Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684755_1Tender No
85865/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Disconnecting, opening of VCB of any description and any make of rating 11 KV 400/800 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and its testing complete all a specified and directed. Note: (i) Replacement of unserviceable parts shall be measured and paid for separately under appropriate item of Sch 'A' item no 5 to 19 as supply only but fixing charges of the parts replaced /repaired is deemed to be included in these item. (ii) Servicing shall be got carried out by the authorised rep of the VCB manufacturer and the service engineer will submit a service report for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
8
-
-
Supply only Vacuum circuit breaker main mechanism assembly complete with all accessories all as specified and as directed.
1
-
-
Supply only Vacuum Interrupter for indoor VCB
1
-
-
Supply only Isolating contact assembly 400/800 Amps
2
-
-
Supply only Tripping Coil assembly 30 Volts DC
2
-
-
Supply only Close Coil assembly 30 Volts DC
2
-
-
Supply only Motor & Gear assembly 110V AC and 220 AC
1
-
-
Supply only TNC switch for 11 KV VCB Panel
2
-
-
Supply only Connector strip 16 way
2
-
-
Supply only Spout Incoming side
2
-
-
Supply only Spout Outgoing side
2
-
-
Supply only Digital type power factor indicator meter
2
-
-
Supply only Digital type Ammeter/voltmeter
2
-
-
Supply only Earth fault and overload relay of suitable as per existing
2
-
-
Supply only Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
15
-
-
Supply in repairs including installation, testing and commissioning of Micro processor base relay (02 O/C + 01 EF) for 11 KV VCB panel , rating 5 Amps, Auxiliary supply 20-110 Volt DC complete all as specified and as directed.
Note:-
(i) Necessary addition/ alteration to existing VCB front panel such as cutting/welding of front size of panel board/position if required including necessary modification of wiring shall be carried out at site by the contractor without any extra cost.
(ii) The digital relay shall have following protections (a) Phase over current protection (b) earth fault protection (c) Over voltage (d) Breaker failure indication (e) Auxiliary power supply 24-110 V DC
1
-
-
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commissioning and testing of cast resin type 11KV current transformer having ratio 100+50/5+5A as per IS: 2705 having protection core class 5P10, burden of 15VA and metering core class CL1.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second all as specified and directed.
1
-
-
Disconnecting and taking down unserviceable voltage transformer of any description and in any position and supply, installation, commisioning and testing for 11KV single phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level 35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 complete all as specified and directed.
1
-
-
Supply in repairs including install ,testing and commissioning of Power pack unit input voltage 180-250 Voltage and out put voltage 24 Volt DC having 4-digit degital Volt & Ampere meter, High resolution D/A, A/D converter , Digital interface as standard function etc. complete all as specified and as directed including taking out unserviceable battery bank unit.
4
-
-
Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for laying & removing of cable any sizes and getting out in hard/dense soil all as specified.
52
-
-
Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for laying & removing of cable any sizes and getting out in hard/disintegrated rock all as specified.
106
-
-
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata
110
-
-
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point
48
-
-
Supply & Laying of dry river sand in trenches for cable protection all as directed.
Note : Punned thickness only will be measured & Paid
28.25
-
-
Supply and lay un-reinforced precast concrete cable covers, class HV , type- I with peak, size 300mm x 180mm x 40mm, all as specified and as directed.
1000
-
-
Supply & lay in trench/on wall in repairs GI tubing light grade 100 mm dia for road crossing and cable protection complete all as specified and as directed.
18
-
-
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation complete all as specified and as directed.
2
-
-
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole coping complete all as specified and as directed.
1.5
-
-
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in substation yard for laying all as directed and specified.
6
-
-
Supply & Lay , testing and commissioning XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 120 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete all as specified and as directed.
190
-
-
Taking out old serviceable ACB of capacity 400 to 1200 amps 415 volts AC 50 HZ at various sub station and carry out necessary servicing , greasing to fixed and movable parts , cleaning complete internally and testing after reinstallation.(Note:- Any demage occures during servicing will be borne by the contractor ).
