Military Engineer Services Tender

View complete overview of Goa MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Drainage Work
Eprocure
Opening Date31 Jan 2025
Closing Date21 Feb 2025
Tender Amount₹ 3,75,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
SCHEDULE "A" PART-III (DEMOLITION) Details of prepriced Schedule is given in tender documents.

1

25678

-

... More
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.

1

2881

-

... More
SCHEDULE "A" PART-V (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.

1

60908

-

... More
SCHEDULE "A" PART-VI (ROAD/ PATH/ HARDSTANDING) Details of prepriced Schedule is given in tender documents.

1

773799

-

... More
SCHEDULE "A" PART-VII (SEWAGE/ TREATED WATER SUPPLY) Details of prepriced Schedule is given in tender documents.

1

2803065

-

... More
SCHEDULE "A" PART-VIII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.

1

627118

-

... More
SCHEDULE "A" PART-IX (COMPOUND WALL & GATE) Details of prepriced Schedule is given in tender documents.

1

597188

-

... More
SCHEDULE "A" PART-X (RETAINING WALL) Details of prepriced Schedule is given in tender documents.

1

2365180

-

... More
SCHEDULE "A" PART-XI (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.

1

449564

-

... More
SCHEDULE "A" PART -XII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.

-

-

-

... More
INTERNAL WATER SUPPLY S&F two way bib cock with wall flange quarter turn (Low-flow) 16 mm dia. Make - Jaquar Model No KUP-35041PMGE or equivalent in Crab Tree/Kohler brand complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) Make - Jaquar Model No ALD-579 complete all as specified and directed by Engineer-in-Charge

1

-

-

... More
INTERNAL ELECTRIC SUPPLY: S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified in IS 732: 2019 and directed by engineer-in-charge. (a) 6-32 A, 230 V, 50 Hz, SP MCB (C curve)

6

-

-

... More
All as per item No 12.03 above but (b) 32 A, 230 V, 50 Hz, SPN MCB (C curve)

1

-

-

... More
S & F 20 W surface / wall mounted LED batten capable of delivering 2000 lumen, having PC diffuser, luminous efficacy of 90 lumen/W, CRI 80, PF 0.9, CCT 6500K, independent isolated SMPS based constant current electronic LED driver with THD 20%, surge voltage protection and other safety tests as per IS 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing. white coloured ABS end caps, IP 20 protection, input voltage range 140- 270 V, input frequency 50- 60 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed by the engineer-in-charge. Make: Philips Cat-Part No. BN 021C LED20S- PSU CW GR S2 or equivalent model of Havells Cat-Part No. LHEXAPP7IN1W020 or Wipro Cat-Part No. LL20-281-XXX-65AL1

8

-

-

... More
SEWAGE / MANHOLE/TREATED WATER SUPPLY: S&F 150 mm ID DWC HDPE (Double wall corrugated high density poly ethylene pipe) as per IS 16098 P.2 :2013- SN4 complete all as specified and directed by Engineer-in-charge. Make : Astral - D-Rex Double wall corrugated (Profiled) Pipe Product Code A0214150NEC012D

105

-

-

... More
S&F 200 mm ID DCWE (Double wall corrugated high density poly ethylene pipe) as per IS 16098 P.2 :2013- SN4 complete all as specified and directed by Engineer-in-charge. Make : Astral - D-Rex Double wall corrugated (Profiled) Pipe Product Code : A0214200NEA012D

1728

-

-

... More
Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Ductile Iron Pipes of Class K - 7 conforming to IS : 8329 : 80 mm dia Ductile Iron Double Flanged complete all as specified and directed by Engineer-in-charge

469

-

-

... More
Supply and laying SFRC Manhole cover complete all as specified and directed

90

-

-

... More
M & L for Two pack acrylic polymer modified cementatious water proofing compound applied as per manufacturer instructions complete as specified and directed

539.5

-

-

... More
Supply, installation, testing and commissioning (SITC) of Treated water pump capable of 15 m3 / hr discharge at 30 MWC head having solid handling capacity of minimum 5 mm size particles CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve, etc. all complete as specified in technical / particulars specification and directed by engineer-in-charge. 15.0 m3/hr @ 30mWC, (1W +1S), (for Treated Water Supply)

