Military Engineer Services Tender

View complete overview of Goa MES Tender

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date7 Apr 2022
Closing Date28 Apr 2022
Tender Amount₹ 30,52,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking down carefully old unserviceable UG cable (HT) of any size from the trenches/wall/pole and keeping aside for reuse and remove the unserviceable cable from site after affording credit depending on its serviceability state including removal of brick/PCC cable cover complete all as specified and as directed. Note: Excavation and earthwork shall be measured and paid for Separately

250

-

-

... More
Supplying & laying including testing of XLPE insulated, armoured, heavy duty, HT UG electric cable in trenches/wall/cable tray/saddling/GI pipe or specified as per site requirement with stranded aluminum conductor 11 KV grade of following sizes:- Note :- Excavation & earth work, sand cushioning and PCC cover for cable protection shall be measured & paid seperately

-

-

-

... More
(a) 3 core 95 Sqmm

100

-

-

... More
(b) 3 core 120 Sqmm

50

-

-

... More
(c) 3 core 185 Sqmm

50

-

-

... More
(d) 3 core 240 Sqmm

50

-

-

... More
Laying only in repair including testing of serviceable, HT UG cable of following sizes obtained from item No 4 here in before all as specified and as directed. Notes : 1. Serviceable cable obtained from Sl item No 4 above shall be reused. 2. Excavation and earth work, sand cushioning, PCC cover for cable protection shall be measured and paid separately.

-

-

-

... More
(a) 3 core 95 Sqmm

50

-

-

... More
(b) 3 core 120 Sqmm

50

-

-

... More
(c) 3 core 185 Sqmm

50

-

-

... More
(d) 3 core 240 Sqmm

50

-

-

... More
Supply and lay un-reinforced pre-cast concrete cable cover, class HV, type 1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed.

750

-

-

... More
Laying only un-reinforced pre-cast concrete cable cover, class HV, type 1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed.

500

-

-

... More
Supply and spread dry river sand in trenches for cable cushioning all as specified in clause 19.75 of SSR Part-I complete all as specified and as directed. Note:- Punned thickness of sand only shall be measured & paid.

25

-

-

... More
Supply & Laying in repair 80mm dia GI tubing light grade with necessary fittings as in cable protection in trenches/fixed on wall / floor including necessary clamps bolts and nuts complete all as specified and as directed.

6

-

-

... More
Supply, jointing & testing Indoor end termination cable joininting kit,heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 120 Sqmm to 185 Sqmm all as specified and as directed.

2

-

-

... More
Supply, jointing & testing Indoor end termination cable joininting kit, heat shrinkable type 11 KV HT joint kit suitable for PVC / XLPE insulated stranded aluminium conductor of size 3 core 240 sqmm to 300 Sqmm all as specified and as directed.

2

-

-

... More
Supply, jointing & testing straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 95 Sqmm to 185 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.

5

-

-

... More
Supply, jointing & testing straight through type cable joininting kit heat shrinkable 11 KV HT joint kit suitable for 3 core 240 Sqmm to 400 Sqmm PVC / XLPE insulated stranded aluminium conductor all as specified and as directed.

2

-

-

... More
S&F in replacement of old U/S Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white, with letters, figures & conventional skull & bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT 25x20 cm size all as specified & as directed.

20

-

-

... More
M&L for Testing of faulty HT UG cable upto 240 Sqmm by checking the insulation resistance using 5000v / 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having minimum length of 500 RM and pin point the fault location complete all as specified & as directed. Note: In single stretch having minimum length 500 RM whatsoever Nos of fault shall be paid as each job

1

-

-

... More
M&L for Testing of faulty HT UG cable upto 240 Sqmm by checking the insulation resistance using 5000v / 10000v fault insulation locator tester, identify any number of cable fault in a single stretch (from source to load) having length more than 1500 RM and pin point the fault location complete all as specified & as directed. Note : In single stretch having length more than 1500 RM whatsoever Nos of fault shall be paid as each job

1

-

-

... More
S&F in repairs Phase indication lamp LED type of colour complete all as specified and as directed.

