Military Engineer Services Tender
View complete overview of Goa MES Tender
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_695754_1Tender No
8637/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item No 01 here in before but of size 3 1/2 core 50 sqmm.
250
-
-
... More
All as per item No 01 here in before but of size 3 1/2 core 70 sqmm.
100
-
-
... More
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard / dense soil getting out and leveling of bottom surface to required level for laying UG cable / erection of poles complete all as specified.
76
-
-
... More
Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft / disintegrated rock getting out and leveling of bottom surface to required level complete all as specified and directed
153
-
-
... More
Excavation in trenches by cutting of road crossing / PCC hard standing, under boundary wall for laying of pipe / cable including making good the existing surface with same finish to match the original finish complete all as specified and directed.
2
-
-
... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed by Engr-in-charge.
206
-
-
... More
Removing excavated material of soils from site to a distance not exc 50 mtr away and depositing where directed not exc 1.5mtr from the starting point complete all as specified and directed by Engr-in-charge.
29
-
-
... More
Supply and laying Double walled corrugated pipe (DWC) confirming to IS 14930 heavy duty 110/63 mm bore for cable protection as a guard pipe including required accessories etc. including taking down existing pipe any type complete as specified and directed.
850
-
-
... More
Supply and fix or laying in trenches / on wall / poles / structures as in repairs GI tubing light grade for road crossing / for cable protection / fixing of pigmi lights etc, of the following sizes including necessary provision for cable entry if required in pigmi lights pole, fixing screws of under mentioned dia of pipes complete all as specified and directed.
-
-
-
... More
80 mm dia
6
-
-
... More
50 mm dia
12
-
-
... More
S & F in repairs LT heat shrinkable Straight through cable Jointing kit complete with jointing material and accessories suitable for 2core XLPE armoured Aluminium conductor cable of size 10 to 16 sqmm complete all as specified.
2
-
-
... More
All as per item No 13 here in before but of size 4 core 16 to 25 sqmm complete.
2
-
-
... More
All as per item No 13 here in before but of size 3.5 core 35 to 50 sqmm complete
2
-
-
... More
All as per item No 13 here in before but of size 3.5 core 70 to 95 sqmm complete.
2
-
-
... More
Material and labour for fault finding of LT cables of size 35 to 120 sqmm 3.5 / 4 core and any length with fault detective machine by thumbing method and suitable voltage and all as per manufactures instructions including providing straight through joint and additional cable of same existing size suitable to site requirement complete all as specified and directed by Engr-in-charge.
Note :-
cable joint and cable shall be measured and paid separately under relevant item of Sch 'A'
4
-
-
... More
Supply and fix in repair changeover switches on load change over switches 4 poles 630 Amps in sheet steel enclosure with in closure, including necessary spreaders / cable lugs / gland / nut, bolt and washers if required complete all as specified and directed. (Make :- L&T Cat No CO46300OSOO or equivalent HPL / Havells)
2
-
-
... More
All as per item No 18 here in before but of capacity 400 A 4 pole 415 Volts complete
4
-
-
... More
All as per item No 18 here in before but of capacity 250 A 4 pole 415 Volts complete
2
-
-
... More
All as per item No18 here in before but of capacity 200 A 4 pole 415 Volts.
4
-
-
... More
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 125 to 160 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed
4
-
-
... More
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 poles 415 volts with adjustable type 200 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed
3
-
-
... More
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 poles 415 volts with adjustable type 250 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed.
2
-
-
... More
Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 400 Amps with breaking capacity 36 KA complete including necessary connection with suitable size aluminum / copper cable lugs complete all as specified and directed by Engr-in-charge. Make : L & T or equivalent
2
-
-
... More
M & L for preparation of old cement coated surface, cleaning the surface of the RCC street light pole (LT) above the ground level to top of the pole including coping area (if provides) with one coat of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole and aluminiun paint for Iron cross arms channel / light bracket etc, including writing of pole number (MES........) complete all as specified and directed.
4
-
-
... More
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts / bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 20 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed including demolish existing earth pit taking out old materials.
3
-
-
... More
M & L for Earthing complete with GI earth plate, electrode,600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed including demolish existing earth pit taking out old materials.
2
-
-
... More
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts / bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed including demolish existing earth pit taking out old materials.
2
-
-
... More
Attending complaints for day to day repair / maint work for outer / inner perimeter / security / street / dispersal / high mast / search lights / any description by taking down carefully the existing non operational / unserviceable lights from and description, repair / replacement of unserviceable spares and re-fixing the same in the existing location after completion of repair work complete all as specified and directed by Engr-in-charge.
Note:-
(a) All new spares for the above lights will measure and paid separately under relevant item of this schedule.
Contd .SL No 30.01/-
300
-
-
... More
(b) The contractor / contractor's supervisor shall be report to AGE E/M- I maint office in all working days at 0900 AM and collect the complaint slip for defect / unserviceable lights list carrying out and complete the repair work in the same day before 1800 hrs. If the contractor fails to complete the repair work within the 03 working days after receipt of complaint slip necessary recovery @ Rs 100.00 per fittings per day shall be recovered from the actual work done. For that the register shall be maintained and signed by both the Engr in Charge and contractor.