2

-

-

... More
M & L for construction of brick masonry valve pit as per of size 60 x 60 x 60 cm ( internal dimention ) including plaster on internal wall and floor complete with 30 x 30 x 6 mm MS angle iron frame. 3mm thick MS Top cover with locking arrangement including two coat of black bitumionous paint over a coat of red oxide primer on steel surface all as specified and directed

8

-

-

... More
Supplying, installation, testing & commissioning of three phase submersible non-clogging sewage pump capable to deliver minimum 600LPM or more water at minimum head of 20mtr discharge including GI fittings i.e elbows, tees, bends, NRV etc with starter panel having motor protection relay, single phase preventer with all connections respectively complete all as specified and directed ( For two U/G sewage collection sump- 2W + 2S)

4

-

-

... More
M & L for UPVC ball valve of size 65mm dia complete all as specified and directed

4

-

-

... More
M & L for horizontle boring of holes under road, pavement, hardstanding by trenchless technology using HDD (Horizontle Directing Drilling) Machine at the depth of 0.5m in any type of strata encountered at the designated and inserting 200mm dia pipe complete with the cost of HDPE pipe for any length all as per technical specifications and as directed by Engineer-in-charge Make; EONN PLAST or equivalent PN: SPE80

80

-

-

... More
All as per Item No 12.15 above but 150mm dia pipe complete with the cost of HDPE pipe for any length all as per technical specifications and as directed by Engineer-in-charge Make; EONN PLAST or equivalent PN: SPE80

20

-

-

... More
EXTERNAL ELECTRIC SUPPLY: Supply install test and commission LT Panel board, TPN 415 Volts, 50 Hz, 200 Amps capacity, out door cubical type floor mounted factory made double door dust and vermin froof fabricated out of CRCA sheet not less than 3.15 mm thick fixed on angle iron frame made out of 50x50x6 mm with cable chamber for individual feeders for incomming and outgoing connections, one set of indicator lamp RYB with switch and fuse, multifunction intelligent panel meter etc and with the followings INCOMING:- (a) MCCB with thermal release, 4 pole, 100 amps, 50 Hz, 415 Volt, 25 KA - 1 No (Incoming) OUTGOINGS:- (a) MCCB with thermal release, 4 pole, 100 amps, 50 Hz, 415 Volt, 25 KA-1 No. (b) MCCB with thermal release, 4 pole, 63 amps, 50 Hz, 415 Volt, 16 KA - 2 No. (c ) MCB TPN, 16Amps 415 V, 10 KA - 04 Nos (d) MCB SPN, 32 Amps 240 Volts, 10 KA - 01 Nos (e) Time switches 250 V single Phase of 20 Amp rating with contactor- 01 No.

1

-

-

... More
EARTHING: M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised strip of size 32 mm x 6 mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed.

13

-

-

... More
M & L for GI strip of size 32 mm x 6 mm as earth lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc complete all as specified and directed.

150

-

-

... More
SEWAGE TREATMENT PLANT (A) Supply, Installing, testing and commissioning of Sewage treatment plant based on principle of aerobic attached growth non clogging randomly moving bed bio reactor (MBBR) with primary, secondary and tertiary treatment process domestic sewage treatment plant having capacity of 65 KLD STP with Anoxic System as per NGT norms along with interconnecting equipment and setting up of in-plant laboratory for physical, chemical and bacteriological analysis inclusive of all glassware, testing chemicals and culture, testing tables and furniture, manuals, register, logbooks etc.comprising following accessories / equipment as per the OEM specification and drawing to achieve the indicated parameters mentioned in the tender documents complete all as specified and directed by engineer-in-charge including following equipments/ spares.

