Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_693283_1Tender No
85915/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as directed.
1
-
-
... More
Material and labour for providing new GI wire 4 mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, including disnmantling of existing old unserviceable earth wire and gradle guard of any size form the position all as directed.
0.2
-
-
... More
Material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 incl stay clamp, loop insulator excavation and concrete measured in this quited Rate, including dismantling old unserviceable stay assembly complete all as directed.
2
-
-
... More
M & L in repairs for Galvanised Stay wire of size 7/4 mm incl dismantling old wire all as directed.
0.5
-
-
... More
S & F in repairs of Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment cut to required shape and size for cable duct or any other description complete all as directed.
180
-
-
... More
Repairing/ Servicing the Air break isolating switch HT 33 KV 200/400 Amps by replacing the defective major Spares including provn of minor bolts nuts etc all as specified.(Note :- Major spare will be measured & paid seperately under relevant item of Sch'A )
4
-
-
... More
Supply only following spares of 33 KV Airbreak switch.
-
-
-
... More
a)Male contact/moving Contact Blade
2
-
-
... More
b)Female contact/Fix Contact Jaw
3
-
-
... More
c)Rotating contactor pipe 200A/400 A
5
-
-
... More
d)MS jumper carrier
3
-
-
... More
e) back connector plate
3
-
-
... More
Supply & Lay , testing and commissioning XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 33000 Volts grade (earthed), 3 core 185 sqmm laid in trenches/floor/duct/fixed on poles/through GI tubing in different locations / areas complete
140
-
-
... More
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying of UG cable.
10
-
-
... More
Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required level for laying of UG cable. .
30
-
-
... More
Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wall for laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engr-in-charge.
3
-
-
... More
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata
22
-
-
... More
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point
18
-
-
... More
Supplying & Laying in trenches Clear Sand for cushioning under ground cable 8 cm below and 15 cm above complete in level all as specified. (punned thickness of sand will be measured and paid)
10
-
-
... More
Supply and lay un-reinforced precast concrete cable covers, class EHV , type- I with peak, size 300mm x 180mm x 40mm, all as specified and directed.
550
-
-
... More
S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the following sizes 100 mm Dia as in repairs :-
12
-
-
... More
M & L for PVC insulated unarmoured heavy duty electric cable with copper conductor 1100 V grade with cross section area 4 Core 4 Sqmm all as direcetd.
30
-
-
... More
M & L for PVC insulated armoured heavy duty electric cable with copper conductor 1100 V grade with cross section area 16 Core 2.5 Sqmm all as direcetd.
30
-
-
... More
Taking down Triple pole mechanism complete with DO Fuse unit from the site, supply and install DO fuse unit triple pole, mechanically operated, mounted on insulator and steel frame,with opertaing mechanism worked from ground level with GI pipe medium grade, for current rating upto 200 Amps and Air break (switch) insulator suitable for HT 11 KV out door type 50 Amp ( DO Fuse ) all as directed..
2
-
-
... More
S & F in repairs drop out (DO) fuse unit expulsion type outdoor three pole 200 Amp suitable for HT 33 KV, comprising of insulators, steel base mounting frame , GI nut bolts etc with 30A , HT barrel type fuse complete
3
-
-
... More
S & F in repairs incl testing, and commissioning of gang operated type air break switch horizontal/vertical type type mounting complete, double break and operation rod of suitable length 400 A capacity and suitable for 33 KV HT supply, complete all as specified and directed.
4
-
-
... More
S & F in repairs lighting arrestor Zinc oxide gap less type, station class suitable for 33 KV/10 KA complete with all fittings all as specified and directed.
6
-
-
... More
S & F in repairs single post insulator, 33 KV with mounting spindle etc. complete.
12
-
-
... More
S & F in repairs Pin insulator, 33 KV with mounting spindle etc. complete.
12
-
-
... More
S & F in repairs disc insulator, 33 KV with hardware fittings etc. complete.
12
-
-
... More
M&Lpreparation of old painted surfaces of HT 33/11 KV MRS at Hansa consisting of Steel poles/ ISMBs, cross arms, GOD pipe,clamps etc., having of any description and applying one coat of Aluminium paint by mannualy (incl structure) all as directed. The approx particulars are as under :-
a)ISMB 200 X 100 x 6 mm 12 mtr height as pole- 18 Nos
b)ISMB 200 X 100 x 6 mm 2.5 to 3.5 mtr height as pole - 30 Nos
(c) Angle Iron cross support 75 x 75 x 6 |mm - 50 RM
(d) MS Flat 50 x 4 mm - 24 RM
(e) C Channels of size 75 x 75x 6 mm - 110 RM
(f) ISMB 150 x 100 x 6 mm as cross member 284 RM Note:- a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which iS not particularly mentioned in this item.
b) This painting work will be carried out during Holidays only to avoid electrical shut down.