(c) Rate for all Tools and plants, safety equipments, transport including necessary minor spares such as insulation tape, connectors, fixing screws, connecting 2 core wires up to 2 mtr length shall be included in the quoted rates.
(d) All defected Electrical fittings & fixture/LED fittings and conventional type security light fittings partially serviceable are to be deposited to AGE E/M- I Store yard.
-
-
-
... More
Supply and fix in repairs cable junction boxes IP 66 protected “halogen free and weather proof” suitable for outdoor type ( with metric knockouts for cable entry) of size 333 x 233 x 120 mm mm including necessary suitable size new aluminium bus bar 04 Nos mounted on saddles suitable for 3 phase 4 wire system of suitable length and thickness, proven of new aluminium cable lugs for incoming & out going LT cable connections with junction box fixing clamps made up of GI flat 25 x 3 mm, nut and bolt on poles complete all as specified and directed.
20
-
-
... More
Supply and fix in repairs LED post top made in die-cast aluminium housing with decorative clear opal acrylic diffuser with white powder coated aluminium reflector IP-65 protection of 40 watts capacity and including connections service wire with 3 run of 2.5 Sq mm aluminium unsheathed multi stranded wire complete all as specified and directed
4
-
-
... More
S & F in repairs Energy efficient LED street Light 60 Watts unsheathed wire multi stranded from LT over head line to the connector of fitting, connection wires not to be less than 2.5 metre in length duly run through GI bracket complete 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 / 66 protection complete all as specified and directed
25
-
-
... More
All as per item No 33 here in before but of capacity 90 watts complete all as specified and directed
35
-
-
... More
All as per item No 33 here in before but of capacity 120 watts complete all as specified and directed
8
-
-
... More
All as per item No 33 here in before but of capacity 70 watts complete all as specified and directed
8
-
-
... More
S & F in repairs Street light bracket made out of GI tubing 32 / 40 mm dia of approx 1.2 mtr length light grade bend to shape suitable for security / street light / Pigmi light fittings with necessary fixing arrangements by using GI flat of 40 x 6 mm size including nut, bolt, washers etc complete all as specified.
10
-
-
... More
S & F in repairs Street light bracket made out of GI tubing 25 mm dia, light grade bend to shape of approx length 1.0 mtr long suitable for security / street light / Pigmi light fittings with necessary fixing arrangements with one coat of red oxide and two coats of synthetic enamel paint including nut, bolt, washers etc complete all as specified.
6
-
-
... More
Taking out the existing unserviceable LED street / high bay / security light fittings of any type/make and capacity from any position for carrying out repairs, replacement of spares such as LED panel / driver or PCB of any make and re-fixing the same after repair work including necessary electric connections complete all as specified and directed by Engr-in-charge.
Note :- New spares will be measured and paid separately as " Supply only " under item Nos 40 & 41 of this schedule
15
-
-
... More
Supply only LED driver with transformer suitable for 45 to 60 watts LED street / Flood / high bay light fitting of complete all as specified and directed.
5
-
-
... More
Supply only LED driver with transformer suitable for 70 to 90 watts LED street / Flood / high bay light fitting of complete all as specified and directed.
5
-
-
... More
Supply only LED driver with transformer suitable for 120 to 150 watts LED street / Flood / high bay light fitting of complete all as specified and directed.
5
-
-
... More
Supply and fix in repairs Galvanised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete including taking down / dismantling the old items complete all as specified and directed
0.5
-
-
... More
Dismantling of existing old unserviceable ACSR of any size from any descritpion, material and labour for providing new ACSR conductor all as specified and directed including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes complete all as specified and directed by Engr-in-charge. Note:-
Rates for new AAC for binding purpose is included in this rate.
0.5
-
-
... More
Dismantling of existing old unserviceable ACSR of any size from any description, material and labour for providing new ACSR conductor all as specified and directed including stringing through existing RCC poles, fixing in insulators, jumpers with polythene pipe, aluminium binding wire etc complete of different sizes complete all as specified and directed.
Note:-
Rates for new AAC for binding purpose is included in quoted rate.
0.5
-
-
... More
S & F in repairs Pin type porcelain vitreous, brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as specified and directed.
3
-
-
... More
S & F in repairs Shackle type Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, of height 100 mm and dia 115 mm having working pressure 1100 volts grade complete all as specified and directed.
2
-
-
... More
M & L in repairs for stay assembly complete with all sections such as stay plate, stay clamps, Stay brackets with 20 mm dia stay rod complete all as shown in electrical plate No. 1 of SSR Part 1 complete. Note:-
Loop insulator, excavation and concrete work will be measured and paid separately
2
-
-
... More
M & L in repairs for stay strand size 7 / 3.15 mm all as specified and fixed to stay and pole including lightening complete all as specified and directed.
0.2
-
-
... More
M & L in repairs loop type insulator vitreous porcelain white, brown or green of size 65 x 90 mm overall dimension and 16 mm clearance of hole complete all as specified.