4
-
-
Supply and fix charging motor 110V AC/DC, 220V AC/DC of suitable size for ACB of capacity 400 to 1200 Amps complete all as specified and as directed.
2
-
-
Dismantling old stay assembly incuding connecting items and M&L new stay assembly complete comprising of stay clamp , stay wire , stay insulator , stay grip , thimble , bow , stay rod 20 mm dia and stay plate etc as shown in electrical plate No -01 ( loop insulators , stay clamps , excavations and earth work shall be measured and paid seperately under respective items) .
1
-
-
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick burried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt mixed with 10% paddy field earth, PCC pit chamber in PCC 1:3:6 type C-1 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
2
-
-
M & L for Earthing complete with GI earth plate, electrode,600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials.
3
-
-
Supply& Fix in repairs including installation of 11 KV outdoor type gang operated air break switch triple pole machanically operated mounted on insulator and steel frame, with operating mechanism worked from ground level for current rating upto 200 amps complete all as specified and as directed. (Note:-cost of GOD includes cost of GI Pipe required for operation)
2
-
-
Repairing / Servicing the air break isolating switch 11 KV 200 Amps by replacing the defective major spares including provn of worn out bolts nuts etc, applying petroleum jelly on moving/ fixed contacts all as specified and as directed.
Note :- Major spare shall be measured & paid separately under relevant items of item No. 41.00
20
-
-
Supply only Air break switch spares
-
-
-
(a) Male contact/moving Contact Blade
8
-
-
(b) Female contact/Fix Contact Jaw
8
-
-
(c) Tinned copper Flexible jumper 200A
8
-
-
(d) MS jumper carrier
8
-
-
(e) Back Connector plate
5
-
-
(f) Petroleum Jelly
4
-
-
S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes as in repairs :-
-
-
-
(a) 80 mm dia
10
-
-
Supply and fix cable jointing kit for 11 KV(Earthed) grade cable straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AI conductor cable of size 50 sqmm to 95 sqmm complete all as specified and as directed.
2
-
-
All as per item no 43.00 here in before but of Size 120 to 185 sqmm.
2
-
-
Supply and fix cable jointing kit for 11 KV(Earthed) grade cable outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured AI conductor cable of size 120 sqmm to 185 sqmm complete all as specified and as directed.
2
-
-
All as per item no 45.00 here in before but of Size 50 to 95 sqmm.
2
-
-
Supply and fix cable jointing kit for 11 KV(Earthed) grade cable indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 .sqmm to 185 sqmm complete all as specified and as directed.
2
-
-
All as per item no 47.00 here in before but of Size 50 to 95 sqmm.
1
-
-
Supplying and laying synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m, complete all as specified and as directed.
4
-
-
Cutting and trimming of branches n.exc 50 mm dia in size obstructing lumination of street light and touching line complete all as specified and as directed.
30
-
-
Cleaning around any E/M installations/ pole structures including removing all grass and other vegetations with roots complete all as directed and removing the rubbish to a distance not exceeding 50 mtr and depositing where directed.
800
-
-
M & L for cleaning and preparation of steel surfaces of existing dull painting of transformer outdoor type including radiators, cooling ducts, vent pipes, condensor etc and applying two coats of synthetic enamelled paint (heat resistant type) according to to IS colour code by spray machine including writing MES /SM No. in capital letters of suitable size on body for capacity upto 250KVA transformer outdoor/indoor complete all as specified and as directed
6
-
-
All as per item No: 52.00 but capacity above 315 KVA and upto1000 KVA.
7
-
-
M & L Superior quality blue colour silica jel for breather unit and fill up the oil, to maintain the exact value grade for transformer of capacity upto 500 KVA, including taking down unserviceable complete as specified.
10
-
-
All as per item No: 54.00 but capacity above 600 KVA and upto 1000 KVA.
2
-
-
Supply and fix in repairs breather unit of transparent PVC Material including its replacement for transformer of capacity upto 500 KVA.
1
-
-
All as per item No: 56.00 but capacity above 500 KVA and upto 1000 KVA.