1
-
-
... More
M & L for servicing of 33 KV VCB at Hansa MRS, dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required, reassembling the VCB and reinstalling back to its original position checking and repairsing the current circuit panel wiring , relay testing and provision of minor spares as required complete including operational testing and commissoning all as directed.
Note : New major spare parts will be measured and paid under this items
3
-
-
... More
M & L for replacement of the following spares for outdoor VCB 33 KV 800 A 750 MVA fault level 36V-26/2000 of existing make or as approved by GE and all as directed including dismantling old unserviceable one.
-
-
-
... More
i) Closing coil 30V DC
1
-
-
... More
ii) Tripping coil 30V DC
1
-
-
... More
iii) Anti pumping device 30V DC
1
-
-
... More
iv) 33 KV porcelain bushing for VCB Top
1
-
-
... More
v) 33 KV porcelain bushing for VCB bottom
1
-
-
... More
vi) Connector strip 16 way
6
-
-
... More
vii) Earth Fault and over current relay of L & T Model No MC61A 24-110V
1
-
-
... More
viii) Digital type power factor indicator meter
1
-
-
... More
ix) Digital type Voltmeter / Ammeter 96 x 96 mm size
2
-
-
... More
S & F in repairs strip type heater 40/60 watt approx 4"/6" in length complete all as specified and directed.
10
-
-
... More
M & L for PVC sleeves suitable for LT/HT ACSR conductor/jumper in any type in R Y B Colours superior quality inserted over the ACSR all as directed.
20
-
-
... More
S & F in repairs HT DO Fuse element for 33 KV system of 40 Amps.
24
-
-
... More
S & F in repairs HT DO Fuse element for 33 KV system of 50/60 Amps.
24
-
-
... More
S & F in repairs sealed maintenance free battery 2 Volts 100 Amps for UPS supply incl necessary connections complete all as directed.
10
-
-
... More
M & L for preparation of old cement coated surface, cleaning the surface of the RCC pole (HT) 11 Mtr long in 1/2/4 pole structures above the ground level incl coping area with 2 coats of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole numbers/letters in white columns all as directed.
8
-
-
... More
S & F in repairs for Breather unit with superior quality blue colour silica jel, to maintain the exact value of grade for transformer of capacity 33/11 KV type 2 MVA Transformer, including taking down unserviceable complete all as specified.
2
-
-
... More
S & F in repairs HV insulator with studs nut & washers suitable for 33 / 11 KV, HV side of transformer 2 MVA
3
-
-
... More
S & F in repairs LV insulator with studs nut & washers suitable for 33/11 KV LV side of transformer of Capacity 2 MVA
3
-
-
... More
Taking out the existing serviceable Post/disc/pin insulator of 33 KV capacity carefully and re-fixing the same in the new cross arms/structure incl replacement of new hardware such as GI spindle, nut, bolt and washers complete all as directed
20
-
-
... More
Taking out the old HT 33 KV UG serviceable cable of 3 core 185 Sq mm from trenches/ floors/ walls and relaying/diversion/jointing the same in the new trenches/new location as directed and connecting all as directed
20
-
-
... More
M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thick by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and as directed.
5
-
-
... More
M & L for painting of HT panel of any description with one coat of synthetic enamel paint of standard colour code over the existing painted surfaces after preparing the old painted surfaces by using spray gun all as directed.
100
-
-
... More
M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately. cutting of grass is month wise measured and paid separeatly.
12500
-
-
... More
M & L for Cutting and trimming of tree branches 3 mtr all around of any size which is obstructing illumination of street light and touching LT / HT Over head line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely)
200
-
-
... More
Carry out Material/machineries & labour for fault finding of 33 KV or 11 KV HT under ground cable of length up to 1.5 KM in case of cable fault such as short circuit/burn out/earth fault etc including carryout| necessary hypot test by injection high voltage up to 50 KV complete all as specified and as directed.
