Military Engineer Services Tender

View complete overview of Goa MES Tender

Military Engineer Services - MES Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date21 Sep 2023
Closing Date19 Oct 2023
Tender Amount₹ 35,20,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturer's recommendations to sustain back pressure with rain cap. (o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o 30 gauge for the entire length of exhaust pipe. (p) First fill of oil, coolant and diesel during commissioning and 12 hours testing. (q) Interconnecting copper cabling of adequate capacity batteries control. (r ) Fuel pipe class STIC 1" /1.5" /2" dia - 01 lot (s) Self starter 12 volts DC. (t) Electric operated electronic governor. (u) Fuel injection pump.

-

-

-

... More
(v) Electronic instrument panel, complete with all accessories as per manufacturer's specifications displaying the following:- (i) 12 V Battery (ii) Water temperature. (iii) lubricating oil pressure. (iv) Engine speed -1500Rpm (v) Engine hours (vi) Frequency. (vii) Voltage. (w) Safety control (Trip and indication). (i) High water temperature (ii) Low lube oil temperature (iii) Overspeed stop

-

-

-

... More
(x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturer's design alonwith AVM pads. (y) Battery:-24 volts(02x12vBattery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron). (z) Battery charger for 24 V(02 X 12 V battery) (aa) Fuel tank: 10 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.

-

-

-

... More
(c) Alternator: Suitable rated 200 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushles, screen protected, drip proof , insulation class-H, IP -23, voltage regulation grade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)

-

-

-

... More
(d) Acoustic Enclosure:- M & L for acoustic enclosure for the above 30 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board and size 3490 x 1340 x 1885mm and manufacturer's specification and comprising of following from authorised GOEMs of Gen Set manufacturer's specified :-

-

-

-

... More
(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum). (ii) Outer body : 1.6mm thick CRCA (iii) Door : 1.6mm thick CRCA (iv) Base frame : ISMC 300 (v) Inside illumination : 1 No.- 1 x 18 watt LED fitting

-

-

-

... More
(e) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted outoor type, IP-52, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following:

-

-

-

... More
(f) AMF control circuit with 4 pole MCCB 400 Amps - 2 nos, with ultimate breaking capacity Icu-36 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.

-

-

-

... More
(g) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No. (iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets. (iv) Bottom gland plate for incoming and outgoing cables. (v) Circuit diagram plate. (h)EMISSION CONTROL DEVICES PARAMETERS:- (i) Emission Limits : NOx+HC less than 4.0 (g/KW-Hr) CO less than 3.5 PM 2.5 less than 0.2 (ii) smoke limit (light : less than 0.7 Absorption coefficient) (iii) Purification : No filter, No solvents, Technology No Chemicals (iv) Polluted Captured : PM 2.5/PM 10 (v) Electrical : 220 V DC consumption (vi) Back pressure : N adverse impact on engine

-

-

-

... More
(vii) Product life : 10 years (viii) Material : Mild steel (ix) Reported PM : 80% -90%(ARAI and Reduction other NABL accredited labs) (x) By Product : Soot Particles (xi) Disposal : No burning or dumping of captured particles. (xii) Collection of : Once in Two months captured Particles (xiii) Two Nos of industrial socket 16 A for emission control device rate and foundation if necessary is included in this item.

-

-

-

... More
(j) Civil works:- All civil works related to foundation, installation of panel and equipment & depth of foundation shall be minimum 300mm with ant vibration pads, or as recommended by manufacturers. Cable from DG set to AMF panel, AMF panel to main panel will be measured under relevant schedule. Note:-The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipments like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department. DG Set design should be as per CPCB Norms-IV with retrofit emission control device.

-

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below the ground level with top edge of the plate n. less than 1.5 m below ground level connected to GI Strip 32 x 6 mm by means of bolts ,nuts ,checks nuts and washers of galvanized steel including necessary earth work and excavation in any strata and PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, chamber and RCC cover and medium grade GI pipe 40 mm dia upto 7.5 m long for protection of GI strip and water funnel and wire mesh with GI pipe medium grade 20 mm dia etc complete all as per electrical plate No. 3 of SSR-2009 Part-I and as directed including connections and testing on completion all as specified and as directed. Note : GI earth strip upto 7.5 RM is included in the unit rate quoted.