2
-
-
... More
Taking down the GI / PVC cable protection pipe along with UG cable from pole / wall by disconnecting all incoming and outgoing connections from the unserviceable street / security light junction boxes and breaking the pole coping, opening the cable loop kept under the pipe / any description by excavation of earth work, cut the damaged portion of UG cable of any size and making new termination arrangement etc,. cut the GI / PVC pipe of required length, fix the same in the existing pole by fixing new GI clamps , provision of new cable junction boxes IP 66 protected “halogen free and weather proof” suitable for outdoor type ( with metric knockouts for cable entry) incl necessary suitable size new aluminium bus bar 04 Nos mounted on saddles suitable for 3 phase 4 wire system of suitable length and thickness, connection of street light connections, re-filling the excavated soils including making good the damaged coping by providing new PCC 1:3:6 & plastering of existing size complete all as specified and directed
6
-
-
... More
Dismantling carefully the old unserviceable items elect motor / Diesel generator, LT panel, elect cables, street light and iron scrap deposited to AGE E/M-I Store yard by using suitable labour, T&P, transports etc. complete all as specified and directed.
2
-
-
... More
Taking down of existing UNSV flood light fitting of any type, supply and fix LED Flood light fittings 180 Watts including fixing arrangement and including connections with 3 run of 2.5 Sqmm aluminium unsheathed wire multi stranded, necessary connections complete all as specified and directed by Engr-in-charge. Make : Bajaj or equivalent in Philips / CG / shakti
5
-
-
... More
Taking down of existing UNSV flood light fitting of any type, supply and fix LED Flood light fittings 200 Watts including fixing arrangement and including connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multi stranded, necessary connections of any height like high mast pole / LT poles / wall etc. complete all as specified.
5
-
-
... More
Taking down of existing UNSV flood light fitting of any type, supply and fix LED Flood light fittings 250 Watts including fixing arrangement and including connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multi stranded, necessary connections of any height like high mast pole / LT poles / wall etc. complete all as specified.
4
-
-
... More
S & F in repairs LED Aviation light comprising of aluminium housing with polycarbonate enclosure, 302 Nos. LED is provided with necessary fixing arrangements & electrical connections complete all as specified and directed.
4
-
-
... More
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated 3 core stranded aluminium conductor severed with an inner sheathing of PVC tape PVC sheathed 4 sqmm nominal cross section in service connection / light connections in poles from junction box to fittings complete all as specified and directed.
200
-
-
... More
Taking down carefully flameproof ceiling fans of size 1200 mm sweep at any height of any sweep / make / model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing, overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adopter, screws, nuts, spring washers for blade / body etc and replacement of components / accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed.
Note:- (i) Rewinding of fan motor, painting will be measured and paid separately under relevant item of schedule. (ii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate
3
-
-
... More
All as per Item No 58 above but flame proof exhaust fan of size upto 300 mm complete.
3
-
-
... More
Material and labour for rewinding of flameproof ceiling fan motor of size 1200 mm sweep of any make / model / type with new supper enameled copper winding wire of similar gauge and number of turns as existing, including cleaning the motor properly and applying varnishing heating and assembling of fan motor and rotor fixing back after testing including removing burnt out copper winding wire from ceiling fan motor complete all as specified and directed by Engr-in-charge.
3
-
-
... More
All as per item No 60 here in before but of flameproof exhaust fan of size upto 300 mm and 380 mm sweep complete all as specified and directed by Engr-in-charge.
4
-
-
... More
S & F in repairs Switch Flameproof WP Rotary type with termination box in LM6 16A single pole 250V all as specified and directed by Engr-in-charge.
11
-
-
... More
Supply and fixing LED light fitting 1 x 20 Watt flame proof, CMRI certified recommended for gas / vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-charge.
11
-
-
... More
Taking down Aluminum strip of size 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground and re-fixing in the same location with new nuts and bolts, screws of suitable size and length and connected to air termination rod on top of the hangar complete all as specified and directed by Engr-in-charge.
130
-
-
... More
S & F in repairs Aluminium strip 25x3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground including taking out old one complete all as specified and directed by Engr-in-charge.
150
-
-
... More
M & L for Air termination, single pointed, Aluminium rod 12 mm dia and 300 mm long, mounted on aluminium base plate rigid fixed on top roof height complete and insulated from base and taking out old unserviceable complete all as specified and directed by Engr-in-charge.
15
-
-
... More
M & L for removing vegetation, grass, scrubs and bushes or any small tree branches growing in Substation yard along with fencing, around the pole, under the HT / LT transmission lines, yards or any description by manually / mechanically and keep the substation yard neat and clean complete all as specified and directed Note:- Unit rate quoted deemed to include to keep the installation neat and clean throughout the period of contract and each cleaning will be measured and paid.) Complete all as specified and directed.
12000
-
-
... More
M & L for Cutting and trimming of tree branches of girth upto 150 mm dia and 3 mtr all around of any size obstructing lamination of street light / perimeter lights and touching LT / HT Over head line including removing trimmed tree branches complete all as specified and directed
Note : The contractor will be provide all T&P and safety tools with own arrangement and cost of the same is included in quoted rate.
80
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%