30

-

-

... More
M&L for testing of resistance of earthpits of transformer,panels etc after testing the report shall be furnished in standard format all as specified and as directed

50

-

-

... More
M&L for Servicing /Repair to HT Pannel of having vaccum circuit breaker 11 KV rating of capacity 250MVA and current rating upto 630 Amps to 2000 Amps by replacing defective/ wornout parts, adjustment of gaps for smooth operationall as specified and as directed.Scope of work consist of: (a) Cleaning of VCB with air blower and removing dust particles. (b) Cleaning of insulating places of VCB by using CTC/ CRC/ Thinner as required and recommended (c) Checking the arcing contact gap of vaccum interrupter, if gap exceeds the permissible limits, readjust as recommended. (d) Cleaning the main contacts to remove carbon or any other unwanted particals if visible.

9

-

-

... More
(e) Dismantling and cleaning the insulated surfaces and arc barrier with CTC and CRC. (f) Checking / repair and replacement of all minor ac/dc electrical wiring for electrical/ mannual operation of HT panel loading and all others function based on the ac/dc operation of HT panel etc complete in all respect as specified (g) Checking of all nuts/ bolts springs, levers, latches, connectors etc and adjustment etc required and recommended. (h) Recording IR Values of CTs and PTs (j) Cleaning of bus bar spout. (k) Checking of all moving parts for proper functioning of VCB and adjustment as per manufacturer recommendations. (l) Removing all the moisture content inside the VCB panel all as specified by OEM. Note :- (i) The cost of minor parts ie nuts ,bolts, spring washers,dust cover ring of isolarors contacts,clips pins for release prop,Y phase shrouded over side stop pin,and all other minor parts ie packing essentially required to make the panel dust proof shall be deemed to be included in the rate quoted by the contractor . (ii) The servicing will be carried as per norms of OEM

-

-

-

... More
S&F in replacement , testing and commissioning tripping coil operated by AC or DC supply complete with electric copper wire of suitable size all as specified and as directed

4

-

-

... More
S&F in replacement, testing and commissioning closing coil operated by AC or DC supply complete with electric copper wire of suitable size all as specified and as directed

4

-

-

... More
S&F in replacement bakelite kitkat complete with HRC fuse 2-20 amps of suitable for HT panel grey in colour including necessary nuts for fixing in position all as specified and as directed.

8

-

-

... More
M&L for Strip Opening the busbar of the HT 11 KV VCB panel from 800 Amps to 2000 Amps, removing the old teared/ unsv insulation from the bus bar, checking the IR value before fixing the HT sleeve and refixing the heat shrinkable insulating tape sleeve suitable for 11 KV busbar not less than 3mm thick having dielectric strength not less than 15kv/mm and HT insulation tape for CT/ PT connection complete with a certificate from NABL lab. and checking the IR value before testing and commissioning the bus bar all as specified and as directed. Note :- Test sheet of IR value shall be submitted by the contractor, at no extra cost to Department and all expenses for testing requirement shall be borne by the contractor including transportation and T&P.

10

-

-

... More
M&L for Taking out ACB of Siemens make, of capacity 800A to 2000A Amps, 3pole , 415 volts,125 KA indoor type from its sub cubicle and carrying out routine maintenance as per manufacturer maintenance manual, examine the moving isolating contacts for any discolouration, cluster contacts, remove the arc chutes, check the SMC moulding are intacts, examine the moving contacts main contacts silver tips, spring mechanism, clean all contacts with a suitable solvent and contacts regreased with HP multipurpose grease, all contacts setting checked, readjusted if required, and regreased with HP multipurpose grease, all tripping device like manual trip, under voltage, shunt trip release, over current and earth fault tripping device to be tested, readjusted and confirm all tripping device is in healthy condition, check and record IR value of ACB, with 1.1. KV LT megger calibrating ground fault / short circuit, overload relays for tripping & timing complete and rendering test report all as specified and as directed. NOTES:- (i) The scope of work includes following :- (a)Inspection & cleaning the mechanism house (b)Operation of door interlock, interlocking plate & shutter operation inside of panel.