6

-

-

... More
Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 100 Amps capacity of bus bar,outdoor cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, Lugs for MCCBs, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings (DG Panel)

1

-

-

... More
INCOMING:-

-

-

-

... More
(a) MCCB with microprocessor magnitic release, 4 pole, 400 AMPS, 50 Hz, 415 Volt, 36 KA - 1 No (Incoming)

-

-

-

... More
(b) TPN Bus bar 650 Amps - 1 set

-

-

-

... More
OUTGOINGS:-

-

-

-

... More
(a) MCCB with microprocessor magnitic release, 4 pole, 400 AMPS, 50 Hz, 415 Volt, 36 KA - 1 No (Outcoming)

-

-

-

... More
(b) Astronomical, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T 1 no

-

-

-

... More
(c )Power contactor , 2 pole rating not less than 40 A with 230 coil make L&T/SEIMENS - 1 no.

-

-

-

... More
(d)Digital Voltmeter 0 - 500 volt of size 96 x 96 mm square with selector switch -01 Nos.

-

-

-

... More
(e) Digital Ammeter 0 - 1200 A of size 96 x 96 mm square with CT & selector switch-01 No.

-

-

-

... More
(f) Indicator Lamp LED type (R-Y-B) with holder-01 set of three.

-

-

-

... More
S& F XLPE insulated armoured and PVC sheathed heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size 3.5 X 240 Sqmm all specified and directed by Eng-in-charge. Note- Rate is inclusive of cable gland & cable lugs

200

-

-

... More
Supply and fix cable route indicator made of round CI disc embossed LT Cable, of size 16cm dia 6mm thick duly revited with angle of size 50x50x4mm and 60cm long including PCC 1:2:4 B2 using 20mm aggregate 15cm x 15cm x 15cm for grouting the same complete all as specified.

10

-

-

... More
Supply and fix double wall corrugated, High Density Polymer Ethyl pipe for layinng of Electric cable of size 140 mm outer dia and 125 mm inner dia with IS : 14930 (Part 2) : 2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as speicified and directed by Engineer-in-Charge.. Make - Dura line/Tijaria/TELEREX. (For cable )

200

-

-

... More
Supply and fix change over switch for 200 KVA Dg set , 3 phase , 4 pole 415 V all as specified and directed by Engr-in-charge

1

-

-

... More
Excavating in trenches n exc 1.5 m wide and n.exc 1.5 m in depth, for Foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables, poles & stay etc. n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft disintegrated rock/soil complete all as specified and as directed

62

-

-

... More
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25 cm deep as in soft disintegrated rock/soil complete all as specified and as directed

39

-

-

... More
Removal of excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point in rock complete all as specified and as directed

23

-

-

... More
S&F mild steel rolled section as in main and cross beams hips and jack rafters perlins where connected to comman rafters including cutting, welding etc complete all as specified and directed (Confirming to Fe-410, W (Gde-E-250) complete all as specified and as directed

900

-

-

... More
M&L for pre-painted galvalume aluminium zinc coating GI based coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strenght of 550 Mps as in roof covering/cladding to wall, fixed with self traping screws as specified complete all as specified and as directed

50

-

-

... More
All as per item No 14 here-in-before but plain sheet as in ridge complete all as specified and as directed

5

-

-

... More
M&L for two coats of syntehtic enamel paint over a coat of red oxide including preparation of new steel surfaces over 10 cm width or girth complete all as specified and as directed.

26

-

-

... More
M&L for cement concrete type C-2, 1:3:6 (40 mm graded aggregate) as in foundation complete all as specified and as directed.

5

-

-

... More
Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.

43

-

-

... More
M & L for precast cement concrete block masonry with solid block exc 10 cm in width and setting in CM (1:6) 1:3:6 type C-1 using 20mm graded stone aggregate complete all as specified and as directed.

10

-

-

... More
M&L for 15 mm thick plastering on brick/concrete surfaces in cement mortar 1:4 using water proofing compound and finished even and smooth without using extra cement complete all as specified and as directed Note: Water proofing compound shall be not measured & not paid separately.

40

-

-

... More
M&L for preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed.

40

-

-

... More
M& L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection or similar places surfaces finished even and fair without using extra cement complete all as specified and as directed

9

-

-

... More
M & L for Cement concrete type B-1, 1:2:4 (using 20 mm graded aggregate ) as in coping\ complete all as specified and as directed.

0.18

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.