1
-
-
S&F in repairs HV bushing with insulator, studs nut & washers suitable for 11 KV/433V HV side of transformer 100 KVA to 150 KVA
1
-
-
All as per item No 58.00 above but 200 KVA to 250 KVA Transformer
1
-
-
All as per item No 58.00 above but 315 KVA to 400 KVA Transformer
2
-
-
All as per item No 58.00 above but 500 KVA to 630 KVA Transformer
2
-
-
All as per item No 58.00 above but 750 KVA to1000 KVA Transformer
1
-
-
S&F in repairs LV bushing with insulator , studs nut & washers suitable for11 KV/433V LV side of transformer of Capacity 100KVA to 150 KVA
1
-
-
All as per item No 63.00 above but 200 KVA to 250 KVA Transformer
1
-
-
All as per item No 63.00 above but 315 to 400 KVA Transformer
2
-
-
All as per item No 63.00 above but 500KVA to 630 KVA Transformer
2
-
-
All as per item No 63.00 above but 750KVA to1000 KVA Transformer
1
-
-
Servicing and repairing/ carrying out maintenance of 11KV/433V transformer including the following works upto 250 KVA capacity
(a) Removing from platform and disconnecting electrical connection from HT and LT side including transporting the transformer to work shop.
(b) Dismantling the transformer, drain out transformer oil, lift the cover,coil assembly keep up the assembly in oven upto the preparation of inside chambers by cleaning inside, scraping complete all around old parts of the transformer.
(c) M & L for two coats of oil resistance painting internal (inside transformer) over a coat of red oxide primer.
(d) Cleaning the core iron sheet laminations asssembly by oil complete,removing the carbon sediments, dust in the coil and core gently without making any damage to coil and core.
2
-
-
(e) Re-assembling all dismantled parts including provision of new gasket ,nut,bolts,refilling with transformer oil and transporting back to original location including elecric conection testing and commissioning complete.
(f) Necessary plate work incuding welding for preventing oil leakage if any.
Note :-
i) Oil filtration,supply of new oil will be measured separately.
(ii) All petty parts including nut, bolts, gasket minor weldings are deemed to be included the rate quoted (iii) The rate for transport and lifting of transformer by crane should be deemed to be included in the rate quoted.
-
-
-
All as per item No 68 above but 315 to 500 KVA Transformer
1
-
-
All as per item No 68 above but 630 to 1000 KVA Transformer
1
-
-
M & L for rewinding of transformer,including dismantling,drain out transformer oil and removing the core coil assembly from transformer remove the weak /unserviceable HT coil assembly rewinding with correct gauge super enamelled copper wire including drying,baking etc complete and remove the secondary coil assembly remove the insulation rewind with fresh coil and re-insulated. Assembling the primary and secondary coil in core, re-assembling the transformer complete refill with transformer oil, install, test and commissioning complete of following capacity all as specified and as directed.
-
-
-
(a) Transformer upto 250 KVA Capacity
1
-
-
(b) Transformer 315 KVA to 500 KVA Capacity
1
-
-
(c) Transformer 630 KVA to 1000 KVA Capacity
1
-
-
All as per item No. 70.00 here in before, but for 430 V LT side limbs for following capacities :-
-
-
-
(a) Transformer upto 250 KVA Capacity
1
-
-
(b) Transformer 315 KVA to 500 KVA Capacity
1
-
-
(c) Transformer 630 KVA to 1000 KVA Capacity
1
-
-
Notes for Item Sl Nos. 70 & 71 :
(i) Additional oil required for top up of transformer after filteration shall be measured and paid for separately.
(ii) Rewinding of limb shall be carried out only after the inspection of Transformer by the Departmental authority at Authorized maintenance work shop.
(iii) Cost for transportation and lifting of Transformer shall be measured and paid separately.
-
-
-
M & L for Transportation and lifting of Transformer 11KV/433V of capacity upto 500 KVA including loading and unloading by suitable capacity crane to workshop for repair as per SI Item Nos 70&71 above in a load carrier vehicle from Electrical installations at INS Hansa area to workshop and returning back to site at its existing installation place all as specified and as directed.
2
-
-
All as per item no 73.00 here in before but for transformer 11KV/433 V of capacity above 500 KVA to upto 1000 KVA.