2

-

-

... More
(c)Check the Mechanical ON-OFF function, electrical & mechanical operation and damage part of VCB/ACB. (d)Re-greasing and oiling of breaker mechanism, adjustment of various mechanism setting as required, checking contact tightness, contact erosion pins, manually vaccum check of VCB/ACB. (e)Racking-Rack out operation in Test & service position of VCB/ACB trolley. (f) Megger test (IR value - 1KV / 2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (g)CRM Test (contact resistance) of Vacuum Interrupter R, Y, B in on condition outside of panel. (h)Time test of contract pole by Test kit (in mile second). (j)Function of closing coil, Trip coil, spring charging motor, auxiliary contact, limit switches etc. (k) Checking & lubrication of various interlocks. (l) Submission of test report in standard format of vacuum circuit breaker. (ii)Tools and plants and testing instruments required for servicing of VCB/ACB shall be arranged by the contractor. (iii)The unit rate quoted shall be deemed to include the cost of grease, lubricating material, cleaning material etc as required.

-

-

-

... More
(iv) After servicing, report shall be furnished in standard format approved by Engineer-in-Charge.

-

-

-

... More
Supplying and laying in replacement of old unsv synthetic Rubber insulated mats 3 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and as directed.

1

-

-

... More
M&L for calibration of relays for primary current /voltage injection test complete for 11KV VCB panels and ACB panels/ DG panels complete all as specified and as directed.

10

-

-

... More
S&F in replacement, testing and commissioning of resin current transformer dual core dual ratio for protection and class I accuracy suitable for 11 KV, 100/50/5+5A of primary wound type with adjustable VA bourden and accuracy in clearing the CT wiring with primary and secondary injection kit including identification to the base and connecting links to HT/VCB to match with the existing system complete all as specified and as directed.

3

-

-

... More
S& Fixing in replacement & testing and commissioning of resin Potential Transformer 3 Phase, 11KV/110V, 15 VA Cast rasin wound as directed and approved by GE.

3

-

-

... More
S&F in repair of 11 KV bus bar supporting spout / insulators 130 MM LONG 60 MM DIA /as per sample single pole for indoor use 400 to 800 Amp suitable for existing panel complete all as specified and as directed..

15

-

-

... More
S&F in repair of fuse indoor type, 11 KV, type PTAVT, Amps 3.15, 50hz, current ratio 800-400, including removing of old unsv fuse complete all as specified and as directed..

2

-

-

... More
M&L for repair and servicing of Automatic power factor correction panels of different capacities including complete rewiring of the APFC Panel, replacement of the auxilary contactors, three phase capacitors, indictors, damping resistors and relays and checking the serviceability of the all the components and replacement of the defective parts all as specified and as directed. Note: The above quoted rate includes servicing and internal control wiring of the APFC panel and all the connected items to be fixed are to be meausured and paid seperately under relevant items as below

2

-

-

... More
Supply only 3 Phase cylindrical shape power capacitor of capacity 30 Kvar suitable for APFC Panel all as specified and directed

10

-

-

... More
Supply only 3 Phase cylindrical shape power capacitor of capacity 40 Kvar suitable for APFC Panel all as specified and directed

10

-

-

... More
Supply only 3 pole power contactors for capacitor switching of power capacitors from range 30 to 40 Kvar

10

-

-

... More
Supply only APFC 3 Phase relay suitable for APFC panel of capacity not less than 200 Kvar all as specified and directed

6

-

-

... More
Supply and fixing in repair of old unsv HRC fuse assembly of any type and size all as per existing having capacity 200 Amps-400 Amps all as specified and as directed.