1

-

-

... More
(i) S & F of overflow type oil skimmer with flow of 0-50 LPH with belt size of 150 mm and motor rating of 0.5 HP - 01 Nos (ii) Supply, installation, testing & commissioning SS-304 Perforated, Screens with suitable lifting arrangement having size of 1000 mm (HT) x 500 mm (W) x 3.5 mm (T) & having 10 mm Openings to be fitted within Bar Screen Chamber -01Nos (B) SECONDARY TREATMENT SYSTEM: (i) Supply, installation, testing & commissioning of Submersible, non-clogging, Equalized waste Water Transfer Pump having having 3.25 m3/hr at 10 MWC head, continuous duty rating, cast iron casing, stainless steel impeller and stainless steel shaft complete directly coupled with induction motor 415 V, 3- Phase, 50 Hz of suitable capacity with 2900 RPM, IP 58 protection, class F insulation including installation, foundation as per OEM specification, electrical connection, with suitable rating of copper cables, starter panel with complete protection device such as over load current protection, phase reversal, single phasing, no voltage / over voltage protection, complete accessories such as voltmeter, Ammeter, LED indicators - 02 Nos (1 W + 1 S) Make: KSB/ KIRLOSKAR/ GRUNDFOSS/JYOTI/CRI/SUGUNA (ii) Supply, installation, testing & commissioning of Twin lobe rotary Air Blowers capable of delivering 42 m3/hr of atmospheric air at 3.7 kg/cm2 pressure, driven through "V" belt or directly coupled through flexible coupling to a TEFC motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply - 02 Nos (1 W + 1 S) (iii) M & L for Sodium Hypochlorite dosing system consisting of one HDPE tank of 10 litres capacity, positive displacement diphragm dosing pump having variable flow rate of 0-6 LPH along with motor suitable for operation at 230 V, 1- Ph, 50 Hz. supply and complete with necessary polypropylene piping, valves, strainers, low level switch and injection fittings. The pump shall have speed & stroke control -01 Nos

-

-

-

... More
(C) TERITIARY SYSTEM: (i) Supply, installation, testing & commissioning of Centrifugal Filter Feed Water Pump (FFP) capable of 3.25 m3/hr discharge at 20 MWC head having solid handling capacity of minimum 5 mm size particles CI casing & impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration elimination pads of approved design, drain pipe with valve - 02Nos (1 W+ 1 S) Make: KIRLOSKAR/CROMPTON GREAVES/ BEACON/ MATHER & PLATT/ GRUNDFOSS/ KSB/ JYOTI/CRI (ii) Multigrade Sand Filter: Supplying, installation, testing and commissioning of MS vessel filter having diameter of 700 mm & HOS of 1875 mm. Filter shall be suitable for test pressure of 5.0 kg / cm2 and Working Pressure of 3.5 kg/cm2 shall include media (Pebbles, Sand, Silex, Fine Sand, Fine Silex), standard fittings like pressure gauges, sampling cock, backwash, including frontal piping and, valves. (Minimum Shell thickness of 4.0 mm & Minimum Dishend thickness of 4.0 mm) - 01 Nos (iii) Activated Carbon Filter: Supplying, installing, testing and commissioning of MSEP vessel filter having diameter of 1000 mm & HOS of 1875 mm. Filter shall be suitable for test pressure of 5.0 kg / cm2 and Working Pressure of 3.5 kg/cm2 shall include media (Activated Carbon with supporting Media), standard fittings like pressure gauges, sampling cock, backwash, including frontal piping and valves. (Minimum Shell thickness of 4.0 mm & Dishend Thickness 4.0 mm). - 01 Nos (iv) Supply, installation, testing & commissioning of Non-clogging type centrifugal Sludge Transfer Pumps (P3) capable of 8.13 m3/hr discharge at 8 MWC head having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control, - 02 Nos (1 W + 1 S) Make: KIRLOSKAR/ BEACON/ MATHER & PLATT/ GRUNDFOSS/ KSB/CRI

-

-

-

... More
(v) Supply, installation, testing & commissioning of Non clogging type solid handling pump capable of 0.125 m3/hr discharge at 6.5 kg/cm2 pressure having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control - 02 Nos Make: KIRLOSKAR/ BEACON/ MATHER & PLATT/ GRUNDFOSS/ KSB/CRI (vi) Supply, installation, testing & commissioning of Filter press having size of 5 mtr X 2 mtr X 0.8 mtr per following specification - 01 each (a) Type - plate and frame (b) Plate - poly propelene (c) Frame - mild steel (d) Filter cloth - suitable size (e) Fluid handled - sludge (f) Nature of solids - Biological (g) Sludge quantity - 41 Kg/Batch (h) Sludge concentration - 1% (vii) Supply, installation, testing and commissioning (SITC) of Non clogging type Centrifugal Pumps having solid handling capacity of upto 105 mm size particles having CI casing & impeller complete with all accessories, motor of required capacity, delivery header with isolation valve, pressure gauge with isolation cock, level controller (with wiring) to control (for Sump to Inlet Chamber) Make: KSB/ KIRLOSKAR/ GRUNDFOSS/JYOTI/CRI/SUGUNA (a) 2.97 m3/hr discharge at 30 MWC (1W +1S), Peak Flow - 02 Nos (b) 0.74 m3/hr discharge at 30 MWC (1W +1S), Normal Flow - 02 Nos (c) 15.9 m3/hr discharge at 25 MWC (1W +1S), Peak Flow - 02 Nos (d) 3.97 m3/hr discharge at 25 MWC (1W +1S), Normal Flow - 02 Nos

-

-

-

... More
(D) CONTROL PANEL & CABLING FOR ALL ELECTRICAL ITEMS OF WORK: (i) Supply, installation, commissioning and testing of factory made, CPRI Approved type tested, indoor, cubical compartmental type " CONTROL PANEL" (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws - 01 Nos The MCC shall comprise of the following: [a] Busbar Chamber: [i] Copper busbar of rated capacity minimum 100 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection- 01 Set (3 P + N) [b] Incoming: [i] 32 A, 415 V, Ics = Icu =16 kA, 50 Hz, FP MCCB with adjustable overload settings, adjustable short-circuit settings, adjustabble neutral protection, adjustable earth- fault settings, instanteneous protection and microprocessor based trip unit- 01 Nos. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 Nos. [c] Outgoing: [i] 10 A, 10 kA, 415 V, 50 Hz FP MCB (C- curve)- 15 nos

-

-

-

... More
(ii) Supply, installation, commissioning and testing of Fully automatic DOL starter, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring as per following: (i) for Equalized Waste Water Transfer Pump (1 HP) - 2 Nos (ii) for Air Blower (3 HP) - 2 Nos (iii) for Sludge Recerculation Pump (1.5 HP) - 2 Nos (iv) for Filter Feed Pump (1.5 HP) - 2 Nos (v) for Dosing Pump (0.5 ) - 02 Nos (1W + 1S) (vi) for Anoxic Agitator( 1 HP) - 02 Nos (1W + 1S) (vii) for Non Clog Type pump ( 0.5 HP) - 02 Nos (1W + 1S) (iii) S & F of Agitators wiith Flange type gear box, voltage rating 415 V with speed of 1400 RPM with munting flange type with motor rating 1 HP & thickness of base plate 5-6 mm and size of base 400 X 200 mm - 01 Nos (iv) M & L for 4 core, 10 mm², ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS: 7098 (Part 1)- 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS: 8130- 1984, PVC inner sheath, single armouring of galvanized steel strip/wire and PVC Type ST- 2 outer sheath conforming to IS: 5831- 1984, including clamping and termination - aprox 500 Rm (E) PIPING FOR AIR BLOWER: (i) S & F of UPVC PIPE SCHEDULE 80 /EPDM FOR FINE BUBBLE (a) 40 mm NB - 15Rm (b) 20 mm NB - 10Rm

-

-

-

... More
(ii) BALL VALVE: Supply, installation, testing and commissioning of wafer type PN 1.6 rated short pattern CI ball valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated. (a) 40 mm NB - 05 Nos (b) 20 mm NB - 01 Nos (iii) PRESSURE GAUGE: S & F of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories - 2 Nos (iv) NON-RETURN VALVE: Supply, installation, testing and commissioning of 40 mm NB wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated complete all as specified and directed by the engineer-in-charge - 02 Nos (F) FOR EQUALIZED WASTE WATER TRANSFER PIPING: (i) M & L for sewage water piping of 50 mm NB SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed by the engineer-in-charge

-

-

-

... More
(ii) BUTTERFLY VALVE: Supply, installation, testing and commissioning of 50 mm NB wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated complete all as specified and directed by the engineer-in-charge - 12 Nos (iii) NON-RETURN VALVE: Supply, installation, testing and commissioning of 50 mm NB wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated complete all as specified and directed by the engineer-in-charge- 04 Nos (iv) PRESSURE GAUGE: S & F of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, etc. as specified and directed by engineer-in-charge- 04 Nos (G) PIPING FOR NON-CLOG TYPE SOLID HANDLING PUMPS: (i) M & L for sludge recirculation piping of 25 mm NB SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed by the engineer-in-charge

-

-

-

... More
(ii) BALL VALVE: Supply, installation, testing and commissioning of 25 mm NB wafer type PN 1.6 rated short pattern CI ball valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated complete all as specified and directed by the engineer-in-charge- 08 Nos (iii) NON-RETURN VALVE: Supply, installation, testing and commissioning of 25 mm NB PN 1.6 rated two piece design vertical/horizontal lift non return valve (NRV), having Bronze body, Conforming to Bronze IBR 282(a)(iv) Gr.B, renewable seat & disc, screw female BSP taper threads end connection, etc complete all as specified and directed by the engineer-in-charge - 02 Nos (iii) PRESSURE GAUGE: S & F of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, etc. as specified and directed by engineer-in-charge - 02 Nos (H) PIPING FOR HYPO DOSING PUMP: (i) M & L for Hypo dosing piping of 25 mm NB SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed by the engineer-in-charge (ii) BALL VALVE: Supply, installation, testing and commissioning of 25 mm NB wafer type PN 1.6 rated short pattern CI ball valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated etc complete - 04 Nos

-

-

-

... More
(iii) NON-RETURN VALVE: Supply, installation, testing and commissioning of 25 mm NB PN 1.6 rated two piece design vertical/horizontal lift non return valve (NRV), having Bronze body, Conforming to Bronze IBR 282(a)(iv) Gr.B, renewable seat & disc, screw female BSP taper threads end connection, etc., complete all as specified and directed by the engineer-in-charge - 02 Nos (J) PIPING FOR SLUDGE TRANSFER PUMP: (i) M & L for sludge transfer piping of 65 mm NB SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed by the engineer-in-charge (ii) BUTTERFLY VALVE: Supply, installation, testing and commissioning of 65 mm NB wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated complete all as specified and directed by the engineer-in-charge - 05 Nos (iii) NON-RETURN VALVE: Supply, installation, testing and commissioning of 65 mm NB wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated complete - 02 Nos (iv) PRESSURE GAUGE:S & F of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories, - 02 Nos

-

-

-

... More
(K) PIPING FOR INTERMEDIATE SUMP: (i) M & L for sludge transfer piping of SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated (a) 65 mm NB - 173 Rm (b) 40 mm NB - 81 Rm (ii) BUTTERFLY VALVE: Supply, installation, testing and commissioning of wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated (a) 65 mm NB - 05 Nos (b) 40 mm NB - 05 Nos (iii) NON-RETURN VALVE: Supply, installation, testing and commissioning of wafer type PN 1.6 rated swing check type multidoor reflux valve (NRV), designed & tested as per IS 5312 (Part- 2): 1986, suitable to handle clear water having turbidity up to 5000 PPM, having CI body, door and diaphragm, leaded tin bronze seat rings and flange drilling standard end connection, etc., duly insulated (a) 65 mm NB - 02 Nos (b) 40 mm NB - 02 Nos (iv) PRESSURE GAUGE: S & F of 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0- 25 bar complete with accessories - 08 Nos

-

-

-

... More
(L) PIPING FOR LMH: (i) M & L for sludge transfer piping of SS 304 including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators, etc. including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fasteners) with necessary accessorie, duly insulated (a) 65 mm NB - 535 Kg (b) 40 mm NB - 251 Kg (ii) BUTTERFLY VALVE: Supply, installation, testing and commissioning of wafer type PN 1.6 rated short pattern CI butterfly valve having Gr. FG-200 CI body conforming to IS 210: 2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI- 410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI- 125, duly insulated (a) 65 mm NB - 03 Nos (b) 40 mm NB - 03 Nos (M) NOTES FOR PACKAGED TYPE STP: (I) The scope of item starts from pumping arrangement of sewage from equalization tank (excluding equilizing tank) till discharge point of treated water into treated water tank. All piping, pumping and other necessary components in between whether indicated in description of item or not are deemed to be included in the quoted rate of item and nothing extra shall be payable for providing a functional package type STP of capacity specified. (ii) The PCC platform of size 10m x 3.0m shall be provided for STP which shall be measured and paid seperately under Sch 'A' part-I.

-

-

-

... More
PHASE-II : COMPREHENSIVE MAINTENANCE AND OPERATION (Item No 12.32 to 12.35) (For the period of 120 months after completion of Phase-I) (A) Comprehensive Maintenance: The scope of comprehensive maintenance includes maintenance of complete infrastucture under this work and replacing all defective components and restoring any defect/ deformity/wear and tear during defect liability period of two years and comprehensive maintenance of all STP components under this job, Sl. Item No 01, 02, 04 & 05 of Schedule 'A' Part-I and all pumps and LT panels in the scope of entire tender for further period of eight years after completion defect liability period. The scope shall also include comprehensive maintenance of all electrical & Sewage Pumps items such as main switch, starter, change over switch, MCCB, voltmeter, ammeter, panel board etc, Sewage water pump, valve system, controlling system, daily checking, leakage, checking noise, cleaning of plant and its surrounding area etc, as per manuafactures instructions and as specified and directed by Engr-in-charge. NOTE: (a) Comprehensive maintenance includes replacement of all defective/ worn out/damaged parts with new parts and nothing eatra shall be paid on this account except the payment specified in this item. (b) The contractor shall be responsible for periodic maintenance, as per maintenance schedule and specified including renewal / replacement of parts, lubricants, fittings/ fixtures, filling of bacteria, etc required for smooth functioning of the plant as per manufactures instructions. (c) The rate quoted shall be deemed to be inclusive of safety gear & required tools for maintenance. (d) The cosumable chemicals like sodium hypoclorite and chlorine shall only be supplied by GE for treatment of sewage and all other spares/ consumable are to be provided by the contractor without any extra cost. (e) Electricity for running of plant will be provided by GE.

1

-

-

... More
(f) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsover maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly. (g) The contractor shall provide display board at proper location near each installations duly writing the name of all concerned who are maintaining and running the plant. (h) In case of non functioning of STP plant, penal recovery @ Rs. 5000/- per day shall be effected starting 24hrs after the start of period on non functioning. (j) The installations shall remain in posession of the contractor for complete period of comprehensive maintenance and he shall be resposible for keeping the plant in running. (k) Any penalty imposed by regulating authorities related with upkeep of STP and quality of effluent shall be borne by contractor during the period and nothing shall be paid on this account. (l) The sludge produced from any component of STP shall become contractors property and shall be removed from site as early as possible. The rate shall quoted accordingly

-

-

-

... More
(B) OPERATION OF THE PLANT Operating and keeping the STP of 65 KLD capacity in running/ operational condition by deploying required technical staff to produce the treated effluent of specified quality including Sundays and holidays including all connected electrical & Sewage Pumps items such as main switch, starter, change over switch, MCCB, voltmeter, ammeter, panel board etc, Sewage water pump, valve system, controlling system, daily checking , leakage, checking noise, cleaning of plant and its sorrounding area etc all as specified and directed by Engr-in-charge. NOTE: (i) Contractor shall deploy skilled operator (FGM) as per requirement for Operation of STP for period of 10 (ten) years after completion of Phase-I (ii) The contractor shall employ FGMs having minimum qualification of ITI from recognised institute having sufficient knowledge and experience of minimum 02 years in maintenance/ operation of similar work. The operators must be competent to carry out the repairs/ maintenance of plant as required (iii) The operaters shall maintain the desired quality treated water including tracing out and rectification of minor leakages in pipe line/ valves during the period (iv) The operators shall operate electrical equipement, pumps and maintain the STP in workable condition by checking daily leakages, noise, cleaning the plant and its surrounding areas of plant as directed. (v) The contractor shall maintain all registers under various rules, and shall be produced to the Engineer-in-Charge as well as officers detailed by central labour department. (vi) The unit rate quoted shall be deemed to be included for cost of labour for daily routine maintenance for trouble free functioning of installation. (vii) The quoted rate shall be deemed to be inclusive all consumables required for comprehensive maintenance & operation of STP except sodium hypochlorite and chlorine.

-

-

-

... More
(viii) The quoted rate is deemed to be inclusive of tools & testing instruments required for operation & maintenance of STP plant. (ix) The sludge cakes procured after treatment shall become contractors property and shall be removed from premises of STP as early as possible. The rate shall be quoted accordingly. (C) PAYMENT TERMS FOR COMPREHENSIVE MAINTENANCE AND OPERATION (a) Yearly breakdown payment against this item (Phase-II) shall be made as per following schedule during the period of Ten years. (a) After 1st year - 4.50% (b) After 2nd year - 5.00% (c) After 3rd year - 6.50% (d) After 4th year - 8.00% (e) After 5th year - 9.00% (f) After 6th year - 10.00% (g) After 7th year - 12.00% (h) After 8th year - 13.50% (j) After 9th year - 15.00% (k) After 10th year - 16.50% NOTE:- Yearly amount as above shall be paid in equal installments every month after satisfactory report to be given by GE

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.