Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_MES_626117_1Bid Award Id
ViewTender No
85718/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
(c) All as per above item No 1 but for M .C.P.O Building at Kadmba Vanam.
11
-
-
... More
(d) All as per above item No 1 but for MAIN M.O BUILDING & M.O WAREHOUSE & M.O STORE & M.O CENTEEN Building at Core Area.
11
-
-
... More
(e) All as per above item No 1 but for VB Yard Building at Core Area
11
-
-
... More
(f) All as per above item No 1 but for CT Pool at Core Area
11
-
-
... More
(g) All as per above item No 1 but for HQ Kadamba Building at Core Area
11
-
-
... More
(h) All as per above item No 1 but for Hangar Building at Core Area
11
-
-
... More
(j) All as per above item No 1 but for Patanjali Hospital Building at Core Area
11
-
-
... More
(k) All as per above item No 1 but for HQ Main Building at Core Area
11
-
-
... More
(l) All as per above item No 1 but for NSRY Fire station Building at NSRY.
11
-
-
... More
Supply , installation , testing & commissioning in repairs Addressable fire alarm control panel single Loop complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Supply , installation , testing & commissioning in repairs Addressable fire alarm control panel double Loop complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
M&L in repair converntional type 16 zone fire alarm panel upto 20 detectors per zone with 6 hours battery back up, detector circuit monitored for open circuit, short circuit and 16 zone panel. including 2 No 12V,7 AH dry rechargeble battery etc complete all as specified and directed by Engineer-in-Charge.
6
-
-
... More
M&L in repair converntional type 10 zone fire alarm panel upto 20 detectors per zone with 6 hours battery back up, detector circuit monitored for open circuit, short circuit and 10 zone panel including 2 No 12V,7 AH dry rechargeble battery etc complete all as specified and directed by Engineer-in-Charge. :-
5
-
-
... More
Supply and fix in replacement Addressable dual loop card complete all as specified and directed by Engineer-in-Charge.
4
-
-
... More
Supply and fix in replacement Zone cards 10 zone card &16 zone card & 8 zone &4 zone etc complete all as specified and directed by Engineer-in-Charge.
11
-
-
... More
Supply & installation in repairs of Addressable Smoke detector along with required accessories complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply & installation in repairs of Addressable Heat detector along with required accessories complete all as specified and directed by Engineer-in-charge.
25
-
-
... More
Supply & installation in repiars of Addressable Multi Sensor detector along with required accessories complete all as specified and directed by Engineer-in-charge.
124
-
-
... More
Supply & installation in repairs of Addressable Isolator Module along with required accessories complete all as specified and directed by Engineer-in-charge.
19
-
-
... More
Supply & installation in repairs of Addressable Control Module along with required accessories complete all as specified and directed by Engineer-in-charge.
17
-
-
... More
Supply & installation in repairs of Addressable Sounder cum strobe along with required accessories complete all as specified and directed by Engineer-in-charge.
24
-
-
... More
Supply & installation in repairs of Addressable Manual Call Point along with required accessories complete all as specified and directed by Engineer-in-charge.
92
-
-
... More
Supply & Laying in repairs of 2 Core 1.5 Sq mm Copper Flexible Cable for control wiring with & including copper lugs, connectors etc complete all as specified and directed by Engineer-in-charge.
252
-
-
... More
Supply & Fix in repairs lead acid type battery of 12 Volts 7 AH capacity complete all as specified and directed .Make exide or Equivalent.
28
-
-
... More
Supply and installation in repair of network card of Fire Alarm control panel complete all as specified and directed
4
-
-
... More
Supply and installation in repair of Power supply of Fire Alarm control panel complete all as specified and directed
5
-
-
... More
Supply and installation inrepair of Display of Fire Alarm control panel complete all as specified and directed
5
-
-
... More
Supply and installation in repair of loop card of Fire Alarm control panel complete all as specified and directed
4
-
-
... More
Supply and installation inrepair of mother board of Fire Alarm control panel complete all as specified and directed
4
-
-