1
-
-
S & F DO fuse elements Rating 11 KV capacity 05 Amps.
10
-
-
S & F DO fuse elements Rating 11 KV capacity 10 Amps.
30
-
-
S & F DO fuse elements Rating 11 KV capacity 20 Amps.
40
-
-
S & F DO fuse elements Rating 11 KV capacity 30 Amps.
40
-
-
S & F D.O fuse element Rating 11 KV capacity 40 Amps.
30
-
-
S & F D.O fuse element Rating 11 KV capacity 50 Amps.
20
-
-
M & L for preparation of old cement coated surface, cleaning the surface of the RCC Pole (HT) above the ground level including coping area with 2 coats of ACC exterior emulsion paint over a coat of cement primer after preparation of surface and all as specified and as directed.
5
-
-
M & L for Painting of 2 pole structure including preparation of old cement coated surface,angles,cross arms & painting of RCC poles with two coats of ACC exterier emulsion paint over a coat of Cement primer and painting of angle, cross arms,and connecting accesories with one coat of red oxide primer and two coats of aluminium paints all as specified and as directed.
2
-
-
All as per item no 82 here in before but for 4 pole structure
1
-
-
All as per item no 82 here in before but for 6 pole structure as required.
1
-
-
All as per item no 82 here in before but for 8 pole structure as required.
1
-
-
M&L for polymer Post / disc / pin insulator of 11 KV capacity carefully and re-fixing the same in the new cross arms / structure incl replacement of new hardware such as GI spindle, nut, bolt and washers complete all as directed
20
-
-
Supply, install, testing and commissioning of HT Feeder pillar Box outdoor type 11KV 50 HZ 3 Phase of suitable size not less than (1500x1500x1200 mm) duly powder coated with copper bus bar of 60x5 mm incl suitable insulators. It comprises following accessories such as totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, suitable for outdoor type, bottom cable entry with suitable cable glands ,CRCA steel sheet of thickness 3.15 mm with suitable angle iron frame work and legs of ISA 50x50x5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars with sloping canopy at top, double hinged doors at front with suitable locking arrangement,sheet will be treated under 8 - tank metal treatment process, complete all as specified and directed.
1
-
-
S&F in repairs for epoxy insulator suitable for 11 KV reel type inside HT feeder pillar box outdoor type including replacement of new nut, bolt and washer on bus bar and base complete all as specified and directed.
3
-
-
S&F of danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures andconventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size
5
-
-
Supply and fixing cable route indicator made out of PCC 1:2:4 of size 20cmx20cmx90cm dully painted with red colour by two coat of enamel paint and writing MES No details of HT cable with white paint on all sides complete all as directed.
15
-
-
S & F in repairs lightning arrester expulsion type complete with all fittings transmission class,discharge capacity 65 kilo amps,suitable for 11 KV all as directed
1
-
-
Carry out materials /mechinaries,labour for fault finding of 11 KV HT under ground cable length 1.5 KM in case of cable fault such as short circuit/burn out/ earth fault etc complete all as specified and directed.
2
-
-
Carry out materials /mechinaries,labour for cable route locator finding of 11 KV HT under ground cable route of length upto 1.5 KM in case of cable fault such as short circuit/burn out/ earth fault etc complete all as specified and directed.
1
-
-
Supply and fix control relay for charging motor 110V AC/DC, 220V AC/DC of suitable size for ACB of capacity 100 to 1200 Amps complete all as specified and as directed.
1
-
-
Supply only rubber hand gloves of 11 KV grade ISI marked.
3
-
-
Supply only fiber glass discharge rod in three sections and aluminium head with complete accessories suitable for 11 KV of 20 feet height.
2
-
-
S & F in repairs sealed maintenance free battery 2 Volts 100 Amps for UPS supply incl necessary connections complete all as directed. (Exide/Amron/TATA)
1
-
-
S&F MS Galvanised Chain link fencing including line wires any mesh, size and type to any type standard , rails, straining blots etc. including provision of binding wire.
80
-
-
Material and labour in Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed
0.5
-
-
S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as directed.
1.2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%