16205 Pt-24 of approved colour complete with fittings for cable protection of size 75 mm inner dia and 90 mm outer dia complete all as directed.
500
-
-
... More
S&F in repair solar street light standalone type of 30W with IP 66 Protection,LED Luminous Efficacy 120Lm/W,Color Temperature 6000-6500 K,Lithium Battery, 3.2V 18AH,Charging Time 6-8 Hrs, Backup Time 8-12 Hrs, Solar Panel 10V/20W, MONOCRYSTALLINE, Rated Life 30,000 Hours complete all as specified and directed.
Make luker/Bajaj/Crompton/Havells
3
-
-
... More
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron Wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 15 mm GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.
Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and 4mm dia earh lead wire upto 7.5 M.
2
-
-
... More
M&L for earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25 Mts deep below ground level with top edge of the plate not less than 1.50 Mtrs below ground level connected to glavanised iron strip 25 x 4 mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl GI tubing medium grade and necessary fitting for protection of GI wire incl laying of charcoal dust and common salt in alternate layer, PCC Pit (1:3:6) type C-1 using 20 mm graded stone aggregate, RCC cover 40mm thick (1:2:4) type B-0 using 12.5 mm graded stone aggregate reinforced with 6 mm dia round bar @ 75 mm C/C both ways with MS handle 8 mm dia, plastering 15 mm thick CM (1:6) externally upto 150mm below ground level, GI funnel with 20mm dia medium grade GI pipe for watering and wire mesh incl. excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate No 3 of SSR Part (2009) and connected to earth test point incl testing complete all as specified an directed.
Note:- The unit rate includes the cost of GI pipe medium grade for protection of earth wire and earth strip upto 7.5 M.
6
-
-
... More
Supply and fixing in replacement of existing old un-serviceable Earth continuity conductor of size 25 x 4 mm GI strip fixed to wall and batton or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other situation for loop earthing etc. complete all as specified and directed.
150
-
-
... More
Material and labour for replacement of GI tubing light grade 50 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
35
-
-
... More
Material and labour for replacement of GI tubing light grade 80 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
38
-
-
... More
Material and labour for replacement of GI tubing light grade 100 mm bore for passing through cables laid under the floor, along the wall or along the pole complete all as specified and directed .
12
-
-
... More
M& L for disconnecting electrical connections of faulty bollard lights of 9/12/15 watts and opening it to replace the burnt UNSV driver to make it functional complete all as specified and directed Note: The rate quoted rate deemed to be inclusive of cost of driver 9-15 watts.
25
-
-
... More
M&L for PCC 1:3:6 type C-2 ( using 40mm graded stone aggregate) as in foundation, filling and mass concrete including necessary formwork complete all as specified and directed.
0.5
-
-
... More
M&L for PCC 1:3:6 Type C-1 (using 20 mm graded stone aggregate) as in coping/pedestal of poles including necessary form work and finishing the surface with rendering 5 mm thick in cement mortar 1:4 finished even and smooth withot using extra cement complete all as specified and directed.
1
-
-
... More
S&F in replacement aluminium land scape luminaries (LED bollard) of 9/12 watts, 230 volts, 50 Hz with IP 65 protection with robust design and efficient light distribution including excavation and PCC 1:3:6 type C-1 using 20 mm graded stone aggregate for foundation complete all as specified and directed complete all as specified and directed.
9
-
-
... More
S&F in replacement heritage type post top lantern with warm light 40 Watts, 230 volts, 50 Hz with IP65 with dia cast aluminium spigot, powder coated aluminium reflector with decorative clear acrylic diffuser, all accessories and prewired complete all as specified and directed.
4
-
-
... More
S&F in replacement of existing unsv cable straight through joints with straight through joints (heat shrinkable) any type suitable for XLPE 1100 Volts aluminium conductor cable of size 35to 50 Sqmm 3.5 core and testing after jointing complete all as directed. Note:- Rate quoted including necessary excavation, returning filling, removal etc for taking out loop/ cutting of burnt cable for required length for making end joint.