5
-
-
... More
S & F in repairs including testing, and commissioning lightning arrester (LA) for 33KV HT grade with nuts,bolts, washers clams and all accessories as per sample including taking down unserviceable complete all as specified by engr- in- |charge. Note :- Any item not included in CA |and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
4
-
-
... More
S & F in repairs including testing, and commissioning Aluminium bus bar of suitable size to match the existing for 33KV HT grade with nuts, bolts, washers , clams and all accessories as per site requirement including taking down old unserviceable complete all as specified. Note :- Any item not included in CA and required for successful operation of the panel will be provided by the contractor & same shall deemed to be included rate quoted.
150
-
-
... More
Disconnecting, opening of VCB description and any make of rating 11 KV 400/800 Amps capacity for servicing / and removing loverhauling, taking out unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing testing |complete all a specified and directed. Note: (0 Replacement of unserviceable parts shall |be measured and paid for separately under appropriate item of Sch 'A' as supply only but fixing charges of the parts replaced /repaired is deemed to be included in these item. (ii) Servicing shall be got carried out |by the authorised rep of the VCB manufacturer and the service engineer will submit a service report for each VCB. (iii) |Any item not included in CA and required |for successful operation of the panel will be provided by the contractor &% same shall deemed to be included rate quoted.
3
-
-
... More
Supply only following items/ spare parts suitable for 11KV VCB, 400/800 Amnps capacity of existig make dismantled / fixed under Sch 'A' item
-
-
-
... More
Vacuum circuit breaker main mechanism assembly complete with all accessories all as specified and directed by Engr-in-Charge
1
-
-
... More
Vacuum Interrupter type suitable for 11 KV VCB Panel complete all WL-33379 as specefied and directed.
2
-
-
... More
Isolating contact assembly 400/800 Amps |suitable for 11 KV VCB Panel complete all as specefied and directed.
2
-
-
... More
Dripping Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed.
2
-
-
... More
Close Coil assembly 30 Volts DC suitable for 11 KV VCB Panel complete all as specefied and directed.
2
-
-
... More
Motor & Gear assembly 110V AC and 220 AC for 11 KV VCB Panel complete all as specefied and directed.
2
-
-
... More
TNC switch for 11 KV VCB Panel complete all as specefied and directed.
2
-
-
... More
Indication lamp LED type suitable for 230 Volts AC 50Hz and 110/30 Volts DC supply.
6
-
-
... More
Disconnecting and taking down unserviceable current transformer of any description and in any position and supply, installation, commisioning and testing of cast resin type 11KV current transformer |having ratio 100+50/5+5A as per IS: 2705 |having protection core class 5P10, burden of 15VA and metering core class CLl.0 and burden of 15VA, breaking capacity of 13.1 KV for 1.0 second all as specified and directed.
3
-
-
... More
Disconnecting and taking down unserviceable voltage transformer of any description and in any position and supply, installation, commisioning and testing for 11KV single phase indoor oil cooled PT of ratio 11KV/RT 3/10V/RT 3/110/RT 3 class 0.5-3, burden 100VA, insulation level |35/75 KV, voltage factor 1.2 cont and 1.9 for 30 sec, conforming to IS-3156 complete all as specified and directed.
2
-
-
... More
Taking out old but serviceable ACB of capacity 400 to 1200 amps 415 volts AC 50 HZ at various sub station and carry out necessary servicing , gresing to fixed and movable part, cleaning complete internally and testing after reinstallation at original position complete all as specified and directed. ( Any demage occures during servicing will be borne by the contractor ).
5
-
-
... More
Supply and fix charging motor 110V |AC/DC, 220V AC/ DC of suitable size for ACB of capacity 400 to 1200 Amps complete all as specified and directed by Engr-in-charge
2
-
-
... More
Supply and fix control relay for charging motor 110V AC/ DC, 220V AC/DC of Suitable size for ACB of capacity 400 to 1200 Amps complete all as specified and directed by Engr-in-charge
2
-
-
... More
Repair and rewinding for exhaust fan plastic body AC single phase 230V of size 250 mm sweep 1400 RPM heavy duty with louver and taking down, cleaning the body of exhaust fan properly, refixing it at same location all as specified and directed.(nut bolts, washer, wire etc required for refixing included in quoted rate)
17
-
-
... More
S & F in repairs cable jointing kit for 33KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
2
-
-
... More
S & F in repairs cable jointing kit for 33KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
1
-
-
... More
S & F in repairs cable jointing kit for 33KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 sqmm.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%