15

-

-

... More
Disconnecting all incoming and outgoing cable connections, earthings, removing the transformer from the plinth/platform/two pole & four pole mounted, indoor/outdoor type removing defective step down 11 KV / 0.433 upto 630 KVA transformer of any make, plinth/floor/pole mounted, indoor/outdoor type, from site (Naval Base, Karwar), transporting with required T&P to local/authorised work shop for carrying out the repair to transformer all as specified and as directed.

1

-

-

... More
M&L for dismantling & re-assembling carefully electrical connections from HT/LT sides of the transformer keeping them at safe side and taking out the transformer core for carrying out complete overhauling which shall complete the following repair work/rewinding etc :- (a) Taking out the transformer oil from transformer into seperate container barrel. (b) Taking out the core / coil assembly of transformer. (c) Cleaning of transformer inside by used transformer oil. (d) Re-fixing the core/coil in transformer including heating up of transformer core assembly to remove moisture after carrying out the repair as required including filtration /dehydration of oil to remove moisture and suspended dust particles . (e) Replacement the crock gasket set for top cover, spindles, HT / LT bushing etc. as required (f) Refilling of the removed transformer oil after heating up for removal of moisture. (g) Re-fixing of the transformer top cover with nuts, bolts and washers (h) Testing of transformer Complete.

1

-

-

... More
Notes : (i) Replacement of LV / HV bushes / spindles / rewinding of HV / LV coils (replacement or reconditioning ) / tap changer/insulators etc shall be measured and paid for separately under relevant items of BOQ. (ii) Top up/ replacement of transformer oil (if required) shall be measured and paid for separately under respective item of BOQ.

-

-

-

... More
S&F in repairs LV leg strip of copper conductor for transformer of capacity up to 630 KVA complete with insulation, varnishing by vaccum impregnation and baking of strip assembly to match with the existing etc complete all as specified and as directed.

50

-

-

... More
S&F in repairs HV leg coil of copper conductor for transformer of capacity up to 630 KVA complete with insulation, varnishing by vaccum impregnation and baking of coil assembly to match with the existing original winding coils, etc complete all as specified and as directed.

80

-

-

... More
S&F in repairs HT 11 KV brass spindle, threaded with washers, nuts,lock nut and rubber seal suitable for transformers of any make /Type rating 630KVA all as specified and as directed.

6

-

-

... More
S&F in repairs LV bushing 0.433 / 0.415 KV for transformer 630KVA complete set all as specified and as directed.

8

-

-

... More
Supply and replacement of temperature gauge circular dia type of standard size and suitable for indoor/outdoor type transformer of 630 KVA capacity all as specified and as directed.

2

-

-

... More
Supply and replacement of breather assembly duly filled with silica gel suitable for trnasformer of cap upto 630 Amps transformer complete all as specified and as directed.

3

-

-

... More
Transportation back the repaired transformer from work shop to respective sites, reinstall it, reconnect all the incoming and outgoing cable connections, earthings, by properly crippling using lugs of suitable size, tapping the bushes/busbar, using HT insulation tape and testing complete in all respects of capacity upto 630 KVA all as directed and specified.

1

-

-

... More
Supply & filling of transformer oil confirming to IS-335 of 1993 as in topping of/replacement upto desired level of transformer oil capacity all as specified and as directed.

100

-

-

... More
M & L Painting to the transformer of any capacity upto 630 KVA complete with synthetic enamel paint as existing earlier by spray painting including filling cavities with filler one coat after cleaning all dust etc and marking SM/MES No on the transformer at both site complete all as specified and as directed.

2

-

-

... More
M&L for earthing complete in repairs with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 20 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009 all as specified and as directed Note :- (i) All joints either strip to strip or strip to earth plate are fixed with welded joints. (ii)GI earth strip upto 7.5m height is deemed to included under quoted rate.

6

-

-

... More
M&L for Servicing of dry cast Transformer upto 1600KVA , 11 KV/433V by disconnecting incoming & outgoing power supply, opening up, cleaning the transformer internally & externally inspecting all the metering equipments, tightening all electrical connections checking & recording insulation resistance on both LT & HT sides, checking & recording earth resistance complete through authorised service engineer of OEM all as specified & as directed. Location:-DSS-1/DSS-1A/DSS4/DSS-4A/DSS-6/DSS-8/DSS-9. Note:- a) The above quoted rate includes dismantling of the existing HT cable connected with the transformer and carrying out the meggering test on both HT/LT side and reconnecting the existing HT cable with the transformer. b) The above quoted rate includes all the T&P required for testing and servicing work all as specifed and direcetd. (c) The above quoted rate includes all the minor parts required for the servicing i.e. Nuts and bolts, washers, cotton waste, grease etc.

2

-

-

... More
M&L for Servicing /Repair to HT Panel of having vaccum circuit breaker 33 KV rating of capacity current rating upto 1200 Amps to 1600 Amps of any make & type, servicing of VCB by cleaning contacts moving parts removing dust particles from spout gear mechanisum and moving parts repairs to motor, change spring mechanisum tightening of nuts & bolts of entire trolly components all as directed inserting in trolly, testing, commissioning putting on the supply on load complete all as specified and as directed and scope of work incudes following :- (a) Inspection and cleaning breaker mechnisum assembly & check proper operation and repair work.. (b) Servicing & overhauling for proper operation of door interlock, interlocking plates and shutter assembly inside of panel.permissible limits, readjust as recommended. (c) Check the mechanical on/off function, electrical & mechanical operation & damaged part of VCB. (d) Re-greasing with jelly of breaker mechanisum, adjustment of various mechanisum, setting as required, checking contact tightness, contact erosion pins, manually vaccume check of VCB.

3

-

-

... More
(e)Racking-Rack out operation in test and service position of VCB trolly (f) Megger Test (IR Value- 1KV/2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (g) CRM Test(Contact Resistance) of Vacume Interupter RYB in On condition out side of panel. (h) Time test of contact pole by test kit (in mili seconds). (j) Function of closing coil, trip coil, spring charging motor, auxilliary contact, limit switch etc. (k) Checking and lubrication of various interlocks. (l) Removing all the moisture content inside the VCB panel all as specified by OEM. (m) After servicing test report shall be furnished in standard format approved by E-in-C. Notes :- (i) The cost of minor parts ie nuts ,bolts,spring washers,dust cover ring of isolarors contacts,clips pins for release prop,Y phase shrouded over side stop pin,and all other minor parts ie packing essentially required to make the panel dust proof shall be deemed to be included in the rate quoted by the contractor . (ii) The servicing shall be carried as per norms of OEM.

-

-

-

... More
M&L for attending emergency breakdown for 33 KV VCB of any capacity as and when ordered by Engineer-in-Charge, including servicing, adjusting & fault finding & rectifying the fault by skilled Engineer & testing the unit complete & submitting test report all as specified and as directed and scope of work incudes following :- (a) Inspection and cleaning breaker mechnisum assembly & check proper operation and repair work.. (b) Servicing & overhauling for proper operation of door interlock, interlocking plates and shutter assembly inside of panel.permissible limits, readjust as recommended. (c) Check the mechanical on/off function, electrical & mechanical operation & damaged part of VCB. (d) Re-greasing with jelly of breaker mechanisum, adjustment of various mechanisum, setting as required, checking contact tightness, contact erosion pins, manually vaccume check of VCB.

2

-

-

... More
(e)Racking-Rack out operation in test and service position of VCB trolly (f) Megger Test (IR Value- 1KV/2.5KV) E-RYB, RY-YB, BR-R'R, Y'Y, B'B. (g) CRM Test(Contact Resistance) of Vacume Interupter RYB in On condition out side of panel. (h) Time test of contact pole by test kit (in mili seconds). (j) Function of closing coil, trip coil, spring charging motor, auxilliary contact, limit switch etc. (k) Checking and lubrication of various interlocks. (l) Removing all the moisture content inside the VCB panel all as specified by OEM. (m) After servicing test report shall be furnished in standard format approved by E-in-C.

-

-

-

... More
M&L for checking & testing Current Transformer 33 KV comprising the following and as specified & directed :- (a) Cleaning of CT by removing dust, moisture etc. from body. (b) Checking of wiring of secondary side of CT. (c) Checking insulation Resistance, Polarity Test. (d) Checking CT Ration and take Trip Trial from CT primary injection test. (e) Repairing defective control wiring of CT, Checking body earthining of CT. (f) Tightening properly all connections.

3

-

-

... More
M&L for checking & testing Potential Transformer 33 KV comprising the following and as specified & directed :- (a) Cleaning of CT by removing dust, moisture etc. from body. (b) Checking of wiring of secondary side of CT. (c) Checking insulation Resistance, Polarity Test. (d) Checking CT Ration and take Trip Trial from CT primary injection test. (e) Repairing defective control wiring of CT, Checking body earthining of CT. (f) Tightening properly all connections.

3

-

-

... More
M & L for calibration of relays for primary current/voltage injection test complete for 33KV VCB panels complete including re-setting of relay as per load & fault condition, pick up voltage & interlock operation all as specified and as directed.

3

-

-

... More
M&L for taking out VCB bus bar of capacity 800 to 2000 Amps from 33 KV VCB bus bar compartment and cleaning the bus bar with CTC liquid replacement of HT sleeves of suitable sizes of Make-Raychem BPTM 120x50, 295342/18:49 upto 50 KV , HT insulation Tape for CT/PT connection, Re-fixing of bus bar by means of nuts, bolts & washers of suitable size including painting of bus bar compartment internally with insulation paint for removing moisture from VCB as specified and directed

3

-

-

... More
M&L for carrying out high voltage test for 33 KV VCB, CT, CT Bus Bar, PT, PT Bus Bar, Bus Bar Duct, Spout & Insulators, Main Chamber etc, upto 45 KV all as specified and as directed.

3

-

-

... More
Supply only following spare parts of the indoor type 33 KV VCB of Make-Simens all as specified and directed:-

-

-

-

... More
(a) Closing Coil 110 V AC/DC for 33 KV VCB

1

-

-

... More
(b) Tripping Coil Assembly for 33 KV VCB

1

-

-

... More
(c)Trip Catch Assembly for 33 KV VCB

1

-

-

... More
(d) Vacuum Interrupter for 33 KV VCB

3

-

-

... More
(e )Bus Bar supporting Spout for 33 KV VCB bus bar

2

-

-

... More
(f) Spring Charging Motor for 33 KV VCB (110 V DC/230 V AC)

2

-

-

... More
(g) TNC Switch for 33 KV VCB

4

-

-

... More
(h) IDMT Relay for 33 KV VCB (Over current+earth fault Relay with minimum setting of current and timing inrush setting, over current, high set, earth fault, TCH, fault record, storage, for Simens/ABB make VCB, CT-115A, Aux Voltage 24-230 Volt AC/DC)

1

-

-

... More
(j) Space Heater 200/230 Volt AC

10

-

-

... More
(k) Thermostat 0-100 Degree Centigrade

10

-

-

... More
(l)Tulip Contact for 33 KV VCB.

3

-

-

... More
(m) Power Pack 230 V AC I/G, 110 V Dc O/G SMPS BASE, Backup 15 Min for 33 KV VCB

2

-

-

... More
(n) 33 KV CT with ratio 100/1-1 Amp, Single Phase, Indoor Type, 50 Hz

2

-

-

... More
(o) 33 KV PT of Ratio 33000V/110V , Single Phase, Indoor Type, 50 Hz

1

-

-

... More
(p) Fuse indoor type, 33 KV, Type PTAVT, Amps 3.15, 50 Hz

3

-

-

... More
(q) Ammeter digital type

2

-

-

... More
(r )Voltmeter Digital Type

2

-

-

... More
M&L for cleaning of all HT VCB up to 33KV capacitypanels externally and carried out painting with super enmelled paint all as specified and as directed.

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.