3
-
-
... More
All as per item No. 45 but for cable size 70-120 Sqmm 3.5 core
3
-
-
... More
All as per item No. 45 but for cable size 185-240 Sqmm 3.5 core
3
-
-
... More
Taking down existing old unsv LT panel board with all accessories and Supply, installing, erecting, commissioning and testing new factory made LT panel board cubical out door type of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3 mm thick CRCA sheet powder coated with front openable with suitable cable chamber and front side double shutters with locking arrangement, panel base of angle iron 50x50x6 mm upto 60 cm height for ground level, 433 volts, 3 phase, 4 wire system. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar 400 Amp. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation 0.45 mtr above floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following :-
INCOMING MCCB
a) 250 Amp 4 pole MCCB 25 KA breaking capacity with adjustable thermal magnetic setting with earth fault protection and rotary handle Ics= 100% Icu-01 Nos. OUTGOING MCCB
a) 125 Amp 4 pole MCCB 25KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 03 Nos. b) 63 Amp 4 pole MCCB 25KA breaking capacity with adjustable thermal magnetic setting with rotary handle Ics= 100% Icu - 02 Nos. b) 63 Amp SPN MCB - 06 No. c) Space for spare MCCB/MCB
Metering:
a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 No.
c) LED Indicating lamps RYB set of three -01 Sets
The manufacture shall submit a copy of TESTREPORT of CPRI approved.
1
-
-
... More
S&F in replacement MCCB 125 Amps 415 volts, 50 Hz, 3 pole, 16 KA breaking capacity with thermal magnetic setting including providing suitable size aluminium lugs, speders complete all as specified and directed.
2
-
-
... More
All as per item No. 49 but MCCB 160 Amps, 4 pole, 36 KA
2
-
-
... More
All as per item No. 49 but MCCB 250 Amps, 3 pole, 36 KA
1
-
-
... More
All as per item No. 49 but MCCB 250 Amps, 4 pole, 36 KA
3
-
-
... More
All as per item No. 49 but MCCB 400 Amps, 3 pole, 36 KA
2
-
-
... More
Supply and fixing in replacement of aluminium conductor, steel reinforced (ACSR) of any size/description on LT poles/lines (Approx. 9 mtr) including Clamps, stringing, tightening, binding to insulators with aluminium wire making and connecting jumpers, connections etc including connecting, commissioning and testing complete all as specified & directed .
1
-
-
... More
S&F in replacement of sheet metal enclosure VTPN DB's IP 43-IK 09 double door 415 V, suitable for 4 ploe MCCB 8 way with 250A copper busbar complete all as specified and directed.
3
-
-
... More
S&F in replacement sheet metal enclosure MCB distribution board, double door with IP-43 protection SPN, 240 Volts, 8 way, including suitable size copper bus bar and metal door, epoxy powder coated, factory made complete without MCB and with enclosure blank plates for unused way fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces complete all as specified and directed.
3
-
-
... More
All as per item No. 56 but MCB distribution board, 16 way
2
-
-
... More
S&F in replacement MCB single pole 240 volts, 'C' curve of rating from 16 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
60
-
-
... More
S&F in replacement MCB single pole 240 volts, 'C' curve of rating 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
14
-
-
... More
S&F in replacement MCB single pole 240 volts, 'C' curve of rating 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
10
-
-
... More
S&F in replacement MCB single pole and neutral 240 volts, 'C' curve of rating 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
10
-
-
... More
S&F in replacement MCB tripple pole 240 volts, 'C' curve of rating 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
10
-
-
... More
S&F in replacement MCB tripple pole 240 volts, 'C' curve of rating 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
10
-
-
... More
S&F in replacement MCB tripple pole and neutral 240 volts, 'C' curve of rating 40 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
11
-
-
... More
S&F in replacement MCB tripple pole and neutral 240 volts, 'C' curve of rating 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
10
-
-
... More
S&F in replacement MCB tripple pole and neutral 240 volts, 'C' curve of rating 100 amps, with rupturing capacity 10 KA, including providing thimble for out going cables complete all as specified and directed.
7
-
-
... More
S&F in replacement Heavy gang operated triple pole mechanically operated air break on load disconnecting switch each pole consist of galvanised iron base HT 11KV with polymer insulators per phase non ferrous knife and spring loaded contact GI pipe of adequate length for operation from ground level and operating handle complete in both OFF and ON position capacity 400 Amps complete all as specified & directed. Make: National Power/Jaipuria/ABB/Oblum
1
-
-
... More
S&F in replacement 11 KV Heavy Drop Out Fuse complete in each pole consist of galvanised iron base HT 11KV with polymer insulators complete all as specified and directed. Make: National Power/Jaipuria/ABB/Oblum
2
-
-
... More
S&F in replacement lightening arrestor HT 11000 KV pole mounting with polymeric insulator complete with all fittings transmission class nominal discharge current upto 65 KA complete all as specified and directed.
3
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements